← All vessels
NEUSE
Passenger (Inspected) · Passenger Ship class · Built 1990s · USCG East District (CGD-E) · Other hulls named NEUSE
NEUSE is a 1998 passenger vessel (inspected). The Coast Guard has recorded 143 inspections since 1997, most recently in July 2024, along with 97 deficiencies and 32 casualty investigations between 2003 and 2022.
Records from 1997 to 2024. Most recent: inspection, 18 July 2024.
- Built
- 1998
- Last inspected
- 18 July 2024
- Documentation
- Valid · documentation file of 10 September 2026
- Inspections
- 143
- Deficiencies
- 97 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
- Casualties
- 32 investigations · 2003–2022
Identity
1051627
WCY3174
453787
Flag
UNITED STATES
367341890
Maury page id
psix-453787
Inspections, by type
…with no type recorded33
Years with a record
27 calendar years (1997–2024)
The 143 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.
Documentation record
Registered dimensions (L × B × D)167.7 ft × 44.0 ft × 10.5 ft
Registered tonnagegross 380 / net 295
ITC dimensions (L × B × D)167.7 ft × 44.0 ft × 10.5 ft
ITC tonnagegross 423 / net 151
BuilderSTEINER SHIPYARD INC · BAYOU LA BATRE, AL, UNITED STATES · built 1998
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portMANNS HARBOR, NC
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 9 April 2026 · expires 31 May 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it151 - Convention (Subpart B), Net Ton
295 - Regulatory (Subpart C or D), Net Ton
423 - Convention (Subpart B), Gross Ton
380 - Regulatory (Subpart C or D), Gross Ton
295 - Regulatory (Subpart C or D), Net Ton
423 - Convention (Subpart B), Gross Ton
380 - Regulatory (Subpart C or D), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
WCY3174MMSI 367341890 · active · compulsorily equipped · granted 23 February 2018, expires 22 April 2028
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 143
18 July 2024
Re-Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7960986
25 April 2024
Re-Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7901216
22 January 2024
Administrative Inspection · Internal Structural Exam
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7852414
4 January 2024
COI Inspection · In-Service Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7846253
27 December 2023
Damage Survey · Deficiency Check
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7843369
19 October 2023
Re-Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7810963
13 July 2023
Re-Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7741239
19 April 2023
Deficiency Check · Damage Survey
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7671559
13 April 2023
Re-Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7667697
9 January 2023
Deficiency Check · COI Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7616279
19 October 2022
Re-Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7579565
31 August 2022
In-Service Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7547906
27 July 2022
Re-Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7509756
25 June 2022
Type not recorded
No type recorded · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7488863
25 June 2022
In-Service Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7488974
22 June 2022
In-Service Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7484076
17 June 2022
Damage Survey
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7480278
17 June 2022
Type not recorded
No type recorded · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7488447
21 April 2022
Re-Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7435174
4 April 2022
Deficiency Check · Damage Survey
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7425648
3 March 2022
In-Service Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7405670
19 February 2022
Deficiency Check · Damage Survey
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7398935
19 February 2022
Type not recorded
No type recorded · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7400139
19 January 2022
Deficiency Check · COI Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7376650
1 July 2021
Drydock Exam · Examination of Repairs · Internal Structural Exam
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7239619
20 March 2021
Deficiency Check · In-Service Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7160430
20 March 2021
Type not recorded
No type recorded · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7171990
4 February 2021
MTSA Verification · COI Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7135898
3 February 2021
Damage Survey · Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7135581
3 February 2021
Type not recorded
No type recorded · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7135899
30 October 2020
Re-Inspection · MTSA Verification · Deficiency Check
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7087253
30 September 2020
In-Service Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7068525
30 September 2020
Type not recorded
No type recorded · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7076032
20 August 2020
Deficiency Check · Re-Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7001380
19 July 2020
In-Service Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7014435
10 July 2020
Administrative Inspection
Administrative · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7002581
29 May 2020
Periodic Inspection · MTSA Verification · Deadweight Survey
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6923809
27 February 2020
MTSA Verification · COI Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6888890
18 December 2019
Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 6884336
5 December 2019
Re-Inspection · Administrative Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6867772
18 October 2019
Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 6839421
29 August 2019
Periodic Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6741486
4 July 2019
Type not recorded
No type recorded · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6742103
30 May 2019
Periodic Inspection · MTSA Verification
