MAURY USCG vessel records
← All vessels

PALACE 1

Built
1966
Last inspected
9 September 1995
Documentation
No Operation - PM · NVDC file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 31 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.

Inspection record

Last inspected 9 September 1995
…with no type recorded14
Operational controls None recorded without a removal date
Years with a record 14 calendar years (1981–1995)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

Flag
UNITED STATES
Maury page id
psix-45374

Documentation record

Registered dimensions (L × B × D)278.4 ft × 106.0 ft × 12.0 ft
Registered tonnagegross 17,318 / net 5,927
ITC dimensions (L × B × D)278.4 ft × 106.0 ft × 12.0 ft
ITC tonnagegross 17,318 / net 5,927
BuilderTHE INGALLS IRON WORKS CO · DECATUR AL, UNITED STATES · built 1966
Hull materialSteel
PropulsionUNSPECIFIED
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portBILOXI, MS
Endorsements, as the file codes themcw_un
DocumentationNo Operation - PM · issued 1 February 1995 · expires 28 February 1997
Service, as the file records itTank Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it17318 - Convention (Subpart B), Gross Ton
5927 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 30 inspections, each with its date, unit and type; 25 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 30

9 September 1995 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1189039
15 January 1993 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1136882
9 November 1992 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 826093
30 June 1992 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 665918
12 June 1992 Permit to Proceed
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1256554
29 May 1992 Permit to Proceed
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 943711
27 May 1992 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 68862
23 September 1991 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1309699
11 September 1991 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1245669
27 October 1990 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 470030
5 September 1990 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 929713
24 January 1990 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 900371
23 September 1989 COI Inspection · Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1335153
30 August 1989 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1040040
20 March 1989 Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1205806
24 February 1989 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1045219
18 July 1988 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 512369
1 April 1988 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 527039
24 March 1988 Hull Examination · COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1197370
6 May 1987 Administrative
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1022867
1 April 1987 Hull Examination · COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1332590
28 August 1986 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1007198
7 April 1986 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 308793
28 June 1985 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 979255
23 May 1985 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 983379
15 February 1985 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1287855
2 February 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 971706
18 November 1983 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1278846
16 April 1982 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 964933
13 November 1981 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1272692

