MAURY USCG vessel records Sign in
← All vessels

DOLPHIN WATERS

DOLPHIN WATERS is a 1997 passenger vessel (inspected). The Coast Guard has recorded 47 inspections since 1997, most recently in April 2026, along with 72 deficiencies and 2 casualty investigations between 2002 and 2017.

Records from 1997 to 2026. Most recent: inspection, 21 April 2026.

Built
1997
Last inspected
21 April 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDL9583
453855
Flag
UNITED STATES
368180380
Maury page id
psix-453855

Inspections, by type

…with no type recorded2
Years with a record 28 calendar years (1997–2026)
The 47 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)45.0 ft × 14.0 ft × 3.5 ft
Registered tonnagegross 11 / net 8
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderCORINTHIAN CATAMARANS INC · TARPON SPRINGS, FL, UNITED STATES · built 1997
Hull materialFRP (Fiberglass)
PropulsionGasoline Outboard
Hull shapeShip
Hull configurationTwin Hull
Hailing portSANIBEL ISLAND, FL
Trade endorsementsCoastwise, unrestricted, Recreational
DocumentationValid · issued 8 January 2026 · expires 31 January 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it8 - Simplified, Net Ton
11 - Simplified, Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDL9583MMSI 368180380 · active · compulsorily equipped · granted 2 February 2021, expires 2 February 2031
WCX3750MMSI not assigned · expired · compulsorily equipped · granted 3 April 1997, cancelled 3 June 2007 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 47

21 April 2026 Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 8340224
23 January 2025 COI Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 8067669
25 November 2024 Internal Structural Exam · Hull Examination
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 8040482
5 March 2024 Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7874225
1 May 2023 Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7678519
15 November 2022 Internal Structural Exam · Hull Examination
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7594129
13 October 2022 Administrative Inspection
Administrative · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7576608
26 April 2022 Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7438406
22 March 2021 Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7158320
24 November 2020 Drydock Exam · Internal Structural Exam · Administrative Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7097725
4 December 2019 Administrative Inspection · COI Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6866954
10 May 2019 Administrative Inspection · Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6680178
5 October 2018 Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6554546
9 May 2018 Annual Inspection · Administrative Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6402537
28 June 2017 Type not recorded
No type recorded · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6189434
14 June 2017 Administrative Inspection · Damage Survey
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6190315
11 May 2017 DAPI Audit · Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6143569
19 September 2016 Examination of Repairs · Hull Examination · Administrative Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 5993073
3 February 2016 DAPI Audit · Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 5800144
1 May 2014 DAPI Audit · Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 4826269
2 May 2012 Annual Inspection · Administrative Inspection · Deficiency Check · DAPI Audit
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 4295635
18 January 2011 Hull Examination · Administrative Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 3924154
28 January 2010 Deficiency Check · COI Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 3671687
6 May 2009 Deficiency Check · Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 3463005
21 January 2009 Deficiency Check · Hull Examination
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 3396762
7 May 2008 Administrative Inspection · Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 3189883
26 January 2007 Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2859711
17 January 2007 Hull Examination · Deficiency Check
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2856736
9 February 2006 Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2582160
8 February 2005 Deficiency Check · COI Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2292350
28 January 2005 Deficiency Check · Hull Examination
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2281106
13 February 2004 Deficiency Check
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2005924
6 February 2004 Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2001565
26 March 2003 Deficiency Check
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 1763681
10 March 2003 Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 1755772
13 February 2003 Deficiency Check · Hull Examination
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 1744013
26 June 2002 Damage Survey
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 1640566
26 June 2002 Type not recorded
No type recorded · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 1640603
15 February 2002 Re-Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 1488491
15 February 2001 Re-Inspection · Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1410483
4 May 2000 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 819394
16 February 2000 COI Inspection · Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1408473
23 September 1999 Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1397264
16 September 1998 Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1381373
14 April 1998 Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1424599
8 May 1997 Initial Certification · Plan Review "T" Boat
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1364225
21 March 1997 Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1120173

