Records from 1982 to 1992. Most recent: inspection, 2 July 1992.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 11
2 July 1992
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 956236
25 September 1991
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 674275
20 August 1991
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 940702
9 August 1990
COI Inspection · Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 900865
27 April 1989
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1212057
13 December 1988
COI Inspection · Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1033891
9 April 1987
Re-Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1009583
19 December 1985
Deficiency Check
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1293903
12 December 1985
COI Inspection · Credit Drydock
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1294073
1 November 1983
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 972350
2 December 1982
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 971368
Fire Fighting
Issued 20 August 1991
Resolved
INSTALL PROPER GUARD AROUND ROTATING PARTS OF FIRE PUMP ON STBD EMGINE.
Condition: Unknown
Due 4 September 1991
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Engineering
Issued 9 August 1990
Resolved
INSTALL PROPERLY OPERATING EMERGENCY ENGINE SHUT-OFF FROM BRIDGE.
Condition: Unknown
Due 9 August 1990
Resolved 9 August 1990
Construction/Loadline
Issued 9 August 1990
Resolved
REPAIR TWO CRACKS IN PORT WINDSHIELD.
Condition: Unknown
Due 9 August 1990
Resolved 9 August 1990
Engineering
Issued 9 August 1990
Resolved
INSURE PROPER OPERATION OF EMERGENCY FUEL SHUT-OFF, AND LABEL IT PROPERLY.
Condition: Unknown
Due 9 August 1990
Resolved 9 August 1990
Construction/Loadline
Issued 13 December 1988
Resolved
MAKE ALL BULKHEAD PENETRATIONS IN TRANSVERSE BULKHEADS WATERTIGHT IAW 46CFR 171.114.
Condition: Unknown
Due 13 December 1988
Resolved 13 December 1988
Documentation
Issued 13 December 1988
Resolved
PROVIDE PROOF OF CURRENT DOCUMENTATION IAW 46 CFR SUBCHAPTER G.
Condition: Unknown
Due 13 December 1988
Resolved 13 December 1988
Construction/Loadline
Issued 13 December 1988
Resolved
MAKE REPAIRS TO HOLE AT DECK/TRANSOM JUNCTION STARBOARD SIDE(1/4" HOLE). IAW 46 CFR 176.25-5
Condition: Unknown
Due 13 December 1988
Resolved 13 December 1988
Engineering
Issued 12 December 1985
Resolved
STENCIL EMERGENCY FUEL SHUT OFF VALVE.
Condition: Unknown
Due 12 December 1985
Resolved 12 December 1985
Construction/Loadline
Issued 12 December 1985
Resolved
REPAIR OR RENEW DOORS TO ACCOMMODATION SPACE.
Condition: Unknown
Due 12 December 1985
Resolved 12 December 1985
Unknown
Issued 12 December 1985
Resolved
REMOVE MODIFICATION EQUIPMENT FROM PASSENGER SPACE.
Condition: Unknown
Due 12 December 1985
Resolved 12 December 1985
Electrical
Issued 12 December 1985
Resolved
PROVIDE COVER FOR ELECTRICAL DISTRIBUTION PANEL IN ENGINE ROOM.
Condition: Unknown
Due 12 December 1985
Resolved 12 December 1985
Electrical
Issued 12 December 1985
Resolved
PROVIDE DIRECTORY FOR CIRCUITS IN ENGINE ROOM ELECTRICAL DISTRIBUTION PANEL.
Condition: Unknown
Due 12 December 1985
Resolved 12 December 1985
Unknown
Issued 12 December 1985
Resolved
INSTALL FIXED SEATING ON BOARD VESSEL.
Condition: Unknown
Due 12 December 1985
Resolved 12 December 1985
Fire Fighting
Issued 12 December 1985
Resolved
PROVIDE AND INSTALL FIRE EXTINGUISHER BRACKETS FOR ALL FIRE EXTINGUISHERS.
Condition: Unknown
Due 12 December 1985
Resolved 12 December 1985