MAURY USCG vessel records Sign in
← All vessels

ANTICIPATION V

ANTICIPATION V is a 1997 passenger vessel (inspected). The Coast Guard has recorded 57 inspections since 1997, most recently in April 2026, along with 244 deficiencies, 3 operational controls and 5 casualty investigations between 2005 and 2024.

Records from 1997 to 2026. Most recent: inspection, 20 April 2026.

Built
1997
Last inspected
20 April 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDL4302
453617
Flag
UNITED STATES
367132910
Maury page id
psix-453617

Inspections, by type

…with no type recorded4
Years with a record 26 calendar years (1997–2026)
The 57 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)70.7 ft × 20.0 ft × 5.4 ft
Registered tonnagegross 51 / net 34
ITC dimensions (L × B × D)70.7 ft × 20.0 ft × 5.4 ft
ITC tonnagegross 133 / net 52
BuilderTSS FABR-H SKIPPERLINR-C · LA CROSSE WI · built 1997
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portFT MYERS, FL
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 14 March 2026 · expires 30 April 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it51 - Regulatory (Subpart C or D), Gross Ton
133 - Convention (Subpart B), Gross Ton
34 - Regulatory (Subpart C or D), Net Ton
52 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDL4302MMSI 367132910 · active · compulsorily equipped · granted 31 January 2020, expires 31 January 2030
WDD3544MMSI 367132910 · expired · compulsorily equipped · granted 3 August 2006, cancelled 8 October 2016
WCX6353MMSI not assigned · expired · compulsorily equipped · granted 25 July 1997, cancelled 29 September 2007 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 57

20 April 2026 Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8353490
5 March 2026 Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8320256
11 February 2026 Internal Structural Exam · Deficiency Check · Drydock Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8309160
22 December 2025 Internal Structural Exam · Drydock Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8286269
22 July 2025 Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8191901
28 October 2024 Deficiency Check · COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8026035
20 October 2024 Damage Survey
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8021602
19 October 2024 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8022157
16 May 2024 Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7913956
7 February 2024 Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7862123
27 February 2023 Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7642764
3 February 2023 Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7631607
11 March 2022 Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7463872
1 September 2021 Drydock Exam · Internal Structural Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7302496
14 April 2021 In-Service Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7175668
10 March 2021 Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7152596
23 December 2019 COI Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6876654
2 October 2019 Spot Check · Drydock Exam · Internal Structural Exam · Administrative Inspection · Examination of Repairs
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6826123
18 September 2018 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6542890
16 January 2018 Annual Inspection · Administrative Inspection · DAPI Audit
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6338209
20 October 2016 Annual Inspection · DAPI Audit
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6025612
20 October 2016 DAPI Audit
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6030491
15 September 2016 Drydock Exam · Internal Structural Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6001243
10 November 2015 Deficiency Check · Administrative Inspection · In-Service Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5760740
29 October 2014 Drydock Exam · Examination of Repairs · Deficiency Check · Internal Structural Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5014097
6 October 2014 DAPI Audit · Annual Inspection · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5011701
2 October 2014 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 4997452
28 June 2012 Internal Structural Exam · Drydock Exam · Examination of Repairs
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 4357483
15 February 2012 Deficiency Check · In-Service Inspection · Examination of Repairs
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 4245431
14 February 2012 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 4250531
14 September 2011 DAPI Audit · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 4144795
21 January 2009 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3397880
21 January 2009 Damage Survey
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3398081
25 August 2008 Annual Inspection · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3306053
29 April 2008 Deficiency Check · Hull Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3194357
19 July 2007 Deficiency Check · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2999593
17 August 2006 Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2751823
11 August 2006 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2744014
26 July 2006 Annual Inspection · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2727333
29 March 2006 Hull Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2611943
24 January 2006 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2572424
3 November 2005 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2560234
10 June 2005 COI Inspection · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2386306
15 July 2004 Administrative Inspection
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2134028
17 June 2003 In-Service Inspection · Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1822303
5 August 2002 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1655781
10 June 2002 Annual Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1628606
13 September 2001 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1073560
26 July 2001 Annual Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1418946
20 June 2001 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1426624
31 August 2000 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1053852
15 June 2000 COI Inspection · MARPOL Annex V Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1469310
22 July 1999 MARPOL Annex V Examination · Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1420173
15 June 1999 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1388827
23 July 1998 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1465980
9 July 1997 Initial Certification
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1467015
6 June 1997 Hull Examination · Initial Construction-Excluding Oversight
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1457468

Deficiency record · 244

09 - Working and Living Conditions › 092 - Working Conditions › Holds and tanks safety
Issued 20 April 2026 Resolved
Repairs or alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without the approval of the cognizant [name withheld] discovered that the sewage holding tank was in need of repair. Vsl owner is to submit plans to the local OCMI for approval prior to work. 46 CFR 176.700
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 May 2026
Resolved 28 April 2026
Resolution: Receieved repair plan for repairs. Repairs are being made all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 20 April 2026 Resolved
Where a flexible fill pipe section is necessary, suitable flexible tubing or hose having high resistance to salt water, petroleum oils, heat and vibration, may be used. Such hose must overlap metallic pipe ends at the least 11/2 times the pipe diameter and must be secured at each end by clamps. The flexible section must be accessible and as near the upper end of the fill pipe as practicable. When the flexible section is a nonconductor of electricity, the metallic sections of the fill pipe separated thereby must be joined by a conductor for protection against generation of a static charge when filling with fuel. There is no conductor to protect against the generation of static charge. 46CFR182.445(g)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 May 2026
Resolved 28 April 2026
Resolution: Received photo evidence of repairs being made. All sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 20 April 2026 Resolved
All fuel tanks must be electrically bonded to a common ground. Diesel fuel tank was not bonded to a common ground.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 May 2026
Resolved 28 April 2026
Resolution: Received photo evidence of repairs being made. All sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 20 April 2026 Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected and all required guards and protective devices must be in satisfactory condition. MI discovered the port main did not have a guard over rotating machinery. Make repairs to the satisfaction of the attending MI.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 May 2026
Resolved 28 April 2026
Resolution: Received photo evidence of repairs being made. All sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 20 April 2026 Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspection of electrical equipment and systems, including the following, Inspection of batteries for condition and security of stowage. MI discovered the stbd battery wire connection to be deteriorating. Make repairs to the satisfaction of the attending MI. 46 CFR 176.806
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 May 2026
Resolved 28 April 2026
Resolution: Received photo evidence of repairs being made. All sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 20 April 2026 Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspection of electrical equipment and systems, including the following, Inspection of all cable as far as practicable without undue disturbance of the cable or electrical apparatus. MI discovered cables in the Engine room on the SSDG to be zip tied at an angle of which is damaging the wires. Make repairs to the satisfaction of the attending MI.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 May 2026
Resolved 28 April 2026
Resolution: Received photo evidence of repairs being made. All sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 20 April 2026 Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations. MI discovered that the windings on the SSDG to be oil covered. Make repairs to the satisfaction of the attending MI. 46 CFR 176.830
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 May 2026
Resolved 28 April 2026
Resolution: Received photo evidence of repairs being made. All sat.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 4 December 2024 Resolved
07124 - The owner, managing operator, or a qualified servicing facility as applicable must conduct the following inspections and tests:portable extinguishers must be inspected and maintained in accordance with NFPA 10 and for fixed-gas fire extinguishing systems the owner or managing operator must provide satisfactory evidence of the required servicing to the marine inspector. All portable fire extinguishers and the fixed fire extinguishing system missed annual servicing. 46 CFR 176.810(b)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 December 2024
Resolution: received a servicing report for the fire extinguishing equipment.
