TOM SAWYER

TOM SAWYER is a 1966 passenger vessel (inspected). The Coast Guard has recorded 125 inspections since 1985, most recently in April 2026, along with 250 deficiencies, 1 operational control and 2 casualty investigations between 2003 and 2014.

Records from 1985 to 2026. Most recent: inspection, 3 April 2026.

Built
1966
Last inspected
3 April 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDG5963
Flag
UNITED STATES
367552120
Maury page id
psix-45369

Inspections, by type

…with no type recorded11
Years with a record 39 calendar years (1985–2026)
The 125 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)83.1 ft × 27.2 ft × 5.4 ft
Registered tonnagegross 99 / net 67
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderDUBUQUE BOAT & BOILER CO · DUBUQUE, IA, UNITED STATES · built 1966
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portST LOUIS, MO
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 6 September 2025 · expires 30 September 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it99 - Regulatory (Subpart C or D), Gross Ton
67 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDG5963MMSI 367552120 · active · compulsorily equipped · granted 14 September 2022, expires 31 October 2032
WX7536MMSI not assigned · cancelled · compulsorily equipped · granted 3 October 1995, cancelled 13 July 2001
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 125

3 April 2026 Annual Inspection · Vessel Attendance · MTSA Verification · Deficiency Check · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 8323203
8 January 2026 Damage Survey · Administrative Inspection · Vessel Attendance · Examination of Repairs · Deficiency Check
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 8291781
25 November 2025 Administrative Inspection · In-Service Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 8273547
11 June 2025 Deficiency Check · Inclining Experiment · Damage Survey · Administrative Inspection · Examination of Repairs
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 8157467
3 March 2025 Administrative Inspection · Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 8083513
13 February 2025 Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 8079236
23 January 2025 Examination of Repairs · Damage Survey · Administrative Inspection · In-Service Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 8064948
15 May 2024 Deficiency Check
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 7913675
10 May 2024 Damage Survey · Examination of Repairs
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7909929
15 February 2024 MTSA Verification · Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7859592
30 May 2023 In-Service Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7700581
19 May 2023 Deficiency Check
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7692200
20 March 2023 Administrative Inspection · Examination of Repairs
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7653919
14 February 2023 Deficiency Check · Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7636509
8 February 2023 Damage Survey
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7635176
4 January 2023 Damage Survey · Examination of Repairs
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7617084
1 March 2022 Deficiency Check · COI Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7384707
16 June 2021 Inclining Experiment · Deficiency Check
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7215318
6 April 2021 Deficiency Check · Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7164892
7 December 2020 Deficiency Check · Examination of Repairs · Damage Survey
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7108109
19 December 2019 Annual Inspection · Internal Structural Exam · Examination of Repairs · Drydock Exam · Deficiency Check · MTSA Verification · Damage Survey
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6877304
6 September 2019 Administrative Inspection · Damage Survey
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6805655
12 February 2019 Deficiency Check · Annual Inspection · MTSA Verification · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6616825
17 January 2018 Deficiency Check · Administrative Inspection · MTSA Verification · Plan Review (Other than "T") · Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6344144
14 September 2017 Administrative Inspection · Deficiency Check
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6269266
2 February 2017 MTSA Verification · Administrative Inspection · Deficiency Check · COI Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6041805
14 November 2016 Administrative Inspection · Deficiency Check · Examination of Repairs
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6041483
3 May 2016 DAPI Audit · Deficiency Check
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 5909410
16 February 2016 Deficiency Check · Administrative Inspection · Annual Inspection · Examination of Repairs · MTSA Verification
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 5815916
10 February 2012 COI Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 4226263
12 January 2012 In-Service Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 4223927
4 January 2011 MTSA Verification · Annual Inspection · DAPI Audit · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3920271
24 February 2010 DAPI Audit · Annual Inspection · Deficiency Check
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3685642
28 December 2009 Hull Examination · Internal Structural Exam
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3655890
23 July 2009 MTSA Verification
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3543329
24 February 2009 Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3423263
29 April 2008 DAPI Audit · Deficiency Check
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3195063
9 April 2008 DAPI Audit · MTSA Verification · Annual Inspection · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3167549
10 March 2008 Administrative Inspection
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3161601
3 December 2007 Plan Review (Other than "T")
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3108641
11 April 2007 MTSA Verification · COI Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 2900931
11 October 2006 Construction Oversight · Plan Review (Other than "T")
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 2798445
13 March 2006 Deficiency Check · Administrative Inspection · MTSA Verification · Annual Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2595238
13 March 2006 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2601797
13 March 2006 Plan Review (Other than "T")
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2601826
6 February 2006 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2561568
15 March 2005 Annual Inspection · Examination of Repairs · Deficiency Check · MTSA Verification
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2311037
25 January 2005 In-Service Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2280593
6 December 2004 Examination of Repairs
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2254496
1 November 2004 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2289428
5 October 2004 Hull Examination · Deficiency Check · Examination of Repairs
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2214302
6 April 2004 Annual Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2038233
21 May 2003 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1799285
15 May 2003 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1866334
21 April 2003 Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1770562
23 October 2002 Security Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1696061
3 June 2002 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1624038
11 April 2002 COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1603557
17 January 2002 Construction Oversight
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1479590
30 November 2001 Plan Review "T" Boat
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1075815
17 April 2001 Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1417264
13 June 2000 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1053244
17 April 2000 Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1467663
23 March 2000 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 690503
12 November 1999 Deficiency Check · Hull Examination
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1415279
11 October 1999 Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 810826
1 July 1999 Excursion Permit
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1119361
14 April 1999 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 214005
14 April 1999 COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1400969
3 April 1999 Deficiency Check · Damage Survey
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1121539
2 April 1999 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 176887
5 February 1999 Administrative
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1127593
1 December 1998 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 811067
11 September 1998 Damage Survey
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 799381
12 June 1998 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 791544
16 April 1998 Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1460180
21 May 1997 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1106869
15 April 1997 Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1442555
16 January 1997 Administrative
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1098601
20 June 1996 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1079640
19 April 1996 COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1404136
22 February 1996 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1079310
1 February 1996 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 872199
13 December 1995 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1189293
8 December 1995 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1186853
2 October 1995 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1438364
13 September 1995 Hull Examination
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1360251
14 August 1995 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1181286
19 April 1995 COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1172185
19 April 1994 COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1167013
30 June 1993 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 841812
24 May 1993 COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1140223
6 April 1993 Administrative
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1148113
5 July 1992 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1265064
29 April 1992 COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 958781
3 April 1992 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 946879
6 September 1991 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 941613
1 August 1991 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 936970
6 May 1991 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 927339
2 May 1991 COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 914906
26 March 1991 Hull Examination
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1236442
6 March 1991 Administrative
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1243304
6 November 1990 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1219647
27 June 1990 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1214303
11 June 1990 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1219733
2 May 1990 COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1214719
26 February 1990 Administrative
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1217051
18 July 1989 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1203064
14 July 1989 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1198257
2 May 1989 COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1351296
4 April 1989 Administrative
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 898125
12 January 1989 Administrative
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 888076
28 October 1988 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1206691
3 May 1988 COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1042856
15 April 1988 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1339000
2 July 1987 Examination of Repairs
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1015064
20 May 1987 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1332110
13 May 1987 Examination of Repairs
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1332352
5 May 1987 COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1325911
3 November 1986 Examination of Repairs
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1013230
5 May 1986 COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1307393
10 March 1986 Damage Survey
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1297740
18 February 1986 Credit Drydock
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 987056
16 October 1985 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1296915
14 May 1985 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1287050

Deficiency record · 250

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 3 April 2026 Resolved
The bilge pipe piercing the collision bulkhead shall be fitted with a screw-down valve located on the forward side of the collision bulkhead and operable from the weather deck. In lieu thereof, a screw-down valve without a reach rod may be fitted to the bilge line on the after side of the collision bulkhead if it is readily accessible under service conditions. The valve/reach rod was not operable. Prove proper operation within 30 days. Any proposed changes to the piping system IAW the cite, will require OCMI approval. 46 CFR 182.25-5(d) (Old T)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 May 2026
Resolved 27 April 2026
Resolution: Verified newly installed valve on bilge line in void #2 immeidiately aft of the collision bulkhead to be leak free by witnessing suction test from fore peak.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 3 April 2026 Resolved
ire hazards to be minimized. The general construction of the vessel must be such as to minimize fire hazards insofar as it is reasonable and practicable. Fuel pipe fitting located in void 3 displayed signs of a slow leak, tighten or replace fitting to ensure proper seal.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 April 2026
Resolved 27 April 2026
Resolution: Verified the section of fuel piping to be leak free.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 3 April 2026 Resolved
Abandon ship and man overboard drills and training shall be logged or otherwise documented for review by the Coast Guard upon request. Safety drills haven't been logged appropriately the past several months.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 April 2026
Resolved 27 April 2026
Resolution: Verified drills were being entered into the vessel's log book.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 27 August 2025 Resolved
Repairs to the hull must not be made without the approval of the cognizant [name withheld] venting for the stern void (#7) has a pin hole; Permanent repair proposal must be submitted for OCMI approval. Permanent repairs to be made no later than 28 February 2026. Vessel authorized to operate with temporary repair measures in place. Condition of temporary repair to be checked weekly during vessel's operational season. Any change in condition of the venting or temporary repair to be immediately reported to the OCMI.
Action required: 705 - Other - as specified
Due 28 February 2026
Resolved 22 January 2026
Resolution: The deficiency has been cleared to the satisfaction of an attending USCG Marine Inspector.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 11 June 2025 Resolved
Repairs or alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without the approval of the cognizant [name withheld] to the HVAC system were not approved prior to making alterations and operating with passengers.
Action required: 60 - Rectify deficiencies prior to movement
Due 11 June 2025
Resolved 11 June 2025
02 - Structural Conditions › N/A - No Subsystem › Stability/strength/loading information and instruments
Issued 11 June 2025 Resolved
Repairs or alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without the approval of the cognizant OCMI.
