Inspection history · 66
18 July 2024
Re-Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7960986
25 April 2024
Re-Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7901216
22 January 2024
Administrative Inspection · Internal Structural Exam
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7852414
4 January 2024
COI Inspection · In-Service Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7846253
27 December 2023
Damage Survey · Deficiency Check
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7843369
19 October 2023
Re-Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7810963
13 July 2023
Re-Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7741239
19 April 2023
Deficiency Check · Damage Survey
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7671559
13 April 2023
Re-Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7667697
9 January 2023
Deficiency Check · COI Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7616279
19 October 2022
Re-Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7579565
31 August 2022
In-Service Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7547906
27 July 2022
Re-Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7509756
25 June 2022
Type not recorded
No type recorded · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7488863
25 June 2022
In-Service Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7488974
22 June 2022
In-Service Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7484076
17 June 2022
Damage Survey
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7480278
17 June 2022
Type not recorded
No type recorded · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7488447
21 April 2022
Re-Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7435174
4 April 2022
Deficiency Check · Damage Survey
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7425648
3 March 2022
In-Service Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7405670
19 February 2022
Deficiency Check · Damage Survey
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7398935
19 February 2022
Type not recorded
No type recorded · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7400139
19 January 2022
Deficiency Check · COI Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7376650
1 July 2021
Drydock Exam · Examination of Repairs · Internal Structural Exam
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7239619
20 March 2021
Deficiency Check · In-Service Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7160430
20 March 2021
Type not recorded
No type recorded · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7171990
4 February 2021
MTSA Verification · COI Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7135898
3 February 2021
Damage Survey · Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7135581
3 February 2021
Type not recorded
No type recorded · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7135899
30 October 2020
Re-Inspection · MTSA Verification · Deficiency Check
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7087253
30 September 2020
In-Service Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7068525
30 September 2020
Type not recorded
No type recorded · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7076032
20 August 2020
Deficiency Check · Re-Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7001380
19 July 2020
In-Service Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7014435
10 July 2020
Administrative Inspection
Administrative · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7002581
29 May 2020
Periodic Inspection · MTSA Verification · Deadweight Survey
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6923809
27 February 2020
MTSA Verification · COI Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6888890
18 December 2019
Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 6884336
5 December 2019
Re-Inspection · Administrative Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6867772
18 October 2019
Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 6839421
29 August 2019
Periodic Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6741486
4 July 2019
Type not recorded
No type recorded · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6742103
30 May 2019
Periodic Inspection · MTSA Verification
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6656602
5 May 2019
Type not recorded
No type recorded · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6680656
25 March 2019
Type not recorded
No type recorded · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6649581
25 March 2019
In-Service Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6649626
5 March 2019
COI Inspection · Administrative Inspection · MTSA Verification
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6636374
13 August 2018
Administrative Inspection
Administrative · Navigation Center · Activity 6510961
26 July 2018
Examination of Repairs · Hull Examination
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6491216
27 June 2018
Damage Survey · Administrative Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6458409
9 April 2018
MTSA Verification · COI Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6387813
21 February 2018
Administrative Inspection
Administrative · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6358706
14 February 2018
Re-Inspection · Administrative Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6354905
1 November 2017
Re-Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6298749
15 September 2017
Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 6277810
9 August 2017
Re-Inspection · Deficiency Check
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6234961
8 August 2017
Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 6236184
10 May 2017
COI Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6138728
8 February 2017
Re-Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6084460
30 December 2016
In-Service Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6064891
9 November 2016
Deficiency Check · Re-Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6038041
17 October 2016
Deficiency Check
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6024584
18 August 2016
Re-Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 5955460
10 May 2016
Spot Check · COI Inspection · Deficiency Check · MTSA Verification
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 5867237
14 January 2016
Examination of Repairs · Spot Check · Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 5797178
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 27 December 2023
Resolved
The installation of all systems of a marine engineering nature, together with the details of design, construction, and installation, shall be in accordance with the requirements of subchapter F (Marine Engineering) of this chapter. NCDOT reported "B" end shaft bearing was slipping and sparking during morning checks. NCDOT must conduct repairs IAW manufacturers specifications ans in-kind equipment. Provide proof of repairs to attending marine inspector.