12 - Dangerous Goods › N/A - No Subsystem › Other (tankers)
Issued 4 December 2024 Resolved
12199 - Shutoff valves, installed so as to close against the fuel flow, must be fitted in the fuel supply lines, one at the tank connection and one at the engine end of the fuel line to stop fuel flow when servicing accessories. The shutoff valve at the tank must be manually operable from outside the compartment in which the valve is located, preferably from an accessible position on the weather deck. When the fuel shutoffs were activated the valves did not fully close. 46 CFR 182.455(b)(4)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 December 2024
Resolution: Received a video showing proper operation of the fuel shutoffs.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 4 December 2024 Resolved
11117 - Each ring life buoy must be marked in clearly legible block capital letters with the vessel's name. The ring buoy on the forward part of the vessel was not marked with the name. 46 CFR 185.604(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 18 December 2024
Resolution: Received photographic evidence the ring buoy was marked with the vessel name.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 4 December 2024 Resolved
03106 - Each window must be capable of withstanding the maximum load from wave and wind conditions expected due to its location on the vessel and the authorized route of the vessel. The window on the main deck starboard side, amidships, was cracked. 46 CFR 177.1020
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 January 2025
Resolved 22 July 2025
Resolution: Received photographic evidence the vessel had a new window installed.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 20 October 2024 Resolved
Repairs or alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without the approval of the cognizant OCMI, except during an emergency. Repairs or alterations that affect the safety of the vessel include, but are not limited to: replacement, repair, or refastening of deck or hull planking, plating, and structural members; repair of plate or frame cracks. Vessel Operator reported damages to the bow and deck plating of the vessel after a collision with another vessel.
Action required: 705 - Other - as specified
Due 31 January 2025
Resolved 4 December 2024
Resolution: Repairs were inspected during the COI. All sat.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 7 February 2024 Resolved
A vessel on a lakes, bays, and sounds, or rivers route must carry: (1) Three hand red flare distress signals approved in accordance with § 160.021 in subchapter Q of this chapter, or other standard specified by the Commandant. Vessel missing 02 of the 06 required distress signals. 46CFR180.68(b)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 May 2024
Resolution: All distress signals onboard.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 7 February 2024 Resolved
Each rescue boat and ring life buoy must be marked with Type II retroreflective material approved in accordance with 46 CFR 164.018 or other standard specified by the Commandant. The arrangement of the retroreflective material applied after March 11, 1996, must be as specified by IMO Resolution A.658(16). New retro tape was needed on 01 life ring. 46CFR185.604(i)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 May 2024
Resolution: New retro tape was added.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 7 February 2024 Resolved
A carbon dioxide cylinder may not be inclined more than 30° from the vertical unless fitted with flexible or bent siphon tubes, in which case it may be inclined not more than 80° from the vertical. CO2 bottle siphon tube line should be installed at the 12 o'clock position as indicated on the bottle to ensure proper discharge of agent. Bottles were reinstalled oriented in different directions than what is required for horizontal installation. Provide documentation from fire suppression company that siphon tube is oriented in appropriate position.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 February 2024
Resolved 16 May 2024
Resolution: Documentation from third party for fire supression system was produced.
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage discharge connection
Issued 7 February 2024 Resolved
The operator must secure each Type III device in a manner which prevents discharge of sewage. Sewage ovbd discharge valve was found in the open position with no means of securing. Close valve and remove handle or padlock valve in closed position on ovbd discharge valve.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 May 2024
Resolution: overboard discharge valve was securely closed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 7 February 2024 Resolved
The number and identification of items stowed inside, and their sizes, must be marked in clearly legible letters and numbers on each container for life jackets. Re-label the number of life jackets stowed in each storage compartment.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 February 2024
Resolved 16 May 2024
Resolution: All life jacket stowage locations were properly labeled.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 27 February 2023 Resolved
A carbon dioxide cylinder may not be inclined more than 30° from the vertical unless fitted with flexible or bent siphon tubes, in which case it may be inclined not more than 80° from the vertical. CO2 bottles found to be installed incorrectly. 46 CFR 180.410(c)(7)
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 February 2023
Resolved 1 May 2023
Resolution: Verified deficiency via email.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 27 February 2023 Resolved
Each distribution panel or switchboard must be totally enclosed and of the dead front type. Marine inspector found multiple open slots on vessel's switchboard panel. 46 CFR 183.330(b)
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 February 2023
Resolved 24 March 2023
Resolution: Verified deficiency via email.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 27 February 2023 Resolved
Each connection to a conductor or terminal part of a conductor must be made within an enclosure. Junction box in aft compartment found with missing cover. 46 CFR 183.340(g)
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 February 2023
Resolved 24 March 2023
Resolution: Verified deficiency via email.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 27 February 2023 Resolved
Each connection to a conductor or terminal part of a conductor must be made within an enclosure. Electrical outlet in the galley was found with a missing cover. 46 CFR 183.340(g)
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 February 2023
Resolved 24 March 2023
Resolution: Verified deficiency via email.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 27 February 2023 Resolved
A dry exhaust pipe must be kept clear of, and suitably insulated or shielded from, combustible material. Generator turbo exhaust was missing lagging. 46 CFR 182.430(g)(1)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 March 2023
Resolved 24 March 2023
Resolution: Verified deficiency via email.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 27 February 2023 Resolved
A vessel must carry one floating waterlight, unless it is limited to daytime operation, in which case no floating waterlight is required. Each floating waterlight must be approved in accordance with § 161.010 in subchapter Q of this chapter. Waterlight found to be installed with incorrect battery type. 46 CFR 180.70(d)(1)
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 March 2023
Resolved 24 March 2023
Resolution: Verified deficiency via email.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 27 February 2023 Resolved
Each ring life buoy on a vessel must be approved in accordance with § 160.050 in subchapter Q of this chapter and be readily accessible for use. Ring buoy plug was missing. 46 CFR 180.70(b)(1)(2)
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 March 2023
Resolved 24 March 2023
Resolution: Verified deficiency via email.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 1 September 2021 Resolved
Repairs or alterations to hull, machinery, or equipment that effects sasfety of the vessel must not be made without the approval of the cognizant Officer in Charge Marine Inspection (OCMI) except in emergency. At the commencement of vessel hull and internal structure exam the following worklist items were outlined for repair or replacement as original. Provide repair plan proposal to OCMI for approval prior to commencing. 1. Both port and starboard side of vessel from top of cleat sockets to one foot below the waterline marking (white stripe on hull below chine) from stem to stern including stern corners wrapping around to the stern are to be cleaned down to bare metal including all ‘bondo’ and then gauged for thickness. Due to hull scantlings the allowable percentage of waste not to exceed 15%
Condition: Invalid
Action required: 60 - Rectify deficiencies prior to movement
Resolved 16 September 2021
Resolution: Repair proposal received and approved
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 1 September 2021 Resolved
Clean to bare metal and gauge where bottom is marked in grid pattern starting in center of marked area expanding out ward in 6” intervals up to 12 inches.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 December 2021
Resolution: Requirement cleared, repaired as origional
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 1 September 2021 Resolved
Clean off ‘bondo’ from both port and starboard embarkation decks and the entrance bulkhead IWO main accommodation area doors and framing to access damage.
Condition: Invalid
Action required: 60 - Rectify deficiencies prior to movement
Resolved 2 December 2021
Resolution: Requirement cleared, repaired as origional
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 1 September 2021 Resolved
Repair as original hole in bulkhead IWO bilge suction at keel on aft bulkhead of storage hold aft of forepeak.
Condition: Invalid
Action required: 60 - Rectify deficiencies prior to movement
Resolved 2 December 2021
Resolution: Requirement cleared, repaired as origional
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 1 September 2021 Resolved
Repair deck and bulkhead IWO embarkation areas to inclide hull plate and deck plate replacement as original.
Condition: Invalid
Action required: 60 - Rectify deficiencies prior to movement
Resolved 2 December 2021
Resolution: Requirement cleared, repaired as origional
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 1 September 2021 Resolved
Repair as original holed areas in 02 deck and 02 deck starboard base of bulkhead entering into 02 accommodation space.