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6656602
5 May 2019
Type not recorded
No type recorded · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6680656
25 March 2019
Type not recorded
No type recorded · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6649581
25 March 2019
In-Service Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6649626
5 March 2019
COI Inspection · Administrative Inspection · MTSA Verification
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6636374
13 August 2018
Administrative Inspection
Administrative · Navigation Center · Activity 6510961
26 July 2018
Examination of Repairs · Hull Examination
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6491216
27 June 2018
Damage Survey · Administrative Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6458409
9 April 2018
MTSA Verification · COI Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6387813
21 February 2018
Administrative Inspection
Administrative · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6358706
14 February 2018
Re-Inspection · Administrative Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6354905
1 November 2017
Re-Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6298749
15 September 2017
Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 6277810
9 August 2017
Re-Inspection · Deficiency Check
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6234961
8 August 2017
Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 6236184
10 May 2017
COI Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6138728
8 February 2017
Re-Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6084460
30 December 2016
In-Service Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6064891
9 November 2016
Deficiency Check · Re-Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6038041
17 October 2016
Deficiency Check
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6024584
18 August 2016
Re-Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 5955460
10 May 2016
Spot Check · COI Inspection · Deficiency Check · MTSA Verification
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 5867237
14 January 2016
Examination of Repairs · Spot Check · Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 5797178
2 October 2015
Drydock Extension · Internal Structural Exam
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 5734567
30 October 2014
COI Inspection · MTSA Verification
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 5009455
16 October 2014
Examination of Repairs
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 5017551
7 August 2014
Re-Inspection · Deficiency Check · MTSA Verification
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 4946583
16 May 2014
Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 4864241
15 May 2014
Re-Inspection · MTSA Verification
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 4859444
10 March 2014
Deficiency Check · In-Service Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 4815339
9 May 2012
In-Service Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 4277141
9 February 2012
Re-Inspection · Administrative Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 4240902
19 September 2011
In-Service Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 4152536
31 August 2011
Type not recorded
No type recorded · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 4132572
24 January 2011
Construction Oversight
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 3932389
19 October 2010
MTSA Verification · MARPOL Annex I Examination · COI Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 3873084
7 October 2010
Administrative Inspection
Administrative · Marine Safety Unit Wilmington · USCG East District (CGD-E) · Activity 3865458
17 March 2010
Examination of Repairs · Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 3696811
22 January 2010
Drydock Extension
Administrative · Marine Safety Unit Wilmington · USCG East District (CGD-E) · Activity 3719933
7 January 2010
Administrative Inspection
Administrative · Sector North Carolina · USCG East District (CGD-E) · Activity 3660470
5 January 2010
Type not recorded
No type recorded · Marine Safety Unit Wilmington · USCG East District (CGD-E) · Activity 3659463
21 December 2009
Examination of Repairs
Physical examination · Marine Safety Unit Wilmington · USCG East District (CGD-E) · Activity 3656830
3 July 2009
Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 3528850
11 May 2009
COI Inspection · MTSA Verification
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 3472140
12 February 2009
Type not recorded
No type recorded · Marine Safety Unit Wilmington · USCG East District (CGD-E) · Activity 3424561
11 February 2009
Type not recorded
No type recorded · Marine Safety Unit Wilmington · USCG East District (CGD-E) · Activity 3674308
8 February 2009
Type not recorded
No type recorded · Marine Safety Unit Wilmington · USCG East District (CGD-E) · Activity 3424429
2 February 2009
Re-Inspection
Physical examination · Marine Safety Unit Wilmington · USCG East District (CGD-E) · Activity 3404164
31 January 2009
Type not recorded
No type recorded · Marine Safety Unit Wilmington · USCG East District (CGD-E) · Activity 3412181
25 November 2008
Examination of Repairs
Physical examination · Marine Safety Unit Wilmington · USCG East District (CGD-E) · Activity 3369227
22 September 2008
Type not recorded
No type recorded · Marine Safety Unit Wilmington · USCG East District (CGD-E) · Activity 3332182
9 September 2008
Periodic Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 3323479
20 February 2008
COI Inspection · Hull Examination · MTSA Verification · Internal Structural Exam
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 3150643
11 December 2007
Periodic Inspection
Physical examination · Marine Safety Unit Wilmington · USCG East District (CGD-E) · Activity 3114746
13 July 2007
Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 3049646
11 July 2007
Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 2997018
29 March 2007
Damage Survey
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 2897694
28 February 2007
MTSA Verification · COI Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 2880582