Action required: 60 - Rectify deficiencies prior to movement
Due 11 June 2025
Resolved 11 June 2025
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 11 June 2025 Resolved
Repairs or alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without the approval of the cognizant [name withheld] to the HVAC system were not approved prior to making alterations and operating with passengers.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 June 2025
Resolved 22 September 2025
Resolution: MSC approved one-line diagam (E2-2502792); installation complies with approved plan.
02 - Structural Conditions › N/A - No Subsystem › Stability/strength/loading information and instruments
Issued 11 June 2025 Resolved
Each vessel must have a stability letter issued by the Coast Guard. As per the vessels stability letter (H2-2301918, dated 24MAY2023), alterations in vessel displacement, VCG, or LCG may invalidate the stability letter. Due to vessel alterations, the total aggregate weight change exceeds 2% of the currently approved lightship displacement and, as outlined in MTN 04-95, necessitates a review of stability criteria by MSC. Vessel authorized to operate with a reduction of 04 passengers allowed to be on the 02 deck which also reduces the maximum passengers allowed on the vessel from 228 to 224.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 June 2025
Resolved 24 September 2025
Resolution: Following a stability test conducted on 08 Sep 2025, MSC issued a new stability letter (H2-2503078) on this date.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 3 March 2025 Resolved
The minimum capacity of the power fire pump shall be 50 gallons per minute at a pressure of not less than 60 pounds per square inch at the pump outlet. The pump outlet shall be fitted with a pressure gage. The fire pump gauge was inoperable.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 5 May 2025
Resolution: The deficiency was cleared to the satisfaction of an attending USCG Marine Inspector.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 3 March 2025 Resolved
Gages to indicate cooling water discharge temperature and lubricating, oil pressure shall be provided for all propulsion engines and located so as to be in view of the operator. Several engineering gauges at the operating station were found inoperable. prove proper operation of all.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 5 May 2025
Resolution: The deficiency was cleared to the satisfaction of an attending USCG Marine Inspector.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 March 2025 Resolved
A voltmeter and an ammeter shall be provided that can be used for measuring voltage and current of each generator that is in operation. Ammeter in engine room was found inoperable.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 5 May 2025
Resolution: The deficiency was cleared to the satisfaction of an attending USCG Marine Inspector.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 13 May 2024 Resolved
A vessel must be operated in such a manner as to afford adequate precaution against hazards that might endanger the vessel and the persons being transported. Significant deterioration in the vessel's fore-peak void has reduced hull plate integrity to the point watertight integrity was breached in two areas. Provide permanent repair proposal for marine inspector approval and make repairs to the satisfaction of the attending marine inspector prior to carrying passengers UNDERWAY. Vessel is authorized to carry passengers moored and NOT underway at the Gateway Arch Riverboat facility. The "dockside" operation shall be in full compliance of the vessel's COI and stability letter at all times while passengers are on board.
Action required: 705 - Other - as specified
Resolved 17 May 2024
Resolution: Verified satisfactory repairs.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 10 May 2024 Resolved
A vessel must be operated in such a manner as to afford adequate precaution against hazards that might endanger the vessel and the persons being transported. Bow's fore-peak/bow void hull plating sustained about a dime sized hole located on starboard side, approximately 7 feet aft of bow stem at about the 4' draft line (approximately 18 inches above the waterline). Provide repair proposal for marine inspector approval and make repairs to the satisfaction of the attending marine inspector prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 May 2024
Resolution: Closed deficiency and issued new deficiency which allowed for dock side operation.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 15 February 2024 Resolved
The owner or managing operator of a vessel shall ensure that the vessel complies with the laws and regulations applicable to the vessel and that the vessel is otherwise satisfactory for the intended service. 1. As per 46 CFR 118.115 vessel must comply with 46 CFR 181.20-5 (46 CFR Old Subchapter T) in that fixed fire suppression system must be installed to the satisfaction of the OCMI. As per the USCG approved Kiddie CO2 systems manual, the CO2 system depend on tightness of the space protected. Engine room ventilation dampers failed to close when exercised.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 February 2024
Resolution: MIs verified proper operation of ventilation closures.
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 15 February 2024 Resolved
The owner or managing operator of a vessel shall ensure that the vessel complies with the laws and regulations applicable to the vessel and that the vessel is otherwise satisfactory for the intended service. As per 46 CFR 118.115 vessel must comply with 46 CFR 176.25-50 (46 CFR Old Subchapter T) in that unsafe conditions must be corrected. A hole in the vessel's 2nd deck leaked water directly into a passenger accommodation space. This deficiency has been extended from prior to carriage of passengers to next drydock, due 28FEB2025. Temporary repairs were verified on 21FEB2024.
Action required: 705 - Other - as specified
Due 21 February 2024
Resolved 5 May 2025
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 15 February 2024 Resolved
The person in command of a documented vessel must have on board that vessel the original Certificate of Documentation (COD) currently in effect for that vessel. Current COD not on board vessel at time of inspection.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 21 February 2024
Resolution: MIs verified presence of new COD on board.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 17 March 2023 Resolved
Fire Protection - vessels contracted for on or after July 1, 1961, which carry more than 150 passengers shall meet the requirements of subpart 72.05 of Subchapter H (Passenger Vessels) of this chapter. Main deck FWD PORT side and 01 deck FWD STBD side have areas of wastage on the doors. Vessel has been authorized to conduct temporary repairs of adding 16 gauge steel sheet coverings on wastage areas meeting the class “A “ bulkhead standard. Vessel is allowed to carry passenger. Vessel shall replace both doors once company receives the new fire doors. A due date of May 12, 2023 is issued.
Action required: 705 - Other - as specified
Due 12 May 2023
Resolved 16 May 2023
Resolution: Cleared to the satisfaction of the attending Coast Guard marine inspector.
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 10 March 2023 Resolved
Navigational lights and public address system must be arranged so that they can be energized from two sources of electricity. Inspection found navigational lights and public address system did not energized on emergence/backup power.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 March 2023
Resolution: Cleared to the satisfaction of the attending Coast Guard marine inspector.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 22 February 2023 Resolved
Fire Protection - vessels contracted for on or after July 1, 1961, which carry more than 150 passengers shall meet the requirements of subpart 72.05 of Subchapter H (Passenger Vessels) of this chapter. Six (06) doors installed in a class A-0 bulkhead where found without latches. Location of these doors are as followings: Main deck FWD STBD side Main deck FWD PORT side 01 deck PORT side 01 deck STBD side 01 deck FWD STBD side 01 deck FWD PORT side Prove to the attending Coast Guard marine inspector that the frame and door at each location meets all construction standards in the regulations. Before purchasing products submit products specifications to the Inspection Office for review.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 March 2023
Resolution: Cleared to the satisfaction of the attending Coast Guard marine inspector.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 1 March 2022 Resolved
Gas fire extinguishing system required to be serviced as per CG approved manual. Inspection found fixed gas fire extinguishing system distribution line caps/plugs that extend at least 2 inches beyond the last orifice have not been removed during the bi-annual blow through process. Prove that caps/plugs have been removed and blow through process has been conducted.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 March 2022
Resolved 25 March 2022
Resolution: Cleared to the satisfaction of the attending Coast Guard marine inspector.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 1 March 2022 Resolved
Vessel authorized to meet regulations applicable on 3/10/1996. IAW 46 CFR 183.01-5 (Old T). Inspection found electrical outlet has exposed wires due to cover being damaged, location is behind bar area on 02 deck. Prove wires are not exposed.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 March 2022
Resolved 18 March 2022
Resolution: Cleared to the satisfaction of the attend Coast Guard marine inspector.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 1 March 2022 Resolved
Bilge high level alarms must be provided. Inspection found two level alarms improperly secured in the bilge. This deficiency was corrected before the conclusion of the inspection.
Action required: 10 - Deficiency Rectified
Resolved 1 March 2022
Resolution: Cleared to the satisfaction of the Coast Guard marine inspector.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 1 March 2022 Resolved
Vessel authorized to meet regulations applicable on 3/10/1996. IAW 46 CFR 183.01-5 (Old T). Inspection found exposed wires located on A/C compressor's junction box due to cover missing. Prove wires are not exposed.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 March 2022
Resolved 18 March 2022
Resolution: Cleared to the satisfaction of the attend Coast Guard marine inspector.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 1 March 2022 Resolved
Vessel to be operated in a safe condition free from fire hazards. Inspection found generator windings were saturated in oil. Prove that generator windings are clear and free of oil.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 March 2022
Resolved 18 March 2022
Resolution: Cleared to the satisfaction of the attend Coast Guard marine inspector.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machines/parts
Issued 1 March 2022 Resolved
Vessel authorized to meet regulations applicable on 3/10/1996. IAW 46 CFR 176.25-32 (Old T). Inspection found pressure vessel's safety valve was due for testing. Crew was unable to test safety valve. Test safety valve in presence of attending inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 March 2022
Resolved 3 March 2022
Resolution: Cleared to the satisfaction of the attending Coast Guard marine inspector.
09 - Working and Living Conditions › 092 - Working Conditions › Gangway, accommodation-ladder
Issued 1 March 2022 Resolved
Inspection found shackle not moused on passenger gangway rigging. Inspect all rigging on gangway and properly secure shackles/rigging. Prove that all rigging is properly secured.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 March 2022
Resolved 25 March 2022
Resolution: Cleared to the satisfaction of the attending Coast Guard marine inspector.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 1 March 2022 Resolved
Each life jacket must be marked with the vessel's name and have retro-reflective tape. Inspection found some life jackets had vessel's name on sticker, which were peeling from the material and retro-reflective tape damaged. Prove that all life jackets are permanently marked and have proper retro-reflective tape .
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 March 2022
Resolved 30 March 2022
Resolution: Retro-reflective tape renewed on PFDs and those PFDs with ineffective stickers properly marked with vessel's name.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 1 March 2022 Resolved
Vessel authorized to meet regulations applicable on 3/10/1996. IAW 46 CFR 176.25-35 (Old T). Inspection found steering system chain located port side aft had a kink in one of the chain's links and drive gear was visibly askew from being perpendicular to the shaft.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 March 2022
Resolved 29 March 2022
Resolution: Two worn pillow block bearings were replaced, which re-aligned gear with chain and chain worked.