Condition: Invalid
Action required: 60 - Rectify deficiencies prior to movement
Resolved 2 December 2021
Resolution: Requirement cleared, repaired as original
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 1 September 2021 Resolved
Remove paneling interior IWO atrium area to access steel bulkhead condition.
Condition: Invalid
Action required: 60 - Rectify deficiencies prior to movement
Resolved 2 December 2021
Resolution: Requirement cleared, repaired as original
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 1 September 2021 Resolved
Repair/replace as original the bases for the exhaust “buckets’
Condition: Invalid
Action required: 60 - Rectify deficiencies prior to movement
Resolved 2 December 2021
Resolution: Requirement cleared, repaired as original
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 1 September 2021 Resolved
Repair / replace as original aft engine room longitudinal and tabs where longitudinal connect to aft bulkhead outboard of port engine.
Condition: Invalid
Action required: 60 - Rectify deficiencies prior to movement
Resolved 2 December 2021
Resolution: Requirement cleared, repaired as original
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 1 September 2021 Resolved
Replace as original missing Structural Fire Protection in engine room areas where missing.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 2 December 2021
Resolution: Requirement cleared, repaired as original
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 1 September 2021 Resolved
Remove interior paneling and interferences in way of main deck windows to access wastage to the superstructure around window trim.
Condition: Invalid
Action required: 60 - Rectify deficiencies prior to movement
Resolved 2 December 2021
Resolution: Requirement cleared, repaired as original
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 1 September 2021 Resolved
Repair as original rotted exterior superstructure trim and drain areas above main deck windows.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 March 2022
Resolved 20 May 2024
Resolution: Did not witness any issues with the main deck windows during the inspection.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 1 September 2021 Resolved
Gauge under potable water tank.
Condition: Invalid
Action required: 60 - Rectify deficiencies prior to movement
Resolved 2 December 2021
Resolution: Requirement cleared,
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 1 September 2021 Resolved
Replace fore peak hatch gasket.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 2 December 2021
Resolution: Requirement cleared, repaired as original
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 1 September 2021 Resolved
Replace Starboard engine R/W suction valve
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 2 December 2021
Resolution: Requirement cleared, valve replaced in kind
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 1 September 2021 Resolved
Replace rubber section of over board drainage line for bar sink overboard drain and add an overboard skin valve.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 2 December 2021
Resolution: Requirement cleared, drain removed
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 1 September 2021 Resolved
Remove concrete patch around AC thru hull valve in Storage Void port side. Gauge hull plating IWO of thru hull for thickness.
Condition: Invalid
Action required: 60 - Rectify deficiencies prior to movement
Resolved 2 December 2021
Resolution: Requirement cleared, repaired as original
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 1 September 2021 Resolved
Repair hole on side shell plate in Storage void starboard forward corner.
Condition: Invalid
Action required: 60 - Rectify deficiencies prior to movement
Resolved 2 December 2021
Resolution: Requirement cleared, repaired as original
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 1 September 2021 Resolved
Repair / replace as original port aft corner longitudinal and tabs where longitudinal connect to aft bulkhead in steering compartment.
Condition: Invalid
Action required: 60 - Rectify deficiencies prior to movement
Resolved 2 December 2021
Resolution: Requirement cleared, repaired as original
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 1 September 2021 Resolved
Replace as original lower six longitudinal stringers in fore peak.
Condition: Invalid
Action required: 60 - Rectify deficiencies prior to movement
Resolved 2 December 2021
Resolution: Requirement cleared, repaired as original
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 1 September 2021 Resolved
Prior to carriage of passengers all repairs shall be completed to satisfaction of Officer In Charge Marine Inspection (OCMI)and a satisfactory seal trial completed.
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 2 December 2021
Resolution: Cleared all outstanding hull repair and witnessed satifactory sea trials.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 14 April 2021 Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury. Excess oil was found to be accumulated under the Generator. 46 CFR 182.100
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 April 2021
Resolution: Verififed oil accumluation had been cleared under generator and source of leak repaired.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 14 April 2021 Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury. Blow by hose on Generator was found to have excess oil and residue and improperly contained. 46 CFR 182.100
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 April 2021
Resolution: Verified blow by hose replaced and no longer leaking oil
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 14 April 2021 Resolved
Glass and other glazing material used in windows accessible to passengers and crew must be of material that will not break into dangerous fragments if fractured. Window in main accomodation area on port side aft was cracked and shattering. Replace broken window. 46CFR177.1010
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 April 2021
Resolution: Verified replacement window installed.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 10 March 2021 Resolved
Repair secondary fire/bilge PTO pump on starboard main engine.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 March 2021
Resolved 14 April 2021
Resolution: Witnessed proper operation of PTO pump
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 10 March 2021 Resolved
Replace missing cover for starboard main engine computer control box.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 March 2021
Resolved 11 March 2021
Resolution: New cover installed.
01 - Certificates & Documentation › 013 - Documents › Survey report file
Issued 10 March 2021 Resolved
Provide CO2 testing report from March 2021.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 March 2021
Resolved 11 March 2021
Resolution: Service report provided.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 10 March 2021 Resolved
Provide appropriate tide tables, charts, and coast pilot for intended area of operation (Baltimore, MD).
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 March 2021
Resolved 14 April 2021
Resolution: Vessel had onboard all required publications for operation within the Secotr MD AOR
10 - Safety of Navigation › N/A - No Subsystem › Radar
Issued 10 March 2021 Resolved
Repair or replace inoperable marine radar.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 March 2021
Resolved 14 April 2021
Resolution: Witnessed proper operation of both Marine Radars onboard.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 10 March 2021 Resolved
Repair inoperable spot light.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 March 2021
Resolved 11 March 2021
Resolution: Spot light repaired.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 10 March 2021 Resolved
Only 04 red hand flares were onboard. Provide a minimum of 06 flares (03 red and 03 orange, or 06 red).
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 March 2021
Resolved 11 March 2021
Resolution: New red hand flares onboard.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 10 March 2021 Resolved
Update first aid kit with ammonia inhalants.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 March 2021
Resolved 11 March 2021
Resolution: New ammonia inhalants onboard.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 10 March 2021 Resolved
Remove dead end wires in lazarette.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 March 2021
Resolved 11 March 2021
Resolution: Wires removed.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 23 December 2019 Resolved
FCC Safety Radio Authorization Certificate is expired. Provide renewed certificate.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 December 2019
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 23 December 2019 Resolved
FCC Bridge to Bridge Certificate is expired. Provide renewed certificate.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 December 2019
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 23 December 2019 Resolved
Servicing report for fire systems was not on board during the inspection. Operator was able to provide an email of the report prior to the conclusion of the inspection.
Action required: 10 - Deficiency Rectified
Resolved 23 December 2019
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 23 December 2019 Resolved
Flares must be stored in a water tight container marked "DISTRESS SIGNALS". Current storage is not water tight.
Action required: 705 - Other - as specified
Due 15 January 2020
Resolved 15 January 2020
Resolution: Water tight container properly marked is now being used to store flares.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 23 December 2019 Resolved
Vessel is required to have 6 day and 6 night flares. 3 day and 2 night flares are missing.
Action required: 10 - Deficiency Rectified
Resolved 23 December 2019
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 25 January 2018 Resolved
Add missing blanks electrical panel on main deck.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 1 February 2018
Resolved 2 February 2018
Resolution: Vessel operator added missing blanks electrical panel on main deck.
Electrical › Electrical Distribution System (service) › Wiring
Issued 25 January 2018 Resolved
Electrical wiring not properly secured or maintained in galley, main dining area and engine room.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 February 2018
Resolved 2 February 2018
Resolution: Electrical wiring properly secured in galley, main dining area and engine room.
