MAURY USCG vessel records Sign in
← All vessels

NEUSE

NEUSE is a 1998 passenger vessel (inspected). The Coast Guard has recorded 143 inspections since 1997, most recently in July 2024, along with 97 deficiencies and 32 casualty investigations between 2003 and 2022.

Records from 1997 to 2024. Most recent: inspection, 18 July 2024.

Built
1998
Last inspected
18 July 2024
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WCY3174
453787
Flag
UNITED STATES
367341890
Maury page id
psix-453787

Inspections, by type

…with no type recorded33
Years with a record 27 calendar years (1997–2024)
The 143 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)167.7 ft × 44.0 ft × 10.5 ft
Registered tonnagegross 380 / net 295
ITC dimensions (L × B × D)167.7 ft × 44.0 ft × 10.5 ft
ITC tonnagegross 423 / net 151
BuilderSTEINER SHIPYARD INC · BAYOU LA BATRE, AL, UNITED STATES · built 1998
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portMANNS HARBOR, NC
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 9 April 2026 · expires 31 May 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it151 - Convention (Subpart B), Net Ton
295 - Regulatory (Subpart C or D), Net Ton
423 - Convention (Subpart B), Gross Ton
380 - Regulatory (Subpart C or D), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WCY3174MMSI 367341890 · active · compulsorily equipped · granted 23 February 2018, expires 22 April 2028
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 143

18 July 2024 Re-Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7960986
25 April 2024 Re-Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7901216
22 January 2024 Administrative Inspection · Internal Structural Exam
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7852414
4 January 2024 COI Inspection · In-Service Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7846253
27 December 2023 Damage Survey · Deficiency Check
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7843369
19 October 2023 Re-Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7810963
13 July 2023 Re-Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7741239
19 April 2023 Deficiency Check · Damage Survey
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7671559
13 April 2023 Re-Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7667697
9 January 2023 Deficiency Check · COI Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7616279
19 October 2022 Re-Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7579565
31 August 2022 In-Service Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7547906
27 July 2022 Re-Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7509756
25 June 2022 Type not recorded
No type recorded · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7488863
25 June 2022 In-Service Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7488974
22 June 2022 In-Service Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7484076
17 June 2022 Damage Survey
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7480278
17 June 2022 Type not recorded
No type recorded · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7488447
21 April 2022 Re-Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7435174
4 April 2022 Deficiency Check · Damage Survey
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7425648
3 March 2022 In-Service Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7405670
19 February 2022 Deficiency Check · Damage Survey
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7398935
19 February 2022 Type not recorded
No type recorded · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7400139
19 January 2022 Deficiency Check · COI Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7376650
1 July 2021 Drydock Exam · Examination of Repairs · Internal Structural Exam
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7239619
20 March 2021 Deficiency Check · In-Service Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7160430
20 March 2021 Type not recorded
No type recorded · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7171990
4 February 2021 MTSA Verification · COI Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7135898
3 February 2021 Damage Survey · Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7135581
3 February 2021 Type not recorded
No type recorded · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7135899
30 October 2020 Re-Inspection · MTSA Verification · Deficiency Check
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7087253
30 September 2020 In-Service Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7068525
30 September 2020 Type not recorded
No type recorded · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7076032
20 August 2020 Deficiency Check · Re-Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7001380
19 July 2020 In-Service Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7014435
10 July 2020 Administrative Inspection
Administrative · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7002581
29 May 2020 Periodic Inspection · MTSA Verification · Deadweight Survey
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6923809
27 February 2020 MTSA Verification · COI Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6888890
18 December 2019 Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 6884336
5 December 2019 Re-Inspection · Administrative Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6867772
18 October 2019 Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 6839421
29 August 2019 Periodic Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6741486
4 July 2019 Type not recorded
No type recorded · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6742103
30 May 2019 Periodic Inspection · MTSA Verification
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6656602
5 May 2019 Type not recorded
No type recorded · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6680656
25 March 2019 Type not recorded
No type recorded · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6649581
25 March 2019 In-Service Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6649626
5 March 2019 COI Inspection · Administrative Inspection · MTSA Verification
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6636374
13 August 2018 Administrative Inspection
Administrative · Navigation Center · Activity 6510961
26 July 2018 Examination of Repairs · Hull Examination
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6491216
27 June 2018 Damage Survey · Administrative Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6458409
9 April 2018 MTSA Verification · COI Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6387813
21 February 2018 Administrative Inspection
Administrative · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6358706
14 February 2018 Re-Inspection · Administrative Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6354905
1 November 2017 Re-Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6298749
15 September 2017 Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 6277810
9 August 2017 Re-Inspection · Deficiency Check
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6234961
8 August 2017 Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 6236184
10 May 2017 COI Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6138728
8 February 2017 Re-Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6084460
30 December 2016 In-Service Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6064891
9 November 2016 Deficiency Check · Re-Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6038041
17 October 2016 Deficiency Check
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6024584
18 August 2016 Re-Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 5955460
10 May 2016 Spot Check · COI Inspection · Deficiency Check · MTSA Verification
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 5867237
14 January 2016 Examination of Repairs · Spot Check · Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 5797178
2 October 2015 Drydock Extension · Internal Structural Exam
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 5734567
30 October 2014 COI Inspection · MTSA Verification
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 5009455
16 October 2014 Examination of Repairs
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 5017551
7 August 2014 Re-Inspection · Deficiency Check · MTSA Verification
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 4946583
16 May 2014 Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 4864241
15 May 2014 Re-Inspection · MTSA Verification
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 4859444
10 March 2014 Deficiency Check · In-Service Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 4815339
9 May 2012 In-Service Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 4277141
9 February 2012 Re-Inspection · Administrative Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 4240902
19 September 2011 In-Service Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 4152536
31 August 2011 Type not recorded
No type recorded · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 4132572
24 January 2011 Construction Oversight
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 3932389