7 September 2006
Periodic Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 2772174
3 March 2006
MTSA Verification · COI Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 2594032
12 October 2005
Periodic Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 2513538
30 September 2005
Type not recorded
No type recorded · Marine Safety Unit Wilmington · USCG East District (CGD-E) · Activity 2508291
9 May 2005
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 2363059
4 March 2005
COI Inspection · MTSA Verification
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 2299273
23 February 2005
Administrative Inspection
Administrative · MSO WILMINGTON · USCG East District (CGD-E) · Activity 2297770
8 February 2005
Hull Examination
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 2290051
25 January 2005
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 2280498
15 November 2004
Administrative Inspection
Administrative · MSO WILMINGTON · USCG East District (CGD-E) · Activity 2241266
24 October 2004
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 2228797
1 September 2004
Periodic Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 2184041
10 March 2004
COI Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 2007506
16 December 2003
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 2016346
8 December 2003
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1961091
10 September 2003
Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1918451
18 March 2003
COI Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1762661
21 January 2003
Hull Examination
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1735095
4 October 2002
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1686824
27 September 2002
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1681218
21 May 2002
Administrative Inspection
Administrative · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1619033
21 March 2002
COI Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1485058
30 August 2001
Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1420575
28 June 2001
Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1465667
15 May 2001
Deficiency Check
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1064965
11 April 2001
Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1433800
27 March 2001
COI Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1441806
11 January 2001
Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1450565
22 September 2000
Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1449377
30 June 2000
Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1403176
5 April 2000
COI Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1439023
10 January 2000
Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1450385
9 October 1999
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 56053
7 October 1999
Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1393253
1 July 1999
Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1406528
8 April 1999
COI Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1413509
30 December 1998
Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1462714
14 October 1998
Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1416774
7 July 1998
Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1128474
30 April 1998
Deficiency Check
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 792277
10 April 1998
Initial Construction-Excluding Oversight · Deadweight Survey · Initial Certification · Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1467574
26 September 1997
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1117529
Deficiency record · 97
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 27 December 2023
Resolved
The installation of all systems of a marine engineering nature, together with the details of design, construction, and installation, shall be in accordance with the requirements of subchapter F (Marine Engineering) of this chapter. NCDOT reported "B" end shaft bearing was slipping and sparking during morning checks. NCDOT must conduct repairs IAW manufacturers specifications ans in-kind equipment. Provide proof of repairs to attending marine inspector.
If vessel needs to get underway for repairs, notify the MSD Ft. Macon office for request/approval.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 19 April 2023
Resolved
All piping, valves, and fittings shall meet the applicable requirements of subchapter F (Marine Engineering) of this chapter. Vessel master made a report stating during fire drill, crew discovered fire main piping located in the engine room had a pin hole leak. Vessel is currently moored at Cherry Branch.
NCDOT must provide repair report stating the correction to the vessel and hydro results of the pipe (1.5 times safe working pressure). Vessel master will notify MSD Fort Macon as conditions change.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 18 January 2023
Resolved
Before the vessel leaves port and at all times during the voyage, each lifesaving appliance must be in working order and ready for immediate use. Retro-reflective tape on forty adult sized life jackets were found wasted. Vessel restricted to 273 passengers.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 18 January 2023
Resolved
All enclosed spaces within the vessel shall be properly vented or ventilated. Means shall be provided to close off all vents and ventilators. Closure for MSD space not properly working with middle louver fin.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 19 October 2022
Resolved
All distribution valves and controls shall be of an approved type. All controls shall be suitably protected. Remote control boxes for E/R and EDG Fixed fire extinguishing systems not properly installed. Safety/security glass not secured with second hold down bracket.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 19 October 2022
Resolved
Doors shall have a latch with a minimum throw of 3-4 inch which can be operated from either side of the door. The limit mechanism on outboard door handle for starboard side EDG space was found broken. Make effective repairs.