01 - Certificates & Documentation › 013 - Documents › Signs, indications
Issued 1 March 2022 Resolved
On a vessel on which the number of passengers permitted on upper decks is limited by stability criteria, as indicated by the vessel's stability letter, the maximum number of passengers allowed on an upper deck must be indicated. Inspection found no signage indicating max number of passengers allowed on upper deck.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 March 2022
Resolved 18 March 2022
Resolution: Cleared to the satisfaction of the attend Coast Guard marine inspector.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 1 March 2022 Resolved
Vessel authorized to meet regulations applicable on 3/10/1996. IAW 46 CFR 181.20-15(d) (Old T). Fixed fire extinguishing - simple instructions for the operation of the systems must be located in a conspicuous place at or near all pull boxes. Inspection found no instructions had pull boxes located in the galley.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 March 2022
Resolved 3 March 2022
Resolution: Cleared to the satisfaction of the attending Coast Guard marine inspector.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for radio personnel
Issued 1 March 2022 Resolved
IAW 46 CFR 80.159 Each ship transporting more than six passengers for hire equipped with a radiotelephone station where the station power does not exceed 250 watts carrier power or 1500 watts peak envelope power, the radio operator must hold a marine radio operator permit or higher class license. Inspection found the master unable to provide radio operator’s permit.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 March 2022
Resolved 6 April 2022
Resolution: Objective evidence submitted showing proper submission of permit application and fees; verified that submission meets FCC requirements for master to operate.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 1 March 2022 Resolved
A means of escape that is not readily apparent to a person from both inside and outside that space must be adequately marked IWA 46 CFR 122.606. Inspection found PORT and STBD doors on the 02 deck are not marked "EXIT".
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 March 2022
Resolved 25 March 2022
Resolution: Cleared to the satisfaction of the attending Coast Guard marine inspector.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 1 March 2022 Resolved
Fire Protection - vessels contracted for on or after July 1, 1961, which carry more than 150 passengers shall meet the requirements of subpart 72.05 of Subchapter H (Passenger Vessels) of this chapter. Six (06) doors installed in a class A-0 bulkhead where found without latches. Location of these doors are as followings: Main deck FWD STBD side Main deck FWD PORT side 01 deck PORT side 01 deck STBD side 01 deck FWD STBD side 01 deck FWD PORT side Prove to the attending Coast Guard marine inspector that the frame and door at each location meets all construction standards in the regulations. Before purchasing products submit products specifications to the Inspection Office for review. Action of 705 is given with a due date of 01DEC2022.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 December 2022
Resolved 22 February 2023
Resolution: Cleared to the satisfaction of the Coast Guard marine inspector.
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 16 June 2021 Resolved
Fuel tank starboard side bulkhead access plate/gasket leaking fuel from fuel tank into adjacent void. Take necessary action to stop leak and remove fuel from void prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 June 2021
Resolution: Locking washers installed on all studs, bolts tightened, fuel removed from void bilge.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 19 April 2021 Resolved
Vessel (Existing T-L) required to meet 46 CFR 182.25-10(Old Subchapter T) minimum bilge pumping capacity of 50 gallons per minute (GMP). During bilge test, evacuation of water from bilge pick using installed electric bilge pump was unsatisfactory from multiple voids. Prove proper operation of a pump capable of meeting bilge (46 CFR 182.25 Old-T) and fire pump requirements (46 CFR 181.10 Old-T) applicable to vessel. Vessel authorized to continue operation with an appropriately sized portable dewatering pump kept on board and ready for immediate use.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 May 2021
Resolved 11 August 2021
Resolution: New electric pump installed. Successful operation as bilge and fire pump witnessed by MI.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 6 April 2021 Resolved
Vessel (Existing T-L) required to meet 46 CFR 182.25-10 minimum bilge pumping capacity of 50 gallons per minute (GMP). During bilge test, evacuation of water from bilge pick was well below required rate. Prove proper operation of bilge system to meet GPM rating from each bilge pump or provide an alternative temporary arrangement for consideration/approval.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 April 2021
02 - Structural Conditions › N/A - No Subsystem › Bulkheads - operational damage
Issued 6 April 2021 Resolved
Vessel required to be operated in a manner as to afford precaution against hazards to the vessel and personnel. Diesel fuel tank access plate located on starboard side of tank leaked fuel into the adjacent void. Repair and prove proper seal of plate gasket and ensure bulkhead in vicinity of plate is sound and leak free.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 April 2021
Resolution: New hatch fitting installed; new gasket installed.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 6 April 2021 Resolved
Vessel required to be equipment with operational navigation lights. Port and starboard running lights were inoperable. Lights bulbs were replaced during inspection.
Action required: 10 - Deficiency Rectified
Resolved 6 April 2021
Resolution: Bulbs were replaced.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 6 April 2021 Resolved
IAW 46 CFR 122.520 & .540 Crew members are required to participate in man overboard drills (every 3 month), fire drills (monthly), and abandon ship drills (monthly), or, immediately before returning to service if vessel is not operating for a greater time period. Following an extended period vessels was not operating, six individuals had crewed the boat between 22 Mar and Apr 05 without participating in drills as per vessel log. Conduct and document required drills prior to using individuals as crew members.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 April 2021
Resolution: Captain of vessel conducted and logged crew training/drills prior to returning to passenger operation.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 6 April 2021 Resolved
Waterlight is required to be attached to ring buoy with lanyard. Lanyard attaching buoy to waterlight was significantly weathered and frayed. Lanyard required to be renewed.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 May 2021
Resolved 22 April 2021
Resolution: Lanyard was replaced.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 6 April 2021 Resolved
Portable light required at entrance of engine room. Portable light was inoperable at time of inspection.
Action required: 10 - Deficiency Rectified
Resolved 6 April 2021
Resolution: Portable light was serviced and functioned properly.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 6 April 2021 Resolved
Vessel required to be operated in a manner as to afford precaution against hazards to the vessel and personnel. Emergency lighting fixture in engine room not properly secured to bulkhead.
Action required: 10 - Deficiency Rectified
Resolved 6 April 2021
Resolution: Light fixture mounting bracket replaced and re-installed.
02 - Structural Conditions › N/A - No Subsystem › Stability/strength/loading information and instruments
Issued 22 January 2021 Resolved
Provide acceptable documentation showing vessel meets 46 CFR Subchapter S stability requirements.
Action required: 705 - Other - as specified
Resolved 9 August 2021
Resolution: New stability letter issued on 09 Aug 2021 by MSC (H2-2102493) following incline experiment conducted on 15 Jun 2021.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 4 March 2020 Resolved
PFDs required to be marked with retro-reflective tape and the vessel's name. Twelve PFDs required retro-reflective tape and one PFD required to be marked with vessel's name.
Action required: 10 - Deficiency Rectified
Due 4 March 2020
Resolved 4 March 2020
Resolution: Retro-reflective tape applied to twelve PFDs and vessel's name put on one PDF.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 4 March 2020 Resolved
Piping to supply water to mechanical fire pump on starboard engine, first union inboard of sea suction valve, leaked during testing of fire pump. Union required to be made leak free.
Action required: 10 - Deficiency Rectified
Due 4 March 2020
Resolved 4 March 2020
Resolution: Fire pump water supply piping union adjacent to sea suction valve tightened securing leak.
02 - Structural Conditions › N/A - No Subsystem › Bulkheads - operational damage
Issued 4 March 2020 Resolved
Mid-body void, fore and aft watertight bulkheads contain alternating fore and aft deflections between vertical stiffeners. Condition occurred over a period of time, however, there is no previous documentation on condition and no current procedure in place to monitor. Current extent of deflections required to be documented to facilitate future monitoring and evaluation.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 March 2020
Resolved 30 March 2020
Resolution: Vessel operator provided written report of current extent of deflection and procedure for monthly monitoring.
02 - Structural Conditions › N/A - No Subsystem › Bulkhead -corrosion
Issued 4 March 2020 Resolved
Aft most transverse bulkhead (superstructure-transom at stern of vessel) found to have defective weld seam. Location of defective weld seam, in bulkhead within exhaust closet, approximately 10 inches above hull plating and adjacent to starboard side of vessel. Defective weld seam required to be re-worked.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 March 2020
Resolved 30 March 2020
Resolution: Vessel operator provided report stating weld seam had been properly re-worked by SCF marine personnel.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 4 March 2020 Resolved
46 CFR 122.315 states that the vessel master is required to determine that the vessel complies with all applicable stability requirements in the vessel's stability letter prior to departure. Vessel master could not provide an adequate procedure when requested. Required vessel operator to provide procedures for master to meet requirement.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 April 2020
Resolved 30 March 2020
Resolution: Vessel operator provided written procedure for vessel master to ensure vessel is in compliance with stability letter prior to each departure.
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 28 February 2020 Resolved
Main deck, deck plating just forward of aft most transverse bulkhead (at stern of vessel) wasted along length of bulkhead, all instances less than 12" forward of transverse bulkhead. Wasted deck plate to be cropped to good metal and renewed by no later than 10FEB2021. In interim, plating to be visually examined for deterioration or change in condition at least once a month and logged in the vessel's bridge log AND changes to condition are to be promptly reported to the Marine Inspectors (USCG Sector UMR).
Action required: 705 - Other - as specified
Due 10 February 2021
Resolved 16 March 2021
Resolution: Wasted deck plate cropped and renewed.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 6 September 2019 Resolved
Crop & renew fractured hull plating in bottom hull plate of stern void between the 4th and 5th longitudinal frame from the port side of vessel and approximately 4 feet forward of the transom. Until permanent repairs are effected the vessel is prohibited from passenger vessel service UNLESS the following measures are in place: - Temporary repair (pressure patch) is in place and effectively secures ingress of water, - One portable de-watering pump is on board vessel, - A crew member checks for water in stern void no more than 30 minutes before & after each passenger cruise, - Hull plating fracture promulgation at fracture is checked (will require removal and re-installation of temporary repair) at least once a week, - Water checks & fracture checks are logged & made available upon request(date/time/person/condition), and - changes in condition of fracture and/or any uncontrollable flooding are immediately reported to the local OCMI. (Sector UMR Command Center phone number is [phone withheld]) At all times the vessel is to be operated within limits of vessel's stability letter (3'3" mean draft with no more than 6" of trim).