Construction/Loadline › Structures › Superstructure
Issued 25 January 2018 Resolved
Replace broken windows on main deck; 04 total.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 10 April 2018
Resolved 3 July 2018
Resolution: Vessel replaced broken windows on main deck; 04 total
Engineering › Diesel Engine (auxiliary) › Turbocharger
Issued 25 January 2018 Resolved
Provide technician report or satisfactory testing of generator with fire pump running to simulate engine under load. Engine was emitting excessive smoke while under load.Potential turbocharger issue.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 February 2018
Resolution: Satisfactoryly tested generator with fire pump running to simulate engine under load.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 16 January 2018 Resolved
Vessel must undergo annual inspection prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 January 2018
Resolution: Annual inspection completed.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 20 October 2016 Resolved
stenciling is worn. re-stencile all 3 ring buoys.
Condition: Improper/Lack of Maintenance
Due 27 October 2016
Resolved 20 October 2016
Resolution: ring buoys now properly marked.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 20 October 2016 Resolved
Life jacket location marking is out of date. Update the actual amount of life jackets at the storage locations to reflect amount on board.
Condition: Improper/Lack of Maintenance
Due 27 October 2016
Resolved 20 October 2016
Resolution: storage location markings are now up to date and reflect the actual amount of life jackets on board the vessel and listed on the COI.
Construction/Loadline › Markings › Vessel Name/Home Port
Issued 20 October 2016 Resolved
Permanently mark the vessels name.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 October 2016
Resolution: Vessel's name is now properly marked on the stern.
Engineering › Shafting/Propeller Arrangements › Bearing
Issued 15 September 2016 Resolved
Renew P/S strut and P/S shaft tube cutlass bearings.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 15 September 2016
Resolved 29 September 2016
Resolution: All cutlass bearings renewed.
Construction/Loadline › Hull › Stiffener
Issued 15 September 2016 Resolved
Renew 03 gussets, one in lazerette on stern starboard side and two in sewage tank space (marked).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 September 2016
Resolved 29 September 2016
Resolution: All gussets renewed.
Construction/Loadline › Hull › Bottom Plating
Issued 15 September 2016 Resolved
Clean prep for inspection identified area of scaling in engine room, port side bottom plating. **Repair proposal submitted to insert an 18 X 18 plate to renew area of wasted hull**
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 September 2016
Resolved 29 September 2016
Resolution: New insert installed and NDT conducted to verify watertight intergrity.
Construction/Loadline › Hull › Longitudinal Frame
Issued 15 September 2016 Resolved
Renew fram in forepeak, starboard side second frame.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 September 2016
Resolved 29 September 2016
Resolution: Longitudinal frame in forpeak renewed.
Construction/Loadline › Structures › Deck Plating
Issued 15 September 2016 Resolved
Crop and renew to good metal idendified wasted areas in galley deck (marked in lazerette).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 September 2016
Resolved 29 September 2016
Resolution: Areas of wasted deck were cropped and renewed.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 10 November 2015 Resolved
Provide documentation of enrollment of all crew members in drug and alcohol program.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 November 2015
Resolved 30 November 2015
Resolution: Updated list provided.
Operations/Management › Drug and Alcohol Testing › Testing, Pre-employment
Issued 10 November 2015 Resolved
Provide documentation of pre-employment screening or consortium enrollment with test data.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 November 2015
Resolved 30 November 2015
Resolution: Updated list provided.
Lifesaving › Hand Flares › Expired
Issued 10 November 2015 Resolved
Provide 6 red hand flares.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 November 2015
Resolved 30 November 2015
Resolution: Red hand flares provided.
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 10 November 2015 Resolved
Provide up to date charts and publications.
Condition: Invalid
Action required: 705 - Other - as specified
Due 16 December 2015
Resolved 15 December 2015
Resolution: Observed satisfactory charts and pubs on board.
Navigation › Piloting/Steering › Magnetic Compass
Issued 10 November 2015 Resolved
Prove illumination of magnetic compass.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 November 2015
Resolved 30 November 2015
Resolution: Verified operation of illuminated compass.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 10 November 2015 Resolved
Prove operation of port navigation light and mast head light.
Condition: Design Flaw
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 November 2015
Resolved 30 November 2015
Resolution: Verified operation of navigation lights.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 10 November 2015 Resolved
Prove operation of waterlight.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 November 2015
Resolved 30 November 2015
Resolution: Verified operation of renewed water light.
Communications › Public Address System › Loudspeaker
Issued 10 November 2015 Resolved
Prove operation of all PA speakers.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 November 2015
Resolved 30 November 2015
Resolution: Verified operation of PA system.
Engineering › Steering Gear System › Trick Wheel
Issued 10 November 2015 Resolved
Repair/ renew cracked helm hub.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 16 December 2015
Resolved 15 December 2015
Resolution: Verified installation of helm with renewed hub and drive shaft.
Stability › Unintentional Flooding › General
Issued 10 November 2015 Resolved
Repair/ renew cracked potable water atnk.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 November 2015
Resolved 30 November 2015
Resolution: Potable water tank patched, and not leaking.
Communications › Alarms/Indicators › Engine RPM Gauge/Indicator
Issued 10 November 2015 Resolved
Stbd engine tachometer is reading erratically at idle. Voltmeter and oil pressure indicator are fluctuating as well. Operator to prove proper operation.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 December 2015
Resolved 2 December 2015
Resolution: Observed satisfactory operation of engine gauges and meters.
Construction/Loadline › Hull › Bottom Plating
Issued 29 October 2014 Resolved
Submit repair proposals for approval for holed/wasted areas of the hull identified by USCG Marine Inspector (port quarter, transom center line, port side of underwater body outboard of keel 1/3 length fwd of stern, port side underwater body outboard of the keel 1/3 length aft of the stern)
Action required: 705 - Other - as specified
Resolved 19 November 2014
Construction/Loadline › Hull › Bottom Plating
Issued 29 October 2014 Resolved
Grind all paint and coating from areas of the hull identified by USCG Marine Inspector and make availible for inspection
Action required: 705 - Other - as specified
Resolved 19 November 2014
Construction/Loadline › Hull › Hull Plating
Issued 29 October 2014 Resolved
Provide repair proposals for approval for missing/deteriorated longitudinal connection brackets in the steering space stbd side aft bulkhead, #2 void stbd side aft bulkhead, and #3 void stbd side aft bulkhead
Action required: 705 - Other - as specified
Resolved 1 December 2014
Construction/Loadline › Hull › Bottom Plating
Issued 29 October 2014 Resolved
Descale and gauge the bilges in the #2 and #3 void spaces 12" outboard of the CVK on port and stbd sides. These areas have fresh paint over the top of scale rust
Action required: 705 - Other - as specified
Resolved 19 November 2014
Construction/Loadline › Hull › Hull Plating
Issued 29 October 2014 Resolved
Provide gauging report from a qualified NDT tech for the areas identified by the USCG Marine Inspector (stbd quarter, stbd mid ship between the chine and W/L, stbd fwd, stbd fwd quarter, port fwd quarter, port forward between the chine and W/L)
Action required: 705 - Other - as specified
Resolved 19 November 2014
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 6 October 2014 Resolved
Properly renew topside ring buoy and battery. Battery must be IAW correct battery type as labeled on light casing.
Due 20 October 2014
Resolved 24 October 2014
Resolution: Topside ring buoy and battery renewed.
Construction/Loadline › Hull › Bottom Plating
Issued 3 July 2012 Resolved
Provide gauging of hull bottom from approx. 2' inboard of chin and 6' aft of bow stem where. pitted.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 July 2012
Construction/Loadline › Hull › Side Shell
Issued 3 July 2012 Resolved
Crop to good metal and repair as original wasted metal under rub rails
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 October 2012
Construction/Loadline › Hull › Bottom Plating
Issued 28 June 2012 Resolved
Make hull from boot stripe down available for USCG Inspection.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 July 2012
Construction/Loadline › Hull › Side Shell
Issued 28 June 2012 Resolved
Remove port and STBS rub rails and make available for USCG Inspection.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 October 2012
Construction/Loadline › Structures › Superstructure
Issued 28 June 2012 Resolved
Scale around all window frames port and STBD side upper and lower windows (pay close attention to window lip).