19 October 2010 MTSA Verification · MARPOL Annex I Examination · COI Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 3873084
7 October 2010 Administrative Inspection
Administrative · Marine Safety Unit Wilmington · USCG East District (CGD-E) · Activity 3865458
17 March 2010 Examination of Repairs · Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 3696811
22 January 2010 Drydock Extension
Administrative · Marine Safety Unit Wilmington · USCG East District (CGD-E) · Activity 3719933
7 January 2010 Administrative Inspection
Administrative · Sector North Carolina · USCG East District (CGD-E) · Activity 3660470
5 January 2010 Type not recorded
No type recorded · Marine Safety Unit Wilmington · USCG East District (CGD-E) · Activity 3659463
21 December 2009 Examination of Repairs
Physical examination · Marine Safety Unit Wilmington · USCG East District (CGD-E) · Activity 3656830
3 July 2009 Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 3528850
11 May 2009 COI Inspection · MTSA Verification
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 3472140
12 February 2009 Type not recorded
No type recorded · Marine Safety Unit Wilmington · USCG East District (CGD-E) · Activity 3424561
11 February 2009 Type not recorded
No type recorded · Marine Safety Unit Wilmington · USCG East District (CGD-E) · Activity 3674308
8 February 2009 Type not recorded
No type recorded · Marine Safety Unit Wilmington · USCG East District (CGD-E) · Activity 3424429
2 February 2009 Re-Inspection
Physical examination · Marine Safety Unit Wilmington · USCG East District (CGD-E) · Activity 3404164
31 January 2009 Type not recorded
No type recorded · Marine Safety Unit Wilmington · USCG East District (CGD-E) · Activity 3412181
25 November 2008 Examination of Repairs
Physical examination · Marine Safety Unit Wilmington · USCG East District (CGD-E) · Activity 3369227
22 September 2008 Type not recorded
No type recorded · Marine Safety Unit Wilmington · USCG East District (CGD-E) · Activity 3332182
9 September 2008 Periodic Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 3323479
20 February 2008 COI Inspection · Hull Examination · MTSA Verification · Internal Structural Exam
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 3150643
11 December 2007 Periodic Inspection
Physical examination · Marine Safety Unit Wilmington · USCG East District (CGD-E) · Activity 3114746
13 July 2007 Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 3049646
11 July 2007 Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 2997018
29 March 2007 Damage Survey
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 2897694
28 February 2007 MTSA Verification · COI Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 2880582
7 September 2006 Periodic Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 2772174
3 March 2006 MTSA Verification · COI Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 2594032
12 October 2005 Periodic Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 2513538
30 September 2005 Type not recorded
No type recorded · Marine Safety Unit Wilmington · USCG East District (CGD-E) · Activity 2508291
9 May 2005 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 2363059
4 March 2005 COI Inspection · MTSA Verification
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 2299273
23 February 2005 Administrative Inspection
Administrative · MSO WILMINGTON · USCG East District (CGD-E) · Activity 2297770
8 February 2005 Hull Examination
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 2290051
25 January 2005 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 2280498
15 November 2004 Administrative Inspection
Administrative · MSO WILMINGTON · USCG East District (CGD-E) · Activity 2241266
24 October 2004 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 2228797
1 September 2004 Periodic Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 2184041
10 March 2004 COI Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 2007506
16 December 2003 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 2016346
8 December 2003 Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1961091
10 September 2003 Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1918451
18 March 2003 COI Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1762661
21 January 2003 Hull Examination
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1735095
4 October 2002 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1686824
27 September 2002 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1681218
21 May 2002 Administrative Inspection
Administrative · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1619033
21 March 2002 COI Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1485058
30 August 2001 Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1420575
28 June 2001 Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1465667
15 May 2001 Deficiency Check
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1064965
11 April 2001 Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1433800
27 March 2001 COI Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1441806
11 January 2001 Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1450565
22 September 2000 Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1449377
30 June 2000 Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1403176
5 April 2000 COI Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1439023
10 January 2000 Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1450385
9 October 1999 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 56053
7 October 1999 Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1393253
1 July 1999 Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1406528
8 April 1999 COI Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1413509
30 December 1998 Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1462714
14 October 1998 Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1416774
7 July 1998 Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1128474
30 April 1998 Deficiency Check
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 792277
10 April 1998 Initial Construction-Excluding Oversight · Deadweight Survey · Initial Certification · Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1467574
26 September 1997 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1117529

Deficiency record · 97

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 27 December 2023 Resolved
The installation of all systems of a marine engineering nature, together with the details of design, construction, and installation, shall be in accordance with the requirements of subchapter F (Marine Engineering) of this chapter. NCDOT reported "B" end shaft bearing was slipping and sparking during morning checks. NCDOT must conduct repairs IAW manufacturers specifications ans in-kind equipment. Provide proof of repairs to attending marine inspector. If vessel needs to get underway for repairs, notify the MSD Ft. Macon office for request/approval.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 January 2024
Resolution: MI's witnessed SAT operation of "B" end shaft. MI's also viewed pictures and videos of the repair. All SAT.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 19 April 2023 Resolved
All piping, valves, and fittings shall meet the applicable requirements of subchapter F (Marine Engineering) of this chapter. Vessel master made a report stating during fire drill, crew discovered fire main piping located in the engine room had a pin hole leak. Vessel is currently moored at Cherry Branch. NCDOT must provide repair report stating the correction to the vessel and hydro results of the pipe (1.5 times safe working pressure). Vessel master will notify MSD Fort Macon as conditions change.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 April 2023
Resolution: NAGS HEAD DD DMI witnessed repairs and hydro of fire main pipe. MSD will verify repairs onboard vessel.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 18 January 2023 Resolved
Before the vessel leaves port and at all times during the voyage, each lifesaving appliance must be in working order and ready for immediate use. Retro-reflective tape on forty adult sized life jackets were found wasted. Vessel restricted to 273 passengers.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 February 2023
Resolved 23 February 2023
Resolution: 40 Life jackets renewed and onboard the vessel properly stowed.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 18 January 2023 Resolved
All enclosed spaces within the vessel shall be properly vented or ventilated. Means shall be provided to close off all vents and ventilators. Closure for MSD space not properly working with middle louver fin.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 February 2023
Resolved 9 February 2023
Resolution: Attended vsl and observed proper operation of louver.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 19 October 2022 Resolved
All distribution valves and controls shall be of an approved type. All controls shall be suitably protected. Remote control boxes for E/R and EDG Fixed fire extinguishing systems not properly installed. Safety/security glass not secured with second hold down bracket.