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 31 August 2022
Resolved
The emergency power source must meet table 112.05-5(a)....Passenger vessels other than Ocean, Great Lakes, or coastwise and not on an international voyage must have a final emergency power source capable of operating for a minimum of 8 hours or twice the time of run, which ever is less. Vessel's representative reported the emergency generator overheats causing the engine to shutdown approximately 15 minutes into running with a load. Provide a final emergency power source capable of operating for a minimum of 8 hours or twice the time of run, which ever is less.
09 - Working and Living Conditions › 092 - Working Conditions › Ventilation (Working spaces)
Issued 31 August 2022
Resolved
Each machinery space must be ventilated to ensure that, when machinery or boilers are operated at full power in all weather including heavy weather, an adequate supply of air is maintained for the operation of the machinery. Vessel's representative reported that the emergency diesel generator has to operate with the emergency generator space's doors open to prevent the engine from overheating. Troubleshoot and provide adequate ventilation to prevent emergency generator from overheating.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 25 June 2022
Resolved
A survey either general or partial, according to the circumstances, shall be made every time an accident occurs or a defect is discovered which affects the safety of the vessel or the efficacy or completeness of its life-saving appliances, fire-fighting, or other equipment. Master reported the #1 steering system gave alarm during transit and automatically shifted to the #2 steering system. No loss of steering was reported. The vessel moored at Cherry Branch. Electricians conducted verification of the system. A fault code for the "B" end transverse thrust was noted. A calibration of the potentiometer and system was completed. After which, the fault was cleared. The system was tested and found working satisfactory; dockside and post underway trails by the crew.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 22 June 2022
Resolved
A survey either general or partial, according to the circumstances, shall be made every time an accident occurs or a defect is discovered which affects the safety of the vessel or the efficacy or completeness of its life-saving appliances, fire-fighting, or other equipment. Master reported the #1 steering system gave alarm during transit and automatically shifted to the #2 steering system. No loss of steering was reported. The vessel moored at Cherry Branch. Electricians conducted verification of the system. A fault code for the "B" end transverse thrust was noted. A calibration of the potentiometer and system was completed. After which, the fault was cleared. The system was tested and found working satisfactory; dockside and post underway trails by the crew.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for rescue boats
Issued 17 June 2022
Resolved
A survey either general or partial, according to the circumstances, shall be made every time an accident occurs or a defect is discovered which affects the safety of the vessel or the efficacy or completeness of its life-saving appliances, fire-fighting, or other equipment. Crew reported during checks of the vessels rescue boat. The rescue boat davit manual winch safety cut out switch (for the handle) was found inoperative, further investigation revealed the switch was corroded. Maintenance replaced the switch in-kind and tested satisfactory. The master provided objective evidence and an attestation reporting satisfactory operation.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 4 April 2022
Resolved
A survey shall be made every time an accident occurs or a defect is discovered which affects the safety of the vessel. Master reported hitting loading ramp while mooring up. MI's must conducted survey of vessel IVO contact area, prior to departure.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 3 March 2022
Resolved
The Master shall take all precautions to see that automobiles or other vehicles have their motors turned off when ferry is underway and motors shall not be started until ferry is secured. In addition, vehicles at each end end shall have wheels securely blocked. MI witnessed vehicles not properly blocked and vehicles were started prior to docked.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 19 February 2022
Resolved
Each self propelled vessel must have both main and auxiliary steering gear, except when the main steering gear includes two or more identical power units. Master reported the NR1 power unit had an unknown fault causing it to trip offline and automatically switch to the NR2 power unit. Make permanent repairs to steering system. Provide technician's report of findings and repair. Prove proper operation of steering system to USCG Marine Inspector.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 19 January 2022
Resolved
Fire damper on A end of EDG bulhead (intake) is missing hardware IAW 46CFR72.05-50(b).
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 19 January 2022
Resolved
Excesive trash and debris found in bilges IAW 46CFR71.25-45.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machines/parts
Issued 19 January 2022
Resolved
Deck plates in E.R. not properly installed IAW 46CFR72.40-20.
09 - Working and Living Conditions › 091 - Living Conditions › Ventilation (Accommodation)
Issued 19 January 2022
Resolved
Women's head exhaust vent screening painted over IAW 46CFR72.15-20(a).