Deficiency record · 25

Deck/Cargo
Issued 9 November 1992 Resolved
REMOVE PAINT AND SCALE WASTAGE FROM CARGO PIPING FLANGE NUTS THROUGHOUT PIPING SYSTEM WHERE NUTS AND/OR BOLTS ARE SPALLING AND REPLACE WASTED NUTS/BOLTS AS NECESSARY. REPAIRS AND CLEANED EXISTING FLANGE NUTS/BOLTS ARETO BE MADE AVAILABLE FOR INSPECTION BY USCG INSPECTOR.
Condition: Unknown
Due 9 November 1992
Resolved 9 November 1992
Deck/Cargo
Issued 9 November 1992 Resolved
MAKE P/V VALVES AVAILABLE FOR INSPECTION AND VERIFICATION OF PROPER OPERATION BY USCG INSPECTOR.
Condition: Unknown
Due 9 November 1992
Resolved 9 November 1992
Deck/Cargo
Issued 9 November 1992 Resolved
REPLACE IMPROPER ENGINE HYDRAULIC HOSES WITH PROPER HOSE AND FITTING TYPES PER USCG SPECIFICATIONS. MAKE REPAIRS AVAILABLE FOR INSPECTION BY USCG INSPECTOR.
Condition: Unknown
Due 9 November 1992
Resolved 9 November 1992
Documentation
Issued 11 September 1991 Resolved
PROVIDE PROPER OIL TRANSFER PROCEDURES ON BOARD TANKBARGE PRIOR TO NEXT TRANSFER OF CARGO.
Condition: Unknown
Due 11 September 1991
Resolved 11 September 1991
Deck/Cargo
Issued 11 September 1991 Resolved
CROP AND RENEW CARGO PIPING SUPPORT BRACKET LOCATED IN WAY OF FWD SIDE OF CARGO TANK TOP #4 AT NEXT GAS FREEING.
Condition: Unknown
Due 11 September 1991
Resolved 11 September 1991
Deck/Cargo
Issued 11 September 1991 Resolved
REPLACE OR RENEW ULLAGE/GAUGING COVER ON #3S CARGO TANK.
Condition: Unknown
Due 11 September 1991
Resolved 11 September 1991
Navigation
Issued 11 September 1991 Resolved
REPLACE OR RENEW ELECTRICAL WIRING OF STBD NAVIGATION LIGHT.
Condition: Unknown
Due 11 September 1991
Resolved 11 September 1991
Construction/Loadline
Issued 11 September 1991 Resolved
MAKE STERN VOID AVAILABLE FOR INSPECTION BY A MARINE INSPECTOR PRIOR TO INITIATING REPAIRS REQUIRED IN ITEM NO. 0007 ABOVE.
Condition: Unknown
Due 11 September 1991
Resolved 11 September 1991
Deck/Cargo
Issued 11 September 1991 Resolved
MAKE PERMANENT REPAIRS TO DECK EXTENSION COVER OF OPERATING ROD TO BLOCK VALVE IN AFT SECTION OF #5S CARG TANK, BY CROPPING AND RENEWING COVER AND HAVE REPAIRS INSPECTED BY AND TESTING WITNESSED BY A MARINE INSPECTOR.
Condition: Unknown
Due 11 September 1991
Resolved 11 September 1991
Deck/Cargo
Issued 11 September 1991 Resolved
CONDUCT REQUIRED HYDROSTATIC TEST OF CARGO PIPING IN ACCORDANCE WITH 33 CFR155 AND PROVIDE SATISFACTORY TEST RESULTS TO COGNIZANT OCMI.
Condition: Unknown
Due 11 September 1991
Resolved 11 September 1991
Construction/Loadline
Issued 11 September 1991 Resolved
CROP AND RENEW 18" X 24" MINIMUM SECTION OF STERN HULL PLATE AND MAKE INTERNAL REPAIRS AS DETERMINED BY INTERNAL STRUCTURAL EXAM OF STERN VOID.
Condition: Unknown
Due 11 September 1991
Resolved 11 September 1991
Deck/Cargo
Issued 30 August 1989 Resolved
REPACK ALL REACH RODS.
Condition: Unknown
Due 30 August 1989
Resolved 30 August 1989
Deck/Cargo
Issued 30 August 1989 Resolved
RENEW CARGO PUMP REMOTE SHUTDOWN ON CABLE HOUSING.
Condition: Unknown
Due 30 August 1989
Resolved 30 August 1989
Deck/Cargo
Issued 30 August 1989 Resolved
RENEW WASTED DOG PINS ON ULLAGE HATCHES FOR #1P, 1S, AND 2S.
Condition: Unknown
Due 30 August 1989
Resolved 30 August 1989
Deck/Cargo
Issued 30 August 1989 Resolved
PROVE PROPER OPERATION OF CARGO PUMP ENGINE REMOTE SHUTDOWN.
Condition: Unknown
Due 30 August 1989
Resolved 30 August 1989
Documentation
Issued 30 August 1989 Resolved
PAINT/STENCIL VESSEL'S NAME ON PORT AND STARBOARD BOW.
Condition: Unknown
Due 30 August 1989
Resolved 30 August 1989
Construction/Loadline
Issued 30 August 1989 Resolved
REPAINT NAVIGATION LIGHTS SIDE SCREENS
Condition: Unknown
Due 30 August 1989
Resolved 30 August 1989
Deck/Cargo
Issued 30 August 1989 Resolved
RENEW FLAME SCREENS FOR #3 STARBOARD AFT SOUNDING TUBE AND #4 PORT AFT SOUNDING TUBE.
Condition: Unknown
Due 30 August 1989
Resolved 30 August 1989
Deck/Cargo
Issued 30 August 1989 Resolved
MAKE PERMANENT REPAIRS IN WAY OF TEMPORARY REPAIRS (SOFT PATCHES-RED HAND) TO ABOVE DECK CARGO TRANSFER PIPING AND HYDROSTATICALLY TEST SAME IN THE PRESENCE OF A COAST GUARD MARINE INSPECTOR OR GAS FREE AND REMOVE FROM VESSEL.
Condition: Unknown
Due 30 August 1989
Resolved 30 August 1989
Documentation
Issued 30 August 1989 Resolved
PRIOR TO COMPLYING WITH ITEM #5 ABOVE. MODIFY OIL TRANSFER PROCEEDURES ACCORDINGLY.
Condition: Unknown
Due 30 August 1989
Resolved 30 August 1989
Documentation
Issued 30 August 1989 Resolved
AFTER COMPLYING WITH ITEM #5 ABOVE, MODIFY OIL TRANSFER PROCEEDURES ACCORDINGLY.
Condition: Unknown
Due 30 August 1989
Resolved 30 August 1989
Deck/Cargo
Issued 24 February 1989 Resolved
REPAIR CARGO PUMP ENGINE MUFFLER CAP.
Condition: Unknown
Due 24 February 1989
Resolved 24 February 1989
Deck/Cargo
Issued 24 February 1989 Resolved
DRAIN WATER FROM PORT FORWARD DRIP PAN.
Condition: Unknown
Due 24 February 1989
Resolved 24 February 1989
Deck/Cargo
Issued 24 February 1989 Resolved
REPLACE 3S ULLAGE CAP.
Condition: Unknown
Due 24 February 1989
Resolved 24 February 1989
Construction/Loadline
Issued 24 February 1989 Resolved
FREE UP ALL DOGS ON CARGO HATCH AND ULLAGE OPENINGS AND VOID HATCHES.
Condition: Unknown
Due 24 February 1989
Resolved 24 February 1989

Ownership record