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 October 2012
Construction/Loadline › Structures › Superstructure
Issued 28 June 2012 Resolved
Make available for inspection port side superstructure interior IWO fwd windows where wasted.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 August 2012
Construction/Loadline › Hull › Bottom Plating
Issued 28 June 2012 Resolved
Crop to good metal and make repairs to #3 fwd port compartment hull where holed, port transom aprrox. 2" from hull plate where holed and port side shell just fwd of loading door below main deck where holed.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 October 2012
Construction/Loadline › Structures › Superstructure
Issued 28 June 2012 Resolved
Crop to good metal and make repairs to galley aft wall (super structure on transom).
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 October 2012
Stability › Watertight Integrity › General
Issued 28 June 2012 Resolved
Install gasket for forepeak scuttle (hatch).
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 November 2012
Construction/Loadline › Hull › Longitudinal Frame
Issued 28 June 2012 Resolved
Crop and renew holed aft port stringer under water heater #3 compartment.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 August 2012
Construction/Loadline › Hull › Bottom Plating
Issued 28 June 2012 Resolved
#3 compartment, remove scale center aft port bilge and remove all scale for inspection.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 August 2012
Electrical › Lighting (service) › Lighting Fixture
Issued 28 June 2012 Resolved
Mount light fixture in #3 compartment STBD aft.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 November 2012
Accommodation/Occupational Safety › Potable Water System › General
Issued 28 June 2012 Resolved
Make repairs to fresh water tank PVC and fiberglass patch in #4 compartment.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 November 2012
Construction/Loadline › Hull › Transverse Frame
Issued 28 June 2012 Resolved
Crop and renew holed center transverse frame between fuel and water tank #4 compartment.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 August 2012
Construction/Loadline › Hull › Longitudinal Frame
Issued 28 June 2012 Resolved
Crop and renew wasted longitudinal frame bracket port center aft bulkhead in #4 compartment.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 August 2012
Stability › Weathertight Integrity › General
Issued 28 June 2012 Resolved
Crop and renew wasted main deck port and stbd door frames fwd.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 October 2012
Construction/Loadline › Hull › Transverse Frame
Issued 28 June 2012 Resolved
Crop and renew transverse frame under starboard shaft in engine room.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 October 2012
Construction/Loadline › Structures › Superstructure
Issued 28 June 2012 Resolved
Crop to good metal all areas of superstructure (above main deck) identified with holes and make proper repairs.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 October 2012
Construction/Loadline › Hull › Bottom Plating
Issued 28 June 2012 Resolved
Provide repair proposal for all hull, frame and superstructure repairs.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 October 2012
Construction/Loadline › Hull › Bottom Plating
Issued 28 June 2012 Resolved
Complete anode calculations to determine if enough zinc is installed.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 October 2012
Engineering › Steering Gear System › Actuator
Issued 15 February 2012 Resolved
Provide tech report from Mathers certified technician on the cause of the port engine going full astern while in neutral. Provide in report corrective actions and any input from Mathers parent company.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 February 2012
Engineering › Steering Gear System › Actuator
Issued 15 February 2012 Resolved
In the presents of a USCG Marine Inspector complete tests of Mathers MicroCommander once repairs are made and tests are completed by tech.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 February 2012
Stability › Weathertight Integrity › General
Issued 14 September 2011 Resolved
Replace the two cracked windows, port side fwd.
Action required: 705 - Other - as specified
Due 23 September 2011
Resolved 27 September 2011
Accommodation/Occupational Safety › Ventilation › General
Issued 14 September 2011 Resolved
Engine room ventilation dampners are not fully closing. Prove proper operation of closure.
Action required: 705 - Other - as specified
Due 23 September 2011
Resolved 27 September 2011
Electrical › Electrical Distribution System (service) › Conductor
Issued 14 September 2011 Resolved
Remove or properly terminate dead-ended wires under bridge console.
Action required: 705 - Other - as specified
Due 23 September 2011
Resolved 27 September 2011
Engineering › Bilge Water Management System › Hose
Issued 14 September 2011 Resolved
Flex bilge discharge hose overboard from manifold does not met new "T" 46 CFR 182.510. Replace with hard pipe at next dry-dock.
Action required: 705 - Other - as specified
Resolved 5 December 2012
Communications › Public Address System › Announcing Station
Issued 14 September 2011 Resolved
Make public address speakers audible in all accommodation spaces.
Action required: 705 - Other - as specified
Due 23 September 2011
Resolved 27 September 2011
Engineering › Diesel Engine (propulsion-direct drive) › Block
Issued 21 January 2009 Resolved
Make permanent repairs and prove proper operation of Stbd main diesel engine prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 September 2009
Navigation › Piloting/Steering › Coast Guard Light List
Issued 25 August 2008 Resolved
Provide onboard current edition of the tidal currents, US Coast Pilot, US Coast Guard light list and current/updated/corrected charts.
Action required: 705 - Other - as specified
Due 2 September 2008
Resolved 3 September 2008
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 25 August 2008 Resolved
Update first aid kit IAW 46 CFR 160.041(b) and replace expired items.
Action required: 705 - Other - as specified
Due 2 September 2008
Resolved 3 September 2008
Deck/Cargo › Mooring/Anchoring › Anchor Shackle
Issued 25 August 2008 Resolved
Mouse shackle connecting anchor to anchor line.
Action required: 705 - Other - as specified
Due 2 September 2008
Resolved 3 September 2008
Navigation › Piloting/Steering › Deviation Table/Graph
Issued 25 August 2008 Resolved
Provide deviation table for magnetic compass.
Action required: 705 - Other - as specified
Due 2 September 2008
Resolved 3 September 2008
Deck/Cargo › Mooring/Anchoring › Mooring Line/Hawser
Issued 25 August 2008 Resolved
Replace chaffed mooring line FWD #1 and #2.
Action required: 705 - Other - as specified
Due 2 September 2008
Resolved 3 September 2008
Electrical › Electrical Distribution System (service) › Switch
Issued 25 August 2008 Resolved
Mount temperature controller for A/C in galley STBD side.
Action required: 705 - Other - as specified
Due 2 September 2008
Resolved 3 September 2008
Stability › Weathertight Integrity › General
Issued 25 August 2008 Resolved
Provide repair proposal for main deck greenhouse window, both P/S side upper window frame on main deck, water intrusion IWO windows port side staircase FWD leading to 2nd deck, bar 2nd deck IWO overhead and wheelhouse window framing.
Action required: 705 - Other - as specified
Due 2 September 2008
Resolved 3 September 2008
Electrical › Electrical Distribution System (service) › Wiring
Issued 25 August 2008 Resolved
Remove saturated wood consol and ensure space under consol is dry.
Action required: 705 - Other - as specified
Due 2 September 2008
Resolved 3 September 2008
Construction/Loadline › Hull › Transverse Frame
Issued 25 August 2008 Resolved
Provide proposal for wasted frame #2 in forepeak and wasted framing at bottom of door leading to soda locker.
Action required: 705 - Other - as specified
Due 2 September 2008
Resolved 3 September 2008
Electrical › Lighting (service) › Lighting Fixture
Issued 25 August 2008 Resolved
Replace/provide covers for eight light fixtures in soda locker.
Action required: 705 - Other - as specified
Due 2 September 2008
Resolved 3 September 2008
Fire Fighting › Fire Pumps › Capacity
Issued 25 August 2008 Resolved
Repair/replace gauge on fire pump to show 60 psi at the pump outlet.
