MAURY USCG vessel records Sign in
← All vessels

DITZUM

DITZUM is a 1991 freight ship. The Coast Guard has recorded 21 inspections since 1997, most recently in May 2003, along with 15 deficiencies and 1 operational control.

Records from 1997 to 2003. Most recent: inspection, 29 May 2003.

Built
1991
Last inspected
29 May 2003
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9033701 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
453236
Flag
GERMANY
—
Maury page id
psix-453236

Inspections, by type

…with no type recorded14
Years with a record 7 calendar years (1997–2003)
The 21 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 23 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it1644 - Convention (Subpart B), Net Ton
3236 - Convention (Subpart B), Gross Ton
4192 - Dead Weight, Ton
24 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 21

29 May 2003 Administrative Inspection
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1804683
29 May 2003 Administrative Inspection
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1804803
20 May 2003 Administrative Inspection
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1797429
6 December 2002 Annual Inspection · Ballast Water Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1715208
9 August 2002 Administrative Inspection
Administrative · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1662267
29 May 2002 Re-Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 1637800
18 March 2002 Security Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1494336
19 September 2001 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 293893
24 July 2001 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 292172
9 September 2000 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 281744
18 January 2000 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 273935
23 June 1999 Type not recorded
No type recorded · MSFO Portsmouth · USCG Northeast District (CGD-NE) · Activity 429878
22 June 1999 Type not recorded
No type recorded · MSFO Portsmouth · USCG Northeast District (CGD-NE) · Activity 92668
6 February 1999 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 425316
27 December 1998 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 423994
5 August 1998 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 418936
22 June 1998 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 416639
12 April 1998 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 414662
16 December 1997 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 410931
10 December 1997 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 509586
28 February 1997 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 400976

