Records from 1997 to 2025. Most recent: inspection, 6 June 2025.
Inspection history · 46
6 June 2025
Annual Inspection · Internal Structural Exam · Deficiency Check
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8153544
28 August 2024
Periodic Inspection · Deficiency Check · MTSA Verification
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7990855
14 March 2024
Administrative Inspection
Administrative · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7879074
6 March 2023
Annual Inspection · MTSA Verification · Deficiency Check
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7646553
22 August 2022
Internal Structural Exam · Cargo Tank Internal · Drydock Exam
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7540527
16 August 2021
COI Inspection · Administrative Inspection · MTSA Verification
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7288598
3 November 2020
MTSA Verification · Annual Inspection · Administrative Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7088715
28 April 2020
Internal Structural Exam · Administrative Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6949115
12 November 2019
Periodic Inspection · MTSA Verification · Administrative Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6853879
20 September 2018
MTSA Verification · Administrative Inspection · Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6553877
31 July 2017
Drydock Exam · Annual Inspection · MTSA Verification · Cargo Tank Internal · Hull Examination · Administrative Inspection · Internal Structural Exam
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6226242
26 July 2016
COI Inspection · Deficiency Check · Examination of Repairs · MTSA Verification
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 5953190
30 November 2015
MTSA Verification · Annual Inspection · Administrative Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 5775285
30 April 2015
Internal Structural Exam
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 5113783
10 November 2014
MTSA Verification · Annual Inspection · Administrative Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 5020963
30 November 2013
Annual Inspection · Administrative Inspection · MTSA Verification
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 4770507
14 November 2012
Administrative Inspection · MTSA Verification · Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 4486822
30 April 2012
Internal Structural Exam · Hull Examination · Administrative Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 4313728
2 August 2011
Examination of Repairs · Administrative Inspection · COI Inspection · MTSA Verification
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 4102744
30 November 2010
Annual Inspection · Examination of Repairs · MTSA Verification
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 3863080
28 March 2010
Internal Structural Exam
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 3727692
25 January 2010
Administrative Inspection
Administrative · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 3669293
31 March 2009
Internal Structural Exam
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 3644048
5 November 2008
Annual Inspection · MTSA Verification
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 3353879
30 November 2007
Administrative Inspection · MTSA Verification · Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 3107358
4 April 2007
Hull Examination · Cargo Tank Internal · Administrative Inspection · Internal Structural Exam
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 2876478
15 July 2006
COI Inspection · MTSA Verification
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 2758153
12 October 2005
Annual Inspection · MTSA Verification
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 2516204
31 March 2005
Internal Structural Exam
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 2323639
26 August 2004
Annual Inspection · MTSA Verification
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 2190224
28 April 2004
Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 2054526
30 January 2004
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1999755
6 January 2004
Administrative Inspection
Administrative · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1976915
17 September 2003
Annual Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1906855
10 February 2003
Administrative Inspection
Administrative · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1742489
18 April 2002
Annual Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1606347
9 April 2002
Internal Structural Exam · Hull Examination
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1602706
15 July 2001
COI Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1456990
30 June 2000
Re-Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1445651
29 March 2000
Hull Examination
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1379005
8 September 1999
Deficiency Check
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 783727
13 August 1999
Deficiency Check
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1113238
13 July 1999
COI Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1404797
12 May 1999
Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 477878
1 August 1997
Initial Certification · Hull Examination
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1096599
5 May 1997
Deficiency Check
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1096991
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 6 June 2025
Resolved
The average thickness for longitudinal strength plating must be at least as follows: Weather deck: 75 percent of Rule thickness.
Deck of starboard bow has hole into the void space from wasted metal, thickness is at 0 percent.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 July 2025
Resolution: Witnessed NDT of all inserts. All satisfactory.
14 - Pollution Prevention › 141 - MARPOL Annex I › Control of discharge
Issued 28 August 2024
Resolved
A mechanical means of closing each drain and scupper in the container or enclosed deck area required by this section.
Had wooden plugs installed in containment coaming.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 September 2024
Resolved 27 February 2025
Resolution: Recieved photographic evidence that plugs were replaced
14 - Pollution Prevention › 141 - MARPOL Annex I › Other (MARPOL Annex I)
Issued 28 August 2024
Resolved
A ship, except a ship of less than 26 feet in length, must have a placard of at least 5 by 8 inches, made of durable material fixed in a conspicuous place stating the following:
Discharge of Oil Prohibited
Missing oil discharge placard.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 September 2024
Resolved 27 February 2025
Resolution: revieved photographic evidence that placard was installed.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo transfer - Tankers
Issued 6 March 2023
Resolved
Each valve must close with a right-hand (clockwise) motion of the handwheel or operating lever as seen by one facing the end of the valve stem. Each gate, globe, and angle valve must generally be of the rising-stem type. Vessels cargo valves were faulty: 01 was broken and 02 were inop. Must fix prior to carrying cargo.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 June 2023
Resolution: fixed inoperable valves
01 - Certificates & Documentation › 013 - Documents › Cargo information
Issued 6 March 2023
Resolved
Annually, at least one of the exercises listed in § 155.1060(a) (2) and (4) must be unannounced. Vessel never conducted annual Exercise of plan.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 March 2023
Resolved 12 June 2023
Resolution: annual exercise completed
01 - Certificates & Documentation › 013 - Documents › Booklet for bulk cargo loading/unloading/stowage
Issued 6 March 2023
Resolved
The operator of a vessel with a capacity of 250 or more barrels of oil, hazardous material, or liquefied gas as regulated in Table 4 of 46 CFR part 154 shall provide transfer procedures that meet the requirements of this part and part 156 of this chapter for transferring. Vessel was missing barge transfer procedures.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 March 2023
Resolved 12 June 2023
Resolution: provided transfer procedures.