Deficiency record · 72

01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 1 May 2023 Resolved
Your vessel must undergo an annual inspection within the 03 months before or after each anniversary date. Vessel's annual inspection date was overdue on 15APR2023. Vessel is not to carry passengers until a satisfactory annual inspection is completed. 46 CFR 176.500(b)(1)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 1 May 2023
Resolved 1 May 2023
Resolution: Completed annual inspection.
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Radio (including exemption)
Issued 11 May 2022 Resolved
A vessel must comply with the applicable requirements for any radio installation by the FCC. The Safety Radio Certificate is expired. Vessel restricted to not more than 1000 feet from shore until rectified. 46 CFR 184.502
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 May 2022
Resolved 23 May 2022
Resolution: Safety Radio Certificate was found. Not available on initial inspection.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 11 May 2022 Resolved
Each vessel certificated to operate on a limited coastwise route within 03 miles of land in warm water must: have onboard an EPIRB. The EPIRB battery was expired. Restricted to Lakes, Bays and Sounds until rectified. 46 CFR 180.205(e)(3)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 May 2022
Resolved 23 May 2022
Resolution: New EPIRB installed.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 11 May 2022 Resolved
The monthly EPIRB test shall be logged or otherwise documented. No records of EPIRB testing could be provided. 46 CFR 185.728(c)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 May 2022
Resolved 23 May 2022
Resolution: EPIRB drill log created.
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Radio (including exemption)
Issued 11 May 2022 Resolved
A durable placard must be posted next to all radios with the emergency broadcast instructions and information. No placard was posted in way of the radio. 46 CFR 184.506
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 May 2022
Resolved 23 May 2022
Resolution: Radio placard posted.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 11 May 2022 Resolved
Remote fuel shutoff valves must be marked in clearly legible letters. Could not read the fuel shut off placards for either tank. 46 CFR 185.608
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 May 2022
Resolved 23 May 2022
Resolution: Placards posted.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 11 May 2022 Resolved
A vessel must have at least 03 2.5 gallon buckets with an attached lanyard and labeled “FIRE BUCKET.” None of the fire buckets were labeled. 46 CFR 181.610
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 May 2022
Resolved 23 May 2022
Resolution: Fire buckets labeled.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 11 May 2022 Resolved
A vessel on a Limited Coastwise route must carry 12 hand flares. 08 red hand flares were expired. 46 CFR 180.68
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 May 2022
Resolved 23 May 2022
Resolution: New flares onboard.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 11 May 2022 Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up to date charts, Coast Pilot, and Light List. None of the publications were onboard. 46 CFR 184.420
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 May 2022
Resolved 23 May 2022
Resolution: All publications onboard.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 11 May 2022 Resolved
Each vessel must be equipped with at least two operable portable battery flashlights. 01 flashlight did not function. 46 CFR 183.340
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 May 2022
Resolved 23 May 2022
Resolution: Flashlights working.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 26 April 2022 Resolved
Your vessel must undergo an annual inspection within the 03 months before or after each anniversary date. Vessel's annual inspection date was overdue on 15APR2022. Vessel is not to carry passengers until a satisfactory annual inspection is completed. 46 CFR 176.500(b)(1)