Deficiency record · 15

Deck/Cargo › Mooring/Anchoring
Issued 6 December 2002 Resolved
PORT AND STBD CHAIN WASH HOLED AND LEAKING. PORT HAWS PIPE WASTED AT DECK AND LEAKING. MAKE PERMANTENT REPAIRS TO SATISFACTION OF CLASS LEGACY COMPONENT DESC: CHAIN WASH
Condition: Unknown
Action required: 705 - Other - as specified
Due 31 January 2003
Resolved 20 May 2003
Resolution: THIS UNIT RECEIVED CLASS REPORT
Engineering › Freshwater System (jacketwater cooling)
Issued 6 December 2002 Resolved
MAIN ENGINE JACKET WATER COOLER HAS 5 SOFT PATCHES ON INLET AND OUTLET PIPES. MAKE PERMANTENT REPAIRS TO SATISFACTION OF CLASS LEGACY COMPONENT DESC: JACKET WATER COOLER
Condition: Unknown
Action required: 705 - Other - as specified
Due 31 January 2003
Resolved 23 May 2003
Resolution: This office received class report.
Pollution Prevention/Response › Prevention Equipment
Issued 6 December 2002 Resolved
SEWAGE TANK HAS 2 SOFT PATCHES ON DISCHARGE PIPES. MAKE PERMANTENT REPAIRS TO SATISFACTION OF CLASS LEGACY COMPONENT DESC: Marine Sanitation Device, Type III
Condition: Unknown
Action required: 705 - Other - as specified
Due 31 January 2003
Resolved 20 May 2003
Resolution: THIS UNIT RECEIVED CLASS REPORT.
Engineering › Freshwater System (jacketwater cooling)
Issued 6 December 2002 Resolved
BOTH SHIP SERVICE GENERATORS HAVE NUMEROUS SOFT PATCHES AND TEMP REPAIRS ON COOLING WATER PIPES. MAKE PERMANTENT REPAIRS TO SATISFACTION OF CLASS LEGACY COMPONENT DESC: Piping
Condition: Unknown
Action required: 705 - Other - as specified
Due 31 January 2003
Resolved 20 May 2003
Resolution: THIS UNIT RECEIVED CLASS REPORT.
Engineering › Lubricating Oil Storage/Transfer System
Issued 6 December 2002 Resolved
OIL TRANSFER PUMP LOCATED LOWER ENGINE ROOM STBD SIDE HAS DISCHARGE PIPE DISCONNECTED AND RUBBER HOSE IN PLACE. MAKE PERMANTENT REPAIRS TO SATISFACTION OF CLASS LEGACY COMPONENT DESC: Pump
Condition: Unknown
Action required: 705 - Other - as specified
Due 31 January 2003
Resolved 20 May 2003
Resolution: THIS UNIT RECEIVED CLASS REPORT.
Engineering › Freshwater System (jacketwater cooling)
Issued 6 December 2002 Resolved
EXPANSION TANK FOR MAIN ENGINE AND SHIPS GENERATORS HOLED AND WASTED. MAKE PERMANTENT REPAIRS TO SATISFACTION OF CLASS LEGACY COMPONENT DESC: EXPANSION TANK
Condition: Unknown
Action required: 705 - Other - as specified
Due 31 January 2003
Resolved 20 May 2003
Resolution: THIS UNIT RECEIVED CLASS REPORT.
Pollution Prevention/Response › Prevention Equipment
Issued 6 December 2002 Resolved
OWS SAMPLE LINE IS WASTED AND LEAKING. MAKE PERMANTENT REPAIRS TO SATISFACTION OF CLASS LEGACY COMPONENT DESC: Oily Water Separator (15 ppm)
Condition: Unknown
Action required: 705 - Other - as specified
Due 31 January 2003
Resolved 20 May 2003
Resolution: THIS UNIT RECEIVED CLASS REPORT.
Engineering › Lubricating Oil Service System
Issued 6 December 2002 Resolved
OIL HEATER LOCATED ON PORT SIDE LOWER ENGINE ROOM IN LEAKING AND HAS A WASTED INLET PIPING. MAKE PERMANTENT REPAIRS TO SATISFACTION OF CLASS LEGACY COMPONENT DESC: HEATER
Condition: Unknown
Action required: 705 - Other - as specified
Due 31 January 2003
Resolved 23 May 2003
Resolution: This office received class report.
Fire Fighting
Issued 23 June 1999 Resolved
MAKE PERMANENT REPAIRS TO THE ENGINE ROOM EMERGENCY EXIT SELF-CLOSING DOOR.
Condition: Unknown
Due 23 January 2000
Resolved 23 January 2000
Fire Fighting
Issued 23 June 1999 Resolved
REPLACE #11 AND #12 FIRE HOSES.
Condition: Unknown
Due 27 June 1999
Resolved 27 June 1999
Engineering
Issued 23 June 1999 Resolved
PROVIDE WRITTEN CLASSIFICATION SOCIETY REPORT ATTESTING TO THE PROPER REPAIR AND OPERATION OF VESSEL'S MDE.
Condition: Unknown
Due 27 June 1999
Resolved 27 June 1999
Fire Fighting
Issued 27 December 1998 Resolved
Tending lines for fire suits not fireproof in non-adherence with SOLAS 74 (amended) II-2/17.2. Vessel to obtain fireproof tending lines prior to 27JAN99.
Condition: Unknown
Due 6 February 1999
Resolved 6 February 1999
Fire Fighting
Issued 27 December 1998 Resolved
Paintlocker CO2 system audible alarm removed, exposing unshielded electric-al wiring that creates risk of injury to crew in non-adherence with SOLAS 74 (amended) II-1/45.1.3 & II-2/5.1.6. Vsl to repair to satisfaction flag admin/auth. flag rep. NLT 27JAN99 & provide evidence of sat. repair to USCG
Condition: Unknown
Due 6 February 1999
Resolved 6 February 1999
Engineering
Issued 12 April 1998 Resolved
A deficiency of 33 CFR 155.380(b) in that the vessel's OWS alarm was inoperable._x001C_ _x001C_ *Correct prior to return to U.S. waters.*
Condition: Unknown
Due 27 December 1998
Resolved 27 December 1998
Navigation
Issued 12 April 1998 Resolved
A deficiency of 33 CFR 164.33 in that the vessel did not have British Admiralty chart #2603 on board and the vessels U.S. charts were not currently corrected._x001C_ *Correct prior to return to U.S. waters.*
Condition: Unknown
Due 27 December 1998
Resolved 27 December 1998

Ownership record