09 - Working and Living Conditions › 092 - Working Conditions › Warning notices
Issued 6 March 2023
Resolved
All cargo tank hatches must be clearly marked in not less than three inch lettering “Danger - Keep Out,” and all hatch covers must be closed and dogged down in such a way that the hatch cannot be opened by the use of bare hands alone.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 March 2023
Resolved 17 April 2023
Resolution: Cargo tanks marked
14 - Pollution Prevention › 141 - MARPOL Annex I › Control of discharge
Issued 16 August 2021
Resolved
A tank vessel with a capacity of 250 barrels that is carrying oil or hazardous material as cargo must have a mechanical means of closing each drain and scupper in the container or enclosed deck area required by this section.
Missing plugs for deck containment
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 20 October 2021
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 16 August 2021
Resolved
A vessel or object other than those referred to in parargraph (g) of this Rule being towed shall exhibit: sidelights, sternlight.
Nav lights were missing from barge.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 20 October 2021
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 16 August 2021
Resolved
The vessel's name or number shall be so displayed at the highest part of the vessel's hull or permanent structure that the name or number can be seen from either side.
Name of barge was incorrect - should be "043" as stated on vessel's COI.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 20 October 2021
Construction/Loadline › Hull › Hull Plating
Issued 30 April 2015
Resolved
Identified hole in deck plate over center aft void and over #1 port Cargo hold. Crop and renew to good metal.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 January 2016
Resolved 28 July 2016
Resolution: Completed repairs.
Documentation › Markings/Placards › Warning Signs
Issued 10 November 2014
Resolved
Warning signs for security and transfer ops were worn; Restenciled.
Condition: Improper/Lack of Maintenance
Due 30 November 2014
Resolved 30 November 2014
Deck/Cargo › Holds/Tanks › Valve, Pressure Vacuum Relief
Issued 2 August 2011
Resolved
Renew holed screen on port aft P/V valve.
Condition: Improper/Lack of Maintenance
Due 31 August 2011
Resolved 22 August 2011
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Flame Screens
Issued 2 August 2011
Resolved
Found flames screens holed; required replacement.
Condition: Improper Installation
Due 31 August 2011
Resolved 22 August 2011
Construction/Loadline › Hull › Hull Plating
Issued 4 April 2007
Resolved
Found slotted hole in way of starboard stern void shell plate due to wastage around old insert. Cropped and renewed with 43" x 23" x 3/8" ABS approved steel .
Condition: Unknown
Due 4 April 2007
Resolved 4 April 2007
Deck/Cargo › Vapor Control Systems › Vessel Vapor Overpressure/Vacuum Protection
Issued 15 July 2006
Resolved
Screens in P/V valves were wasted; replaced.
Condition: Improper/Lack of Maintenance
Due 15 July 2006
Resolved 15 July 2006
Deck/Cargo › Vapor Control Systems › Flame Screens
Issued 12 October 2005
Resolved
Replace Flame screen on port forward tank vent.
Condition: Damaged By Earlier Event
Due 24 October 2005
Resolved 17 October 2005
Resolution: all sat.
Electrical › Electric Supply System (service) › Cable
Issued 12 October 2005
Resolved
Remove dead end wires on deck.
Condition: Improper Installation
Due 24 October 2005
Resolved 17 October 2005
Resolution: all sat.
Pollution Prevention/Response › Prevention Equipment › Drains/Scuppers (means of closure)
Issued 12 October 2005
Resolved
Replace wasted and corroded plugs in containment bins
Condition: Unknown
Due 24 October 2005
Resolved 17 October 2005
Resolution: all sat.
Deck/Cargo › Vapor Control Systems › Flame Screens
Issued 12 October 2005
Resolved
clean ullage cap flame screen. flame screen covered in fuel oil
Condition: Improper/Lack of Maintenance
Due 24 October 2005
Resolved 17 October 2005
Resolution: all sat.
Construction/Loadline › Hull
Issued 19 March 2002
Resolved
Fracture on stbd inboard section of skeg LEGACY COMPONENT DESC: skeg
Condition: Unknown
Due 19 March 2002
Resolved 19 March 2002
Resolution: Fracture cropped and renewed to good metal.
Documentation
Issued 13 July 1999
Resolved
PROVIDE CGHQ APPROVED VESSEL RESPONSE PLAN.
Condition: Unknown
Due 13 July 1999
Resolved 13 July 1999
Documentation
Issued 1 August 1997
Resolved
PROVIDE CARGO PIPING, ELECTRICAL AND MACHINERY PLANS. DO NOT USE VESSEL'S PUMPS TO TRANSFER CARGO UNTIL PLANS HAVE BEEN APPROVED BY USCG.
Condition: Unknown
Due 5 August 1997
Resolved 5 August 1997
Construction/Loadline
Issued 1 August 1997
Resolved
VESSEL MUST BE DRYDOCKED FOR USCG INSPECTION. VESSEL'S ROUTE RESTRICTED TO ONE TRANSIT PER WEEK, DIRECTLY BETWEEN DETYENS MAIN YARD AND DETYENS WANDO YARD IN MT. PLEASANT, DURING DAYLIGHT HOURS ONLY UNTIL CORRECTED._x001C_
Condition: Unknown
Due 1 August 1997
Resolved 1 August 1997