TOM SAWYER is a 1966 passenger vessel (inspected). The Coast Guard has recorded 29 inspections since 2016, most recently in April 2026, along with 78 deficiencies, 1 operational control and 2 casualty investigations between 2003 and 2014.

Records from 2003 to 2026. Most recent: inspection, 3 April 2026.

Built
1966
Last inspected
3 April 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Everything above is free. The detail below — the inspection history, the deficiency record, the operational controls, the casualty record and the documentation record — is Professional, $39 a month. Sign in.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 3 April 2026
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDG5963
Flag
UNITED STATES
Maury page id
psix-45369

Documentation record

Registered dimensions (L × B × D)83.1 ft × 27.2 ft × 5.4 ft
Registered tonnagegross 99 / net 67
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderDUBUQUE BOAT & BOILER CO · DUBUQUE, IA, UNITED STATES · built 1966
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portST LOUIS, MO
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 6 September 2025 · expires 30 September 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it99 - Regulatory (Subpart C or D), Gross Ton
67 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
Detail on this page

29 inspections, each with its date, unit and type; 78 deficiencies with the resolution recorded against each; 1 operational control with the dates imposed and removed; 2 casualty investigations, with date and classification; the documentation record: dimensions, tonnage, builder, hailing port, endorsements, dates. The counts in the summary above are the same counts, and they are free.

$39 a month or $299 a year, every vessel page, cancel any time. Founding rate $19.99 a month for life, for the first 200 subscribers. Plans Sign in

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 29

3 April 2026 Annual Inspection · Vessel Attendance · MTSA Verification · Deficiency Check · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 8323203
8 January 2026 Damage Survey · Administrative Inspection · Vessel Attendance · Examination of Repairs · Deficiency Check
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 8291781
25 November 2025 Administrative Inspection · In-Service Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 8273547
11 June 2025 Deficiency Check · Inclining Experiment · Damage Survey · Administrative Inspection · Examination of Repairs
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 8157467
3 March 2025 Administrative Inspection · Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 8083513
13 February 2025 Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 8079236
23 January 2025 Examination of Repairs · Damage Survey · Administrative Inspection · In-Service Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 8064948
15 May 2024 Deficiency Check
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 7913675
10 May 2024 Damage Survey · Examination of Repairs
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7909929
15 February 2024 MTSA Verification · Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7859592
30 May 2023 In-Service Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7700581
19 May 2023 Deficiency Check
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7692200
20 March 2023 Administrative Inspection · Examination of Repairs
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7653919
14 February 2023 Deficiency Check · Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7636509
8 February 2023 Damage Survey
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7635176
4 January 2023 Damage Survey · Examination of Repairs
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7617084
1 March 2022 Deficiency Check · COI Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7384707
16 June 2021 Inclining Experiment · Deficiency Check
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7215318
6 April 2021 Deficiency Check · Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7164892
7 December 2020 Deficiency Check · Examination of Repairs · Damage Survey
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7108109
19 December 2019 Annual Inspection · Internal Structural Exam · Examination of Repairs · Drydock Exam · Deficiency Check · MTSA Verification · Damage Survey
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6877304
6 September 2019 Administrative Inspection · Damage Survey
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6805655
12 February 2019 Deficiency Check · Annual Inspection · MTSA Verification · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6616825
17 January 2018 Deficiency Check · Administrative Inspection · MTSA Verification · Plan Review (Other than "T") · Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6344144
14 September 2017 Administrative Inspection · Deficiency Check
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6269266
2 February 2017 MTSA Verification · Administrative Inspection · Deficiency Check · COI Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6041805
14 November 2016 Administrative Inspection · Deficiency Check · Examination of Repairs
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6041483
3 May 2016 DAPI Audit · Deficiency Check
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 5909410
16 February 2016 Deficiency Check · Administrative Inspection · Annual Inspection · Examination of Repairs · MTSA Verification
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 5815916

Deficiency record · 78

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 3 April 2026 Resolved
The bilge pipe piercing the collision bulkhead shall be fitted with a screw-down valve located on the forward side of the collision bulkhead and operable from the weather deck. In lieu thereof, a screw-down valve without a reach rod may be fitted to the bilge line on the after side of the collision bulkhead if it is readily accessible under service conditions. The valve/reach rod was not operable. Prove proper operation within 30 days. Any proposed changes to the piping system IAW the cite, will require OCMI approval. 46 CFR 182.25-5(d) (Old T)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 May 2026
Resolved 27 April 2026
Resolution: Verified newly installed valve on bilge line in void #2 immeidiately aft of the collision bulkhead to be leak free by witnessing suction test from fore peak.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 3 April 2026 Resolved
ire hazards to be minimized. The general construction of the vessel must be such as to minimize fire hazards insofar as it is reasonable and practicable. Fuel pipe fitting located in void 3 displayed signs of a slow leak, tighten or replace fitting to ensure proper seal.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 April 2026
Resolved 27 April 2026
Resolution: Verified the section of fuel piping to be leak free.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 3 April 2026 Resolved
Abandon ship and man overboard drills and training shall be logged or otherwise documented for review by the Coast Guard upon request. Safety drills haven't been logged appropriately the past several months.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 April 2026
Resolved 27 April 2026
Resolution: Verified drills were being entered into the vessel's log book.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 27 August 2025 Resolved
Repairs to the hull must not be made without the approval of the cognizant [name withheld] venting for the stern void (#7) has a pin hole; Permanent repair proposal must be submitted for OCMI approval. Permanent repairs to be made no later than 28 February 2026. Vessel authorized to operate with temporary repair measures in place. Condition of temporary repair to be checked weekly during vessel's operational season. Any change in condition of the venting or temporary repair to be immediately reported to the OCMI.
