Records from 1986 to 2009. Most recent: inspection, 21 June 2009.
Inspection history · 37
21 June 2009
Administrative Inspection
Administrative · Commandant (CG-CVC) · Activity 3509872
30 March 2009
MARPOL Annex I Examination
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3442971
16 January 2008
MARPOL Annex I Examination
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3131491
9 June 2006
MARPOL Annex I Examination
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2674935
28 June 2005
MARPOL Annex I Examination
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2406775
26 March 2004
Administrative Inspection
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2031912
27 June 2002
Administrative Inspection
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1640136
10 May 2002
Annual Inspection · Hull Examination · Internal Structural Exam
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1615522
22 February 2002
Administrative Inspection
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1488540
20 February 2001
COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1373368
15 May 2000
Examination of Repairs
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1365768
15 February 2000
Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1408449
16 March 1999
Deficiency Check · COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1442798
23 February 1998
Re-Inspection · Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1455560
8 May 1997
Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1100631
17 March 1997
Hull Examination · COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1357880
21 January 1997
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1099706
11 March 1996
Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1400283
9 June 1995
Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 876982
14 February 1995
COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1425549
24 February 1994
Hull Examination · Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1410918
25 February 1993
Deficiency Check · COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1407112
27 May 1992
Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 958114
12 March 1992
Examination of Repairs
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1354123
22 January 1992
Hull Examination · Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1436679
12 March 1991
Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 907465
27 February 1991
COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1234316
28 February 1990
Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 914840
23 February 1989
COI Inspection · Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1193982
22 April 1988
COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1344324
20 April 1988
Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1033064
21 April 1987
Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1008794
26 January 1987
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1318452
21 November 1986
Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1020413
16 October 1986
Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1015815
10 April 1986
Credit Drydock · COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1306208
7 February 1986
Damage Survey
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 993020
Documentation › Safety/Response Plans/Programs › SOPEP
Issued 15 May 2009
No resolution recorded
All references to Regulation 26 of Annex I in the SOPEP must be updated to reference Regulation 37 of Annex I.
Due 15 June 2009 — due date passed with no resolution recorded
Deck/Cargo › Cargo Transfer (solid)
Issued 13 June 2002
Resolved
Provide CG approved dwg's for cargo pump comp.air sys. (air comp. w/ diesel prime mover, 2 ind. fuel tanks, & piping sys), on the upper level (top of house). All comments pertaining to approval must be addressed to satisfaction of the attending marine insp. No operation permitted until cleared.
Due 13 August 2002
Resolved 21 November 2002
Resolution: Vessel no longer in certificated service.
Electrical › Electrical Distribution System (service)
Issued 13 June 2002
Resolved
Provide CG approved dwg's for the new (additional) shore tie bus installed May-June 2002. All comments pertaining to the approval must be addressed to the satisfaction of the attending marine inspector before this system can be operated. LEGACY COMPONENT DESC: Shore Connection Box
Due 13 August 2002
Resolved 21 November 2002
Resolution: Vessel no longer in certificated service.
Deck/Cargo › Cargo Transfer (solid)
Issued 13 June 2002
Resolved
Provide CG approved dwg's forthe new comp. air sys (for pump seals) installed May-June 2002. All comments pertaining to the app of dwg's must be addressed & operational tests conducted to satisfaction of the attending marine inspector. The system shall not be operated until this req. is cleared.
Due 13 August 2002
Resolved 21 November 2002
Resolution: Vessel no longer in certificated service.
Fire Fighting › Portable Dry Chemical Fire Extinguisher
Issued 13 June 2002
Resolved
Provide 1 additional B-II portable fire extinguisher to be mounted in way of new diesel-driven compressor on the upper deck. No fuel can be loaded in the 2 independent tanks, nor can the diesel prime mover be operated until this is cleared. LEGACY COMPONENT DESC: Number
Due 13 August 2002
Resolved 21 November 2002
Resolution: Vessel no longer in certificated service.
Engineering › Diesel Engine (auxiliary)
Issued 13 June 2002
Resolved
Provide racor filter installed in the enclosure for the diesel-driven compressor with a steel flame impingement shied and solid metallic drain plug. The metallic plug may be substituted with a solid body valve fitted with a plug or cap. LEGACY COMPONENT DESC: Fuel filter
Condition: Improper Installation
Due 13 August 2002
Resolved 21 November 2002
Resolution: Vessel no longer in certificated service.
Construction/Loadline › Hull
Issued 13 June 2002
Resolved
Have the loose scale and dry cement in the port and starboard aft rake and in #5 void (dry cement pump room) removed from the vessel and properly disposed of.
Condition: Improper/Lack of Maintenance
Due 13 June 2003
Resolved 21 November 2002
Resolution: Vessel no longer in certificated service.
Construction/Loadline
Issued 16 March 1999
Resolved
CROP AND RENEW DAMAGED AREA, STBD SIDE, SIDE LONGS 1-3 FR #7.
Condition: Unknown
Due 16 April 1999
Resolved 7 April 1999
Construction/Loadline
Issued 16 March 1999
Resolved
REPAIR FRACTURE, STBD SIDE, SIDE LONG 7 FR #5 1/2.
Condition: Unknown
Due 16 April 1999
Resolved 7 April 1999
Construction/Loadline
Issued 16 March 1999
Resolved
REPAIR FRACTURE, STBD SIDE, BOTTOM LONG 9, FR #3.
Condition: Unknown
Due 16 April 1999
Resolved 7 April 1999
Construction/Loadline
Issued 16 March 1999
Resolved
REPAIR FRACTURE PORT SIDE, SIDE LONG 7 FR #6 1/2.
