MAURY USCG vessel records Sign in
← All vessels

CASSVILLE FERRY

CASSVILLE FERRY is a 1966 passenger barge (inspected). The Coast Guard has recorded 43 inspections since 1985, most recently in April 2015, along with 26 deficiencies.

Records from 1985 to 2015. Most recent: inspection, 29 April 2015.

Built
1966
Last inspected
29 April 2015
Documentation
No Operation - PM · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

Flag
UNITED STATES
—
Maury page id
psix-45323

Inspections, by type

…with no type recorded4
Years with a record 28 calendar years (1985–2015)
The 43 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 11 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.

Documentation record

Registered dimensions (L × B × D)64.5 ft × 27.2 ft × 3.7 ft
Registered tonnagegross 56 / net 56
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderHUMBOLDT BOAT SERVICE · ST. LOUIS, MO, UNITED STATES · built 1966
Hull materialSteel
PropulsionNot recorded
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portCASSVILLE, WI
Trade endorsementsCoastwise, unrestricted
DocumentationNo Operation - PM · issued 30 June 2004
Service, as the file records itPassenger Barge (Inspected)
Hull formunknown (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it56 - Regulatory (Subpart C or D), Gross Ton
56 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 43

29 April 2015 Administrative Inspection
Administrative · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 5113488
11 July 2011 Administrative Inspection · Drydock Extension
Administrative · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 4078725
17 May 2010 Annual Inspection
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 3746200
13 January 2010 Administrative Inspection
Administrative · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 3663874
14 July 2009 DAPI Audit · Annual Inspection
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 3535636
22 July 2008 Re-Inspection
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 3282373
11 March 2008 Administrative Inspection
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3162310
26 April 2007 COI Inspection
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 2915607
11 July 2006 Hull Examination
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 2938638
25 April 2006 Annual Inspection
Physical examination · MSD QUAD CITIES · USCG Heartland District (CGD-H) · Activity 2639371
25 April 2005 Annual Inspection
Physical examination · MSD QUAD CITIES · USCG Heartland District (CGD-H) · Activity 2632189
22 April 2004 Re-Inspection
Physical examination · MSD QUAD CITIES · USCG Heartland District (CGD-H) · Activity 2018242
22 April 2003 Re-Inspection
Physical examination · MSD QUAD CITIES · USCG Heartland District (CGD-H) · Activity 1778606
22 April 2002 COI Inspection
Physical examination · MSD QUAD CITIES · USCG Heartland District (CGD-H) · Activity 1607805
6 November 2001 Hull Examination
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1362541
10 April 2001 Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1464373
27 May 2000 Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1391289
29 April 1999 COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1464176
5 May 1998 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1456595
8 August 1997 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1118449
1 July 1997 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 778191
22 May 1997 Hull Examination
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1106711
6 March 1997 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1100109
24 May 1996 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1181102
2 May 1996 COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1430189
12 March 1996 Hull Examination
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1383178
18 May 1995 Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1181243
28 April 1994 Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1401854
13 May 1993 COI Inspection · Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1435376
9 March 1993 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 835357
12 November 1992 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1410759
28 April 1992 Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1255033
26 April 1991 Re-Inspection · Hull Examination
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1215694
11 April 1990 COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1224654
24 October 1989 Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 912587
10 June 1988 Administrative
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1201036
23 February 1988 Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1331791
9 April 1987 Administrative
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1329211
12 March 1987 Deficiency Check · COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1326382
20 May 1986 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1304173
19 March 1986 Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1304172
27 August 1985 Credit Drydock
Administrative · MSO Paducah · USCG Heartland District (CGD-H) · Activity 987807
5 February 1985 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 973172