Action required: 705 - Other - as specified
Due 28 February 2026
Resolved 22 January 2026
Resolution: The deficiency has been cleared to the satisfaction of an attending USCG Marine Inspector.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 11 June 2025 Resolved
Repairs or alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without the approval of the cognizant [name withheld] to the HVAC system were not approved prior to making alterations and operating with passengers.
Action required: 60 - Rectify deficiencies prior to movement
Due 11 June 2025
Resolved 11 June 2025
02 - Structural Conditions › N/A - No Subsystem › Stability/strength/loading information and instruments
Issued 11 June 2025 Resolved
Repairs or alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without the approval of the cognizant OCMI.
Action required: 60 - Rectify deficiencies prior to movement
Due 11 June 2025
Resolved 11 June 2025
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 11 June 2025 Resolved
Repairs or alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without the approval of the cognizant [name withheld] to the HVAC system were not approved prior to making alterations and operating with passengers.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 June 2025
Resolved 22 September 2025
Resolution: MSC approved one-line diagam (E2-2502792); installation complies with approved plan.
02 - Structural Conditions › N/A - No Subsystem › Stability/strength/loading information and instruments
Issued 11 June 2025 Resolved
Each vessel must have a stability letter issued by the Coast Guard. As per the vessels stability letter (H2-2301918, dated 24MAY2023), alterations in vessel displacement, VCG, or LCG may invalidate the stability letter. Due to vessel alterations, the total aggregate weight change exceeds 2% of the currently approved lightship displacement and, as outlined in MTN 04-95, necessitates a review of stability criteria by MSC. Vessel authorized to operate with a reduction of 04 passengers allowed to be on the 02 deck which also reduces the maximum passengers allowed on the vessel from 228 to 224.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 June 2025
Resolved 24 September 2025
Resolution: Following a stability test conducted on 08 Sep 2025, MSC issued a new stability letter (H2-2503078) on this date.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 3 March 2025 Resolved
The minimum capacity of the power fire pump shall be 50 gallons per minute at a pressure of not less than 60 pounds per square inch at the pump outlet. The pump outlet shall be fitted with a pressure gage. The fire pump gauge was inoperable.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 5 May 2025
Resolution: The deficiency was cleared to the satisfaction of an attending USCG Marine Inspector.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 3 March 2025 Resolved
Gages to indicate cooling water discharge temperature and lubricating, oil pressure shall be provided for all propulsion engines and located so as to be in view of the operator. Several engineering gauges at the operating station were found inoperable. prove proper operation of all.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 5 May 2025
Resolution: The deficiency was cleared to the satisfaction of an attending USCG Marine Inspector.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 March 2025 Resolved
A voltmeter and an ammeter shall be provided that can be used for measuring voltage and current of each generator that is in operation. Ammeter in engine room was found inoperable.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 5 May 2025
Resolution: The deficiency was cleared to the satisfaction of an attending USCG Marine Inspector.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 13 May 2024 Resolved
A vessel must be operated in such a manner as to afford adequate precaution against hazards that might endanger the vessel and the persons being transported. Significant deterioration in the vessel's fore-peak void has reduced hull plate integrity to the point watertight integrity was breached in two areas. Provide permanent repair proposal for marine inspector approval and make repairs to the satisfaction of the attending marine inspector prior to carrying passengers UNDERWAY. Vessel is authorized to carry passengers moored and NOT underway at the Gateway Arch Riverboat facility. The "dockside" operation shall be in full compliance of the vessel's COI and stability letter at all times while passengers are on board.
