MAURY USCG vessel records Sign in
← All vessels

ARGYROULA

ARGYROULA is a 1997 freight ship. The Coast Guard has recorded 27 inspections since 1997, most recently in November 2010, along with 16 deficiencies and 1 operational control.

Records from 1997 to 2010. Most recent: inspection, 2 November 2010.

Built
1997
Last inspected
2 November 2010
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9159050 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
453597
Flag
MARSHALL ISLANDS
—
Maury page id
psix-453597

Inspections, by type

…with no type recorded15
Years with a record 12 calendar years (1997–2010)
The 27 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 16 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it15949 - Convention (Subpart B), Gross Ton
9603 - Convention (Subpart B), Net Ton
32568 - Displacement, Ton
26556 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 27

2 November 2010 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3883699
5 September 2007 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3044628
2 September 2007 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 3045533
9 August 2006 Type not recorded
No type recorded · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2736487
21 March 2006 ISPS II Exam · Ballast Water Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2606588
12 September 2005 Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 2490763
1 March 2005 Deficiency Check · Ballast Water Examination · MARPOL Annex I Examination · ILO-147 Exam · Random ISPS/MTSA/PSC · STCW 95 Exam · MARPOL Annex V Examination
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 2301405
18 October 2004 MARPOL Annex I Examination · Ballast Water Examination · Random ISPS/MTSA/PSC
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2223110
18 August 2004 ISPS II Exam
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2163549
26 June 2004 PII Safety Exam · ISPS III Exam · MARPOL Annex I Examination · Ballast Water Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2106858
29 August 2003 MARPOL Annex V Examination · Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1894860
19 August 2003 Administrative Inspection
Administrative · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 1876870
30 May 2003 Type not recorded
No type recorded · Sector Astoria · USCG Northwest District (CGD-NW) · Activity 1813451
10 April 2003 Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1771161
8 April 2003 Type not recorded
No type recorded · Sector Astoria · USCG Northwest District (CGD-NW) · Activity 1774144
28 February 2003 Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1747812
23 January 2003 Type not recorded
No type recorded · Sector Astoria · USCG Northwest District (CGD-NW) · Activity 1734423
4 January 2003 MARPOL Annex I Examination · Ballast Water Examination · Annual Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1725140
28 July 2002 Ballast Water Examination · Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1651303
11 October 2001 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 294911
10 June 2001 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 290779
22 August 2000 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 281286
23 October 1999 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 433822
1 September 1999 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 16767
22 March 1999 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 426543
14 September 1998 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 420449
4 March 1997 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 401208