If vessel needs to get underway for repairs, notify the MSD Ft. Macon office for request/approval.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 January 2024
Resolution: MI's witnessed SAT operation of "B" end shaft. MI's also viewed pictures and videos of the repair. All SAT.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 19 April 2023
Resolved
All piping, valves, and fittings shall meet the applicable requirements of subchapter F (Marine Engineering) of this chapter. Vessel master made a report stating during fire drill, crew discovered fire main piping located in the engine room had a pin hole leak. Vessel is currently moored at Cherry Branch.
NCDOT must provide repair report stating the correction to the vessel and hydro results of the pipe (1.5 times safe working pressure). Vessel master will notify MSD Fort Macon as conditions change.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 April 2023
Resolution: NAGS HEAD DD DMI witnessed repairs and hydro of fire main pipe. MSD will verify repairs onboard vessel.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 18 January 2023
Resolved
Before the vessel leaves port and at all times during the voyage, each lifesaving appliance must be in working order and ready for immediate use. Retro-reflective tape on forty adult sized life jackets were found wasted. Vessel restricted to 273 passengers.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 February 2023
Resolved 23 February 2023
Resolution: 40 Life jackets renewed and onboard the vessel properly stowed.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 18 January 2023
Resolved
All enclosed spaces within the vessel shall be properly vented or ventilated. Means shall be provided to close off all vents and ventilators. Closure for MSD space not properly working with middle louver fin.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 February 2023
Resolved 9 February 2023
Resolution: Attended vsl and observed proper operation of louver.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 19 October 2022
Resolved
All distribution valves and controls shall be of an approved type. All controls shall be suitably protected. Remote control boxes for E/R and EDG Fixed fire extinguishing systems not properly installed. Safety/security glass not secured with second hold down bracket.
Action required: 705 - Other - as specified
Due 26 October 2022
Resolved 21 October 2022
Resolution: NCDOT installed second bracket on all control boxes. All SAT
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 19 October 2022
Resolved
Doors shall have a latch with a minimum throw of 3-4 inch which can be operated from either side of the door. The limit mechanism on outboard door handle for starboard side EDG space was found broken. Make effective repairs.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 November 2022
Resolved 21 October 2022
Resolution: Latch was welded to the limit mechanism.
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 31 August 2022
Resolved
The emergency power source must meet table 112.05-5(a)....Passenger vessels other than Ocean, Great Lakes, or coastwise and not on an international voyage must have a final emergency power source capable of operating for a minimum of 8 hours or twice the time of run, which ever is less. Vessel's representative reported the emergency generator overheats causing the engine to shutdown approximately 15 minutes into running with a load. Provide a final emergency power source capable of operating for a minimum of 8 hours or twice the time of run, which ever is less.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 September 2022
Resolved 18 January 2023
Resolution: Engine jacket water air cooled radiator was renewed. Conducted operational test; sat.
09 - Working and Living Conditions › 092 - Working Conditions › Ventilation (Working spaces)
Issued 31 August 2022
Resolved
Each machinery space must be ventilated to ensure that, when machinery or boilers are operated at full power in all weather including heavy weather, an adequate supply of air is maintained for the operation of the machinery. Vessel's representative reported that the emergency diesel generator has to operate with the emergency generator space's doors open to prevent the engine from overheating. Troubleshoot and provide adequate ventilation to prevent emergency generator from overheating.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 September 2022
Resolved 18 January 2023
Resolution: Conducted operational test for approx. 30 minutes under load. J/W tempartures were at normal readings on the gauge.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 25 June 2022
Resolved
A survey either general or partial, according to the circumstances, shall be made every time an accident occurs or a defect is discovered which affects the safety of the vessel or the efficacy or completeness of its life-saving appliances, fire-fighting, or other equipment. Master reported the #1 steering system gave alarm during transit and automatically shifted to the #2 steering system. No loss of steering was reported. The vessel moored at Cherry Branch. Electricians conducted verification of the system. A fault code for the "B" end transverse thrust was noted. A calibration of the potentiometer and system was completed. After which, the fault was cleared. The system was tested and found working satisfactory; dockside and post underway trails by the crew.