08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 19 January 2022
Resolved
Alarm Panel on Bridge B-end control station has faulty alarm for "E-Gen Overspeed" IAW 46CFR111.12-11.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 19 January 2022
Resolved
Loose Connections on battery terminal in EDG space IAW 46CFR111.60-17.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 19 January 2022
Resolved
Missing bracket on bilge suction throughout vessel IAW 46CFR70.20-1.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 19 January 2022
Resolved
Rescue Boat davit has chafed wire on limit switch IAW 46CFR70.28-1.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 20 March 2021
Resolved
Master reported a steering fault on "B" end while in route to Cherry Branch, during operations. Determine cause of fault and make proper repairs to the satisfaction of the coast guard. Prior to passengers operations.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 20 March 2021
Resolved
Replace or repair "B" control head (lever) is loose not working properly, to the satisfaction of the coast guard.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 22 February 2021
Resolved
First aid kit. Pilothouse and engine room expired meds.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 22 February 2021
Resolved
Main deck engine room watertight door unable to secure. Adjust dogs.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 4 February 2021
Resolved
During testing/operation, the rescue boat died and failed to restart. Prove proper operation to the satisfaction of the attending Marine Inspector
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 3 February 2021
Resolved
Received report of a throttle/steering failure while carrying passengers. Throubleshoot and report finding to marine inspector (MI) prior to requiring attendance. Once permanent repairs are conducted,test all related systems and contact CG MI for attendance of final operational testing prior to carrying passengers.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 3 February 2021
Resolved
After allision with bulkhead, three frames on the underside of the starboard deck on the A end were buckled and one weld was broken. Make permenant repairs to the satisfaction of the attending Marine Inspector.
09 - Working and Living Conditions › 091 - Living Conditions › Sanitary Facilities
Issued 18 November 2020
Resolved
Womens Restroom door is not closing properly
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 18 November 2020
Resolved
Determine "A" end upper navigational light. Electrical issue/not operating properly
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 18 November 2020
Resolved
A and B gauge lines are loose.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 18 November 2020
Resolved
Pilot valve CO2 was loose in the fuel tank void.
09 - Working and Living Conditions › 091 - Living Conditions › Access/structure
Issued 18 November 2020
Resolved
Loose gear blocking emergency escape void #2A
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 18 November 2020
Resolved
During testing/Mob rescue boat failed to start. Prove proper operation to the satisfaction of the attending Marine Inspector.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for rescue boats
Issued 18 November 2020
Resolved
Rescue boat davit failed to retrieve rescue boat after rescue boat was deployed. Prove operation of the davit to the satisfaction of the attending Marine Inspector.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 30 September 2020
Resolved
While mooring No. 1 generator oversped and would not maintain electrical load as designed. Make effective repairs and prove proper operation to the attending Marine Inspector. Vessel is restricted from carrying passengers.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 20 August 2020
Resolved
Upper deck A end storage locker missing hardware.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 20 August 2020
Resolved
Broken Fire Ext. mount rescue boat (securing strap).
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 20 August 2020
Resolved
Rescue boat securing straps wasted/worn.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 20 August 2020
Resolved
Engine room WTD will not properly close due to adjustment/ alignment issues. Prove proper operation.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 20 August 2020
Resolved
Crews first aid kit had expired medication.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 20 August 2020
Resolved
All water tight doors in the engineering spaces were witnessed as open and unattended, during inspection this date.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 20 August 2020
Resolved
PTSP's were not availible for inspection, because vessel was on the run. A requirement for crew to carry out specific testing procedure for voith units and to provide attestation from captain once witnessed as satisfactory.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 20 August 2020
Resolved
Portable fire extinguishers in pilot house, #02, #03, and #17 had loose hoses, when spot checked this date.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 27 February 2020
Resolved
Change out block tackle on the rescue boat ladder wasted and worn.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Lashing material
Issued 27 February 2020
Resolved
Replace the forward and aft cargo netting which was damaged and worn.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 27 February 2020
Resolved
Install backflow preventer on the saltwater to fresh water filtration piping.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 5 December 2019
Resolved
The Starboard Engine Room door vent closure does not close properly. Make repairs to the satisfaction of attending MI.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 29 August 2019
Resolved
Install suitable exhaust lagging IWO MDE exhaust side shell penitrations.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificate for medical first aid
Issued 29 August 2019
Resolved
Provide CPR first aid cards.