Action required: 705 - Other - as specified
Due 26 October 2022
Resolved 21 October 2022
Resolution: NCDOT installed second bracket on all control boxes. All SAT
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 19 October 2022 Resolved
Doors shall have a latch with a minimum throw of 3-4 inch which can be operated from either side of the door. The limit mechanism on outboard door handle for starboard side EDG space was found broken. Make effective repairs.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 November 2022
Resolved 21 October 2022
Resolution: Latch was welded to the limit mechanism.
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 31 August 2022 Resolved
The emergency power source must meet table 112.05-5(a)....Passenger vessels other than Ocean, Great Lakes, or coastwise and not on an international voyage must have a final emergency power source capable of operating for a minimum of 8 hours or twice the time of run, which ever is less. Vessel's representative reported the emergency generator overheats causing the engine to shutdown approximately 15 minutes into running with a load. Provide a final emergency power source capable of operating for a minimum of 8 hours or twice the time of run, which ever is less.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 September 2022
Resolved 18 January 2023
Resolution: Engine jacket water air cooled radiator was renewed. Conducted operational test; sat.
09 - Working and Living Conditions › 092 - Working Conditions › Ventilation (Working spaces)
Issued 31 August 2022 Resolved
Each machinery space must be ventilated to ensure that, when machinery or boilers are operated at full power in all weather including heavy weather, an adequate supply of air is maintained for the operation of the machinery. Vessel's representative reported that the emergency diesel generator has to operate with the emergency generator space's doors open to prevent the engine from overheating. Troubleshoot and provide adequate ventilation to prevent emergency generator from overheating.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 September 2022
Resolved 18 January 2023
Resolution: Conducted operational test for approx. 30 minutes under load. J/W tempartures were at normal readings on the gauge.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 25 June 2022 Resolved
A survey either general or partial, according to the circumstances, shall be made every time an accident occurs or a defect is discovered which affects the safety of the vessel or the efficacy or completeness of its life-saving appliances, fire-fighting, or other equipment. Master reported the #1 steering system gave alarm during transit and automatically shifted to the #2 steering system. No loss of steering was reported. The vessel moored at Cherry Branch. Electricians conducted verification of the system. A fault code for the "B" end transverse thrust was noted. A calibration of the potentiometer and system was completed. After which, the fault was cleared. The system was tested and found working satisfactory; dockside and post underway trails by the crew.
Action required: 10 - Deficiency Rectified
Resolved 26 June 2022
Resolution: Cleared to the satisfaction of the Coast Guard. See narrative for details AN 7488974
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 22 June 2022 Resolved
A survey either general or partial, according to the circumstances, shall be made every time an accident occurs or a defect is discovered which affects the safety of the vessel or the efficacy or completeness of its life-saving appliances, fire-fighting, or other equipment. Master reported the #1 steering system gave alarm during transit and automatically shifted to the #2 steering system. No loss of steering was reported. The vessel moored at Cherry Branch. Electricians conducted verification of the system. A fault code for the "B" end transverse thrust was noted. A calibration of the potentiometer and system was completed. After which, the fault was cleared. The system was tested and found working satisfactory; dockside and post underway trails by the crew.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 22 June 2022
Resolved 22 June 2022
Resolution: Cleared to the satisfaction of the Coast Guard. See narrative for details AN 7484076
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for rescue boats
Issued 17 June 2022 Resolved
A survey either general or partial, according to the circumstances, shall be made every time an accident occurs or a defect is discovered which affects the safety of the vessel or the efficacy or completeness of its life-saving appliances, fire-fighting, or other equipment. Crew reported during checks of the vessels rescue boat. The rescue boat davit manual winch safety cut out switch (for the handle) was found inoperative, further investigation revealed the switch was corroded. Maintenance replaced the switch in-kind and tested satisfactory. The master provided objective evidence and an attestation reporting satisfactory operation.