Action required: 705 - Other - as specified
Due 2 September 2008
Resolved 3 September 2008
Stability › Weathertight Integrity › General
Issued 25 August 2008 Resolved
Repair/replace STBD window in greenhouse.
Action required: 705 - Other - as specified
Due 31 May 2009
Resolved 14 September 2009
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 29 April 2008 Resolved
Provide onboard a current Certificate of Documentation with correct owner address. COD expired on 31 Mar08.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 May 2008
Engineering › Sea-water System (primary cooling) › Piping
Issued 29 April 2008 Resolved
make repairs to leaking pipe on salt water pump in f/o tank void port side.
Action required: 705 - Other - as specified
Resolved 13 May 2008
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 29 April 2008 Resolved
Remove all oil from bilge in engin room and oil on hoses, generator and MDE's
Action required: 705 - Other - as specified
Resolved 2 May 2008
Construction/Loadline › Structures › Superstructure
Issued 29 April 2008 Resolved
Make proper repairs to wasted metal on fwd window frames, main deck top.
Action required: 705 - Other - as specified
Resolved 2 May 2008
Construction/Loadline › Hull › Weld
Issued 29 April 2008 Resolved
Remove coating from fwd weld stbd side hull (exterior) w/ wire wheel or brush and make ready for USCG inspection.
Action required: 705 - Other - as specified
Resolved 2 May 2008
Engineering › Bilge Water Management System › Strainer
Issued 29 April 2008 Resolved
Replace wasted strainer on bilge piping in 2nd compartment.
Action required: 705 - Other - as specified
Resolved 2 May 2008
Fire Fighting › Fixed CO2 Fire Extinguishing System › Tanks
Issued 18 July 2007 Resolved
Prior to the carriage of passengers provide report stating proper repairs to fix fire fighting system were completed and system is fully operational.
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 July 2007
Resolved 20 July 2007
Resolution: Received report that fixed fire fighting is fully operational.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 26 July 2006 Resolved
Provide current charts, light list and coast pilot.
Due 8 August 2006
Resolved 17 August 2006
Navigation › Piloting/Steering › Compass Deviation Table
Issued 26 July 2006 Resolved
Provide compass deviation table.
Due 8 August 2006
Resolved 18 August 2006
Electrical › Electrical Distribution System (service) › Wiring
Issued 26 July 2006 Resolved
Remove dead ended wires from beneath operating station and breaker cabinet main deck.
Due 8 August 2006
Resolved 17 August 2006
Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 26 July 2006 Resolved
Properly mount Moffat oven in galley.
Due 8 August 2006
Resolved 17 August 2006
Communications › Radio Communications › VHF Radiotelephone
Issued 26 July 2006 Resolved
Properly fill out radio distress placard.
Due 8 August 2006
Resolved 17 August 2006
Documentation › Certificates/Documents › FCC SSL
Issued 26 July 2006 Resolved
Provide valid FCC station license.
Due 8 August 2006
Resolved 17 August 2006
Communications › Radio Communications › EPIRB
Issued 26 July 2006 Resolved
Properly mount EPIRB in float free mount away from overhead obstructions prior to vessel operating outside rivers route. Vessel restricted to ICW until corrected.
Action required: 705 - Other - as specified
Resolved 17 August 2006
Resolution: See vessel note
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 26 July 2006 Resolved
Prove proper operation of rescue platform ensuring platform can not fall of vessel. prior to vessel operating outside rivers route. Vessel restricted to ICW until corrected.
Action required: 705 - Other - as specified
Resolved 17 August 2006
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 26 July 2006 Resolved
Prove proper operation of engine room vent closures.
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 July 2006
Resolved 27 July 2006
Engineering › Bilge Water Management System › Valve
Issued 26 July 2006 Resolved
Provide positive control valve for electrical sub pump in starboard shaft bilge.
Due 8 August 2006
Resolved 17 August 2006
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 29 March 2006 Resolved
Crop and Renew forward bow railing
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 24 April 2006
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 29 March 2006 Resolved
Crop and Renew railing on boarding ramp.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 24 April 2006
Construction/Loadline › Structures › Superstructure
Issued 29 March 2006 Resolved
Properly mount/install navigational mast and radar as proposed in company's repair proposal.
Action required: 705 - Other - as specified
Resolved 19 July 2007
Construction/Loadline › Hull › Longitudinal Frame
Issued 29 March 2006 Resolved
Replace 5 wasted gussetts on port side located near collision bulkhead in #1 void space.
Action required: 705 - Other - as specified
Resolved 14 April 2006
Construction/Loadline › Hull › Longitudinal Frame
Issued 29 March 2006 Resolved
Replace 2 sections of frame members and 1 full frame member located forward of collision bulkhead in #1 void space.
Action required: 705 - Other - as specified
Resolved 14 April 2006
Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 29 March 2006 Resolved
Remove/properly install overhead lights located throughout all voids on vessel.
Action required: 705 - Other - as specified
Resolved 14 April 2006
Accommodation/Occupational Safety › Potable Water System › General
Issued 29 March 2006 Resolved
Properly mount PVC piping in #3 void space
Action required: 705 - Other - as specified
Resolved 14 April 2006
Construction/Loadline › Hull › Weld
Issued 29 March 2006 Resolved
Properly weld cracked weld located forward stbd side in #3 void.
Action required: 705 - Other - as specified
Resolved 10 April 2006
Construction/Loadline › Hull › Longitudinal Frame
Issued 29 March 2006 Resolved
Crop and Renew strength members located in void space #2 as original.
Action required: 705 - Other - as specified
Resolved 14 April 2006
Construction/Loadline › Hull › Longitudinal Frame
Issued 29 March 2006 Resolved
Crop and renew as original frame members in void space #4 on starboard side.
Action required: 705 - Other - as specified
Resolved 14 April 2006
Construction/Loadline › Hull › Weld
Issued 29 March 2006 Resolved
Weld top of support members on welded patch in #2 void space.
Action required: 705 - Other - as specified
Resolved 10 April 2006
Construction/Loadline › Hull › Longitudinal Frame
Issued 29 March 2006 Resolved
Crop and renew as original frame member located by ladder on top in #4 void space.
Action required: 705 - Other - as specified
Resolved 14 April 2006
Engineering › Diesel Engine (propulsion-direct drive) › Turbocharger
Issued 29 March 2006 Resolved
Excessive engine oil blow by starboard turbo seal.
Action required: 705 - Other - as specified
Resolved 24 April 2006
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 29 March 2006 Resolved
Replace port exhaust baffle and properly mount
Action required: 705 - Other - as specified
Resolved 14 April 2006
Electrical › Electrical Distribution System (service) › Wiring
Issued 29 March 2006 Resolved
Replace frayed electrical wire located near port exhaust
Action required: 705 - Other - as specified
Resolved 14 April 2006
Engineering › Bilge Water Management System › Pump
Issued 29 March 2006 Resolved
Replace positive control valve on electric bilge pump located in engineroom.
Action required: 705 - Other - as specified
Resolved 14 April 2006
Fire Fighting › Miscellaneous Items › Insulation (Penetration of Oil/Oil Vapors)
Issued 29 March 2006 Resolved
Replace missing insulation to overhead in engine room.
Action required: 705 - Other - as specified
Resolved 14 April 2006
Engineering › Sea-water System (primary cooling) › Valve
Issued 29 March 2006 Resolved
Replace starboard main valve to main sea suction.
Action required: 705 - Other - as specified
Resolved 14 April 2006
Fire Fighting › Fire Main › Material
Issued 29 March 2006 Resolved
Replace overboard hose on firemain with proper hose.
Action required: 705 - Other - as specified
Resolved 14 April 2006
Pollution Prevention/Response › Prevention Equipment › Sewage System Tank
Issued 29 March 2006 Resolved
Provide means to indicate sewage tank is 3/4 full.
