← All vessels
ARISTEA M
ARISTEA M is a 1997 freight ship. The Coast Guard has recorded 16 inspections since 1998, most recently in May 2012, along with 8 deficiencies and 3 operational controls.
Records from 1998 to 2012. Most recent: inspection, 27 May 2012.
- Built
- 1997
- Last inspected
- 27 May 2012
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 8 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9126302 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
H8BZ
453896
Flag
MALTA
—
Maury page id
psix-453896
Inspections, by type
The 16 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 14 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.
Documentation record
Tonnage as PSIX records it26239 - Convention (Subpart B), Gross Ton
15151 - Convention (Subpart B), Net Ton
45584 - Dead Weight, Ton
53731 - Displacement, Ton
15151 - Convention (Subpart B), Net Ton
45584 - Dead Weight, Ton
53731 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 16
27 May 2012
PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4311576
14 May 2012
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4311553
20 April 2009
Damage Survey
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3445737
16 April 2009
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3444830
16 April 2009
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3444836
16 April 2009
ISPS I Exam · COE-Offshore
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3454445
17 August 2008
Type not recorded
No type recorded · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 3302930
3 June 2008
Ballast Water Examination · Deficiency Check · PII Safety Exam · ISPS II Exam
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 3227166
29 April 2005
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2345522
14 April 2005
PII Safety Exam · ISPS II Exam
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2333557
22 March 2004
Annual Inspection · Ballast Water Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2028832
19 June 2003
Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1821794
22 January 2003
MARPOL Annex I Examination · Ballast Water Examination · Annual Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1734388
11 January 2000
Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 273268
16 October 1998
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 421229
13 October 1998
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 420986
Deficiency record · 8
Documentation › Logs/Records › Garbage Recordkeeping
Issued 27 May 2012
Resolved
2120-Training-Upon joining the vessel, personnel shall be familiarized and trained in accordance with garbage management plan. PSCO observed no garbage training or familiarization for ship’s crew. Provide corrective action plan from company with concurrence from administration for training and familiarization.
-MARPOL 73/78 Annex V/9
Documentation › Logs/Records › Transfer Equipment Test/Inspection Records
Issued 27 May 2012
Resolved
0899-Test-Each bunker line transfer pipe must be tested annually under liquid pressure at least 1.5 times the maximum allowable working pressure. Vessel conducted annual test however, air was used as a medium. 33CFR156.170
Engineering › Diesel Engine (propulsion-direct drive) › Cylinder
Issued 16 April 2009
Resolved
16APRIL2009 Recieved notification that vessel had a failure of the #2 piston in the main diesel engine while enroute to the Port of Corpus Christi. Vessel restricted to daylight transit only with tug. Issued COTP Order 046-09.
Electrical › Electric Generation Source (service) › Grounding Conductor
Issued 14 April 2005
Resolved
The vessel did not have certificates showing that the electrical matting used on board met the SOLAS requirements of II-1 Reg. 40,45-1.3 and 45-2.
Operations/Management › Ballast Water Managment › Training
Issued 14 April 2005
Resolved
The ballast water management plan was missing information in sections 4, 7 and 8.
Documentation › Logs/Records › Garbage Recordkeeping
Issued 14 April 2005
Resolved
The [name withheld] has not been recording the burning of oil rags in the ship's incinerator.
Navigation › Collision/Grounding Avoidance
Issued 22 March 2004
Resolved
Vessel secondary radar observed not working properly. Technicians report to be faxed to Activities Baltimore prior to departure. LEGACY COMPONENT DESC: Radar
Engineering
Issued 13 October 1998
Resolved
PROPERLY DEMONSTRATE OILY WATER SEPARATOR, CONDUCT MAINTENANCE OF COALESCER'S, AND SERVICE ALARM PANEL. NO OVERBOARD DISCHARGE THROUGH OILY WATER SEPARATOR UNTIL OBSERVED BY USCG INSPECTOR AT MSO NEW ORLEANS LOUISIANA. MARPOL 73/78 I/16
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.