Condition: Damaged By Earlier Event
Action required: 10 - Deficiency Rectified
Due 17 June 2022
Resolved 17 June 2022
Resolution: The master provided objective evidence and an attestation reporting satisfactory operation of the equipment.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 4 April 2022 Resolved
A survey shall be made every time an accident occurs or a defect is discovered which affects the safety of the vessel. Master reported hitting loading ramp while mooring up. MI's must conducted survey of vessel IVO contact area, prior to departure.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 April 2022
Resolution: MI's conducted inspection IVO reported contacted area. Photos were taken and uploaded into MISLE. MI's found no structural damage and vessel was cleared to operate.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 3 March 2022 Resolved
The Master shall take all precautions to see that automobiles or other vehicles have their motors turned off when ferry is underway and motors shall not be started until ferry is secured. In addition, vehicles at each end end shall have wheels securely blocked. MI witnessed vehicles not properly blocked and vehicles were started prior to docked.
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Resolved 3 March 2022
Resolution: Prior to next scheduled trip, crew members properly blocked the vehicles at the ends of the ferry. Advised Master to ensure all vehicles motor were turned off while underway.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 19 February 2022 Resolved
Each self propelled vessel must have both main and auxiliary steering gear, except when the main steering gear includes two or more identical power units. Master reported the NR1 power unit had an unknown fault causing it to trip offline and automatically switch to the NR2 power unit. Make permanent repairs to steering system. Provide technician's report of findings and repair. Prove proper operation of steering system to USCG Marine Inspector.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 February 2022
Resolution: Maintenance replaced the "A End" lever. Satisfactory Operational test conducted.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 19 January 2022 Resolved
Fire damper on A end of EDG bulhead (intake) is missing hardware IAW 46CFR72.05-50(b).
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 January 2022
Resolved 19 January 2022
Resolution: Obtained pictures/evidence of installed bolts.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 19 January 2022 Resolved
Excesive trash and debris found in bilges IAW 46CFR71.25-45.
Action required: 10 - Deficiency Rectified
Due 19 January 2022
Resolved 19 January 2022
Resolution: Trash and Debris removed during inspection.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machines/parts
Issued 19 January 2022 Resolved
Deck plates in E.R. not properly installed IAW 46CFR72.40-20.
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 January 2022
Resolved 19 January 2022
Resolution: Recieved pictures/ evidence of proper installation.
09 - Working and Living Conditions › 091 - Living Conditions › Ventilation (Accommodation)
Issued 19 January 2022 Resolved
Women's head exhaust vent screening painted over IAW 46CFR72.15-20(a).
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 February 2022
Resolved 20 January 2022
Resolution: Sand blasted vent screen.
08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 19 January 2022 Resolved
Alarm Panel on Bridge B-end control station has faulty alarm for "E-Gen Overspeed" IAW 46CFR111.12-11.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 January 2022
Resolution: New card and power supply installed, test sat.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 19 January 2022 Resolved
Loose Connections on battery terminal in EDG space IAW 46CFR111.60-17.
Action required: 10 - Deficiency Rectified
Due 19 January 2022
Resolved 19 January 2022
Resolution: Observed proper adjustment.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 19 January 2022 Resolved
Missing bracket on bilge suction throughout vessel IAW 46CFR70.20-1.
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 January 2022
Resolved 19 January 2022
Resolution: Crew provided pictures/evidence of mounting hardware.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 19 January 2022 Resolved
Rescue Boat davit has chafed wire on limit switch IAW 46CFR70.28-1.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 January 2022
Resolved 19 January 2022
Resolution: Crew provided evidence/pictures of repaired wire.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 20 March 2021 Resolved
Master reported a steering fault on "B" end while in route to Cherry Branch, during operations. Determine cause of fault and make proper repairs to the satisfaction of the coast guard. Prior to passengers operations.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 March 2021
Resolved 22 March 2021
Resolution: Completed repairs and satisfactory operational testing during attendance of marine inspector.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 20 March 2021 Resolved
Replace or repair "B" control head (lever) is loose not working properly, to the satisfaction of the coast guard.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 April 2021
Resolved 26 March 2021
Resolution: Received, reviewed, and accepted objective evidence the requirement was satisfactorily rectified.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 22 February 2021 Resolved
First aid kit. Pilothouse and engine room expired meds.
Action required: 10 - Deficiency Rectified
Resolved 22 February 2021
Resolution: The first aid medications are now up to date.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 22 February 2021 Resolved
Main deck engine room watertight door unable to secure. Adjust dogs.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 February 2021
Resolution: The door dogs were adjusted and proved proper operation.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 4 February 2021 Resolved
During testing/operation, the rescue boat died and failed to restart. Prove proper operation to the satisfaction of the attending Marine Inspector
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 February 2021
Resolution: New engine intalled and test ran. IO received video objective evidence,
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 3 February 2021 Resolved
Received report of a throttle/steering failure while carrying passengers. Throubleshoot and report finding to marine inspector (MI) prior to requiring attendance. Once permanent repairs are conducted,test all related systems and contact CG MI for attendance of final operational testing prior to carrying passengers.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 February 2021
Resolution: New A end throttles installed and programed.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 3 February 2021 Resolved
After allision with bulkhead, three frames on the underside of the starboard deck on the A end were buckled and one weld was broken. Make permenant repairs to the satisfaction of the attending Marine Inspector.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 1 April 2021
Resolved 20 October 2021
Resolution: MI verified repairs and NDT at yard.