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 October 2019
Resolved 21 February 2020
Resolution: Hull plating properly repaired.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 12 February 2019 Resolved
46 CFR 183.10-15 (Old Sub T) as referenced by 46 CFR Subchapter K, Part 120: Place electric insulating matting in front of switch board in engine room.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 22 February 2019
Resolution: Examined non-conductive mat placed in front of switch board.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 12 February 2019 Resolved
Clean oil from ship's service generator (in engine room) in vicinity of air intake and turbo charger.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 22 February 2019
Resolution: Examined air intank and turbo charger and verified items cleaned.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 12 February 2019 Resolved
Replace expired visual distress signals.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 February 2019
Resolution: New distress signals purchased; all well within expiration dates.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 12 February 2019 Resolved
Replace expired items in ship's first aid kit.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 22 February 2019
Resolution: Reviewed purchase receipt and items in first aid kit. Expired items had been replaced with items well within expiration dates.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 12 February 2019 Resolved
46 CFR 181.20-15(d) (Old Subchapter T) Post operating instructions (at local controls) for fixed fire extinguishing installation (in space immediately forward of engine room).
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 22 February 2019
Resolution: Examined local controls for fixed fire extinguishing installation. Operating instructions and line diagram posted.
Engineering › Diesel Engine (propulsion-direct drive) › Seal
Issued 27 February 2018 Resolved
Properly secure oil leak at after cooler (for gear box lube oil) on inboard side of port main diesel engine.
Action required: 705 - Other - as specified
Due 6 March 2018
Resolved 27 March 2018
Resolution: New gasket installed by engine technician. Leak secured.
Engineering › Fuel Oil Service System › Filter
Issued 27 February 2018 Resolved
Fuel oil filter assembly not located in engine room as required by 46 CFR 182.20-40(5).
Action required: 705 - Other - as specified
Due 29 March 2018
Resolved 20 March 2018
Resolution: Verified fuel oil filter assembly re-located into engine room.
Personnel › Certificates/Documents/Licenses › PIC
Issued 27 February 2018 Resolved
Senior Deckhand letter of designation not signed by on duty vessel master. COI allows for licensed mate to be substitued with a Senior Deckhand, so designated in writing. Vessel to in full compliance with COI as per 46 CFR 115.110(c).
Action required: 705 - Other - as specified
Due 27 February 2018
Resolved 27 February 2018
Resolution: Master properly documented status of Senior Deckhand in writing.
Electrical › Electric Supply System (service) › Cable
Issued 19 January 2018 Resolved
Make necessary corrections to the deficiencies identified on page 1 of Enclosure (1) listed under "A. Electrical Deficiencies Observed". See attached documentation.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 27 February 2018
Resolved 27 February 2018
Resolution: Corrections made as directed.
Electrical › Electric Supply System (service) › Cable
Issued 19 January 2018 Resolved
Once item 1) from above is addressed, make necessary corrections to the approved electrical plans (Drawing # 17-2298)for items listed on page 1 & 2 of Enclosure (1) under "B. Electrical Plan Edits". Upon completion, re-submit to the MSC for approval. See attached documentation.
Condition: Invalid
Action required: 705 - Other - as specified
Due 27 February 2018
Resolved 27 February 2018
Resolution: Corrections made to approved electrical planss as required.
Electrical › Electric Generation Source (service) › Power Requirement
Issued 24 February 2017 Resolved
Provide, by means of a PE letter, attestation that all systems identified in 46 CFR 120.310(a) on-board the vessel can be powered from two sources of electricity.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 March 2017
Resolved 3 April 2017
Resolution: Received email with signed PE letter attached.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Quantity of CO2
Issued 21 February 2017 Resolved
Identified a deficit in one of the supply bottles for the vsls fixed CO2 system for the E/R. Ensure that the vsls fixed CO2 bottles weight loss does not exceed 10% of the weight of the charge.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 February 2017
Resolved 24 February 2017
Resolution: Received an upadated report with accurate bottle weights.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 21 February 2017 Resolved
Significant deterioration was observed on the starboard forward and port aft stairwells adjacent to the pilothouse. Effect repairs to the affected stairwells.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 February 2017
Resolved 24 February 2017
Resolution: Wasted steel was cropped and renewed.
Electrical › Electric Generation Source (emergency) › Power Requirement
Issued 16 February 2017 Resolved
Submit and obtain plan approval for all modifications made to the vsl's electrical arrangement.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 15 September 2017
Resolved 14 September 2017
Resolution: Electrical plans submitted to MSC.
Engineering › Bilge Water Management System › Manifold
Issued 2 February 2017 Resolved
Prove proper operation of the bilge system. O/O advised MIs that several manifold valves were not seating properly and required replacement.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 February 2017
Resolved 21 February 2017
Resolution: O/O constructed new manifold system with new valves. Tested suction in all voids; all sat.
Engineering › Fuel Oil Service System › Piping
Issued 2 February 2017 Resolved
Make repairs to fuel leak (return line) in the E/R in the overhead IWO of the stbd generator.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 February 2017
Resolved 21 February 2017
Resolution: Obsolete piping removed and fittings tightened.
Electrical › Electrical Distribution System (service) › Cable
Issued 2 February 2017 Resolved
Provide metal supports for all wiring in the E/R where previous supports were removed for stbd MDE overhaul.
Action required: 705 - Other - as specified
Due 21 February 2017
Resolved 21 February 2017
Resolution: MEtal supports replaced in the E/R.
Stability › Watertight Integrity › Watertight Subdivision Standard
Issued 2 February 2017 Resolved
Provide repair proposal for hole in the collision bulkhead (between peak tank and #1 void). Upon reciept of OCMI approval, effect repairs.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 February 2017
Resolved 7 February 2017
Resolution: Approved repair by means of welding the hole. Verfied repairs by means of emailed photo.
Electrical › Electric Generation Source (emergency) › Power Requirement
Issued 2 February 2017 Resolved
Ensure navigation lights are powered by two independent power sources.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 February 2017
Resolved 21 February 2017
Resolution: Verified lights powered up on battery power.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 2 February 2017 Resolved
Conduct satisfactory man overboard drill in the presence of the attending MI.
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 February 2017
Resolved 21 February 2017
Resolution: MIs witnessed satisfactory MOB drill.
Engineering › Compressed Air System (control) › Valve
Issued 2 February 2017 Resolved
Provide satisfactory proof of testing of the safety relief valve for the vsls installed pressure vessel.
Condition: Invalid
Action required: 705 - Other - as specified
Due 21 February 2017
Resolved 21 February 2017
Resolution: O/O had the safety relief valve bench tested at a local company; all sat.
Engineering › Diesel Engine (propulsion-reduction gear) › Piston Rod
Issued 15 November 2016 Resolved
Make necessary repairs to the starboard MDE.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 November 2016
Resolved 13 December 2016
Resolution: Received tech report from Fabick.
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 16 June 2016 Resolved
Employer did not have record of required Supervisor EAP training. Training reqoured as per 46CFR16.401.
Action required: 705 - Other - as specified
Due 30 July 2016
Resolved 28 July 2016
Resolution: Employer provided records showing required personnel had attended required training.
Engineering › Fuel Oil Storage/Transfer System › Tank
Issued 18 February 2016 Resolved
Bulkhead on starboard side of fuel tank (integral) in bow void has a leak. Prior to operating, submit repair proposal to local OCMI.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 March 2016
Resolution: Permanent repairs completed to integral diesel fuel tank. Starboard bulkhead completely replaced and an insert in the aft bulkhead of the fuel tank. Completed satisfactory air test of all repairs.
Construction/Loadline › Structures › Deck Plating
Issued 18 February 2016 Resolved
Overhead in port bow void (deck plating) has two (2) epoxy patches. Submit repair proposal to local OCMI prior to conducting repairs.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 March 2016
Resolution: Operator will monitor deck area and marine inspectors will inspect during each annual. Permanent repairs deferred to next drydock. See Special Notes.
Construction/Loadline › Hull › Hull Plating
Issued 18 February 2016 Resolved
Stern void compartment, port side, under exhaust piping has a leak. Submit repair proposal to local OMCI for approval, prior conducting repairs.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 February 2016
Resolution: Attended vessel at shipyard. Observed no visible signs of water instrusion. UT shots were taken in way of subject area with no indication of excessive wastage. Area will be checked periodically by vessel personnel and marine inspectors at next annual.
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 18 February 2016 Resolved
Emergency instruction list is not mounted at the operating station. Post proper emergency instructions at operating station, prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 March 2016
Resolution: Emergency instructions were properly mounted at operating station.
Communications › Public Address System › Loudspeaker
Issued 18 February 2016 Resolved
Public address system not working on battery backup power. System is either configured wrong or battery is low on power because system trips offline within seconds of taking the load. Repair or replace battery backup prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 March 2016
Resolution: Attended vessel to confirm battery backup properly working.
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 4 January 2011 Resolved
Repair port engine and port generator exhaust leaks (3) in port stern void.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 March 2011
Resolved 28 February 2011
Electrical › Electrical Distribution System (emergency) › Panelboard
Issued 4 January 2011 Resolved
Cover up hole on fire pump control box in engine room and secure to bulkhead.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 March 2011
Resolved 28 February 2011
Engineering › Pressure Vessel › Pressure Gauge
Issued 4 January 2011 Resolved
Replace 200 psi guage with 250 psi guage to fit pressure vessel rating of 250 psi.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 15 March 2011
Resolved 28 February 2011
Accommodation/Occupational Safety › Potable Water System › General
Issued 4 January 2011 Resolved
Repair pinhole leaks in portable water tank.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 March 2011
Resolved 28 February 2011
Engineering › Fuel Oil Service System › Piping
Issued 4 January 2011 Resolved
Repair fuel line leak in void #3.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 March 2011
Resolved 28 February 2011
Construction/Loadline › Structures › Superstructure
Issued 4 January 2011 Resolved
Make proposal for repairs to superstructure on main deck/repair temp patches.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 March 2011
Resolved 21 February 2011
Construction/Loadline › Structures › Deck Plating
Issued 4 January 2011 Resolved
Make proposal for repairs to starboard void #1 overhead 1 inch by 12 inches waistage prior to carrying passengers.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 28 February 2011
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 4 January 2011 Resolved
Correct signage on 2nd deck forward PFD locker (remove signage for child PFD).