Deficiency record · 16

Fire Fighting › Firemans Outfit › Lifeline
Issued 1 March 2005 Resolved
Lifeline found with no wire or not IAW SOLAS fire retardant standard.
Condition: Improper Installation
Due 1 March 2005
Resolved 1 March 2005
Resolution: Class approved & Master will check for fire retardant specs.
Fire Fighting › Means of Escape › Doorways
Issued 1 March 2005 Resolved
Plenum door from the machinery space & main deck forward egress door forward mid house deck door locked with padlock. Master & C/E will replace with seals or key glass encased for easy access.
Condition: Design Flaw
Due 1 March 2005
Resolved 1 March 2005
Resolution: Done prior to departure...
Electrical › Electrical Distribution System (emergency) › Non-conducting Deck Covering
Issued 1 March 2005 Resolved
Insulating matting in front of the emergency switchboard short of covering the whole switchboard length.
Condition: Improper Installation
Due 1 March 2005
Resolved 1 March 2005
Resolution: Done
Fire Fighting › Structural - Horizontal Zones › General
Issued 1 March 2005 Resolved
Cable deck penetrations compromise after cable replacements located engineroom forward control room overhead inboard side.
Condition: Improper Installation
Due 1 March 2005
Resolved 1 March 2005
Resolution: Done
Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 1 March 2005 Resolved
Wiring exposed to portable refrigerator electrical cable located port side control room in the engineroom. Electrical Hazard.
Condition: Placed in Improper Service
Due 1 March 2005
Resolved 1 March 2005
Resolution: C/E fixed wiring...
Lifesaving › Inflatable Liferafts › Hydrostatic Release Unit
Issued 26 June 2004 Resolved
Hydrostatic release unit of port side aft and starboard side aft liferafts have been modified to prevent manual release. Renew hydrostatic release units. SOLAS 74 III / 20.2
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 June 2004
Resolution: Class attended the vessel and verified the condition of the hydrostatic release unit to be in working order.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 26 June 2004 Resolved
Remove holdbacks on doors to galley. According to fire control plan, doors are class A and are required, by the plan, to be self-closing. SOLAS 74 II-2 / 17.1
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 June 2004
Resolution: Class verified that the hold back hooks were removed.
Fire Fighting › Firemans Outfit › Protective Clothing
Issued 26 June 2004 Resolved
Renew jackets of fireman suit. Clasps are inoperable on jackets presently on vessel. SOLAS 74 II-2 / 17.1
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 June 2004
Resolution: Class verified that the clasps were repaired.
Fire Fighting › Firemans Outfit › Quantity
Issued 26 June 2004 Resolved
Emergency gear lockers (total of 2) are locked, only three keys are available. Make firemans outfits readily accessible. SOLAS 74 II-2 / 17.4
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 June 2004
Resolution: Class had vessel place extra key in the ship''s office were it was readily accessible and recognized by crew.
Navigation › Collision/Grounding Avoidance
Issued 28 February 2003 Resolved
Repair RADAR as original prior to departure. Send copy of report to the fax number listed below. LEGACY COMPONENT DESC: Radar
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 February 2003
Resolution: Received copy of report from RADAR technician. Satisfactory repairs and tests completed.
Documentation › Logs/Records
Issued 28 February 2003 Resolved
Commence making entries into the Oil Record book as per the instructions found in appendix III to Annex I of MARPOL 73/78. LEGACY COMPONENT DESC: Oil Record Book
Action required: 15 - Rectify deficiencies by next port
Resolved 10 April 2003
Resolution: Reviewed Oil Record Book and found to be in accordance with appendix III to Annex I of MARPOL 73/78
Documentation › Certificates/Documents
Issued 28 February 2003 Resolved
Update the IOPP Certificate to reflect the capacity of the tank(s) for mixing oil residue with fuel oil (block 3.2.3). LEGACY COMPONENT DESC: IOPP Certificate
Action required: 15 - Rectify deficiencies by next port
Resolved 10 April 2003
Resolution: Reviewed the IOPP. Found to contain capacities in block 3.2.3
Fire Fighting › Miscellaneous Items
Issued 4 January 2003 Resolved
Conduct additional fire drill with all crew participating to the satisfaction of USCG Port State Inspector. SOLAS 74 amd III/19.
Due 4 January 2003
Resolved 4 January 2003
Resolution: Satisfactory fire drill conducted.
Electrical › Electric Generation Source (emergency)
Issued 4 January 2003 Resolved
Have emergency generator examined by Class (with survey report provided) prior to next U.S. Port call after sailing foreign. SOLAS 74 amd II-1/43. LEGACY COMPONENT DESC: Power Requirement
Condition: Unknown
Due 18 January 2003
Resolved 28 February 2003
Resolution: Received copy of Class report indicating Class performed satisfactory examination of emergency generator.
Pollution Prevention/Response › Prevention Equipment
Issued 4 January 2003 Resolved
Have oily water system and overboard content meter examined and tested to the satisfaction of Class. This must be completed prior to next U.S. Port call after sailing foreign. MARPOL 73/78 I/16. LEGACY COMPONENT DESC: Oily Water Separator (15 ppm)
Condition: Improper Installation
Due 18 January 2003
Resolved 28 February 2003
Resolution: Received copy of Class report indicating Class performed satisfactory examination and test of oily water system and overboard content meter.
Fire Fighting
Issued 14 September 1998 Resolved
HAVE CLASS ADDRESS INSTALLATION OF FIXED FIRE FIGHTING SYSTEM IN THE PAINT/LAMP STORAGE LOCKER. IAW SOLAS 74 AMENDED CHAP. II-2 RES 18.7._x001C_ PROVIDE CLASS REPORT TO USCG.
Condition: Unknown
Due 14 October 1998
Resolved 13 October 1998

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.