09 - Working and Living Conditions › 091 - Living Conditions › Sanitary Facilities
Issued 18 November 2020 Resolved
Womens Restroom door is not closing properly
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 November 2020
Resolved 30 November 2020
Resolution: The hinge was replaced and the door is now working.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 18 November 2020 Resolved
Determine "A" end upper navigational light. Electrical issue/not operating properly
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 18 November 2020
Resolution: Navigational light is working properly
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 18 November 2020 Resolved
A and B gauge lines are loose.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 18 November 2020
Resolution: The lines were properly tightened. Corrected on the spot.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 18 November 2020 Resolved
Pilot valve CO2 was loose in the fuel tank void.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 18 November 2020
Resolution: The pilot valve was properly tightened
09 - Working and Living Conditions › 091 - Living Conditions › Access/structure
Issued 18 November 2020 Resolved
Loose gear blocking emergency escape void #2A
Action required: 10 - Deficiency Rectified
Resolved 18 November 2020
Resolution: Loose gear was removed from the emergency escape.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 18 November 2020 Resolved
During testing/Mob rescue boat failed to start. Prove proper operation to the satisfaction of the attending Marine Inspector.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 November 2020
Resolution: The crew was able to properly start and operate the rescue boat.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for rescue boats
Issued 18 November 2020 Resolved
Rescue boat davit failed to retrieve rescue boat after rescue boat was deployed. Prove operation of the davit to the satisfaction of the attending Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 November 2020
Resolution: Limit switch was replaced and the davit was properly tested.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 30 September 2020 Resolved
While mooring No. 1 generator oversped and would not maintain electrical load as designed. Make effective repairs and prove proper operation to the attending Marine Inspector. Vessel is restricted from carrying passengers.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 September 2020
Resolved 30 September 2020
Resolution: Deficiency resolved to the satisfaction of the attending inspector.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 20 August 2020 Resolved
Upper deck A end storage locker missing hardware.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 September 2020
Resolved 20 August 2020
Resolution: The deficiency was resolved to the satisfaction of the attending inspector.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 20 August 2020 Resolved
Broken Fire Ext. mount rescue boat (securing strap).
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 September 2020
Resolved 20 August 2020
Resolution: The deficiency was resolved to the satisfaction of the attending inspector.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 20 August 2020 Resolved
Rescue boat securing straps wasted/worn.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 September 2020
Resolved 1 September 2020
Resolution: Rescue boat securing straps were renewed.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 20 August 2020 Resolved
Engine room WTD will not properly close due to adjustment/ alignment issues. Prove proper operation.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 August 2020
Resolved 20 August 2020
Resolution: The deficiency was resolved to the satisfaction of the attending inspector.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 20 August 2020 Resolved
Crews first aid kit had expired medication.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 September 2020
Resolved 20 August 2020
Resolution: The deficiency was resolved to the satisfaction of the attending inspector.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 20 August 2020 Resolved
All water tight doors in the engineering spaces were witnessed as open and unattended, during inspection this date.
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Due 20 August 2020
Resolved 20 August 2020
Resolution: The deficiency was resolved to the satisfaction of the attending inspector.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 20 August 2020 Resolved
PTSP's were not availible for inspection, because vessel was on the run. A requirement for crew to carry out specific testing procedure for voith units and to provide attestation from captain once witnessed as satisfactory.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 September 2020
Resolved 24 August 2020
Resolution: E-mail provided with logging of PSTP testing and [name withheld].
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 20 August 2020 Resolved
Portable fire extinguishers in pilot house, #02, #03, and #17 had loose hoses, when spot checked this date.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 August 2020
Resolved 20 August 2020
Resolution: The deficiency was resolved to the satisfaction of the attending inspector.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 27 February 2020 Resolved
Change out block tackle on the rescue boat ladder wasted and worn.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 12 March 2020
Resolved 3 April 2020
Resolution: Received, reviewed, and accepted objective evidence from company proving the outstanding item was resolved satisfactory.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Lashing material
Issued 27 February 2020 Resolved
Replace the forward and aft cargo netting which was damaged and worn.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 February 2020
Resolved 3 April 2020
Resolution: Received, reviewed, and accepted objective evidence from company proving the outstanding item was resolved satisfactory.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 27 February 2020 Resolved
Install backflow preventer on the saltwater to fresh water filtration piping.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 12 March 2020
Resolved 3 April 2020
Resolution: Received, reviewed, and accepted objective evidence from company proving the outstanding item was resolved satisfactory.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 5 December 2019 Resolved
The Starboard Engine Room door vent closure does not close properly. Make repairs to the satisfaction of attending MI.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 5 December 2019
Resolution: Photo's received and accepted to adequately clear deficiency.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 29 August 2019 Resolved
Install suitable exhaust lagging IWO MDE exhaust side shell penitrations.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 September 2019
Resolved 5 December 2019
Resolution: Lagging has been installed and is acceptable.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificate for medical first aid
Issued 29 August 2019 Resolved
Provide CPR first aid cards.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 September 2019
Resolved 23 September 2019
Resolution: Received, reviewed, and accepted documentation satisfying the requirement.
02 - Structural Conditions › N/A - No Subsystem › Stability/strength/loading information and instruments
Issued 12 March 2019 Resolved
Vessel has not completed a new deadweight survey as required by MSC letter dated September 13,2018 (serial: H2-1803524) and MSC Technical Note 4-95. The new survey is required due to an aggregate weight change in excess of 2%. According to MSC letter dated February 20,2007 (serial: H2-0700482), M/V NEUSE had receive alterations in 2007 amounting to an aggregate weight change of 1.02%. This previous change along with the voith unit soft patch installations, deck wear plate modifications, and other items completed since 2007 exceeds the 2% threshold. Provide new calculations.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 April 2019
Resolved 10 July 2020
Resolution: MSC issued new stability letter P012543 Serial H2-2002388.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 13 August 2018 Resolved
The vessel is currently Not broadcasting (1) IMO number.
