FERRY FLAT #1 is a 1966 passenger vessel (uninspected). The Coast Guard has recorded 28 inspections since 1985, most recently in July 2003, along with 23 deficiencies.

Records from 1985 to 2003. Most recent: inspection, 22 July 2003.

Built
1966
Last inspected
22 July 2003
Documentation
No Operation - PM · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

Flag
UNITED STATES
—
Maury page id
psix-45345

Inspections, by type

…with no type recorded4
Years with a record 15 calendar years (1985–2003)
The 28 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 23 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)90.1 ft × 28.1 ft × 4.0 ft
Registered tonnagegross 93 / net 93
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderMARKS STEEL PRODUCTS CO · OWENSBORO, KY, UNITED STATES · built 1966
Hull materialSteel
PropulsionNot recorded
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portPITTSBURGH, PA
Trade endorsementsCoastwise, unrestricted
DocumentationNo Operation - PM · issued 30 June 2004
Service, as the file records itPassenger (Uninspected)
Hull formunknown (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it93 - Regulatory (Subpart C or D), Net Ton
93 - Regulatory (Subpart C or D), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

MISSOURI Towing Vessel · MISLE 71631 · 24 April 1999 · activity 47759

Inspection history · 28

22 July 2003 Annual Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1840878
9 August 2002 Deficiency Check
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1679212
17 June 2002 Annual Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1628626
18 October 2001 Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1073902
11 May 2001 Hull Examination · COI Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1399554
24 April 1999 Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 47759
22 February 1996 Administrative
Administrative · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 884435
23 October 1995 Hull Examination
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1453167
8 November 1994 COI Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1392092
19 April 1994 Deficiency Check
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1165061
18 March 1994 Administrative
Administrative · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1165052
20 December 1993 Deficiency Check
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1159554
16 December 1993 Deficiency Check
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 849674
18 November 1993 Re-Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1425383
5 November 1992 Administrative
Administrative · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1134494
3 October 1992 Re-Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1248998
11 August 1992 Administrative
Administrative · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1264878
30 July 1992 Administrative
Administrative · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 961877
20 July 1992 Administrative
Administrative · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1259539
19 June 1992 Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1256903
21 February 1992 Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 951700
6 September 1991 COI Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 940449
26 September 1990 COI Inspection · Hull Examination
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1335152
25 October 1988 COI Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 888335
23 July 1987 COI Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1328179
6 October 1986 Deficiency Check
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1315426
25 August 1986 COI Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1302326
8 October 1985 COI Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 985653