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 April 2022
Resolved 11 May 2022
Resolution: Completed inspection.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 22 March 2021 Resolved
Vessel does not have required amount of distress signals. only holds 8 distress signals, needs 12, provide proof of equipping vessel with required amount of distress signals.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 April 2021
Resolved 1 April 2021
Resolution: Correct amount of flares placed on board.
11 - Life Saving Appliances › N/A - No Subsystem › Radio life-saving appliances
Issued 22 March 2021 Resolved
Vessel EPIRB battery is expired, but working. Vessel must provide proof of equipping vessel with new EPIRB. Restricted to 3 NM from shore until vessel is equipped with new required EPIRB.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 April 2021
Resolved 1 April 2021
Resolution: New EPIRB was purchased and placed onboard.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 22 March 2021 Resolved
Vessel does not have two required operable portable lights. Equip vessel with a 2nd operable portable light.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 April 2021
Resolved 1 April 2021
Resolution: Second working flashlight was placed onboard.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 22 March 2021 Resolved
Vessel does not have up to date coast pilot or tide table on board. Provide proof of equipping vessel with up to date versions of coast pilot and tide table.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 April 2021
Resolved 1 April 2021
Resolution: Applicable excerpts of tide tables and coast pilot were placed onboard.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 12 May 2017 Resolved
Replace railing over ladder on bow meeting 46CFR177.900(g)(1)
Action required: 705 - Other - as specified
Due 26 May 2017
Resolved 15 June 2017
Resolution: Added proper railing.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 11 May 2017 Resolved
Replace railing over starboard ladder on bow meeting 46CFR177.900(g)(1)
Action required: 705 - Other - as specified
Due 26 May 2017
Resolved 15 June 2017
Resolution: Added railing on starboard ladder.
Fire Fighting › Fire Bucket › Lanyard
Issued 11 May 2017 Resolved
Place lanyards on all three fire buckets. (46CFR181.610)
Action required: 705 - Other - as specified
Due 26 May 2017
Resolved 15 June 2017
Resolution: Placed lanyards on all three buckets.
Construction/Loadline › Structures › Deck Plating
Issued 19 September 2016 Resolved
Repair portions of soft deck in bow area from 2 feet aft of the dock boxes to the bow of vessel by replacing with marine grade ply wood and laying new fiberglass. 46 CFR 176.610
Action required: 705 - Other - as specified
Resolved 17 November 2016
Resolution: repaired deck by laying new marine grade ply wood and laying new fiberglass over ply wood.
Construction/Loadline › Structures › Deck Plating
Issued 19 September 2016 Resolved
Replace two rotted deck beams that extend the entire breadth of the deck, directly below dock boxes on bow with two new beams. 46 CFR 176.610
Action required: 705 - Other - as specified
Resolved 17 November 2016
Resolution: replaced two beams with new ones across entire breadth of deck.
Construction/Loadline › Structures › Deck Plating
Issued 19 September 2016 Resolved
Lay new Non-skid in aft portion of vessel below canopy where awning is oveheard and old carpet was removed. 46 CFR 176.610
Action required: 705 - Other - as specified
Resolved 17 November 2016
Resolution: Laid new non in aft portion of deck below canopy with the West marine brand deck coating.
Navigation › Piloting/Steering › Marine Charts
Issued 3 February 2016 Resolved
O/O could not provide up to date charts and tidal/current tables for aresa of operation. Provide current/updated. 46 CFR 184.420
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 March 2016
Resolved 21 March 2016
Resolution: O/O provide up to dated Marine Chart & Tidal Current tables.
Documentation › Logs/Records › Logbook (official)
Issued 3 February 2016 Resolved