Action required: 10 - Deficiency Rectified
Resolved 26 June 2022
Resolution: Cleared to the satisfaction of the Coast Guard. See narrative for details AN 7488974
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 22 June 2022
Resolved
A survey either general or partial, according to the circumstances, shall be made every time an accident occurs or a defect is discovered which affects the safety of the vessel or the efficacy or completeness of its life-saving appliances, fire-fighting, or other equipment. Master reported the #1 steering system gave alarm during transit and automatically shifted to the #2 steering system. No loss of steering was reported. The vessel moored at Cherry Branch. Electricians conducted verification of the system. A fault code for the "B" end transverse thrust was noted. A calibration of the potentiometer and system was completed. After which, the fault was cleared. The system was tested and found working satisfactory; dockside and post underway trails by the crew.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 22 June 2022
Resolved 22 June 2022
Resolution: Cleared to the satisfaction of the Coast Guard. See narrative for details AN 7484076
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for rescue boats
Issued 17 June 2022
Resolved
A survey either general or partial, according to the circumstances, shall be made every time an accident occurs or a defect is discovered which affects the safety of the vessel or the efficacy or completeness of its life-saving appliances, fire-fighting, or other equipment. Crew reported during checks of the vessels rescue boat. The rescue boat davit manual winch safety cut out switch (for the handle) was found inoperative, further investigation revealed the switch was corroded. Maintenance replaced the switch in-kind and tested satisfactory. The master provided objective evidence and an attestation reporting satisfactory operation.
Condition: Damaged By Earlier Event
Action required: 10 - Deficiency Rectified
Due 17 June 2022
Resolved 17 June 2022
Resolution: The master provided objective evidence and an attestation reporting satisfactory operation of the equipment.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 4 April 2022
Resolved
A survey shall be made every time an accident occurs or a defect is discovered which affects the safety of the vessel. Master reported hitting loading ramp while mooring up. MI's must conducted survey of vessel IVO contact area, prior to departure.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 April 2022
Resolution: MI's conducted inspection IVO reported contacted area. Photos were taken and uploaded into MISLE. MI's found no structural damage and vessel was cleared to operate.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 3 March 2022
Resolved
The Master shall take all precautions to see that automobiles or other vehicles have their motors turned off when ferry is underway and motors shall not be started until ferry is secured. In addition, vehicles at each end end shall have wheels securely blocked. MI witnessed vehicles not properly blocked and vehicles were started prior to docked.
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Resolved 3 March 2022
Resolution: Prior to next scheduled trip, crew members properly blocked the vehicles at the ends of the ferry. Advised Master to ensure all vehicles motor were turned off while underway.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 19 February 2022
Resolved
Each self propelled vessel must have both main and auxiliary steering gear, except when the main steering gear includes two or more identical power units. Master reported the NR1 power unit had an unknown fault causing it to trip offline and automatically switch to the NR2 power unit. Make permanent repairs to steering system. Provide technician's report of findings and repair. Prove proper operation of steering system to USCG Marine Inspector.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 February 2022
Resolution: Maintenance replaced the "A End" lever. Satisfactory Operational test conducted.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 19 January 2022
Resolved
Fire damper on A end of EDG bulhead (intake) is missing hardware IAW 46CFR72.05-50(b).
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 January 2022
Resolved 19 January 2022
Resolution: Obtained pictures/evidence of installed bolts.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 19 January 2022
Resolved
Excesive trash and debris found in bilges IAW 46CFR71.25-45.
Action required: 10 - Deficiency Rectified
Due 19 January 2022
Resolved 19 January 2022
Resolution: Trash and Debris removed during inspection.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machines/parts
Issued 19 January 2022
Resolved
Deck plates in E.R. not properly installed IAW 46CFR72.40-20.
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 January 2022
Resolved 19 January 2022
Resolution: Recieved pictures/ evidence of proper installation.
09 - Working and Living Conditions › 091 - Living Conditions › Ventilation (Accommodation)
Issued 19 January 2022
Resolved
Women's head exhaust vent screening painted over IAW 46CFR72.15-20(a).
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 February 2022
Resolved 20 January 2022
Resolution: Sand blasted vent screen.
08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 19 January 2022
Resolved
Alarm Panel on Bridge B-end control station has faulty alarm for "E-Gen Overspeed" IAW 46CFR111.12-11.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 January 2022
Resolution: New card and power supply installed, test sat.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 19 January 2022
Resolved
Loose Connections on battery terminal in EDG space IAW 46CFR111.60-17.
Action required: 10 - Deficiency Rectified
Due 19 January 2022
Resolved 19 January 2022
Resolution: Observed proper adjustment.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 19 January 2022
Resolved
Missing bracket on bilge suction throughout vessel IAW 46CFR70.20-1.