Action required: 705 - Other - as specified
Resolved 17 May 2024
Resolution: Verified satisfactory repairs.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 10 May 2024 Resolved
A vessel must be operated in such a manner as to afford adequate precaution against hazards that might endanger the vessel and the persons being transported. Bow's fore-peak/bow void hull plating sustained about a dime sized hole located on starboard side, approximately 7 feet aft of bow stem at about the 4' draft line (approximately 18 inches above the waterline). Provide repair proposal for marine inspector approval and make repairs to the satisfaction of the attending marine inspector prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 May 2024
Resolution: Closed deficiency and issued new deficiency which allowed for dock side operation.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 15 February 2024 Resolved
The owner or managing operator of a vessel shall ensure that the vessel complies with the laws and regulations applicable to the vessel and that the vessel is otherwise satisfactory for the intended service. 1. As per 46 CFR 118.115 vessel must comply with 46 CFR 181.20-5 (46 CFR Old Subchapter T) in that fixed fire suppression system must be installed to the satisfaction of the OCMI. As per the USCG approved Kiddie CO2 systems manual, the CO2 system depend on tightness of the space protected. Engine room ventilation dampers failed to close when exercised.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 February 2024
Resolution: MIs verified proper operation of ventilation closures.
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 15 February 2024 Resolved
The owner or managing operator of a vessel shall ensure that the vessel complies with the laws and regulations applicable to the vessel and that the vessel is otherwise satisfactory for the intended service. As per 46 CFR 118.115 vessel must comply with 46 CFR 176.25-50 (46 CFR Old Subchapter T) in that unsafe conditions must be corrected. A hole in the vessel's 2nd deck leaked water directly into a passenger accommodation space. This deficiency has been extended from prior to carriage of passengers to next drydock, due 28FEB2025. Temporary repairs were verified on 21FEB2024.
Action required: 705 - Other - as specified
Due 21 February 2024
Resolved 5 May 2025
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 15 February 2024 Resolved
The person in command of a documented vessel must have on board that vessel the original Certificate of Documentation (COD) currently in effect for that vessel. Current COD not on board vessel at time of inspection.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 21 February 2024
Resolution: MIs verified presence of new COD on board.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 17 March 2023 Resolved
Fire Protection - vessels contracted for on or after July 1, 1961, which carry more than 150 passengers shall meet the requirements of subpart 72.05 of Subchapter H (Passenger Vessels) of this chapter. Main deck FWD PORT side and 01 deck FWD STBD side have areas of wastage on the doors. Vessel has been authorized to conduct temporary repairs of adding 16 gauge steel sheet coverings on wastage areas meeting the class “A “ bulkhead standard. Vessel is allowed to carry passenger. Vessel shall replace both doors once company receives the new fire doors. A due date of May 12, 2023 is issued.
Action required: 705 - Other - as specified
Due 12 May 2023
Resolved 16 May 2023
Resolution: Cleared to the satisfaction of the attending Coast Guard marine inspector.
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 10 March 2023 Resolved
Navigational lights and public address system must be arranged so that they can be energized from two sources of electricity. Inspection found navigational lights and public address system did not energized on emergence/backup power.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 March 2023
Resolution: Cleared to the satisfaction of the attending Coast Guard marine inspector.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 22 February 2023 Resolved
Fire Protection - vessels contracted for on or after July 1, 1961, which carry more than 150 passengers shall meet the requirements of subpart 72.05 of Subchapter H (Passenger Vessels) of this chapter. Six (06) doors installed in a class A-0 bulkhead where found without latches. Location of these doors are as followings: Main deck FWD STBD side Main deck FWD PORT side 01 deck PORT side 01 deck STBD side 01 deck FWD STBD side 01 deck FWD PORT side Prove to the attending Coast Guard marine inspector that the frame and door at each location meets all construction standards in the regulations. Before purchasing products submit products specifications to the Inspection Office for review.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 March 2023
Resolution: Cleared to the satisfaction of the attending Coast Guard marine inspector.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 1 March 2022 Resolved
Gas fire extinguishing system required to be serviced as per CG approved manual. Inspection found fixed gas fire extinguishing system distribution line caps/plugs that extend at least 2 inches beyond the last orifice have not been removed during the bi-annual blow through process. Prove that caps/plugs have been removed and blow through process has been conducted.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 March 2022
Resolved 25 March 2022
Resolution: Cleared to the satisfaction of the attending Coast Guard marine inspector.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 1 March 2022 Resolved
Vessel authorized to meet regulations applicable on 3/10/1996. IAW 46 CFR 183.01-5 (Old T). Inspection found electrical outlet has exposed wires due to cover being damaged, location is behind bar area on 02 deck. Prove wires are not exposed.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 March 2022
Resolved 18 March 2022
Resolution: Cleared to the satisfaction of the attend Coast Guard marine inspector.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 1 March 2022 Resolved
Bilge high level alarms must be provided. Inspection found two level alarms improperly secured in the bilge. This deficiency was corrected before the conclusion of the inspection.