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 15 March 2011
Resolved 28 February 2011
Accommodation/Occupational Safety › Messroom › Location
Issued 4 January 2011 Resolved
Clean soda distribution panel in galley.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 March 2011
Resolved 28 February 2011
Electrical › Lighting (service) › Conductor
Issued 24 February 2010 Resolved
Anchor Mast light is of household construction, must change out to meet NAVRULE Requirement
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 25 March 2010
Resolved 15 February 2011
Resolution: Witnessed prper construction of mast light.
Construction/Loadline › Hull › Girder
Issued 24 February 2010 Resolved
Floor Angle is wasted near Port Shaft Tube
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 March 2010
Resolved 5 March 2010
Resolution: Sistering of approx. 18" of angle approved and installed.
Construction/Loadline › Hull › Girder
Issued 24 February 2010 Resolved
Fractured Weld in #2 Void Bulkhead to Deck Frame Gussett
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 March 2010
Resolved 5 March 2010
Resolution: Inspected repaired weld
Construction/Loadline › Hull › Girder
Issued 24 February 2010 Resolved
Fractured Weld in #3 Void FWD Bulkhead Portside near ladder
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 March 2010
Resolved 5 March 2010
Resolution: Inspected repaired weld
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 24 February 2010 Resolved
18 Adult and 1 Child PFD's are damaged needs to be replaced
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 February 2010
Resolved 25 February 2010
Resolution: destroyed and thrown out in presence of MarineInspectors
Personnel › Certificates/Documents/Licenses › Certificate, CPR Course Completion
Issued 24 February 2010 Resolved
CPR Cards expired for crew, must utilize professional staff (EMT) as an alternative if carrying passengers.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 February 2010
Resolved 5 March 2010
Resolution: Verified that crew members were recertified.
Accommodation/Occupational Safety › Heating › Radiator
Issued 24 February 2010 Resolved
electrical Heater is too close to Diesel Fuel Filters in chiller room, must move away.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 25 March 2010
Resolved 5 March 2010
Resolution: Heater removed and electrical supply was de-energized (secured at breaker) and placed in approved junction box pending relocation within space.
Engineering › Compressed Air System (start air) › Receiver/Bottle
Issued 24 February 2010 Resolved
Air receiver needs Internal Exam.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 March 2010
Resolved 5 March 2010
Resolution: Visually inspected internals of pressure vessel. Some scale noted. No severe pitting noted.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 24 February 2010 Resolved
Electrical Motor needs to be mvoed away from underneath sink. it is a splash hazard.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 25 March 2010
Resolved 5 March 2010
Resolution: Motor is for soda machine carbonation system and has a water source that is attached. Motor is still located under sink but moved of to one side to eliminate potential for splash.
Navigation › Piloting/Steering › Swing Meter
Issued 24 February 2009 Resolved
Prove proper operation of steering rudder indicator in wheelhouse.
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 March 2009
Resolved 27 February 2009
Engineering › Bilge Water Management System › Valve
Issued 9 April 2008 Resolved
Prove proper operation of Peak tank bilge suction system.
Due 16 April 2008
Resolved 29 April 2008
Electrical › Electrical Distribution System (emergency) › Circuit Breaker
Issued 9 April 2008 Resolved
Prove proper operation of vessel's emergency curcuits in the whelhouse (P/A system, Nav lights)
Due 16 April 2008
Resolved 29 April 2008
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 11 April 2007 Resolved
Prove proper operation of all emergency lighting prior to carrying passengers during night operations.
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 April 2007
Resolved 12 April 2007
Documentation › Markings/Placards › Official Number (US)
Issued 13 March 2006 Resolved
Properly affix vessel's official number onto the vessel' hull.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 13 April 2006
Resolved 25 April 2006
Engineering › Bilge Water Management System › Valve
Issued 13 March 2006 Resolved
Properly stencil fwd void remote bilge valve station.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 13 April 2006
Resolved 25 April 2006
Communications › Radio Communications › VHF Radiotelephone
Issued 13 March 2006 Resolved
Update vessel's Emergency Broadcast placard to ensure VHF radio is switched to channel 16.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 13 April 2006
Resolved 25 April 2006
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 13 March 2006 Resolved
Restencil Childrens PFD shelf inside locker on the 2nd Deck.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 April 2006
Resolved 22 March 2006
Resolution: Completed
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 13 March 2006 Resolved
Properly clean and renew reflective tape on seven PFD's. (separated from the good ones)
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 13 April 2006
Resolved 22 March 2006
Resolution: Completed
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 13 March 2006 Resolved
Properly renew missing gasket on the aft void hatch cover.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 March 2006
Resolved 13 March 2006
Fire Fighting › Structural - A Class Divisions › Machinery Spaces
Issued 15 March 2005 Resolved
Properly install A-60 insulation on overhead in engine room.
Due 24 March 2005
Resolved 24 March 2005
Electrical › Electrical Distribution System (service) › Wiring
Issued 15 March 2005 Resolved
Properly secure wires for missing heater in engine compartment.
Due 24 March 2005
Resolved 24 March 2005
Accommodation/Occupational Safety › Ventilation › General
Issued 15 March 2005 Resolved
Properly remove dust from air supply vents in the engine room.
Due 24 March 2005
Resolved 24 March 2005
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 15 March 2005 Resolved
Properly remove rags from bilges in the engine room.
Due 24 March 2005
Resolved 24 March 2005
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 15 March 2005 Resolved
Properly insulate stbd enige exhaust flange.
Due 24 March 2005
Resolved 24 March 2005
Electrical › Electric Supply System (service) › Battery Conductor
Issued 15 March 2005 Resolved
Properly clean connector terminals on the stbd engine starting battery terminals.
Due 24 March 2005
Resolved 24 March 2005
Electrical › Electric Generation Source (service) › Generator Cable
Issued 15 March 2005 Resolved
Properly insulate generator starter wire.
Due 24 March 2005
Resolved 24 March 2005
Electrical › Electric Generation Source (service) › Generator Cable
Issued 15 March 2005 Resolved
Properly secure wire running to the generator starter.
Due 24 March 2005
Resolved 24 March 2005
Electrical › Electric Generation Source (service) › Generator
Issued 15 March 2005 Resolved
Properly replace exhaust lagging on generator and find oil leak.
Due 24 March 2005
Resolved 24 March 2005
Electrical › Lighting (emergency) › Lighting Fixture
Issued 15 March 2005 Resolved
Properly repair emergency lighting on second deck.
Due 24 March 2005
Resolved 24 March 2005
Electrical › Electrical Distribution System (emergency) › Switchboard
Issued 15 March 2005 Resolved
Prove proper operation of vessel's navigation lights, VHF radio, and PA system on emergency system.
Due 24 March 2005
Resolved 25 March 2005
Construction/Loadline › Hull › Side Shell
Issued 15 March 2005 Resolved
Properly repair wasted metal in the number 3 hold vent opening.
Due 24 March 2005
Resolved 24 March 2005
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Instructions
Issued 15 March 2005 Resolved
Properly post diagram for manual release for the fixed CO2 system.
Due 24 March 2005
Resolved 24 March 2005
Electrical › Electric Generation Source (service) › Circuit Breaker
Issued 15 March 2005 Resolved
Properly remove or tag out back up generator circut breaker.
Due 25 March 2005
Resolved 25 March 2005
Personnel › Training › First Aid/CPR
Issued 15 March 2005 Resolved
Provide CPR/First Aid training for 50% of the marine crew.
Due 24 March 2005
Resolved 24 March 2005
Personnel › Training › Familiarization Training
Issued 15 March 2005 Resolved
Properly conduct monthly emergency drills.
Due 24 March 2005
Resolved 24 March 2005
Accommodation/Occupational Safety › Ventilation › General
Issued 15 March 2005 Resolved
Properly clean under air handlers on first deck.
Due 24 March 2005
Resolved 24 March 2005
Electrical › Lighting (service) › Lighting Fixture
Issued 15 March 2005 Resolved
Properly install a protection light globe on second deck outside light.
Due 24 March 2005
Resolved 24 March 2005
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 15 March 2005 Resolved
Properly service fire extinguisher on the second deck port side.
Due 24 March 2005
Resolved 24 March 2005
Electrical › Electrical Distribution System (service) › Wiring
Issued 15 March 2005 Resolved
Properly remove plastic wire ties and replace with metal ties.
Due 24 March 2005
Resolved 24 March 2005
Fire Fighting › Structural - A Class Divisions › Machinery Spaces
Issued 6 December 2004 Resolved
Properly renew insullation in overhead of engine room.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 December 2004
Resolved 10 December 2004
Construction/Loadline › Hull › Hull Plating
Issued 5 October 2004 Resolved
Numerous pitting found throughout the hull. Vessel instructed to clad weld pitted areas.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 10 November 2004
Resolved 9 November 2004
Resolution: [name withheld] crawled entire hull and cleared defincies.
Engineering › Sea-water System (primary cooling) › Sea Chest
Issued 5 October 2004 Resolved
Remove sediment buildup from sea chest valves in are where the gate valves seat.
Action required: 17 - Rectify deficiencies prior to departure
Due 13 November 2004
Resolved 12 November 2004
Resolution: All sediment was removed from both sea chest valve bodies. Visually inspected by [name withheld] and [name withheld].
Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 5 October 2004 Resolved
Cut weap hole in bottom of center main stringer in void two forward of the fuel tank next to bilge suction pipe.