O/O could not provide a training log for vessels crew. Provide current training log for crew. 46 CFR 185.520/524
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 March 2016
Resolved 18 March 2016
Resolution: O/O provided a current training log for crew.
Pollution Prevention/Response › Prevention Equipment › Bilge Monitor
Issued 3 February 2016 Resolved
Bilge high level alarm visual light was inop when tested. Repair or replace bilge high level alarm. 46 CFR 182.530
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 March 2016
Resolution: O/O installed new bilge high level visual/audible alarm. All SAT
Accommodation/Occupational Safety › Washroom/Toilet › Toilet
Issued 3 February 2016 Resolved
Found raw water line to toilet was dry rotted & cracked. Replace with new.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 March 2016
Resolution: O/O replace raw water with new hose. All SAT
Construction/Loadline › Markings › Vessel Name/Home Port
Issued 3 February 2016 Resolved
Vessel name in not labeled on the stern of vessel. Label stern of vessel with name. 46 CFR 67.123
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 March 2016
Resolved 18 March 2016
Resolution: O/O posted vessel name on stern. All SAT
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 3 February 2016 Resolved
Vessels sewage tank does not have an overboard valve installed in line. Install valve in line and secure while w/in state waters or pumping out to facility. 33 CFR 159
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 3 March 2016
Resolved 11 April 2016
Resolution: O/O installed dishcharge valve in overboard line. All SAT
Construction/Loadline › Hull › Hull Plating
Issued 3 February 2016 Resolved
Both port and starboard main deck hull entrances have decayed decky & common cross member needs replacement approximately 4'on each side. Remove decking back to good wood. 46 CFR 176.610
Condition: Damaged By Earlier Event
Due 13 February 2017
Resolved 16 November 2016
Resolution: Replaced with new wood and reglassed into place.
Construction/Loadline › Hull › Longitudinal Frame
Issued 3 February 2016 Resolved
Forward bow where inspection port is located has decay inside hull. Deck area is spongy. Cut back deck area to good wood on main deck bow area & repair/replace cross member that is decayed. 46 CFR 176.610
Due 13 February 2017
Resolved 17 November 2016
Resolution: replaced decking with new wood.
Navigation › Piloting/Steering › Steering Magnetic Compass
Issued 3 February 2016 Resolved
Vessels compass light is inoperative. Repair/replace light and show proper operation of light. 46 CFR 184.402(c)
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 18 March 2016
Resolution: Compass light was repaired. SAT
Engineering › Fuel Oil Service System › Tank
Issued 1 May 2014 Resolved
Both vessels fuel tanks are missing fuel vent screens. Replace with new screens. 46 CFR 182.10-35
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 May 2014
Resolution: Vessel installed new vent screens on both fuel tank vents.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 2 May 2012 Resolved
Replace expired items in first aid kit IAW 46 CFR 184.710.
Action required: 705 - Other - as specified
Due 9 May 2012
Resolved 16 May 2012
Operations/Management › Drug and Alcohol Testing › MIS Submission
Issued 2 May 2012 Resolved
Provide a current copy of MIS report IAW 46 CFR 16.
Action required: 705 - Other - as specified
Due 9 May 2012
Resolved 9 May 2012
Lifesaving › Lifejacket/PFD (Type I) › Size
Issued 2 February 2010 Resolved
Separate child life jackets from adults
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 February 2010
Communications › Alarms/Indicators › Fire Alarm
Issued 2 February 2010 Resolved
Repair smoke detector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 February 2010
Communications › Alarms/Indicators › Bilge Alarm
Issued 2 February 2010 Resolved
Repair bilge high level alarms.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 February 2010
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 2 February 2010 Resolved
Repair portable lights.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 February 2010