Action required: 10 - Deficiency Rectified
Resolved 1 March 2022
Resolution: Cleared to the satisfaction of the Coast Guard marine inspector.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 1 March 2022 Resolved
Vessel authorized to meet regulations applicable on 3/10/1996. IAW 46 CFR 183.01-5 (Old T). Inspection found exposed wires located on A/C compressor's junction box due to cover missing. Prove wires are not exposed.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 March 2022
Resolved 18 March 2022
Resolution: Cleared to the satisfaction of the attend Coast Guard marine inspector.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 1 March 2022 Resolved
Vessel to be operated in a safe condition free from fire hazards. Inspection found generator windings were saturated in oil. Prove that generator windings are clear and free of oil.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 March 2022
Resolved 18 March 2022
Resolution: Cleared to the satisfaction of the attend Coast Guard marine inspector.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machines/parts
Issued 1 March 2022 Resolved
Vessel authorized to meet regulations applicable on 3/10/1996. IAW 46 CFR 176.25-32 (Old T). Inspection found pressure vessel's safety valve was due for testing. Crew was unable to test safety valve. Test safety valve in presence of attending inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 March 2022
Resolved 3 March 2022
Resolution: Cleared to the satisfaction of the attending Coast Guard marine inspector.
09 - Working and Living Conditions › 092 - Working Conditions › Gangway, accommodation-ladder
Issued 1 March 2022 Resolved
Inspection found shackle not moused on passenger gangway rigging. Inspect all rigging on gangway and properly secure shackles/rigging. Prove that all rigging is properly secured.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 March 2022
Resolved 25 March 2022
Resolution: Cleared to the satisfaction of the attending Coast Guard marine inspector.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 1 March 2022 Resolved
Each life jacket must be marked with the vessel's name and have retro-reflective tape. Inspection found some life jackets had vessel's name on sticker, which were peeling from the material and retro-reflective tape damaged. Prove that all life jackets are permanently marked and have proper retro-reflective tape .
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 March 2022
Resolved 30 March 2022
Resolution: Retro-reflective tape renewed on PFDs and those PFDs with ineffective stickers properly marked with vessel's name.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 1 March 2022 Resolved
Vessel authorized to meet regulations applicable on 3/10/1996. IAW 46 CFR 176.25-35 (Old T). Inspection found steering system chain located port side aft had a kink in one of the chain's links and drive gear was visibly askew from being perpendicular to the shaft.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 March 2022
Resolved 29 March 2022
Resolution: Two worn pillow block bearings were replaced, which re-aligned gear with chain and chain worked.
01 - Certificates & Documentation › 013 - Documents › Signs, indications
Issued 1 March 2022 Resolved
On a vessel on which the number of passengers permitted on upper decks is limited by stability criteria, as indicated by the vessel's stability letter, the maximum number of passengers allowed on an upper deck must be indicated. Inspection found no signage indicating max number of passengers allowed on upper deck.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 March 2022
Resolved 18 March 2022
Resolution: Cleared to the satisfaction of the attend Coast Guard marine inspector.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 1 March 2022 Resolved
Vessel authorized to meet regulations applicable on 3/10/1996. IAW 46 CFR 181.20-15(d) (Old T). Fixed fire extinguishing - simple instructions for the operation of the systems must be located in a conspicuous place at or near all pull boxes. Inspection found no instructions had pull boxes located in the galley.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 March 2022
Resolved 3 March 2022
Resolution: Cleared to the satisfaction of the attending Coast Guard marine inspector.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for radio personnel
Issued 1 March 2022 Resolved
IAW 46 CFR 80.159 Each ship transporting more than six passengers for hire equipped with a radiotelephone station where the station power does not exceed 250 watts carrier power or 1500 watts peak envelope power, the radio operator must hold a marine radio operator permit or higher class license. Inspection found the master unable to provide radio operator’s permit.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 March 2022
Resolved 6 April 2022
Resolution: Objective evidence submitted showing proper submission of permit application and fees; verified that submission meets FCC requirements for master to operate.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 1 March 2022 Resolved
A means of escape that is not readily apparent to a person from both inside and outside that space must be adequately marked IWA 46 CFR 122.606. Inspection found PORT and STBD doors on the 02 deck are not marked "EXIT".