Action required: 705 - Other - as specified
Resolved 24 April 2006
Pollution Prevention/Response › Prevention Equipment › Sewage System Piping
Issued 29 March 2006 Resolved
Properly mount PVC piping in #5 void space.
Action required: 705 - Other - as specified
Resolved 14 April 2006
Pollution Prevention/Response › Prevention Equipment › Sewage System Piping
Issued 29 March 2006 Resolved
Provide proper cap on hose and remove highlighter in hose located in #5 void space.
Action required: 705 - Other - as specified
Resolved 14 April 2006
Electrical › Electrical Distribution System (service) › Wiring
Issued 29 March 2006 Resolved
Remove dead-ended wires aft of steering ram.
Action required: 705 - Other - as specified
Resolved 14 April 2006
Construction/Loadline › Hull › Longitudinal Frame
Issued 29 March 2006 Resolved
Crop and renew as original indentation located in #5 void space.
Action required: 705 - Other - as specified
Resolved 14 April 2006
Pollution Prevention/Response › Prevention Equipment › Sewage System Piping
Issued 29 March 2006 Resolved
Properly mount sewage discharge piping.
Action required: 705 - Other - as specified
Resolved 14 April 2006
Accommodation/Occupational Safety › Potable Water System › General
Issued 29 March 2006 Resolved
Make proper repairs to water heater located in void space #5
Action required: 705 - Other - as specified
Resolved 14 April 2006
Electrical › Electrical Distribution System (service) › Wiring
Issued 29 March 2006 Resolved
Remove all extension cords located in galley.
Action required: 705 - Other - as specified
Resolved 14 April 2006
Accommodation/Occupational Safety › Refrigeration (air conditioning) › General
Issued 29 March 2006 Resolved
Properly mount AC compressor located in galley.
Action required: 705 - Other - as specified
Resolved 24 April 2006
Construction/Loadline › Hull › Longitudinal Frame
Issued 29 March 2006 Resolved
Crop and Renew longitudinal frame member as original located above port exhasut in engineroom.
Action required: 705 - Other - as specified
Resolved 14 April 2006
Construction/Loadline › Structures › Superstructure
Issued 29 March 2006 Resolved
Crop and renew as original to good metal all port and aft starboard bulworth near all cleats.
Action required: 705 - Other - as specified
Resolved 14 April 2006
Construction/Loadline › Structures › Superstructure
Issued 29 March 2006 Resolved
Weld multiple holes on starboard side before replacing the rubrail.
Action required: 705 - Other - as specified
Resolved 14 April 2006
Construction/Loadline › Hull › Longitudinal Frame
Issued 29 March 2006 Resolved
Crop and Renew as original inset aft starboard and frame member supporting inset in enginroom located in the corner of the space.
Action required: 705 - Other - as specified
Resolved 14 April 2006
Construction/Loadline › Structures › Superstructure
Issued 29 March 2006 Resolved
Properly repair 4 window posts on starboard side.
Action required: 705 - Other - as specified
Resolved 10 April 2006
Construction/Loadline › Structures › Superstructure
Issued 29 March 2006 Resolved
Properly repair 1 window post on port side.
Action required: 705 - Other - as specified
Resolved 10 April 2006
Construction/Loadline › Hull › Bottom Plating
Issued 29 March 2006 Resolved
Make bottom available for inspection.
Action required: 705 - Other - as specified
Resolved 3 April 2006
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 29 March 2006 Resolved
Provide report on propellers and shafts.
Action required: 705 - Other - as specified
Resolved 26 April 2006
Construction/Loadline › Hull › Bottom Plating
Issued 29 March 2006 Resolved
Provide gauging report for 24 areas on starboard side of the hull and 22 areas on the port.
Action required: 705 - Other - as specified
Resolved 5 April 2006
Construction/Loadline › Hull › Weld
Issued 29 March 2006 Resolved
Repair washed out weld on outerbody of the hull
Action required: 705 - Other - as specified
Resolved 14 April 2006
Communications › Radio Communications › EPIRB
Issued 10 June 2005 Resolved
Provide an EPIRB in accordance with 46CFR180.205 Prior to carrying Passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 June 2005
Documentation › Certificates/Documents › FCC SSL
Issued 10 June 2005 Resolved
Provide Safety Radiotelepohny Certificate
Due 1 July 2005
Resolved 1 July 2005
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 10 June 2005 Resolved
Porivde p to dat 1st Kit
Due 1 July 2005
Resolved 1 July 2005
Engineering › Sea-water System (primary cooling) › Piping
Issued 10 June 2005 Resolved
Double Calmp and properly support Exhuast cooling hose.
Due 1 July 2005
Resolved 1 July 2005
Construction/Loadline › Structures › Superstructure
Issued 10 June 2005 Resolved
Replace broken Bridge window.
Due 1 July 2005
Resolved 1 July 2005
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 9 March 2004 Resolved
Renew lifering line and line to float light.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 March 2004
Engineering › Bilge Water Management System › Hose
Issued 9 March 2004 Resolved
Renew flexible hose at fire pump/ bilge discharge at side shell.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 March 2004
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 9 March 2004 Resolved
Prove CO2 fire suppression system is intact and ready for operation (service report)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 March 2004
Engineering › Bilge Water Management System › Pump
Issued 9 March 2004 Resolved
Provide hand bilge pump with min. of 5 gals per minute
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 March 2004
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 9 March 2004 Resolved
Provide tourniqutte for first aid kit.
Due 9 April 2004
Resolved 12 March 2004
Electrical › Electric Generation Source (service) › Panelboard
Issued 9 March 2004 Resolved
Repair/replace voltage guage for genset.
Due 9 April 2004
Resolved 12 March 2004
Communications › Alarms/Indicators › Propeller Revolutions Rate Indicator
Issued 8 March 2004 Resolved
Repair/replace starboard main engine tachmeter.
Due 8 April 2004
Resolved 9 March 2004
Electrical › Electric Supply System (service) › Cable
Issued 8 March 2004 Resolved
Make safe dead ended cable or remove. (lazerette).
Due 8 April 2004
Resolved 12 March 2004
Construction/Loadline › Penetrations › Valve Flange
Issued 8 December 2003 Resolved
Present thru hull valves for examination.
Action required: 705 - Other - as specified
Due 8 January 2004
Resolved 7 January 2004
Documentation › Certificates/Documents › Certificate of Inspection
Issued 8 December 2003 Resolved
Present vessel for in-service inspection to verifiy compliance with COI.
Due 8 January 2004
Resolved 9 March 2004
Construction/Loadline › Hull › Hull Plating
Issued 25 August 2003 Resolved
Crop and renew bottom plate as marked.
Action required: 705 - Other - as specified
Due 25 September 2004
Resolved 8 December 2003
Construction/Loadline › Hull › Hull Plating
Issued 25 August 2003 Resolved
Make repairs to staboard aft transom corner where damaged.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 25 September 2003
Resolved 8 December 2003
Engineering › Bilge Water Management System › Piping
Issued 25 August 2003 Resolved
Prove all bilge suctions.
Due 25 September 2003
Resolved 9 March 2004
Communications › Alarms/Indicators › Bilge Alarm
Issued 25 August 2003 Resolved
Prove all bilge alarms.
Due 25 September 2003
Resolved 9 March 2004
Construction/Loadline › Markings › Draft Marks/Indicating System
Issued 25 August 2003 Resolved
Provide draft marks or loading marks.
Due 25 September 2003
Resolved 8 December 2003
Construction/Loadline › Structures › Superstructure
Issued 25 August 2003 Resolved
Repair broken window at strarboard bow.
Due 25 September 2003
Resolved 9 March 2004
Construction/Loadline › Hull › Bottom Plating
Issued 27 June 2003 Resolved
Conduct Hull guaging of entire hull from chine to chine, bow to stern
Due 27 July 2003
Resolved 27 June 2003
Construction/Loadline › Structures › Door
Issued 27 June 2003 Resolved
Properly repair embarkation doors on port and starboard side.