Operations/Management › Drug and Alcohol Testing › Testing, Serious Marine Incident
Issued 2 February 2010 Resolved
Place serious marine test kit on vessel.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 February 2010
Personnel › Certificates/Documents/Licenses › License, Radio Officer
Issued 2 February 2010 Resolved
Fax copy of marine operator permit to MSD.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 February 2010
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 2 February 2010 Resolved
Place certificate of documentation on vessel.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 February 2010
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 28 January 2010 Resolved
Mount (1) fire extinguisher.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 February 2010
Communications › Radio Communications › EPIRB
Issued 6 May 2009 Resolved
Replace battery and hydro EPIRB
Due 10 May 2009
Resolved 7 May 2009
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 6 May 2009 Resolved
Replace items in first aid kit
Due 10 May 2009
Resolved 7 May 2009
Communications › Radio Communications › EPIRB
Issued 7 May 2008 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 705 - Other - as specified
Resolved 15 May 2008
Resolution: Cleared
Communications › Radio Communications › EPIRB
Issued 9 February 2006 Resolved
RENEW HYDROSTATIC RELEASE AND NOAA REGISTRATION FOR THE EPIRB.
Due 1 March 2006
Resolved 9 February 2006
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 9 February 2006 Resolved
PROVIDE RETROREFLECTIVE TAPE ON ORANGE RING BOUY AND HOOK UP LIFELINE AND LIGHT.
Due 1 March 2006
Resolved 15 February 2006
Documentation › Certificates/Documents › Cargo Ship Safety Radio Certificate
Issued 9 February 2006 Resolved
RENEW SAFTEY RADIO CERTIFICATE.
Due 1 March 2006
Resolved 9 February 2006
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Condition
Issued 9 February 2006 Resolved
DERUST AND COAT BOTH B-II PORTABLE FIRE EXTINGUISHER BASES.
Due 1 March 2006
Resolved 15 February 2006
Documentation › Logs/Records › Logbook (official)
Issued 8 February 2005 Resolved
Provide lifesaving maintenance log
Action required: 705 - Other - as specified
Due 8 March 2005
Resolved 14 February 2005
Communications › Radio Communications › EPIRB
Issued 8 February 2005 Resolved
Replace expired EPIRB battery.
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 February 2005
Resolved 8 February 2005
Resolution: New battery replaced before inspection was completed
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 8 February 2005 Resolved
Replace 60ft of buoyant line for life ring
Action required: 705 - Other - as specified
Due 8 March 2005
Resolved 14 February 2005
Fire Fighting › Portable CO2 Fire Extinguisher › Condition
Issued 8 February 2005 Resolved
Replace two (2) B-II extinguishers
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 February 2005
Resolved 8 February 2005
Resolution: NEW
Engineering › Fuel Oil Service System › Tank
Issued 8 February 2005 Resolved
Provide 30x30 fuel screen for fuel tank vent.
Action required: 705 - Other - as specified
Due 15 February 2005
Resolved 14 February 2005
Construction/Loadline › Hull › Keel
Issued 26 January 2005 Resolved
Grind out gouge on port side hull, fwd bow. Repair using West System Epoxy or equivalent. Scarf repair out to proper ration IAW good marine practice.
Action required: 705 - Other - as specified
Due 4 February 2005
Resolved 28 January 2005
Construction/Loadline › Hull › Keel
Issued 26 January 2005 Resolved
Re-new to original worn layers of chopped strand mat (2 layers) from beaching ops.
Action required: 705 - Other - as specified
Due 4 February 2005
Resolved 28 January 2005
Construction/Loadline › Hull › Keel
Issued 26 January 2005 Resolved
Provide wear indicating/chafing FRP as follows: red, yellow, green.
Action required: 705 - Other - as specified
Due 4 February 2005
Resolved 28 January 2005
Communications › Radio Communications
Issued 6 February 2004 Resolved
hydrostatic release needs replacement LEGACY COMPONENT DESC: EPIRB
Action required: 705 - Other - as specified