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 March 2022
Resolved 25 March 2022
Resolution: Cleared to the satisfaction of the attending Coast Guard marine inspector.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 1 March 2022 Resolved
Fire Protection - vessels contracted for on or after July 1, 1961, which carry more than 150 passengers shall meet the requirements of subpart 72.05 of Subchapter H (Passenger Vessels) of this chapter. Six (06) doors installed in a class A-0 bulkhead where found without latches. Location of these doors are as followings: Main deck FWD STBD side Main deck FWD PORT side 01 deck PORT side 01 deck STBD side 01 deck FWD STBD side 01 deck FWD PORT side Prove to the attending Coast Guard marine inspector that the frame and door at each location meets all construction standards in the regulations. Before purchasing products submit products specifications to the Inspection Office for review. Action of 705 is given with a due date of 01DEC2022.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 December 2022
Resolved 22 February 2023
Resolution: Cleared to the satisfaction of the Coast Guard marine inspector.
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 16 June 2021 Resolved
Fuel tank starboard side bulkhead access plate/gasket leaking fuel from fuel tank into adjacent void. Take necessary action to stop leak and remove fuel from void prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 June 2021
Resolution: Locking washers installed on all studs, bolts tightened, fuel removed from void bilge.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 19 April 2021 Resolved
Vessel (Existing T-L) required to meet 46 CFR 182.25-10(Old Subchapter T) minimum bilge pumping capacity of 50 gallons per minute (GMP). During bilge test, evacuation of water from bilge pick using installed electric bilge pump was unsatisfactory from multiple voids. Prove proper operation of a pump capable of meeting bilge (46 CFR 182.25 Old-T) and fire pump requirements (46 CFR 181.10 Old-T) applicable to vessel. Vessel authorized to continue operation with an appropriately sized portable dewatering pump kept on board and ready for immediate use.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 May 2021
Resolved 11 August 2021
Resolution: New electric pump installed. Successful operation as bilge and fire pump witnessed by MI.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 6 April 2021 Resolved
Vessel (Existing T-L) required to meet 46 CFR 182.25-10 minimum bilge pumping capacity of 50 gallons per minute (GMP). During bilge test, evacuation of water from bilge pick was well below required rate. Prove proper operation of bilge system to meet GPM rating from each bilge pump or provide an alternative temporary arrangement for consideration/approval.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 April 2021
02 - Structural Conditions › N/A - No Subsystem › Bulkheads - operational damage
Issued 6 April 2021 Resolved
Vessel required to be operated in a manner as to afford precaution against hazards to the vessel and personnel. Diesel fuel tank access plate located on starboard side of tank leaked fuel into the adjacent void. Repair and prove proper seal of plate gasket and ensure bulkhead in vicinity of plate is sound and leak free.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 April 2021
Resolution: New hatch fitting installed; new gasket installed.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 6 April 2021 Resolved
Vessel required to be equipment with operational navigation lights. Port and starboard running lights were inoperable. Lights bulbs were replaced during inspection.
Action required: 10 - Deficiency Rectified
Resolved 6 April 2021
Resolution: Bulbs were replaced.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 6 April 2021 Resolved
IAW 46 CFR 122.520 & .540 Crew members are required to participate in man overboard drills (every 3 month), fire drills (monthly), and abandon ship drills (monthly), or, immediately before returning to service if vessel is not operating for a greater time period. Following an extended period vessels was not operating, six individuals had crewed the boat between 22 Mar and Apr 05 without participating in drills as per vessel log. Conduct and document required drills prior to using individuals as crew members.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 April 2021
Resolution: Captain of vessel conducted and logged crew training/drills prior to returning to passenger operation.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 6 April 2021 Resolved
Waterlight is required to be attached to ring buoy with lanyard. Lanyard attaching buoy to waterlight was significantly weathered and frayed. Lanyard required to be renewed.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 May 2021
Resolved 22 April 2021
Resolution: Lanyard was replaced.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 6 April 2021 Resolved
Portable light required at entrance of engine room. Portable light was inoperable at time of inspection.
Action required: 10 - Deficiency Rectified
Resolved 6 April 2021
Resolution: Portable light was serviced and functioned properly.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 6 April 2021 Resolved
Vessel required to be operated in a manner as to afford precaution against hazards to the vessel and personnel. Emergency lighting fixture in engine room not properly secured to bulkhead.