Due 27 July 2003
Resolved 8 December 2003
Construction/Loadline › Hull › Bottom Plating
Issued 27 June 2003 Resolved
Submit repair proposal for repair of wasted areas of hull.
Due 27 July 2003
Resolved 25 August 2003
Construction/Loadline › Hull › Hull Plating
Issued 17 June 2003 Resolved
Remove all paint from exterior hull from stem to tern and from port chine to stbd chine to facilitate inspection.
Action required: 705 - Other - as specified
Due 23 June 2003
Resolved 25 August 2004
Construction/Loadline › Hull › Bottom Plating
Issued 17 June 2003 Resolved
Submit original scantlings plans for review.
Due 17 July 2003
Resolved 23 July 2003
Accommodation/Occupational Safety › Potable Water System › General
Issued 17 June 2003 Resolved
Properly repair both water heaters to cover heating elements.
Due 17 July 2003
Resolved 8 March 2004
Accommodation/Occupational Safety › Occupational Safety
Issued 10 June 2002 Resolved
Re-install MDE protection guards over pulley system. LEGACY COMPONENT DESC: Guards for Exposed Hazards
Due 20 June 2002
Resolved 22 July 2002
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 10 June 2002 Resolved
Provide documentation of use of flexible hose or bent siphon tube on fixed CO2 system (80 degree inclined installation). LEGACY COMPONENT DESC: Piping
Due 14 June 2002
Resolved 22 July 2002
Fire Fighting › Ventilation Systems
Issued 10 June 2002 Resolved
Label fixed fire-fighting ventilation closure. LEGACY COMPONENT DESC: Operating Controls
Due 14 June 2002
Resolved 22 July 2002
Construction/Loadline › Structures
Issued 10 June 2002 Resolved
Renew gasket on fwd. chainlocker. LEGACY COMPONENT DESC: Manhole
Due 20 June 2002
Resolved 22 July 2002
Construction/Loadline › Markings
Issued 10 June 2002 Resolved
Provide permanent draft marks. LEGACY COMPONENT DESC: Draft Marks/Indicating System
Due 30 June 2003
Resolved 22 July 2002
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 10 June 2002 Resolved
Install correct piping on fixed CO2 system. LEGACY COMPONENT DESC: Piping
Due 10 June 2002
Resolved 22 July 2002
Lifesaving › Embarkation Appliances/Stations
Issued 10 June 2002 Resolved
Provide MOB retrival ladder with drop down platform. LEGACY COMPONENT DESC: Steps
Due 10 September 2002
Resolved 5 August 2002
Navigation › Collision/Grounding Avoidance
Issued 10 June 2002 Resolved
Provide 12 inch bell.
Due 14 June 2002
Resolved 22 July 2002
Navigation › Collision/Grounding Avoidance
Issued 10 June 2002 Resolved
Relocate Port and Stbd. floodlights to enable correct arc of visibility on side lights. LEGACY COMPONENT DESC: Navigation Lights
Due 30 June 2002
Resolved 22 July 2002
Communications › Audible Communications
Issued 10 June 2002 Resolved
Provide additional PA speaker in galley.
Due 30 June 2002
Resolved 22 July 2002
Construction/Loadline › Structures
Issued 10 June 2002 Resolved
Provide securing device for forward hatch. LEGACY COMPONENT DESC: Manhole
Due 30 June 2002
Resolved 22 July 2002
Fire Fighting › Fire Main
Issued 10 June 2002 Resolved
Install plumbing for additional fire pump.
Due 24 June 2002
Resolved 29 July 2002
Accommodation/Occupational Safety
Issued 26 July 2001 Resolved
Sea rails missing on hotplates
Condition: Unknown
Due 29 August 2001
Resolved 4 September 2001
Electrical
Issued 26 July 2001 Resolved
Emergency lighting on upper deck lounge is defective
Condition: Unknown
Due 29 August 2001
Resolved 4 September 2001
Engineering
Issued 26 July 2001 Resolved
Vital system piping is not IAW Current regulations.
Condition: Unknown
Due 26 July 2001
Resolved 26 July 2001
Electrical
Issued 26 July 2001 Resolved
Lighting system in liquor hold requires permenant electrical wiring.
Condition: Unknown
Due 29 August 2001
Resolved 4 September 2001
Fire Fighting
Issued 26 July 2001 Resolved
No ventilation closures in engine room for fixed fire fighting system
Condition: Unknown
Due 26 July 2001
Resolved 26 July 2001
Accommodation/Occupational Safety
Issued 26 July 2001 Resolved
No garbage disposal log maintained.
Condition: Unknown
Due 29 August 2001
Resolved 4 September 2001
Lifesaving
Issued 26 July 2001 Resolved
Vessel requires hoisting davit for life sling
Condition: Unknown
Due 29 August 2001
Resolved 4 September 2001
Construction/Loadline
Issued 26 July 2001 Resolved
Vessel has a water intrusion on the port side of the engine room when it rains.
Condition: Unknown
Due 30 August 2001
Resolved 4 September 2001
Lifesaving
Issued 26 July 2001 Resolved
Galley appliances are not secured for sea.
Condition: Unknown
Due 29 August 2001
Resolved 4 September 2001
Fire Fighting
Issued 15 June 2000 Resolved
Prior to the carriage of passengers, move portable fire extinguisher behindbar on second deck.
Condition: Unknown
Due 15 June 2000
Resolved 15 June 2000
Lifesaving
Issued 15 June 2000 Resolved
Prior to 30Jun00, replace retroreflective tape, as discussed, on all ring life buoy's.
Condition: Unknown
Due 15 June 2000
Resolved 15 June 2000
Lifesaving
Issued 15 June 2000 Resolved
Prior to 30Jun00, post maximum number of passengers for upper deck on the FWD ladder.
Condition: Unknown
Due 15 June 2000
Resolved 15 June 2000
Lifesaving
Issued 15 June 2000 Resolved
Prior to 15Jul00, provide First Aid/Red Cross "CPR" cards fot 50% of the marine crew.
Condition: Unknown
Due 15 June 2000
Resolved 15 June 2000
Documentation
Issued 23 July 1998 Resolved
PROVIDE FCC SAFETY CERTIFICATE._x001C_ _x001C_
Condition: Unknown
Due 26 August 1998
Resolved 12 September 1998
Documentation
Issued 23 July 1998 Resolved
PROVIDE FCC OPERATOR'S PERMIT._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 26 August 1998
Resolved 12 September 1998
Engineering
Issued 23 July 1998 Resolved
PROVIDE PROOF OF PROPER VENTILATION IN FUEL TANK SPACE._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 19 August 1998
Resolved 20 August 1998
Lifesaving
Issued 9 July 1997 Resolved
INSTALL AND DEMONSTRATE PROPER OPERATION OF RESCUE BOAT.
Condition: Unknown
Due 23 February 1998
Resolved 23 February 1998
Documentation
Issued 9 July 1997 Resolved
PROVIDE VALID SAFETY RADIO TELEPHONY CERTIFICATE. VESSEL'S ROUTE IS RESTRICTED TO NOT MORE THAN 1000 FEET FROM SHORE UNTIL CERTIFICATE IS PROVIDED.
Condition: Unknown
Due 1 January 1998
Resolved 17 February 1998

Casualty record · 5

3 November 2005Routine · role: Involved in a Marine Casualty · at 3RD AVENUE BRIDGE · activity 2560234
21 January 2009Routine · role: Involved in a Marine Casualty · activity 3397880
14 February 2012Routine · role: Involved in a Marine Casualty · activity 4250531
7 February 2013Routine · role: Involved in a Marine Casualty · activity 4533918
19 October 2024Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 2 injured · activity 8022157
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.