02 - Structural Conditions › N/A - No Subsystem › Stability/strength/loading information and instruments
Issued 12 March 2019
Resolved
Vessel has not completed a new deadweight survey as required by MSC letter dated September 13,2018 (serial: H2-1803524) and MSC Technical Note 4-95. The new survey is required due to an aggregate weight change in excess of 2%. According to MSC letter dated February 20,2007 (serial: H2-0700482), M/V NEUSE had receive alterations in 2007 amounting to an aggregate weight change of 1.02%. This previous change along with the voith unit soft patch installations, deck wear plate modifications, and other items completed since 2007 exceeds the 2% threshold. Provide new calculations.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 13 August 2018
Resolved
The vessel is currently Not broadcasting (1) IMO number.
Fire Fighting › Ventilation Systems › Ducts
Issued 2 May 2018
Resolved
EDG space vent closures broken spring and will not close 100%.
Stability › Watertight Integrity › Weathertight Enclosure
Issued 2 May 2018
Resolved
B-end escape hatch dog cracked. Yard period in June conduct repairs.
Stability › Watertight Integrity › Weathertight Enclosure
Issued 2 May 2018
Resolved
A-end escape hatch leaking
Lifesaving › Rigid Liferafts › Weak Link
Issued 2 May 2018
Resolved
Liferaft straps deteriorated on three rafts.
Fire Fighting › Portable CO2 Fire Extinguisher › Condition
Issued 2 May 2018
Resolved
Ext #9 wasted horn clip
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 2 May 2018
Resolved
Harndrail B-end 01 deck stanchion cracked. Repair in Jane 2018 Yard
Lifesaving › Rescue Boat Equipment › Rescue Quoit
Issued 2 May 2018
Resolved
Quoit ring deteriorated
Engineering › Fuel Oil Storage/Transfer System › Valve
Issued 2 May 2018
Resolved
Fuel remote shutoff link-age temp repaired. replace in yard Jun 2018
Communications › Alarms/Indicators › Engine RPM Gauge/Indicator
Issued 1 November 2017
Resolved
The #2 SSDG RPM gauge in not working; make the necessary repair and prove proper operation.
Communications › Alarms/Indicators › Lube Oil Low Pressure Alarm
Issued 9 August 2017
Resolved
#1 SSDG low L/O shutdown did not secure the engine; make repairs and prove proper operation.
Lifesaving › Lifebuoys › Serviceable
Issued 9 August 2017
Resolved
The life buoy on the "B" end is failing at the inner seam; replace the life buoy and ensure it is properly marked.
Electrical › Electrical Distribution System (service) › Wiring
Issued 9 August 2017
Resolved
Properly terminate the dead end wires in the #2 SSDG control panel and the EDG control panel.
Fire Fighting › Ventilation Systems › Ventilation Fire Dampers
Issued 9 August 2017
Resolved
Ventilation closure IWO the emergency generator compartment is not closing as designed; repair as necessary and prove proper operation.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 9 November 2016
Resolved
Provide a cover for the junction box under the "A" end console on the bridge.
Communications › Alarms/Indicators › Lube Oil Low Pressure Alarm
Issued 9 November 2016
Resolved
The loss of lube oil pressure shut down for the "A" end main engine did not function as designed, make the necessary repairs.
Electrical › Electrical Distribution System (service) › Distribution Panel Bus
Issued 9 November 2016
Resolved
The breaker panel index card in the storage room located within the passenger accommodation space is not properly labeled with amperages; make the necessary corrections.
Engineering › Fuel Oil Service System › Hose
Issued 9 November 2016
Resolved
Provide approved type hose (SAE J-1942) for the following machinery; (1) on the emergency generator, (1)on the "A" end main engine, (1) on the "B" end main engine, and (3)on the "B" end generator.
Electrical › Electrical Distribution System (emergency) › Distribution Panel Bus
Issued 30 October 2014
Resolved
Verify that all required equipment on the E-bus panel in the pilothouse are operating as required or properly labeled as needed.