Condition: Design Flaw
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 November 2004
Electrical › Lighting (service) › Lighting Fixture
Issued 5 October 2004 Resolved
Place light guards on light in #2 port void and on lights in engine room.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 November 2004
Engineering › Sea-water System (primary cooling) › Valve
Issued 5 October 2004 Resolved
Replace nut on top of valve stem for generator line in #5 void.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 November 2004
Engineering › Sea-water System (primary cooling) › Sea Chest
Issued 5 October 2004 Resolved
Replace wasted sea strainers to port and stbd sea chests.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 November 2004
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 5 October 2004 Resolved
Clean splattered oil in engine room. Oil creates a slip hazard for crew.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 November 2004
Construction/Loadline › Markings › Draft Marks/Indicating System
Issued 5 October 2004 Resolved
Paint draft marks in contrasting color to hull.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 November 2004
Construction/Loadline › Structures › Superstructure
Issued 5 October 2004 Resolved
Properly repair waisted stbd I-beams supporting wheelhouse.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 November 2004
Engineering › Steering Gear System › Rudder Stock
Issued 5 October 2004 Resolved
Port/Stbd pillar blocks wasted.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 November 2004
Engineering › Shafting/Propeller Arrangements › Stern Tube Lubrication/Sealing
Issued 5 October 2004 Resolved
Inspect shaft packing (stern tube seal) for leaks
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 November 2004
Engineering › Diesel Engine (propulsion-direct drive) › Cylinder
Issued 5 October 2004 Resolved
Conduct satisfactory propulsion engine run-ups in the presence of the marine inspector
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 November 2004
Stability › Watertight Integrity › General
Issued 5 October 2004 Resolved
Conduct sea trials under observation of marine inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 November 2004
Engineering › Steering Gear System › Rudder Angle Indicator
Issued 5 October 2004 Resolved
Properly repair amid ships rudder. Rudder favors port by 4 degrees.
Condition: Unknown
Action required: 705 - Other - as specified
Due 14 December 2004
Resolved 6 December 2004
Deck/Cargo › Holds/Tanks › Independent Tank
Issued 5 October 2004 Resolved
Find and properly repair mistery water leak coming through overhead of engine room and depositing on stbd shaft's deck.
Action required: 705 - Other - as specified
Due 30 December 2004
Resolved 6 December 2004
Deck/Cargo › Holds/Tanks › Independent Tank
Issued 6 April 2004 Resolved
Properly repair peak tank valve reach rod. LEGACY COMPONENT DESC: Valve Reach Rod
Condition: Unknown
Due 6 May 2004
Resolved 12 November 2004
Resolution: Corrected in drydock
Deck/Cargo › Holds/Tanks › Bulkhead
Issued 6 April 2004 Resolved
Properly repair deck and bulkhead between the 4th void and engine room at next hull examination.
Condition: Unknown
Due 12 November 2004
Resolved 12 November 2004
Resolution: Item found to be within specs.
Fire Fighting › Miscellaneous Items
Issued 6 April 2004 Resolved
Renew or repair pilot house fire axe. LEGACY COMPONENT DESC: Fire Axe
Condition: Improper/Lack of Maintenance
Due 6 May 2004
Resolved 7 April 2004
Communications › Alarms/Indicators › Bilge Alarm
Issued 6 April 2004 Resolved
Properly label bilge alarm system in the pilot house.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 April 2004
Communications › Alarms/Indicators › Bilge Alarm
Issued 6 April 2004 Resolved
Repair audible bilge alarm in pilot house.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 April 2004
Construction/Loadline › Structures
Issued 21 April 2003 Resolved
Make permanent repairs or replace forward loading ramp. LEGACY COMPONENT DESC: Loading Ramp
Condition: Improper/Lack of Maintenance
Due 21 May 2003
Resolved 22 May 2003
Resolution: Installed newly fabricated brow.
Engineering › Diesel Engine (auxiliary)
Issued 21 April 2003 Resolved
Properly repair oil leak on #2 SSDG govenor. LEGACY COMPONENT DESC: Governor
Condition: Improper/Lack of Maintenance
Due 21 May 2003
Resolved 22 May 2003
Resolution: several seals were replaced and general maint. conducted.
Accommodation/Occupational Safety › Messroom
Issued 21 April 2003 Resolved
Properly sanitize all food and beverage areas prior to serving food and beverages. LEGACY COMPONENT DESC: Food and Beverage Areas
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 April 2003
Resolved 23 April 2003
Resolution: Food serving and storage areas were properly cleaned and sanitized.
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Block
Issued 11 April 2002 Resolved
Repair fuel oil leak on generator.
Condition: Improper/Lack of Maintenance
Due 11 April 2002
Resolved 12 April 2002
Accommodation/Occupational Safety › Cooking Systems
Issued 11 April 2002 Resolved
Ensure galley is properly cleaned and sanitized.
Condition: Improper/Lack of Maintenance
Due 11 April 2002
Resolved 12 April 2002
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 11 April 2002 Resolved
Ensure CO2 controls are not obstructed.
Condition: Improper/Lack of Maintenance
Due 11 April 2002
Resolved 12 April 2002
Stability › Watertight Integrity
Issued 11 April 2002 Resolved
Ensure locking bar is installed on the deck hatch for # 3 void. LEGACY COMPONENT DESC: deck hatch
Condition: Improper/Lack of Maintenance
Due 11 May 2002
Resolved 4 June 2002
Lifesaving › Lifejacket/PFD (Type I)
Issued 11 April 2002 Resolved
Ensure vessel's name is installed on all child PFD's. LEGACY COMPONENT DESC: Marking
Condition: Improper/Lack of Maintenance
Due 11 May 2002
Resolved 4 June 2002
Engineering › Compressed Air System (control)
Issued 11 April 2002 Resolved
Ensure air receiver relief valve is properly tested and the tank is made available for inspection. LEGACY COMPONENT DESC: Compressor
Condition: Improper/Lack of Maintenance
Due 11 May 2002
Resolved 4 June 2002
Engineering › Bilge Water Management System
Issued 11 April 2002 Resolved
Prove proper operation of the bilge suction in # 2 void. LEGACY COMPONENT DESC: Manifold
Condition: Improper/Lack of Maintenance
Due 11 May 2002
Resolved 4 June 2002
Engineering › Diesel Engine (propulsion/auxiliary-electric)
Issued 11 April 2002 Resolved
Ensure pulley guard is properly installed on the generator. LEGACY COMPONENT DESC: pulley guard
Condition: Improper/Lack of Maintenance
Due 11 May 2002
Resolved 12 April 2002
Accommodation/Occupational Safety › Medical/First Aid
Issued 11 April 2002 Resolved
Ensure first aid kit complies with 46 CFR 121.710 and items are not expired. LEGACY COMPONENT DESC: Medicine Chest
Condition: Improper/Lack of Maintenance
Due 11 May 2002
Resolved 4 June 2002
Electrical
Issued 17 April 2000 Resolved
Replace or repair fwd 1st deck E-light on bow.
Condition: Unknown
Due 17 April 2000
Resolved 17 April 2000
Lifesaving
Issued 17 April 2000 Resolved
Properly label 2nd deck aft stbd life jacket locker (Location of childs life jackets).
Condition: Unknown
Due 17 April 2000
Resolved 17 April 2000
Electrical
Issued 17 April 2000 Resolved
Properly secure dead end wires under console in pilot house.
Condition: Unknown
Due 17 April 2000
Resolved 17 April 2000
Electrical
Issued 17 April 2000 Resolved
Properly secure dead end wire in engine room.
Condition: Unknown
Due 17 April 2000
Resolved 17 April 2000
Construction/Loadline
Issued 12 November 1999 Resolved
Submit repair proposal to make proper repairs to transom area of vessel in homeport vice drydock._x001C_ _x001C_
Condition: Unknown
Due 30 March 2000
Resolved 4 April 2000
Engineering
Issued 12 November 1999 Resolved
On 04NOV99 the following CG-835 requirement was issued: Renew or replace both the vessel's propellers due to fractures._x001C_ On 03MAR00 the CG-835 requirement to repair fractures to propellers had notbeen conducted to the satisfaction of the marine inspector.
Condition: Unknown
Due 30 March 2000
Resolved 4 April 2000
Engineering
Issued 3 April 1999 Resolved
Prove proper operation of propulsion control system prior to the carraige of passengers. Repairs must be conducted in the presence of a marine inspector.
Condition: Unknown
Due 7 April 1999
Resolved 7 April 1999
Construction/Loadline
Issued 1 December 1998 Resolved
NO LATER THAT 31DEC98, PROVIDE USCG WITH GAUGING REPORT OF HULL PLATE IN WAY OF TEMPORARY REPAIR TO HULL PLATE FRACTURE IN LAZARETTE. UNTIL NEXT SCHEDULED DRYDOCK, CAREFULLY CHECK TEMP REPAIR WEEKLY AND MAKE VESSEL AVAILABLE FOR INSPECTION OF TEMP REPAIR AT LEAST EVERY THREE MONTHS.
Condition: Unknown
Due 1 December 1998
Resolved 1 December 1998
Construction/Loadline
Issued 11 September 1998 Resolved
MAKE PERMANENT REPAIRS TO 1/2 INCH CRACK IN LAZARETTE BOTTOM PLATE NO LATERTHAN DATE OF NEXT DRYDOCK, OR 25AUG00. UNTIL PERMANENT REPAIRS ARE MADE, MONITOR TEMPORARY REPAIR AT LEAST ONCE PER DAY. PERMANENT REPAIRS MUST BE MADE IMMEDIATELY SHOULD TEMPORARY REPAIR FAIL (CRACK AND/OR LEAK).
Condition: Unknown
Due 11 September 1998
Resolved 11 September 1998
Engineering
Issued 16 April 1998 Resolved
INSTALL GUARDS OVER SHAFTS IN ENGINE ROOM.
Condition: Unknown
Due 16 April 1998
Resolved 16 April 1998
Electrical
Issued 16 April 1998 Resolved
PROPERLY SECURE WIRES IN SPACE UNDER BRIDGE.
Condition: Unknown
Due 16 April 1998
Resolved 16 April 1998
Electrical
Issued 16 April 1998 Resolved
Update circuit directory cards in galley and on bridge.