Condition: Invalid
Action required: 705 - Other - as specified
Due 13 September 2018
Resolved 5 March 2019
Resolution: Vessel was properly broadcasting Official Number and MMSI number.
Fire Fighting › Ventilation Systems › Ducts
Issued 2 May 2018 Resolved
EDG space vent closures broken spring and will not close 100%.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 May 2018
Resolved 4 May 2018
Resolution: Replaced spring and greased.
Stability › Watertight Integrity › Weathertight Enclosure
Issued 2 May 2018 Resolved
B-end escape hatch dog cracked. Yard period in June conduct repairs.
Action required: 705 - Other - as specified
Due 30 June 2018
Resolved 5 March 2019
Resolution: Completed repairs during credit dry dock.
Stability › Watertight Integrity › Weathertight Enclosure
Issued 2 May 2018 Resolved
A-end escape hatch leaking
Action required: 705 - Other - as specified
Due 9 May 2018
Resolved 4 May 2018
Resolution: Replaced gsk and tested all SAT.
Lifesaving › Rigid Liferafts › Weak Link
Issued 2 May 2018 Resolved
Liferaft straps deteriorated on three rafts.
Action required: 705 - Other - as specified
Due 9 May 2018
Resolved 4 May 2018
Resolution: Replaced all 5 straps on life rafts.
Fire Fighting › Portable CO2 Fire Extinguisher › Condition
Issued 2 May 2018 Resolved
Ext #9 wasted horn clip
Action required: 705 - Other - as specified
Due 1 June 2018
Resolved 4 May 2018
Resolution: Replaced wasted clip.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 2 May 2018 Resolved
Harndrail B-end 01 deck stanchion cracked. Repair in Jane 2018 Yard
Action required: 705 - Other - as specified
Due 30 June 2018
Resolved 5 March 2019
Resolution: Completed repairs during credit dry dock.
Lifesaving › Rescue Boat Equipment › Rescue Quoit
Issued 2 May 2018 Resolved
Quoit ring deteriorated
Action required: 705 - Other - as specified
Due 1 June 2018
Resolved 4 May 2018
Resolution: Replaced Quoit
Engineering › Fuel Oil Storage/Transfer System › Valve
Issued 2 May 2018 Resolved
Fuel remote shutoff link-age temp repaired. replace in yard Jun 2018
Action required: 705 - Other - as specified
Due 30 June 2018
Resolved 5 March 2019
Resolution: Completed repairs during credit dry dock.
Communications › Alarms/Indicators › Engine RPM Gauge/Indicator
Issued 1 November 2017 Resolved
The #2 SSDG RPM gauge in not working; make the necessary repair and prove proper operation.
Due 15 November 2017
Resolved 7 November 2017
Resolution: Conducted operational test of equipment. All sat.
Communications › Alarms/Indicators › Lube Oil Low Pressure Alarm
Issued 9 August 2017 Resolved
#1 SSDG low L/O shutdown did not secure the engine; make repairs and prove proper operation.
Due 23 August 2017
Resolved 21 August 2017
Lifesaving › Lifebuoys › Serviceable
Issued 9 August 2017 Resolved
The life buoy on the "B" end is failing at the inner seam; replace the life buoy and ensure it is properly marked.
Due 23 August 2017
Resolved 21 August 2017
Electrical › Electrical Distribution System (service) › Wiring
Issued 9 August 2017 Resolved
Properly terminate the dead end wires in the #2 SSDG control panel and the EDG control panel.
Due 23 August 2017
Resolved 21 August 2017
Fire Fighting › Ventilation Systems › Ventilation Fire Dampers
Issued 9 August 2017 Resolved
Ventilation closure IWO the emergency generator compartment is not closing as designed; repair as necessary and prove proper operation.
Due 23 August 2017
Resolved 21 August 2017
Electrical › Electrical Distribution System (service) › Junction Box
Issued 9 November 2016 Resolved
Provide a cover for the junction box under the "A" end console on the bridge.
Action required: 705 - Other - as specified
Due 30 November 2016
Resolved 1 December 2016
Communications › Alarms/Indicators › Lube Oil Low Pressure Alarm
Issued 9 November 2016 Resolved
The loss of lube oil pressure shut down for the "A" end main engine did not function as designed, make the necessary repairs.
Action required: 705 - Other - as specified
Due 30 November 2016
Resolved 1 December 2016
Electrical › Electrical Distribution System (service) › Distribution Panel Bus
Issued 9 November 2016 Resolved
The breaker panel index card in the storage room located within the passenger accommodation space is not properly labeled with amperages; make the necessary corrections.
Action required: 705 - Other - as specified
Due 30 November 2016
Resolved 1 December 2016
Engineering › Fuel Oil Service System › Hose
Issued 9 November 2016 Resolved
Provide approved type hose (SAE J-1942) for the following machinery; (1) on the emergency generator, (1)on the "A" end main engine, (1) on the "B" end main engine, and (3)on the "B" end generator.
Action required: 705 - Other - as specified
Due 30 November 2016
Resolved 1 December 2016
Electrical › Electrical Distribution System (emergency) › Distribution Panel Bus
Issued 30 October 2014 Resolved
Verify that all required equipment on the E-bus panel in the pilothouse are operating as required or properly labeled as needed.
Action required: 705 - Other - as specified
Due 15 November 2014
Resolved 13 November 2014
Resolution: Emergency bus panel in the pilothouse has been correctly labeled.