Action required: 10 - Deficiency Rectified
Resolved 6 April 2021
Resolution: Light fixture mounting bracket replaced and re-installed.
02 - Structural Conditions › N/A - No Subsystem › Stability/strength/loading information and instruments
Issued 22 January 2021 Resolved
Provide acceptable documentation showing vessel meets 46 CFR Subchapter S stability requirements.
Action required: 705 - Other - as specified
Resolved 9 August 2021
Resolution: New stability letter issued on 09 Aug 2021 by MSC (H2-2102493) following incline experiment conducted on 15 Jun 2021.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 4 March 2020 Resolved
PFDs required to be marked with retro-reflective tape and the vessel's name. Twelve PFDs required retro-reflective tape and one PFD required to be marked with vessel's name.
Action required: 10 - Deficiency Rectified
Due 4 March 2020
Resolved 4 March 2020
Resolution: Retro-reflective tape applied to twelve PFDs and vessel's name put on one PDF.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 4 March 2020 Resolved
Piping to supply water to mechanical fire pump on starboard engine, first union inboard of sea suction valve, leaked during testing of fire pump. Union required to be made leak free.
Action required: 10 - Deficiency Rectified
Due 4 March 2020
Resolved 4 March 2020
Resolution: Fire pump water supply piping union adjacent to sea suction valve tightened securing leak.
02 - Structural Conditions › N/A - No Subsystem › Bulkheads - operational damage
Issued 4 March 2020 Resolved
Mid-body void, fore and aft watertight bulkheads contain alternating fore and aft deflections between vertical stiffeners. Condition occurred over a period of time, however, there is no previous documentation on condition and no current procedure in place to monitor. Current extent of deflections required to be documented to facilitate future monitoring and evaluation.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 March 2020
Resolved 30 March 2020
Resolution: Vessel operator provided written report of current extent of deflection and procedure for monthly monitoring.
02 - Structural Conditions › N/A - No Subsystem › Bulkhead -corrosion
Issued 4 March 2020 Resolved
Aft most transverse bulkhead (superstructure-transom at stern of vessel) found to have defective weld seam. Location of defective weld seam, in bulkhead within exhaust closet, approximately 10 inches above hull plating and adjacent to starboard side of vessel. Defective weld seam required to be re-worked.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 March 2020
Resolved 30 March 2020
Resolution: Vessel operator provided report stating weld seam had been properly re-worked by SCF marine personnel.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 4 March 2020 Resolved
46 CFR 122.315 states that the vessel master is required to determine that the vessel complies with all applicable stability requirements in the vessel's stability letter prior to departure. Vessel master could not provide an adequate procedure when requested. Required vessel operator to provide procedures for master to meet requirement.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 April 2020
Resolved 30 March 2020
Resolution: Vessel operator provided written procedure for vessel master to ensure vessel is in compliance with stability letter prior to each departure.
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 28 February 2020 Resolved
Main deck, deck plating just forward of aft most transverse bulkhead (at stern of vessel) wasted along length of bulkhead, all instances less than 12" forward of transverse bulkhead. Wasted deck plate to be cropped to good metal and renewed by no later than 10FEB2021. In interim, plating to be visually examined for deterioration or change in condition at least once a month and logged in the vessel's bridge log AND changes to condition are to be promptly reported to the Marine Inspectors (USCG Sector UMR).
Action required: 705 - Other - as specified
Due 10 February 2021
Resolved 16 March 2021
Resolution: Wasted deck plate cropped and renewed.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 6 September 2019 Resolved
Crop & renew fractured hull plating in bottom hull plate of stern void between the 4th and 5th longitudinal frame from the port side of vessel and approximately 4 feet forward of the transom. Until permanent repairs are effected the vessel is prohibited from passenger vessel service UNLESS the following measures are in place: - Temporary repair (pressure patch) is in place and effectively secures ingress of water, - One portable de-watering pump is on board vessel, - A crew member checks for water in stern void no more than 30 minutes before & after each passenger cruise, - Hull plating fracture promulgation at fracture is checked (will require removal and re-installation of temporary repair) at least once a week, - Water checks & fracture checks are logged & made available upon request(date/time/person/condition), and - changes in condition of fracture and/or any uncontrollable flooding are immediately reported to the local OCMI. (Sector UMR Command Center phone number is [phone withheld]) At all times the vessel is to be operated within limits of vessel's stability letter (3'3" mean draft with no more than 6" of trim).