Deficiency record · 23

Documentation › Logs/Records
Issued 22 July 2003 Resolved
Provide proof of participation in employee drug testing program. LEGACY COMPONENT DESC: Drug Test Records
Action required: 705 - Other - as specified
Due 24 August 2003
Resolved 25 July 2003
Documentation › Certificates/Documents
Issued 22 July 2003 Resolved
Provide proof of participation in CPR/First Aid training.
Action required: 705 - Other - as specified
Due 24 August 2003
Resolved 25 July 2003
Documentation › Logs/Records
Issued 22 July 2003 Resolved
Provide log of all firefighting and man overboard drills. LEGACY COMPONENT DESC: Logbook (official)
Action required: 705 - Other - as specified
Due 24 August 2003
Resolved 1 October 2003
Resolution: Deactivated COI.
Accommodation/Occupational Safety › Medical/First Aid
Issued 22 July 2003 Resolved
Renew expired items in first aid kit. LEGACY COMPONENT DESC: Medicine Chest
Action required: 705 - Other - as specified
Due 24 August 2003
Resolved 1 October 2003
Resolution: Deactivated COI.
Construction/Loadline › Markings
Issued 22 July 2003 Resolved
Renew faded draft marks. LEGACY COMPONENT DESC: Draft Marks/Indicating System
Due 24 August 2003
Resolved 1 October 2003
Resolution: Deactivated COI.
Fire Fighting › Fire Pumps
Issued 17 June 2002 Resolved
INSTALL PROPER THREAD FITTING ON FIRE AND BILGE PUMP #2.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 July 2002
Resolved 1 July 2002
Pollution Prevention/Response › Prevention Equipment
Issued 17 June 2002 Resolved
PROVIDE GARBAGE/OIL PLACARDS FOR VESSEL.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 July 2002
Resolved 1 July 2002
Navigation
Issued 17 June 2002 Resolved
PROVIDE 8TH DISTRICT NOTICE TO MARINERS.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 July 2002
Resolved 1 July 2002
Lifesaving › Work Vest
Issued 17 June 2002 Resolved
PROVIDE SAFETY LINE FOR MAN OVERBOARD RESCUER. LEGACY COMPONENT DESC: Safety Line
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 July 2002
Resolved 1 July 2002
Personnel › Training
Issued 17 June 2002 Resolved
PROVIDE CPR TRAINING FOR 50% OF CREW. LEGACY COMPONENT DESC: First Aid/CPR
Action required: 705 - Other - as specified
Due 17 July 2002
Resolved 9 August 2002
Documentation › Safety/Response Plans/Programs
Issued 17 June 2002 Resolved
POST SAFETY ORIENTATION PLACARD IN ACCORDANCE WITH 46 CFR 185.506.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 July 2002
Resolved 1 July 2002
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 17 June 2002 Resolved
PROVIDE FLASHLIGHT FOR EMERGENCY LIGHTING.
Condition: Unknown
Due 17 July 2002
Resolved 1 July 2002
Construction/Loadline
Issued 18 November 1993 Resolved
Make permanent repairs to starboard headlog and side shell where cracked and holed. Repairs are to follow good marine practice and be acceptable to the Coast Guard inspector.
Condition: Unknown
Due 18 November 1993
Resolved 18 November 1993
Construction/Loadline
Issued 18 November 1993 Resolved
In #7P void, crop and renew wasted diagonal in way of hatch.
Condition: Unknown
Due 18 November 1993
Resolved 18 November 1993
Unknown
Issued 18 November 1993 Resolved
Provide on the tow vessel a list of all personnel that are designated senior deck hands.
Condition: Unknown
Due 18 November 1993
Resolved 18 November 1993
Lifesaving
Issued 18 November 1993 Resolved
Conduct drills in the presence of a C.G. inspector utilizing the designatedsenior deck hand as the master.
Condition: Unknown
Due 18 November 1993
Resolved 18 November 1993
Construction/Loadline
Issued 3 October 1992 Resolved
Provide captive chains for all void covers.
Condition: Unknown
Due 3 October 1992
Resolved 3 October 1992
Accommodation/Occupational Safety
Issued 3 October 1992 Resolved
Provide an additional safety chain or cable across the vehicle ramp access.
Condition: Unknown
Due 3 October 1992
Resolved 3 October 1992
Fire Fighting
Issued 25 August 1986 Resolved
REMOUNT PORT FIRE EXTINGUISHER
Condition: Unknown
Due 25 August 1986
Resolved 25 August 1986
Accommodation/Occupational Safety
Issued 25 August 1986 Resolved
MAKE PERMANENT REPAIRS TO NUMEROUS RAIL STANCHIONS ON BOTH SIDES OF THE VESSEL AT THE DECK CONNECTION.
Condition: Unknown
Due 25 August 1986
Resolved 25 August 1986
Lifesaving
Issued 25 August 1986 Resolved
RESTENCIL VESSELS NAME ON THE FIRE AXE AND RING BUOYS.
Condition: Unknown
Due 25 August 1986
Resolved 25 August 1986
Construction/Loadline
Issued 25 August 1986 Resolved
MAKE PERMANENT REPAIRS TO A 5" FRACTURE IN THE PORT CORNER WRAPPER FROM THEDECK TURN DOWN 5".
Condition: Unknown
Due 25 August 1986
Resolved 25 August 1986
Lifesaving
Issued 25 August 1986 Resolved
PLACE DONNING INSTRUCTIONS AT BOTH LIFE JACKET LOCKERS.
Condition: Unknown
Due 25 August 1986
Resolved 25 August 1986

Ownership record