Condition: Unknown
Due 16 April 1998
Resolved 16 April 1998
Lifesaving
Issued 16 April 1998 Resolved
ENSURE ALL LIFE JACKET LOCKERS ARE PROPERLY LABLED WITH THE AMOUNT OF PFD'STHAT ARE INSIDE.
Condition: Unknown
Due 16 April 1998
Resolved 16 April 1998
Electrical
Issued 16 April 1998 Resolved
INSTALL COVERS ON LIGHTS WITH GLASS GLOBES.
Condition: Unknown
Due 16 April 1998
Resolved 20 April 1998
Lifesaving
Issued 16 April 1998 Resolved
ENSURE PROPER SERVICE OF REFLECTIVE TAPE ON PFD'S.
Condition: Unknown
Due 16 April 1998
Resolved 16 April 1998
Construction/Loadline
Issued 16 April 1998 Resolved
REPIAR OR REPLACE 02 DECK STBD FWD HAND RAIL.
Condition: Unknown
Due 16 April 1998
Resolved 16 April 1998
Engineering
Issued 15 April 1997 Resolved
repair fuel oil leaks on supply and return piping IWO #4 void
Condition: Unknown
Due 15 April 1997
Resolved 15 April 1997
Navigation
Issued 15 April 1997 Resolved
Replace as original, lower rudder linkage (cross connect linkage connectingone rudder post to the other) which is wasted.
Condition: Unknown
Due 15 April 1997
Resolved 15 April 1997
Electrical
Issued 15 April 1997 Resolved
Replace as original the power supply cord for the electric winch on the rescue platform.
Condition: Unknown
Due 15 April 1997
Resolved 15 April 1997
Electrical
Issued 19 April 1996 Resolved
REPLACE PLASTIC WIRE TIES IN E/R OVERHEAD WITH METAL FASTENERS.
Condition: Unknown
Due 19 April 1996
Resolved 19 April 1996
Lifesaving
Issued 19 April 1996 Resolved
PORT SIDE BRIDGE WING RING BUOY LINE DEGRADED.
Condition: Unknown
Due 19 April 1996
Resolved 19 April 1996
Fire Fighting
Issued 2 October 1995 Resolved
INSTALL FIRE INSULATION IN THE ENGINEROOM OVERHEAD ABOVE THE MAIN DIESEL ENGINES.
Condition: Unknown
Due 2 October 1995
Resolved 2 October 1995
Engineering
Issued 2 October 1995 Resolved
BOTH MDE EXHAUST BLANKETS ON THE EXHAUST SIDE OF THE TURBOCHARGER WERE MISSING.
Condition: Unknown
Due 2 October 1995
Resolved 2 October 1995
Engineering
Issued 2 October 1995 Resolved
REPAIR LEAKS IN PIPE CONNECTION IN THE F/O TRANSFER SYSTEM PIPING, BELOW DECKS IN #3, #4, AND #5 VOIDS.
Condition: Unknown
Due 2 October 1995
Resolved 2 October 1995
Engineering
Issued 13 September 1995 Resolved
gas-free vessel's fuel tank and make ready for internal inspection by a Coast Guard marine inspector.
Condition: Unknown
Due 13 September 1995
Resolved 13 September 1995
Construction/Loadline
Issued 13 September 1995 Resolved
repair/replace rub rail and supporting members around main deck
Condition: Unknown
Due 13 September 1995
Resolved 13 September 1995
Engineering
Issued 19 April 1995 Resolved
ELIMINATE FUEL LEAK AT PIPING UNION IN COMPARTMENT #3.
Condition: Unknown
Due 27 April 1995
Resolved 27 April 1995
Lifesaving
Issued 19 April 1995 Resolved
RENEW WASTED GRAB LINE ON PORT BRIDGE WING LIFE RING BUOY.
Condition: Unknown
Due 19 April 1995
Resolved 19 April 1995
Electrical
Issued 19 April 1995 Resolved
PROVE PROPER OPERATION OF EMERGENCY EXIT LIGHTING AFT 2ND DECK, STARBOARD SIDE.
Condition: Unknown
Due 27 April 1995
Resolved 27 April 1995
Construction/Loadline
Issued 24 May 1993 Resolved
CROP AND RENEW WASTED PLATE FORMING FORWARD MAIN DECK PFD LOCKER.
Condition: Unknown
Due 24 May 1993
Resolved 24 May 1993
Engineering
Issued 24 May 1993 Resolved
ELIMINATE FUEL LEAK AT UNION ON AFT BULKHEAD IN HOLD #4.
Condition: Unknown
Due 24 May 1993
Resolved 24 May 1993
Electrical
Issued 29 April 1992 Resolved
PRIOR TO 15MAY92 INSTALL ELECTRICAL SHORE POWER JUNCTION BOX, EXTERIOR OF MAIN DECK AND AFT OF PORT DOOR. UNTIL JUNCTION BOX IS INSTALLED NO PASSENGER ARE ALLOWED ON BOARD WHEN THE VESSEL IS ON SHORE POWER.
Condition: Unknown
Due 29 April 1992
Resolved 29 April 1992
Unknown
Issued 2 May 1991 Resolved
PROPERLY REPAIR PORT NAVIGATION LIGHT.
Condition: Unknown
Due 2 May 1991
Resolved 2 May 1991
Unknown
Issued 2 May 1991 Resolved
PROVIDE NEW LENSES TO MASTHEAD AND STERN NAVIGATION LIGHTS.
Condition: Unknown
Due 2 May 1991
Resolved 2 May 1991
Electrical
Issued 2 May 1991 Resolved
REPLACE WIRING TO LIGHT IN PORT BOW OVERHEAD.
Condition: Unknown
Due 2 May 1991
Resolved 2 May 1991
Electrical
Issued 2 May 1991 Resolved
REMOVE WIRE NUTS UNDER STEERING CONSOLE.
Condition: Unknown
Due 2 May 1991
Resolved 2 May 1991
Electrical
Issued 2 May 1991 Resolved
SECURE WIRE AND RECEPTACLE TO EMERGENCY LIGHT BATTERY CHARGER.
Condition: Unknown
Due 2 May 1991
Resolved 2 May 1991
Navigation
Issued 2 May 1991 Resolved
PROPERLY ATTACH STARBOARD NAVIGATION LIGHT.
Condition: Unknown
Due 2 May 1991
Resolved 2 May 1991
Electrical
Issued 2 May 1991 Resolved
LABEL GENERATOR SWITCH IN GALLEY AS TO OPERATING GENERATOR.
Condition: Unknown
Due 2 May 1991
Resolved 2 May 1991
Engineering
Issued 2 May 1991 Resolved
LABEL BILGE MANIFOLD VALVES.
Condition: Unknown
Due 2 May 1991
Resolved 2 May 1991
Engineering
Issued 2 May 1991 Resolved
PROVIDE PROPER SUPPORTS FOR BILGE & FUEL LINES.
Condition: Unknown
Due 2 May 1991
Resolved 2 May 1991
Engineering
Issued 2 May 1991 Resolved
SUPPORT HIGH SIDE PIPING TO CHILLER.
Condition: Unknown
Due 2 May 1991
Resolved 2 May 1991
Engineering
Issued 2 May 1991 Resolved
PROVIDE STRAINER & CHECK VALVE IN STERN COMPARTMENT BILGE LINE.
Condition: Unknown
Due 2 May 1991
Resolved 2 May 1991
Documentation
Issued 2 May 1991 Resolved
INSTALL MARPOL V PLACARDS IN GALLEY & BEHIND EACH BAR.
Condition: Unknown
Due 2 May 1991
Resolved 2 May 1991
Electrical
Issued 2 May 1991 Resolved
RELABEL FORWARD GALLEY DISTRIBUTION BOX.
Condition: Unknown
Due 2 May 1991
Resolved 2 May 1991
Accommodation/Occupational Safety
Issued 2 May 1991 Resolved
CLEAN GALLEY.
Condition: Unknown
Due 2 May 1991
Resolved 2 May 1991
Electrical
Issued 2 May 1991 Resolved
PROPERLY SECURE WIRING IN GALLEY (BEHIND DISHWASHER & IN FORWARD OVERHEAD).
Condition: Unknown
Due 2 May 1991
Resolved 2 May 1991
Lifesaving
Issued 2 May 1991 Resolved
PROVIDE PFD DONNING INSTRUCTIONS AT EACH LOCKER.
Condition: Unknown
Due 2 May 1991
Resolved 2 May 1991
Lifesaving
Issued 2 May 1991 Resolved
LABEL EACH LOCKER WITH CORRECT NUMBER OF PFD'S.
Condition: Unknown
Due 2 May 1991
Resolved 2 May 1991
Lifesaving
Issued 2 May 1991 Resolved
CLEAN AND APPLY PROPER RETROREFLECTIVE TAPE TO 302 ADULT AND 31 CHILD PFDS.
Condition: Unknown
Due 2 May 1991
Resolved 2 May 1991
Lifesaving
Issued 2 May 1991 Resolved
PROVIDE 02 ADULT AND 05 CHILD PFDS.
Condition: Unknown
Due 2 May 1991
Resolved 2 May 1991
Electrical
Issued 2 May 1991 Resolved
REPAIR BREATHER TUBE TO AUXILIARY GENERATOR.
Condition: Unknown
Due 2 May 1991
Resolved 2 May 1991
Electrical
Issued 2 May 1991 Resolved
REMOVE DEAD END WIRE IN STARBOARD SIDE OF ENGINE ROOM.
Condition: Unknown
Due 2 May 1991
Resolved 2 May 1991
Engineering
Issued 2 May 1991 Resolved
INSTALL GUARDS ON ALL DAY TANKS. INSTALL SIGHT GLASS IN ONE DAY TANK.
Condition: Unknown
Due 2 May 1991
Resolved 2 May 1991
Electrical
Issued 2 May 1991 Resolved
INSTALL PERMANENT WARNING SIGN ON MAIN GENERATOR PANEL "WARNING. ENSURE SHORE POWER IS DISCONNECTED PRIOR TO PLACING GENERATOR ON LINE".