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 October 2019
Resolved 21 February 2020
Resolution: Hull plating properly repaired.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 12 February 2019 Resolved
46 CFR 183.10-15 (Old Sub T) as referenced by 46 CFR Subchapter K, Part 120: Place electric insulating matting in front of switch board in engine room.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 22 February 2019
Resolution: Examined non-conductive mat placed in front of switch board.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 12 February 2019 Resolved
Clean oil from ship's service generator (in engine room) in vicinity of air intake and turbo charger.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 22 February 2019
Resolution: Examined air intank and turbo charger and verified items cleaned.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 12 February 2019 Resolved
Replace expired visual distress signals.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 February 2019
Resolution: New distress signals purchased; all well within expiration dates.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 12 February 2019 Resolved
Replace expired items in ship's first aid kit.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 22 February 2019
Resolution: Reviewed purchase receipt and items in first aid kit. Expired items had been replaced with items well within expiration dates.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 12 February 2019 Resolved
46 CFR 181.20-15(d) (Old Subchapter T) Post operating instructions (at local controls) for fixed fire extinguishing installation (in space immediately forward of engine room).
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 22 February 2019
Resolution: Examined local controls for fixed fire extinguishing installation. Operating instructions and line diagram posted.
Engineering › Diesel Engine (propulsion-direct drive) › Seal
Issued 27 February 2018 Resolved
Properly secure oil leak at after cooler (for gear box lube oil) on inboard side of port main diesel engine.
Action required: 705 - Other - as specified
Due 6 March 2018
Resolved 27 March 2018
Resolution: New gasket installed by engine technician. Leak secured.
Engineering › Fuel Oil Service System › Filter
Issued 27 February 2018 Resolved
Fuel oil filter assembly not located in engine room as required by 46 CFR 182.20-40(5).
Action required: 705 - Other - as specified
Due 29 March 2018
Resolved 20 March 2018
Resolution: Verified fuel oil filter assembly re-located into engine room.
Personnel › Certificates/Documents/Licenses › PIC
Issued 27 February 2018 Resolved
Senior Deckhand letter of designation not signed by on duty vessel master. COI allows for licensed mate to be substitued with a Senior Deckhand, so designated in writing. Vessel to in full compliance with COI as per 46 CFR 115.110(c).
Action required: 705 - Other - as specified
Due 27 February 2018
Resolved 27 February 2018
Resolution: Master properly documented status of Senior Deckhand in writing.
Electrical › Electric Supply System (service) › Cable
Issued 19 January 2018 Resolved
Make necessary corrections to the deficiencies identified on page 1 of Enclosure (1) listed under "A. Electrical Deficiencies Observed". See attached documentation.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 27 February 2018
Resolved 27 February 2018
Resolution: Corrections made as directed.
Electrical › Electric Supply System (service) › Cable
Issued 19 January 2018 Resolved
Once item 1) from above is addressed, make necessary corrections to the approved electrical plans (Drawing # 17-2298)for items listed on page 1 & 2 of Enclosure (1) under "B. Electrical Plan Edits". Upon completion, re-submit to the MSC for approval. See attached documentation.
Condition: Invalid
Action required: 705 - Other - as specified
Due 27 February 2018
Resolved 27 February 2018
Resolution: Corrections made to approved electrical planss as required.
Electrical › Electric Generation Source (service) › Power Requirement
Issued 24 February 2017 Resolved
Provide, by means of a PE letter, attestation that all systems identified in 46 CFR 120.310(a) on-board the vessel can be powered from two sources of electricity.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 March 2017
Resolved 3 April 2017
Resolution: Received email with signed PE letter attached.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Quantity of CO2
Issued 21 February 2017 Resolved
Identified a deficit in one of the supply bottles for the vsls fixed CO2 system for the E/R. Ensure that the vsls fixed CO2 bottles weight loss does not exceed 10% of the weight of the charge.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 February 2017
Resolved 24 February 2017
Resolution: Received an upadated report with accurate bottle weights.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 21 February 2017 Resolved
Significant deterioration was observed on the starboard forward and port aft stairwells adjacent to the pilothouse. Effect repairs to the affected stairwells.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 February 2017
Resolved 24 February 2017
Resolution: Wasted steel was cropped and renewed.
Electrical › Electric Generation Source (emergency) › Power Requirement
Issued 16 February 2017 Resolved
Submit and obtain plan approval for all modifications made to the vsl's electrical arrangement.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 15 September 2017
Resolved 14 September 2017
Resolution: Electrical plans submitted to MSC.