Deficiency record · 26

Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 14 July 2009 Resolved
Fire extinguishers were past due on servicing. required operator to correct immediately.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 July 2009
Resolved 21 June 2011
Resolution: Discrepancy was cleared, but never entered into MISLE
Electrical › Electrical Distribution System (service) › Junction Box
Issued 14 July 2009 Resolved
24 volt junction box had loose cover. Operator stated they were going to replace the box.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 July 2009
Resolved 21 June 2011
Resolution: Discrepancy was cleared , but not entered into MISLE
Fire Fighting › Portable CO2 Fire Extinguisher
Issued 22 April 2002 Resolved
Ensure 2 B2 Fire extingushiers are on board vessel in operating condition IAW 46 CFR 181.500
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 April 2002
Resolved 20 May 2002
Lifesaving › Lifebuoys
Issued 22 April 2002 Resolved
Replace lifering with line IAW 46 CFR 180.70
Action required: 705 - Other - as specified
Due 23 May 2002
Resolved 20 May 2002
Personnel › Training
Issued 22 April 2002 Resolved
Log crew training IAW 46 CFR 185.420
Action required: 705 - Other - as specified
Due 25 May 2002
Resolved 20 May 2002
Engineering › Bilge Water Management System
Issued 22 April 2002 Resolved
Prove proper operation of bilge system IAW 46 CFR 182.520
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 April 2002
Resolved 10 May 2002
Lifesaving
Issued 10 April 2001 Resolved
Retro on life ring needs replacing
Condition: Unknown
Due 4 May 2001
Resolved 4 May 2001
Electrical
Issued 10 April 2001 Resolved
Replace defective globes on all lights on tow vessel
Condition: Unknown
Due 4 May 2001
Resolved 4 May 2001
Lifesaving
Issued 10 April 2001 Resolved
Child/Adult pfd's were not seperated.
Condition: Unknown
Due 4 May 2001
Resolved 4 May 2001
Electrical
Issued 10 April 2001 Resolved
improper wiring to electronics
Condition: Unknown
Due 4 May 2001
Resolved 4 May 2001
Construction/Loadline
Issued 27 May 2000 Resolved
REPLACE OR SERVICE ALL GATE VALVES IN THE BILGE SUCTION SYSTEM.
Condition: Unknown
Due 23 April 2002
Resolved 23 April 2002
Lifesaving
Issued 27 May 2000 Resolved
REPLACE RETRO REFLECTIVE TAPE ON 16 ADULT LIFE JACKETS PRIOR TO GETTING UNDERWAY WITH PASSENGERS.
Condition: Unknown
Due 27 May 2000
Resolved 27 May 2000
Fire Fighting
Issued 27 May 2000 Resolved
RESTENCIL FIRE AX HANDLE WITH VESSEL'S MANE.
Condition: Unknown
Due 27 May 2000
Resolved 27 May 2000
Lifesaving
Issued 5 May 1998 Resolved
REPLACE (7) SEVEN LIFEJACKETS PRIOR TO GETTING UNDERWAY WITH PASSENGERS.
Condition: Unknown
Due 8 May 1998
Resolved 11 May 1998
Fire Fighting
Issued 5 May 1998 Resolved
REPLACE (1) FIREHOSE PRIOR TO GETTING UNDERWAY WITH PASSENGERS.
Condition: Unknown
Due 8 May 1998
Resolved 11 May 1998
Electrical
Issued 22 May 1997 Resolved
REPAIR WIRING TO NAVIGATIONAL LIGHTS AND PROVIDE WIRE HANGARS IN HOLDS.
Condition: Unknown
Due 22 May 1997
Resolved 22 May 1997
Lifesaving
Issued 2 May 1996 Resolved
PROVIDE NEW BATTERY FOR RING BUOY LIGHT.
Condition: Unknown
Due 2 May 1996
Resolved 2 May 1996
Electrical
Issued 2 May 1996 Resolved
REPLACE FRAYED WIRING THROUGHOUT VESSEL.
Condition: Unknown
Due 2 May 1996
Resolved 2 May 1996
Construction/Loadline
Issued 12 March 1996 Resolved
REPLACE HULL PLATING PRIOR TO 01MAY97.
Condition: Unknown
Due 12 March 1996
Resolved 12 March 1996
Lifesaving
Issued 28 April 1994 Resolved
REPLACE DEFECTIVE LIFE PRESERVER.
Condition: Unknown
Due 2 May 1994
Resolved 2 May 1994
Fire Fighting
Issued 28 April 1994 Resolved
STENCIL VESSEL NAME ON FIRE AXE.
Condition: Unknown
Due 2 May 1994
Resolved 2 May 1994
Deck/Cargo
Issued 12 March 1987 Resolved
INSTALL FIXED BILGE SYSTEM AS PER 46 CFR 182.25-5. THIS SYSTEM SHALL CONSIST OF INDIVIDUAL BILGE LINES AND SUCTIONS FOR EACH WATERTIGHT COMPART-MENT WITH THE EXCEPTION OF THE BOW AND STERN COMPARTMENTS. THE SYSTEM SHALL BE PIPED TO A MANIFOLD SERVICED BY A POWER DRIVEN PUMP.
Condition: Unknown
Due 12 March 1987
Resolved 12 March 1987
Navigation
Issued 19 March 1986 Resolved
REPAIR AND MAKE OPERATIONAL PORT BOW RUNNING LIGHT.
Condition: Unknown
Due 19 March 1986
Resolved 19 March 1986
Deck/Cargo
Issued 19 March 1986 Resolved
REPAIR AND REATTACH END GATES.
Condition: Unknown
Due 19 March 1986
Resolved 19 March 1986
Fire Fighting
Issued 19 March 1986 Resolved
RECHARGE ONE B-II FIRE EXTINGUISHER.
Condition: Unknown
Due 19 March 1986
Resolved 19 March 1986
Construction/Loadline
Issued 19 March 1986 Resolved
REPLACE GOOSENECK VENT IN DECK IN WAY OF STARBOARD NO. 2 COMPARTMENT.
Condition: Unknown
Due 19 March 1986
Resolved 19 March 1986

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.