Engineering › Diesel Engine (propulsion-reduction gear) › Emergency shutdown
Issued 7 August 2014
Resolved
During exam we were unable to see either main diesel engines shut down during low lube oil test as required. They only gave a visual/audible alarm. Vessel is to come into compliance and demonstrate proof of low lube oil audible/visual alarm and shutdown for both main diesel engines in the presence of a Coast Guard Marine Inspector along with meeting the requirements of 46 CFR 58.05-10.
Fire Fighting › Ventilation Systems › Operating Controls
Issued 7 August 2014
Resolved
Louvers to EDG need to operate properly while EDG is running and shutdown to include closing properly. Until cleared Chief engineer to log in engineer's log anytime EDG runs that both louvers are closed and verified closed after EDG is shutdown.
Electrical › Electrical Distribution System (service) › Wiring
Issued 15 May 2014
Resolved
Properly terminate dead end wires under bridge steering consoles
Engineering › Non-conventional Propulsion/Steering › Base (cycloidal)
Issued 10 March 2014
Resolved
Have technician troubleshoot steering control transfer system
Engineering › Steering Gear System › Follow-up Assembly
Issued 10 March 2014
Resolved
Test steering control transfer system IAW approved periodic safety test procedures.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Instructions
Issued 9 February 2012
Resolved
Provide instructions for the manual operation of the Fixed Co2 System in the engine room and label the control valves accordingly.
Fire Fighting › Ventilation Systems › Ducts
Issued 19 September 2011
Resolved
Demonstrate proper operation of ENG room ventilation shut-down near ENG room door.
Lifesaving › Rescue Boat › Propulsion Engine
Issued 19 September 2011
Resolved
Provide lanyard for rescue boat engine.
Engineering › Diesel Engine (propulsion-direct drive) › Governor
Issued 24 January 2011
Resolved
Provide proper identification placards IWO propulsion control system (operating stations).
Documentation › Manuals/Policy Documentation › Vessel Specific Watch Policy/Procedures
Issued 24 January 2011
Resolved
Resubmit propulsion control operations manual to reflect as built controls, indicators and configuration.
Documentation › Manuals/Policy Documentation › Vessel Specific Watch Policy/Procedures
Issued 24 January 2011
Resolved
Re-submit DVTP to address missing MDE load signal and shaft speed inputs.
Communications › Internal Communications System › Sound-powered Telephone
Issued 24 January 2011
Resolved
Provide proper sound powered phones IWO local voith control spaces.
Documentation › Manuals/Policy Documentation › Vessel Specific Watch Policy/Procedures
Issued 24 January 2011
Resolved
Submit as built drawings IWO propulsion control system.
Fire Fighting › Structural Fire Protection - General › Cooking Area
Issued 19 October 2010
Resolved
Adjust fire door IWO galley entrance. The door is not self closing and does not latch. The BLKHD is reported to be warped, precluding sufficient adjustment. Repair within the next 30 days to the satisfaction of the attending marine inspector.
Engineering › Diesel Engine (propulsion-reduction gear) › Governor
Issued 7 October 2010
Resolved
On or before the next dry dock, install main engine shut downs at specified locations IAW 46 CFR 62.35-5.
Construction/Loadline › Structures › Ventilators
Issued 11 May 2009
Resolved
Modify E/R vent closures to ensure secure fit (fitted plates are loose).
Fire Fighting › Means of Escape › Escape Route Signs
Issued 2 February 2009
Resolved
Properly stencil the emergency escapes through out the engineering spaces as needed, approx. four not marked.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Instructions
Issued 2 February 2009
Resolved
Post operating instructions for the fixed CO2 system local operation to include labeling of the control valves.
Fire Fighting › Fire Main › Condition
Issued 24 November 2008
Resolved
Prior to the carriage of vehicles on the tunnel side driveway repair the leak in the supply piping for the vehicle deck sprinkler system.
Engineering › Diesel Engine (propulsion-direct drive) › Piping (air intake)
Issued 28 February 2007
Resolved
B-end main diesel engine over speed when activated shut down the engine by means of fuel rack only, the air box shut down solenoid did not operate as designed. Repair/renew shut down solenoid, test and provide documentation to USCG.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 28 February 2007
Resolved
A-end Life Jacket storage locker door wasted IWO bottom securing dog; dog was difficult to operate and allow access to L/J - repair/replace hardware as needed to allow door to properly operate.