Due 14 February 2004
Resolved 13 February 2004
Resolution: New hydro installed.
Fire Fighting
Issued 6 February 2004 Resolved
Provide UL approved smoke detectors in both hulls.
Action required: 705 - Other - as specified
Due 14 February 2004
Resolved 13 February 2004
Engineering › Fuel Oil Storage/Transfer System
Issued 10 March 2003 Resolved
PROVIDE 30 x 30 MESH SCREEN FOR FUEL TANK VENTS. PORT AND STBD. LEGACY COMPONENT DESC: Vent Pipe
Action required: 705 - Other - as specified
Due 24 March 2003
Resolved 26 March 2003
Accommodation/Occupational Safety
Issued 10 March 2003 Resolved
PROVIDE 3" NO SMOKING SIGNS.
Action required: 705 - Other - as specified
Due 24 March 2003
Resolved 26 March 2003
Engineering › Fuel Oil Service System
Issued 10 March 2003 Resolved
PROVIDE QUICK DISCONNECT FITTING FOR JETTISONABLE FUEL TANKS IAW SUBMITTED AND APPROVED PLANS. LEGACY COMPONENT DESC: Hose
Action required: 705 - Other - as specified
Due 24 March 2003
Resolved 26 March 2003
Resolution: PLANS WHICH DOLPHIN WATERS SISTERED FROM WERE NOT CLEAR ON WHAT EXACTLY WAS USED FOR QUICK DISCONNECT, HOWEVER PLANS WERE APPROVED BY TAMMS. DOLPHIN WATERS DISCONNECT SETUP WILL PROVIDE THE INTENT OF WHAT IS TRYING TO BE ACCOMPLISHED.
Accommodation/Occupational Safety › Medical/First Aid
Issued 10 March 2003 Resolved
PROVIDE CG APPROVED FIRST AID KIT OR PROVIDE CONTENT LIST FOR EXISTING KIT. LEGACY COMPONENT DESC: Medicine Chest
Action required: 705 - Other - as specified
Due 24 March 2003
Resolved 26 March 2003
Construction/Loadline › Hull
Issued 13 February 2003 Resolved
REPAIR 1/8th INCH GOUGE ON STBD FORWARD HULL LEGACY COMPONENT DESC: Bottom Plating
Action required: 705 - Other - as specified
Due 28 February 2003
Resolved 20 February 2003
Construction/Loadline › Hull
Issued 13 February 2003 Resolved
RE-BUILD WORN AREA OF CHOP STRAND MAT FROM VSL BEACHING BOTH PORT AND STBD HULLS LEGACY COMPONENT DESC: Bottom Plating
Action required: 705 - Other - as specified
Due 28 February 2003
Resolved 20 February 2003
Construction/Loadline › Hull
Issued 13 February 2003 Resolved
REPAIR AREA OF DAMAGED GEL COAT PORT AFT CORNER. LEGACY COMPONENT DESC: Side Shell
Action required: 705 - Other - as specified
Due 28 February 2003
Resolved 20 February 2003
Construction/Loadline › Structures
Issued 13 February 2003 Resolved
RE-TAB STBD HULL DECK SUPPORT TRANSVERSE BEAM, 6TH FROM STERN. LEGACY COMPONENT DESC: Transverse Bulkhead
Action required: 705 - Other - as specified
Due 28 February 2003
Resolved 20 February 2003
Construction/Loadline › Hull
Issued 13 February 2003 Resolved
REPAIR FRACTURE UNDERNEATH PORT MOTOR MOUNT. LEGACY COMPONENT DESC: Bracket
Action required: 705 - Other - as specified
Due 28 February 2003
Resolved 18 February 2003
Engineering › Gasoline Engine (propulsion)
Issued 15 February 2001 Resolved
PROVIDE WRITTEN PROPOSAL PRIOR TO APRIL 15, 2002 TO BRING FUEL TANK ARRANGEMENT INTO COMPLIANCE WITH 46 CFR 177.410. ARRANGEMENT TO BE COMPLETED AT NEXT SCHEDULED DRYDOCKING. LEGACY COMPONENT DESC: Fuel Tank Arrangement
Condition: Unknown
Action required: 705 - Other - as specified
Due 15 February 2003
Resolved 18 February 2003
Resolution: WITNESSED INSTALLATION OF TANK ASSEMBLY IAW PLANS APPROVED BY TAMMS.
Documentation
Issued 16 February 2000 Resolved
PROVIDE PROOF OF DRUG TESTING PROGRAM.
Condition: Unknown
Due 16 February 2000
Resolved 16 February 2000
Lifesaving
Issued 23 September 1999 Resolved
PROVIDE AND POST PFD DONNING PLACARDS.
Condition: Unknown
Due 26 October 1999
Resolved 26 October 1999
Documentation
Issued 23 September 1999 Resolved
PROVIDE LOGBOOK FOR VESSEL.
Condition: Unknown
Due 26 October 1999
Resolved 26 October 1999
Construction/Loadline
Issued 23 September 1999 Resolved
INSTALL HIGH WATER ALARM STARBOARD SIDE AFT COMPARTMENT.
Condition: Unknown
Due 26 October 1999
Resolved 26 October 1999

Casualty record · 2

26 June 2002Routine · role: Involved in a Marine Casualty · 1 injured · activity 1640603
28 June 2017Routine · role: Involved in a Marine Casualty · 1 injured · activity 6189434
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record