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 January 2022
Resolved 19 January 2022
Resolution: Crew provided pictures/evidence of mounting hardware.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 19 January 2022
Resolved
Rescue Boat davit has chafed wire on limit switch IAW 46CFR70.28-1.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 January 2022
Resolved 19 January 2022
Resolution: Crew provided evidence/pictures of repaired wire.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 20 March 2021
Resolved
Master reported a steering fault on "B" end while in route to Cherry Branch, during operations. Determine cause of fault and make proper repairs to the satisfaction of the coast guard. Prior to passengers operations.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 March 2021
Resolved 22 March 2021
Resolution: Completed repairs and satisfactory operational testing during attendance of marine inspector.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 20 March 2021
Resolved
Replace or repair "B" control head (lever) is loose not working properly, to the satisfaction of the coast guard.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 April 2021
Resolved 26 March 2021
Resolution: Received, reviewed, and accepted objective evidence the requirement was satisfactorily rectified.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 22 February 2021
Resolved
First aid kit. Pilothouse and engine room expired meds.
Action required: 10 - Deficiency Rectified
Resolved 22 February 2021
Resolution: The first aid medications are now up to date.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 22 February 2021
Resolved
Main deck engine room watertight door unable to secure. Adjust dogs.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 February 2021
Resolution: The door dogs were adjusted and proved proper operation.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 4 February 2021
Resolved
During testing/operation, the rescue boat died and failed to restart. Prove proper operation to the satisfaction of the attending Marine Inspector
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 February 2021
Resolution: New engine intalled and test ran. IO received video objective evidence,
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 3 February 2021
Resolved
Received report of a throttle/steering failure while carrying passengers. Throubleshoot and report finding to marine inspector (MI) prior to requiring attendance. Once permanent repairs are conducted,test all related systems and contact CG MI for attendance of final operational testing prior to carrying passengers.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 February 2021
Resolution: New A end throttles installed and programed.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 3 February 2021
Resolved
After allision with bulkhead, three frames on the underside of the starboard deck on the A end were buckled and one weld was broken. Make permenant repairs to the satisfaction of the attending Marine Inspector.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 1 April 2021
Resolved 20 October 2021
Resolution: MI verified repairs and NDT at yard.
09 - Working and Living Conditions › 091 - Living Conditions › Sanitary Facilities
Issued 18 November 2020
Resolved
Womens Restroom door is not closing properly
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 November 2020
Resolved 30 November 2020
Resolution: The hinge was replaced and the door is now working.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 18 November 2020
Resolved
Determine "A" end upper navigational light. Electrical issue/not operating properly
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 18 November 2020
Resolution: Navigational light is working properly
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 18 November 2020
Resolved
A and B gauge lines are loose.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 18 November 2020
Resolution: The lines were properly tightened. Corrected on the spot.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 18 November 2020
Resolved
Pilot valve CO2 was loose in the fuel tank void.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 18 November 2020
Resolution: The pilot valve was properly tightened
09 - Working and Living Conditions › 091 - Living Conditions › Access/structure
Issued 18 November 2020
Resolved
Loose gear blocking emergency escape void #2A
Action required: 10 - Deficiency Rectified
Resolved 18 November 2020
Resolution: Loose gear was removed from the emergency escape.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 18 November 2020
Resolved
During testing/Mob rescue boat failed to start. Prove proper operation to the satisfaction of the attending Marine Inspector.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 November 2020
Resolution: The crew was able to properly start and operate the rescue boat.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for rescue boats
Issued 18 November 2020
Resolved
Rescue boat davit failed to retrieve rescue boat after rescue boat was deployed. Prove operation of the davit to the satisfaction of the attending Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 November 2020
Resolution: Limit switch was replaced and the davit was properly tested.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 30 September 2020
Resolved
While mooring No. 1 generator oversped and would not maintain electrical load as designed. Make effective repairs and prove proper operation to the attending Marine Inspector. Vessel is restricted from carrying passengers.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 September 2020
Resolved 30 September 2020
Resolution: Deficiency resolved to the satisfaction of the attending inspector.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 20 August 2020
Resolved
Upper deck A end storage locker missing hardware.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 September 2020
Resolved 20 August 2020
Resolution: The deficiency was resolved to the satisfaction of the attending inspector.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 20 August 2020
Resolved
Broken Fire Ext. mount rescue boat (securing strap).