Personnel › Manning/Qualifications
Issued 27 September 2002
Resolved
While operating on the Southport, NC to Fort Fisher, NC ferry route, vessel must have at a minimum 1 Master, 1 Chief Engineer, 2 Deckhands and 1 Oiler. The Oiler may be non-certificated. LEGACY COMPONENT DESC: Minimum Safe Manning
Lifesaving
Issued 10 April 1998
Resolved
VESSEL SHALL HAVE ON BOARD AN APPROVED RESCUE BOAT WITH REQUIRED EQUIPMENT AS REQUIRED BY 46 CFR 199.630(i) AND 46 CFR 199.620(j), PRIOR TO PLACING THE VESSEL INTO OPERATION.
Navigation
Issued 10 April 1998
Resolved
VESSEL SHALL INSTALL AND PROVE PROPER OPERATION OF STEERING ALARMS IN THE PILOT HOUSE AS REQUIRED BY 46 CFR 58.25-25(d).
Lifesaving
Issued 10 April 1998
Resolved
VESSEL TO HAVE ON BOARD A TRAINING MANUAL AND OR ADUIOVISUAL AIDS TO COMPLYWITH 46 CFR 199.180.
Documentation
Issued 10 April 1998
Resolved
VESSEL SHALL HAVE ON BOARD AND POST AN APPROVED STABILITY LETTER AS REQUIRED BY 46 CFR 170.120. REQUIREMENT SHALL BE SATISFIED PRIOR TO PLACINGTHE VESSEL INTO OPERATION.
Casualty record · 32
16 December 2003Routine · role: Involved in a Marine Casualty · 1 injured · activity 2016346
24 October 2004Significant Marine Casualty · role: Involved in a Marine Casualty · serious marine incident, as classified · activity 2228797
9 May 2005Routine · role: Involved in a Marine Casualty · activity 2363059
30 September 2005Routine · role: Involved in a Marine Casualty · activity 2508291
11 July 2007Routine · role: Involved in a Marine Casualty · activity 2997018
22 September 2008Routine · role: Subject to Marine Inspection · activity 3332182
31 January 2009Routine · role: Involved in a Marine Casualty · activity 3412181
8 February 2009Routine · role: Involved in a Marine Casualty · activity 3424429
11 February 2009Routine · role: Involved in a Marine Casualty · activity 3674308
12 February 2009Routine · role: Involved in a Marine Casualty · activity 3424561
3 July 2009Routine · role: Involved in a Marine Casualty · activity 3528850
5 January 2010Routine · role: Involved in a Marine Casualty · activity 3659463
31 August 2011Routine · role: Involved in a Marine Casualty · activity 4132572
4 December 2012Routine · role: Involved in a Marine Casualty · activity 4500154
27 March 2013Routine · role: Involved in a Marine Casualty · activity 4557663
11 April 2013Routine · role: Involved in a Marine Casualty · activity 4567003
15 April 2013Routine · role: Involved in a Marine Casualty · activity 4570301
4 December 2013Routine · role: Involved in a Marine Casualty · activity 4771346
7 January 2014Routine · role: Involved in a Marine Casualty · activity 4779363
13 January 2014Routine · role: Involved in a Marine Casualty · activity 4781950
15 September 2017Routine · role: Involved in a Marine Casualty · activity 6277810
25 March 2019Routine · role: Involved in a Marine Casualty · activity 6649581
5 May 2019Routine · role: Involved in a Marine Casualty · activity 6680656
4 July 2019Routine · role: Involved in a Marine Casualty · activity 6742103
18 October 2019Routine · role: Involved in a Marine Casualty · activity 6839421
18 December 2019Routine · role: Involved in a Marine Casualty · activity 6884336
30 September 2020Routine · role: Involved in a Marine Casualty · activity 7076032
3 February 2021Routine · role: Involved in a Marine Casualty · activity 7135899
20 March 2021Routine · role: Involved in a Marine Casualty · activity 7171990
19 February 2022Routine · role: Involved in a Marine Casualty · activity 7400139
17 June 2022Routine · role: Involved in a Marine Casualty · activity 7488447
25 June 2022Routine · role: Involved in a Marine Casualty · activity 7488863
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.