Engineering › Diesel Engine (propulsion-reduction gear) › Emergency shutdown
Issued 7 August 2014 Resolved
During exam we were unable to see either main diesel engines shut down during low lube oil test as required. They only gave a visual/audible alarm. Vessel is to come into compliance and demonstrate proof of low lube oil audible/visual alarm and shutdown for both main diesel engines in the presence of a Coast Guard Marine Inspector along with meeting the requirements of 46 CFR 58.05-10.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 December 2014
Resolved 13 May 2016
Resolution: Low lube oil shutdowns on both MDE's functioning properly as required.
Fire Fighting › Ventilation Systems › Operating Controls
Issued 7 August 2014 Resolved
Louvers to EDG need to operate properly while EDG is running and shutdown to include closing properly. Until cleared Chief engineer to log in engineer's log anytime EDG runs that both louvers are closed and verified closed after EDG is shutdown.
Action required: 705 - Other - as specified
Due 14 August 2014
Resolved 14 August 2014
Resolution: Vessel demonstrated proper operation of EDG louvers as required.
Electrical › Electrical Distribution System (service) › Wiring
Issued 15 May 2014 Resolved
Properly terminate dead end wires under bridge steering consoles
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 15 June 2014
Resolved 7 August 2014
Resolution: Dead end wires appear to be properly terminated as required.
Engineering › Non-conventional Propulsion/Steering › Base (cycloidal)
Issued 10 March 2014 Resolved
Have technician troubleshoot steering control transfer system
Action required: 705 - Other - as specified
Due 24 March 2014
Resolved 13 March 2014
Engineering › Steering Gear System › Follow-up Assembly
Issued 10 March 2014 Resolved
Test steering control transfer system IAW approved periodic safety test procedures.
Action required: 705 - Other - as specified
Due 24 March 2014
Resolved 13 March 2014
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Instructions
Issued 9 February 2012 Resolved
Provide instructions for the manual operation of the Fixed Co2 System in the engine room and label the control valves accordingly.
Due 8 March 2012
Resolved 8 March 2012
Resolution: Received call from [name withheld] stating that controls had been properly relabled
Fire Fighting › Ventilation Systems › Ducts
Issued 19 September 2011 Resolved
Demonstrate proper operation of ENG room ventilation shut-down near ENG room door.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 September 2011
Resolution: Proper operation of RNG room ventilation shut-down demonstrated.
Lifesaving › Rescue Boat › Propulsion Engine
Issued 19 September 2011 Resolved
Provide lanyard for rescue boat engine.
Action required: 705 - Other - as specified
Due 29 September 2011
Resolved 4 October 2011
Resolution: Lanyard was provide for the rescue boat engine.
Engineering › Diesel Engine (propulsion-direct drive) › Governor
Issued 24 January 2011 Resolved
Provide proper identification placards IWO propulsion control system (operating stations).
Action required: 705 - Other - as specified
Due 23 July 2011
Resolved 19 September 2011
Documentation › Manuals/Policy Documentation › Vessel Specific Watch Policy/Procedures
Issued 24 January 2011 Resolved
Resubmit propulsion control operations manual to reflect as built controls, indicators and configuration.
Action required: 705 - Other - as specified
Due 23 June 2011
Resolved 13 February 2013
Documentation › Manuals/Policy Documentation › Vessel Specific Watch Policy/Procedures
Issued 24 January 2011 Resolved
Re-submit DVTP to address missing MDE load signal and shaft speed inputs.
Action required: 705 - Other - as specified
Due 23 July 2011
Resolved 22 August 2012
Communications › Internal Communications System › Sound-powered Telephone
Issued 24 January 2011 Resolved
Provide proper sound powered phones IWO local voith control spaces.
Action required: 705 - Other - as specified
Due 23 July 2011
Resolved 19 September 2011
Resolution: Sound powered phones installed and working properly.
Documentation › Manuals/Policy Documentation › Vessel Specific Watch Policy/Procedures
Issued 24 January 2011 Resolved
Submit as built drawings IWO propulsion control system.
Action required: 705 - Other - as specified
Due 23 July 2011
Resolved 13 February 2013
Fire Fighting › Structural Fire Protection - General › Cooking Area
Issued 19 October 2010 Resolved
Adjust fire door IWO galley entrance. The door is not self closing and does not latch. The BLKHD is reported to be warped, precluding sufficient adjustment. Repair within the next 30 days to the satisfaction of the attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 January 2011
Resolved 28 June 2011
Engineering › Diesel Engine (propulsion-reduction gear) › Governor
Issued 7 October 2010 Resolved
On or before the next dry dock, install main engine shut downs at specified locations IAW 46 CFR 62.35-5.
Action required: 705 - Other - as specified
Resolved 19 September 2011
Resolution: Main engine shut-downs on bridge installed and working properly.
Construction/Loadline › Structures › Ventilators
Issued 11 May 2009 Resolved
Modify E/R vent closures to ensure secure fit (fitted plates are loose).
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 20 June 2009
Resolved 26 August 2009
Resolution: Corrected.
Fire Fighting › Means of Escape › Escape Route Signs
Issued 2 February 2009 Resolved
Properly stencil the emergency escapes through out the engineering spaces as needed, approx. four not marked.
Action required: 705 - Other - as specified
Due 9 February 2009
Resolved 2 March 2009
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Instructions
Issued 2 February 2009 Resolved
Post operating instructions for the fixed CO2 system local operation to include labeling of the control valves.
Action required: 705 - Other - as specified
Due 9 February 2009
Resolved 2 March 2009
Fire Fighting › Fire Main › Condition
Issued 24 November 2008 Resolved
Prior to the carriage of vehicles on the tunnel side driveway repair the leak in the supply piping for the vehicle deck sprinkler system.