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 September 2020
Resolved 20 August 2020
Resolution: The deficiency was resolved to the satisfaction of the attending inspector.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 20 August 2020
Resolved
Rescue boat securing straps wasted/worn.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 September 2020
Resolved 1 September 2020
Resolution: Rescue boat securing straps were renewed.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 20 August 2020
Resolved
Engine room WTD will not properly close due to adjustment/ alignment issues. Prove proper operation.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 August 2020
Resolved 20 August 2020
Resolution: The deficiency was resolved to the satisfaction of the attending inspector.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 20 August 2020
Resolved
Crews first aid kit had expired medication.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 September 2020
Resolved 20 August 2020
Resolution: The deficiency was resolved to the satisfaction of the attending inspector.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 20 August 2020
Resolved
All water tight doors in the engineering spaces were witnessed as open and unattended, during inspection this date.
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Due 20 August 2020
Resolved 20 August 2020
Resolution: The deficiency was resolved to the satisfaction of the attending inspector.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 20 August 2020
Resolved
PTSP's were not availible for inspection, because vessel was on the run. A requirement for crew to carry out specific testing procedure for voith units and to provide attestation from captain once witnessed as satisfactory.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 September 2020
Resolved 24 August 2020
Resolution: E-mail provided with logging of PSTP testing and [name withheld].
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 20 August 2020
Resolved
Portable fire extinguishers in pilot house, #02, #03, and #17 had loose hoses, when spot checked this date.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 August 2020
Resolved 20 August 2020
Resolution: The deficiency was resolved to the satisfaction of the attending inspector.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 27 February 2020
Resolved
Change out block tackle on the rescue boat ladder wasted and worn.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 12 March 2020
Resolved 3 April 2020
Resolution: Received, reviewed, and accepted objective evidence from company proving the outstanding item was resolved satisfactory.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Lashing material
Issued 27 February 2020
Resolved
Replace the forward and aft cargo netting which was damaged and worn.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 February 2020
Resolved 3 April 2020
Resolution: Received, reviewed, and accepted objective evidence from company proving the outstanding item was resolved satisfactory.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 27 February 2020
Resolved
Install backflow preventer on the saltwater to fresh water filtration piping.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 12 March 2020
Resolved 3 April 2020
Resolution: Received, reviewed, and accepted objective evidence from company proving the outstanding item was resolved satisfactory.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 5 December 2019
Resolved
The Starboard Engine Room door vent closure does not close properly. Make repairs to the satisfaction of attending MI.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 5 December 2019
Resolution: Photo's received and accepted to adequately clear deficiency.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 29 August 2019
Resolved
Install suitable exhaust lagging IWO MDE exhaust side shell penitrations.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 September 2019
Resolved 5 December 2019
Resolution: Lagging has been installed and is acceptable.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificate for medical first aid
Issued 29 August 2019
Resolved
Provide CPR first aid cards.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 September 2019
Resolved 23 September 2019
Resolution: Received, reviewed, and accepted documentation satisfying the requirement.
02 - Structural Conditions › N/A - No Subsystem › Stability/strength/loading information and instruments
Issued 12 March 2019
Resolved
Vessel has not completed a new deadweight survey as required by MSC letter dated September 13,2018 (serial: H2-1803524) and MSC Technical Note 4-95. The new survey is required due to an aggregate weight change in excess of 2%. According to MSC letter dated February 20,2007 (serial: H2-0700482), M/V NEUSE had receive alterations in 2007 amounting to an aggregate weight change of 1.02%. This previous change along with the voith unit soft patch installations, deck wear plate modifications, and other items completed since 2007 exceeds the 2% threshold. Provide new calculations.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 April 2019
Resolved 10 July 2020
Resolution: MSC issued new stability letter P012543 Serial H2-2002388.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 13 August 2018
Resolved
The vessel is currently Not broadcasting (1) IMO number.
Condition: Invalid
Action required: 705 - Other - as specified
Due 13 September 2018
Resolved 5 March 2019
Resolution: Vessel was properly broadcasting Official Number and MMSI number.
Fire Fighting › Ventilation Systems › Ducts
Issued 2 May 2018
Resolved
EDG space vent closures broken spring and will not close 100%.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 May 2018
Resolved 4 May 2018
Resolution: Replaced spring and greased.
Stability › Watertight Integrity › Weathertight Enclosure
Issued 2 May 2018
Resolved
B-end escape hatch dog cracked. Yard period in June conduct repairs.
Action required: 705 - Other - as specified
Due 30 June 2018
Resolved 5 March 2019
Resolution: Completed repairs during credit dry dock.