Condition: Unknown
Due 2 May 1991
Resolved 2 May 1991
Engineering
Issued 2 May 1991 Resolved
INSTALL 30X30 MESH FLAME SCREEN ON FUEL TANK VENT.
Condition: Unknown
Due 2 May 1991
Resolved 2 May 1991
Documentation
Issued 2 May 1991 Resolved
POST STABILITY LETTER.
Condition: Unknown
Due 2 May 1991
Resolved 2 May 1991
Fire Fighting
Issued 2 May 1991 Resolved
REMOVE OR SERVICE 4TH B-II.
Condition: Unknown
Due 2 May 1991
Resolved 2 May 1991
Engineering
Issued 2 May 1991 Resolved
HYDRO TEST AIR RECEIVER, THEN PRESENT FOR INTERNAL INSPECTION.
Condition: Unknown
Due 2 May 1991
Resolved 2 May 1991
Unknown
Issued 2 May 1991 Resolved
LABEL FIRE PUMP BREAKERS IN ENGINE ROOM AND GALLEY.
Condition: Unknown
Due 2 May 1991
Resolved 2 May 1991
Engineering
Issued 2 May 1991 Resolved
BENCH TEST RELIEF VALVE ON AIR RECEIVER & PROVIDE CAPACITY DATA.
Condition: Unknown
Due 2 May 1991
Resolved 2 May 1991
Engineering
Issued 2 May 1991 Resolved
SUPPORT RAW WATER SUCTION SIDE PIPING TO CONDENSER PUMP.
Condition: Unknown
Due 2 May 1991
Resolved 2 May 1991
Electrical
Issued 2 May 1991 Resolved
SECURE ELECTRICAL GAUGE WIRING TO BOTH MAIN DIESEL ENGINES.
Condition: Unknown
Due 2 May 1991
Resolved 2 May 1991
Electrical
Issued 2 May 1991 Resolved
PROVIDE AN EMERGENCY DISCONNECT SWITCH FOR MAIN GENERATOR START BATTERY.
Condition: Unknown
Due 2 May 1991
Resolved 2 May 1991
Electrical
Issued 2 May 1991 Resolved
REMOVE OIL FROM MAIN GENERATOR BATTERY BOX.
Condition: Unknown
Due 2 May 1991
Resolved 2 May 1991
Electrical
Issued 2 May 1991 Resolved
PROVIDE RUBBER MAT IN FRONT OF MAIN DISTRIBUTION PANEL.
Condition: Unknown
Due 2 May 1991
Resolved 2 May 1991
Navigation
Issued 11 June 1990 Resolved
CLEAN UP SPILLED HYDRAULIC OIL ON MAIN DECK BY MSD.
Condition: Unknown
Due 11 June 1990
Resolved 11 June 1990
Electrical
Issued 11 June 1990 Resolved
PROVIDE COVER FOR ELECTRICAL CONNECTIONS FOR LOWER ELECTRIC MOTOR TO LOWER HYDRAULIC PUMP.
Condition: Unknown
Due 11 June 1990
Resolved 11 June 1990
Electrical
Issued 11 June 1990 Resolved
PERMANENTLY MOUNT UPPER ELECTRIC MOTOR FOR MSD HYDRAULIC PUMP.
Condition: Unknown
Due 11 June 1990
Resolved 11 June 1990
Construction/Loadline
Issued 2 May 1990 Resolved
REMOVE UNUSED THROUGH HULL FITTING.
Condition: Unknown
Due 2 May 1990
Resolved 2 May 1990
Documentation
Issued 2 May 1990 Resolved
RENEW FCC (RADIO) LICENSE.
Condition: Unknown
Due 2 May 1990
Resolved 2 May 1990
Fire Fighting
Issued 2 May 1989 Resolved
PROVIDE PRESSURE GAUGE AT ELECTRIC FIRE PUMP DISCHARGE SIDE.
Condition: Unknown
Due 2 May 1989
Resolved 2 May 1989
Lifesaving
Issued 2 May 1989 Resolved
AFT VOID: A. REMOVE OIL FROM STBD AFT CORNER AT SHAFT TUNNEL. B. INSERT SHORE POWER CABLE RETAINER INTO BLKHD. C. PROVIDE GLOBES FOR ALL FIXTURES ON OVERHEAD.
Condition: Unknown
Due 2 May 1989
Resolved 2 May 1989
Fire Fighting
Issued 2 May 1989 Resolved
PROVIDE PORTABLE HAND FIRE PUMP WITH GARDEN HOSE FITTING.
Condition: Unknown
Due 2 May 1989
Resolved 2 May 1989
Electrical
Issued 2 May 1989 Resolved
2ND DECK: PORT FWD CLOSET, PROVIDE ELECTRICAL BOX WIRE MOUNTING CLIP ON BOX
Condition: Unknown
Due 2 May 1989
Resolved 2 May 1989
Electrical
Issued 2 May 1989 Resolved
ENGINEROOM: A. REMOUNT BOX FROM THE NEG BATTERY CABLE TO STARTER ON THE PORT GEN. BATT.B. INSTALL BATTERY CAPS FOR THE ABOVE GEN. BATTERY.
Condition: Unknown
Due 2 May 1989
Resolved 2 May 1989
Electrical
Issued 2 May 1989 Resolved
PILOTHOUSE: A. PROVIDE COMPLETE BUT SIMPLE INSTRUCTIONS FOR FIXED CO2 SYSTEM AT PULL. B. MARK CIRCUIT BREAKERS.
Condition: Unknown
Due 2 May 1989
Resolved 2 May 1989
Lifesaving
Issued 2 May 1989 Resolved
PROVIDE 47 USCG TYPE I ADULT AND 2 USCG TYPE I CHILD SIZE LIFE PRESERVERS. VESSEL RESTRICTED TO 328 ADULT AND 36 CHILD.
Condition: Unknown
Due 2 May 1989
Resolved 2 May 1989
Construction/Loadline
Issued 2 May 1989 Resolved
MAKE THE FOLLOWING REPAIRS TO VOID #2: A. FWD CENTER ON OVERHEAD THE VENT IS WASTED - CROP & RENEW TO GOOD METAL. B. AFT STBD CORNER ON OVERHEAD, HOLES WASTED IN MAIN DECK, CROP TO GOOD METAL.
Condition: Unknown
Due 2 May 1989
Resolved 2 May 1989
Construction/Loadline
Issued 2 May 1989 Resolved
VOID #4 MAKE PROPER THRU HULL FITTING THRU DECK STBD OUTBOARD FROM HEATER/ AC DISCHARGE, DO NOT DISCHARGE INTO VOID.
Condition: Unknown
Due 2 May 1989
Resolved 2 May 1989
Lifesaving
Issued 2 May 1989 Resolved
FREE-UP AND STENCIL ALL LIFE JACKET LOCKERS WITH NUMBER OF CHILD AND ADULT AND SEPARATE CHILD SIZE LIFE JACKETS.
Condition: Unknown
Due 2 May 1989
Resolved 2 May 1989
Engineering
Issued 2 May 1989 Resolved
CLEAN OIL FILM FROM ENGINEROOM BILGE.
Condition: Unknown
Due 2 May 1989
Resolved 2 May 1989
Electrical
Issued 2 May 1989 Resolved
PANTRY: MARK/PROVIDE COMPLETE BUT SIMPLE INSTRUCTIONS FOR CO2 SYSTEM INCLUDE SECURING BLOWER FOR ENGINEROOM FIRST.
Condition: Unknown
Due 2 May 1989
Resolved 2 May 1989
Construction/Loadline
Issued 2 May 1989 Resolved
MAIN DECK EXTERIOR: A. RENEW BOTTOM OF MAIN DECK HOUSE AT THE BOTTOM WHERE WASTED THROUGH THE ENTIRE STBD SIDE.
Condition: Unknown
Due 2 May 1989
Resolved 2 May 1989
Construction/Loadline
Issued 3 May 1988 Resolved
RENEW FIRE PROTECTION INSULATION IN ENGINE ROOM TO A-30 STANDARD NOT LATER THAN 31MAY88.
Condition: Unknown
Due 3 May 1988
Resolved 3 May 1988
Lifesaving
Issued 15 April 1988 Resolved
MODIFY BOW LANDING STAGE SUCH THAT IT IS SUITABLE FOR USE AS A RESCUE PLATFORM NOT LATER THAN 31MAY88.
Condition: Unknown
Due 15 April 1988
Resolved 15 April 1988
Lifesaving
Issued 15 April 1988 Resolved
IF MODIFICATION IS NOT DESIRED, PROVIDE A SUITABLE RESCUE BOAT IN ACCORDANCE WITH 46 CFR 180.10-35. THE RESCUE BOAT MUST PASS A SATISFACTORY DEMONSTRATION.
Condition: Unknown
Due 15 April 1988
Resolved 15 April 1988
Engineering
Issued 5 May 1987 Resolved
REPLACE BILGE STRAINER ON BILGE SUCTION IN #1 COMPARTMENT.
Condition: Unknown
Due 5 May 1987
Resolved 5 May 1987
Fire Fighting
Issued 5 May 1987 Resolved
PROVIDE EVIDENCE OF ANNUAL TESTING OF ALL FIXED AND PORTABLE FIRE EXTINGUISHERS.
Condition: Unknown
Due 5 May 1987
Resolved 5 May 1987
Fire Fighting
Issued 5 May 1987 Resolved
REPLACE FIRE HOSE NOZZLE ON MAIN DECK FIRE STATION.
Condition: Unknown
Due 5 May 1987
Resolved 5 May 1987
Construction/Loadline
Issued 18 February 1986 Resolved
REPAIR OR REPLACE INOPERATIVE BILGE SUCTION VALVE IN FORWARD VOID.
Condition: Unknown
Due 18 February 1986
Resolved 18 February 1986

Casualty record · 2

15 May 2003Routine · role: Involved in a Marine Casualty · activity 1866334
1 April 2014Routine · role: Involved in a Marine Casualty · activity 4827597
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.