Action required: 705 - Other - as specified
Due 26 November 2008
Resolved 25 November 2008
Engineering › Diesel Engine (propulsion-direct drive) › Piping (air intake)
Issued 28 February 2007 Resolved
B-end main diesel engine over speed when activated shut down the engine by means of fuel rack only, the air box shut down solenoid did not operate as designed. Repair/renew shut down solenoid, test and provide documentation to USCG.
Action required: 705 - Other - as specified
Due 28 February 2007
Resolved 28 February 2007
Resolution: Received fax from NC DOT Ferry Div. stating; solenoid replaced and tested sat.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 28 February 2007 Resolved
A-end Life Jacket storage locker door wasted IWO bottom securing dog; dog was difficult to operate and allow access to L/J - repair/replace hardware as needed to allow door to properly operate.
Action required: 705 - Other - as specified
Due 8 March 2007
Resolved 4 March 2007
Resolution: NCDOT performed maintenance to the bottom securing dog as required by the Marine Insepctor.
Personnel › Manning/Qualifications
Issued 27 September 2002 Resolved
While operating on the Southport, NC to Fort Fisher, NC ferry route, vessel must have at a minimum 1 Master, 1 Chief Engineer, 2 Deckhands and 1 Oiler. The Oiler may be non-certificated. LEGACY COMPONENT DESC: Minimum Safe Manning
Due 31 December 2002
Resolved 28 October 2003
Lifesaving
Issued 10 April 1998 Resolved
VESSEL SHALL HAVE ON BOARD AN APPROVED RESCUE BOAT WITH REQUIRED EQUIPMENT AS REQUIRED BY 46 CFR 199.630(i) AND 46 CFR 199.620(j), PRIOR TO PLACING THE VESSEL INTO OPERATION.
Condition: Unknown
Due 17 November 1998
Resolved 17 November 1998
Navigation
Issued 10 April 1998 Resolved
VESSEL SHALL INSTALL AND PROVE PROPER OPERATION OF STEERING ALARMS IN THE PILOT HOUSE AS REQUIRED BY 46 CFR 58.25-25(d).
Condition: Unknown
Due 21 May 1998
Resolved 17 November 1998
Lifesaving
Issued 10 April 1998 Resolved
VESSEL TO HAVE ON BOARD A TRAINING MANUAL AND OR ADUIOVISUAL AIDS TO COMPLYWITH 46 CFR 199.180.
Condition: Unknown
Due 2 November 1998
Resolved 17 November 1998
Documentation
Issued 10 April 1998 Resolved
VESSEL SHALL HAVE ON BOARD AND POST AN APPROVED STABILITY LETTER AS REQUIRED BY 46 CFR 170.120. REQUIREMENT SHALL BE SATISFIED PRIOR TO PLACINGTHE VESSEL INTO OPERATION.
Condition: Unknown
Due 21 May 1998
Resolved 17 November 1998

Casualty record · 32

16 December 2003Routine · role: Involved in a Marine Casualty · 1 injured · activity 2016346
24 October 2004Significant Marine Casualty · role: Involved in a Marine Casualty · serious marine incident, as classified · activity 2228797
9 May 2005Routine · role: Involved in a Marine Casualty · activity 2363059
30 September 2005Routine · role: Involved in a Marine Casualty · activity 2508291
11 July 2007Routine · role: Involved in a Marine Casualty · activity 2997018
22 September 2008Routine · role: Subject to Marine Inspection · activity 3332182
31 January 2009Routine · role: Involved in a Marine Casualty · activity 3412181
8 February 2009Routine · role: Involved in a Marine Casualty · activity 3424429
11 February 2009Routine · role: Involved in a Marine Casualty · activity 3674308
12 February 2009Routine · role: Involved in a Marine Casualty · activity 3424561
3 July 2009Routine · role: Involved in a Marine Casualty · activity 3528850
5 January 2010Routine · role: Involved in a Marine Casualty · activity 3659463
31 August 2011Routine · role: Involved in a Marine Casualty · activity 4132572
4 December 2012Routine · role: Involved in a Marine Casualty · activity 4500154
27 March 2013Routine · role: Involved in a Marine Casualty · activity 4557663
11 April 2013Routine · role: Involved in a Marine Casualty · activity 4567003
15 April 2013Routine · role: Involved in a Marine Casualty · activity 4570301
4 December 2013Routine · role: Involved in a Marine Casualty · activity 4771346
7 January 2014Routine · role: Involved in a Marine Casualty · activity 4779363
13 January 2014Routine · role: Involved in a Marine Casualty · activity 4781950
15 September 2017Routine · role: Involved in a Marine Casualty · activity 6277810
25 March 2019Routine · role: Involved in a Marine Casualty · activity 6649581
5 May 2019Routine · role: Involved in a Marine Casualty · activity 6680656
4 July 2019Routine · role: Involved in a Marine Casualty · activity 6742103
18 October 2019Routine · role: Involved in a Marine Casualty · activity 6839421
18 December 2019Routine · role: Involved in a Marine Casualty · activity 6884336
30 September 2020Routine · role: Involved in a Marine Casualty · activity 7076032
3 February 2021Routine · role: Involved in a Marine Casualty · activity 7135899
20 March 2021Routine · role: Involved in a Marine Casualty · activity 7171990
19 February 2022Routine · role: Involved in a Marine Casualty · activity 7400139
17 June 2022Routine · role: Involved in a Marine Casualty · activity 7488447
25 June 2022Routine · role: Involved in a Marine Casualty · activity 7488863
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.