Stability › Watertight Integrity › Weathertight Enclosure
Issued 2 May 2018
Resolved
A-end escape hatch leaking
Action required: 705 - Other - as specified
Due 9 May 2018
Resolved 4 May 2018
Resolution: Replaced gsk and tested all SAT.
Lifesaving › Rigid Liferafts › Weak Link
Issued 2 May 2018
Resolved
Liferaft straps deteriorated on three rafts.
Action required: 705 - Other - as specified
Due 9 May 2018
Resolved 4 May 2018
Resolution: Replaced all 5 straps on life rafts.
Fire Fighting › Portable CO2 Fire Extinguisher › Condition
Issued 2 May 2018
Resolved
Ext #9 wasted horn clip
Action required: 705 - Other - as specified
Due 1 June 2018
Resolved 4 May 2018
Resolution: Replaced wasted clip.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 2 May 2018
Resolved
Harndrail B-end 01 deck stanchion cracked. Repair in Jane 2018 Yard
Action required: 705 - Other - as specified
Due 30 June 2018
Resolved 5 March 2019
Resolution: Completed repairs during credit dry dock.
Lifesaving › Rescue Boat Equipment › Rescue Quoit
Issued 2 May 2018
Resolved
Quoit ring deteriorated
Action required: 705 - Other - as specified
Due 1 June 2018
Resolved 4 May 2018
Resolution: Replaced Quoit
Engineering › Fuel Oil Storage/Transfer System › Valve
Issued 2 May 2018
Resolved
Fuel remote shutoff link-age temp repaired. replace in yard Jun 2018
Action required: 705 - Other - as specified
Due 30 June 2018
Resolved 5 March 2019
Resolution: Completed repairs during credit dry dock.
Communications › Alarms/Indicators › Engine RPM Gauge/Indicator
Issued 1 November 2017
Resolved
The #2 SSDG RPM gauge in not working; make the necessary repair and prove proper operation.
Due 15 November 2017
Resolved 7 November 2017
Resolution: Conducted operational test of equipment. All sat.
Communications › Alarms/Indicators › Lube Oil Low Pressure Alarm
Issued 9 August 2017
Resolved
#1 SSDG low L/O shutdown did not secure the engine; make repairs and prove proper operation.
Due 23 August 2017
Resolved 21 August 2017
Lifesaving › Lifebuoys › Serviceable
Issued 9 August 2017
Resolved
The life buoy on the "B" end is failing at the inner seam; replace the life buoy and ensure it is properly marked.
Due 23 August 2017
Resolved 21 August 2017
Electrical › Electrical Distribution System (service) › Wiring
Issued 9 August 2017
Resolved
Properly terminate the dead end wires in the #2 SSDG control panel and the EDG control panel.
Due 23 August 2017
Resolved 21 August 2017
Fire Fighting › Ventilation Systems › Ventilation Fire Dampers
Issued 9 August 2017
Resolved
Ventilation closure IWO the emergency generator compartment is not closing as designed; repair as necessary and prove proper operation.
Due 23 August 2017
Resolved 21 August 2017
Electrical › Electrical Distribution System (service) › Junction Box
Issued 9 November 2016
Resolved
Provide a cover for the junction box under the "A" end console on the bridge.
Action required: 705 - Other - as specified
Due 30 November 2016
Resolved 1 December 2016
Communications › Alarms/Indicators › Lube Oil Low Pressure Alarm
Issued 9 November 2016
Resolved
The loss of lube oil pressure shut down for the "A" end main engine did not function as designed, make the necessary repairs.
Action required: 705 - Other - as specified
Due 30 November 2016
Resolved 1 December 2016
Electrical › Electrical Distribution System (service) › Distribution Panel Bus
Issued 9 November 2016
Resolved
The breaker panel index card in the storage room located within the passenger accommodation space is not properly labeled with amperages; make the necessary corrections.
Action required: 705 - Other - as specified
Due 30 November 2016
Resolved 1 December 2016
Engineering › Fuel Oil Service System › Hose
Issued 9 November 2016
Resolved
Provide approved type hose (SAE J-1942) for the following machinery; (1) on the emergency generator, (1)on the "A" end main engine, (1) on the "B" end main engine, and (3)on the "B" end generator.
Action required: 705 - Other - as specified
Due 30 November 2016
Resolved 1 December 2016