Engineering › Bilge Water Management System › Manifold
Issued 2 February 2017 Resolved
Prove proper operation of the bilge system. O/O advised MIs that several manifold valves were not seating properly and required replacement.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 February 2017
Resolved 21 February 2017
Resolution: O/O constructed new manifold system with new valves. Tested suction in all voids; all sat.
Engineering › Fuel Oil Service System › Piping
Issued 2 February 2017 Resolved
Make repairs to fuel leak (return line) in the E/R in the overhead IWO of the stbd generator.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 February 2017
Resolved 21 February 2017
Resolution: Obsolete piping removed and fittings tightened.
Electrical › Electrical Distribution System (service) › Cable
Issued 2 February 2017 Resolved
Provide metal supports for all wiring in the E/R where previous supports were removed for stbd MDE overhaul.
Action required: 705 - Other - as specified
Due 21 February 2017
Resolved 21 February 2017
Resolution: MEtal supports replaced in the E/R.
Stability › Watertight Integrity › Watertight Subdivision Standard
Issued 2 February 2017 Resolved
Provide repair proposal for hole in the collision bulkhead (between peak tank and #1 void). Upon reciept of OCMI approval, effect repairs.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 February 2017
Resolved 7 February 2017
Resolution: Approved repair by means of welding the hole. Verfied repairs by means of emailed photo.
Electrical › Electric Generation Source (emergency) › Power Requirement
Issued 2 February 2017 Resolved
Ensure navigation lights are powered by two independent power sources.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 February 2017
Resolved 21 February 2017
Resolution: Verified lights powered up on battery power.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 2 February 2017 Resolved
Conduct satisfactory man overboard drill in the presence of the attending MI.
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 February 2017
Resolved 21 February 2017
Resolution: MIs witnessed satisfactory MOB drill.
Engineering › Compressed Air System (control) › Valve
Issued 2 February 2017 Resolved
Provide satisfactory proof of testing of the safety relief valve for the vsls installed pressure vessel.
Condition: Invalid
Action required: 705 - Other - as specified
Due 21 February 2017
Resolved 21 February 2017
Resolution: O/O had the safety relief valve bench tested at a local company; all sat.
Engineering › Diesel Engine (propulsion-reduction gear) › Piston Rod
Issued 15 November 2016 Resolved
Make necessary repairs to the starboard MDE.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 November 2016
Resolved 13 December 2016
Resolution: Received tech report from Fabick.
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 16 June 2016 Resolved
Employer did not have record of required Supervisor EAP training. Training reqoured as per 46CFR16.401.
Action required: 705 - Other - as specified
Due 30 July 2016
Resolved 28 July 2016
Resolution: Employer provided records showing required personnel had attended required training.
Engineering › Fuel Oil Storage/Transfer System › Tank
Issued 18 February 2016 Resolved
Bulkhead on starboard side of fuel tank (integral) in bow void has a leak. Prior to operating, submit repair proposal to local OCMI.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 March 2016
Resolution: Permanent repairs completed to integral diesel fuel tank. Starboard bulkhead completely replaced and an insert in the aft bulkhead of the fuel tank. Completed satisfactory air test of all repairs.
Construction/Loadline › Structures › Deck Plating
Issued 18 February 2016 Resolved
Overhead in port bow void (deck plating) has two (2) epoxy patches. Submit repair proposal to local OCMI prior to conducting repairs.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 March 2016
Resolution: Operator will monitor deck area and marine inspectors will inspect during each annual. Permanent repairs deferred to next drydock. See Special Notes.
Construction/Loadline › Hull › Hull Plating
Issued 18 February 2016 Resolved
Stern void compartment, port side, under exhaust piping has a leak. Submit repair proposal to local OMCI for approval, prior conducting repairs.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 February 2016
Resolution: Attended vessel at shipyard. Observed no visible signs of water instrusion. UT shots were taken in way of subject area with no indication of excessive wastage. Area will be checked periodically by vessel personnel and marine inspectors at next annual.
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 18 February 2016 Resolved
Emergency instruction list is not mounted at the operating station. Post proper emergency instructions at operating station, prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 March 2016
Resolution: Emergency instructions were properly mounted at operating station.
Communications › Public Address System › Loudspeaker
Issued 18 February 2016 Resolved
Public address system not working on battery backup power. System is either configured wrong or battery is low on power because system trips offline within seconds of taking the load. Repair or replace battery backup prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 March 2016
Resolution: Attended vessel to confirm battery backup properly working.

Casualty record · 2

15 May 2003Routine · role: Involved in a Marine Casualty · activity 1866334
1 April 2014Routine · role: Involved in a Marine Casualty · activity 4827597
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.