Condition: Unknown
Due 16 April 1999
Resolved 7 April 1999
Construction/Loadline
Issued 16 March 1999
Resolved
CROP AND RENEW DAMAGED AREA, SIDE LONG 7, FR #11.
Condition: Unknown
Due 16 April 1999
Resolved 7 April 1999
Construction/Loadline
Issued 16 March 1999
Resolved
REPAIR FRACTURE, STBD SIDE SIDE LONG 7, FR #10 1/2.
Condition: Unknown
Due 16 April 1999
Resolved 7 April 1999
Construction/Loadline
Issued 16 March 1999
Resolved
REPAIR FRACTURE OF DECK HOUSE TO DECK CONNECTION, STBD SIDE FR #12.
Condition: Unknown
Due 16 April 1999
Resolved 7 April 1999
Construction/Loadline
Issued 16 March 1999
Resolved
REPAIR AREA OF FRACTURES STBD SIDE, FR #13.
Condition: Unknown
Due 16 April 1999
Resolved 7 April 1999
Construction/Loadline
Issued 16 March 1999
Resolved
CROP AND RENEW DAMAGED AREA PORT SIDE, SIDE LONGS 1-2, FR #17.
Condition: Unknown
Due 16 April 1999
Resolved 7 April 1999
Construction/Loadline
Issued 16 March 1999
Resolved
CROP AND RENEW DAMAGED AREA, STBD SIDE, SIDE LONGS 4-5 FR #6.
Condition: Unknown
Due 7 April 1999
Resolved 7 April 1999
Construction/Loadline
Issued 16 March 1999
Resolved
CROP AND RENEW FWD BULKHEAD, STBD SIDE OF AFT RAKE AT SIDE SHELL CONNECTIONSIDE LONGS 1-3.
Condition: Unknown
Due 7 April 1999
Resolved 7 April 1999
Electrical
Issued 23 February 1998
Resolved
DEMONSTRATE PROPER OPERATION OF GENERATOR INCLUDING OVERSPEED AND LOW LUBE OIL SHUTOFFS TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 28 February 1998
Resolved 2 March 1998
Electrical
Issued 17 March 1997
Resolved
PROVE PROPER OPERATION OF THE OVERSPEED SENSOR, THE OVERSPEED DID NOT WORK_x001C_BECAUSE THE GENERATOR ATTACHED TO THE DIESEL TO PROVIDE POWER FOR THE DIESELS OPERATING SYSTEMS WOULD NOT GENERATE ELECTRICITY. BARGE NOT TO USEGENERATOR UNTIL THIS ITEM IS CLEARED.
Condition: Unknown
Due 17 April 1997
Resolved 8 May 1997
Electrical
Issued 25 February 1993
Resolved
PROVIDE GLASS GLOBE ENCLOSURES FOR 2 OPEN LIGHT BULBS IN GENERATOR ROOM.
Condition: Unknown
Due 3 March 1993
Resolved 3 March 1993
Electrical
Issued 25 February 1993
Resolved
REMOVE ALL PLASTIC TIE WRAPS IN ALL WIRE RUNS IN GENERATOR ROOM AND REPLACEWITH METAL BANDS.
Condition: Unknown
Due 3 March 1993
Resolved 3 March 1993
Navigation
Issued 25 February 1993
Resolved
PROVE PROPER OPERATION OF PORT RUNNING LIGHT.
Condition: Unknown
Due 3 March 1993
Resolved 3 March 1993
Construction/Loadline
Issued 22 January 1992
Resolved
MAKE PERMANENT REPAIRS TO THE NUMBER 1 THRU 4 S/S LONGITUDINALS IN WAY OF THE TANK ENTRY MANHOLES FROM THE ADJACENT BLKHD TO 6-10 FEET TOWARD THE_x001C_ NEXT FRAME IN THE FOLLOWING TANKS: PORT/STBD BOW RAKE, #1 P/S, #3 P/S, #3A P, #4 P/S AND THE PORT/STBD STERN RAKES.
Condition: Unknown
Due 22 January 1992
Resolved 22 January 1992
Documentation
Issued 22 January 1992
Resolved
VSL IS PROHIBITED FROM CARRYING ANY FUEL OR CARGO ONBOARD, AND THE GENERATOR'S PRIME MOVER, FUEL TANKS AND OIL SUMP ARE TO REMAIN EMPTY AND GAS FREE UNTIL SUCH TIME AS THE VSL'S OPERATOR OBTAINS A VALID CERTIFICATE OF FINANCIAL RESPONSIBILITY
Condition: Unknown
Due 22 January 1992
Resolved 22 January 1992
Electrical
Issued 21 April 1987
Resolved
PROVE PROPER OPERATION ON THE OVERSPEED TRIP ON THE GENERATOR.
Condition: Unknown
Due 21 April 1987
Resolved 21 April 1987
Construction/Loadline
Issued 21 November 1986
Resolved
MAKE PERMANENT REPAIRS IN WAY OF TEMPORARY REPAIRS TO SIDE SHELL AND ASSOCIATED INTERNALS IN AFT PORT RAKE ON PORT CORNER.
Condition: Unknown
Due 21 November 1986
Resolved 21 November 1986
Construction/Loadline
Issued 16 October 1986
Resolved
MAKE PERMANENT REPAIRS TO TRIPPED STANTIONS AT FRAME 11 IN #3 PORT VOID. IFTHE VESSEL PROCEEDS TO SEATTLE, WA FOR REPAIRS, THE VESSEL SHALL PROCEED INAN UNLOADED CONDITION.
Condition: Unknown
Due 16 October 1986
Resolved 16 October 1986
Construction/Loadline
Issued 7 February 1986
Resolved
MAKE PERMANENT REPAIRS TO SHEER STRAKE, PORT SIDE, AFT, AT TANK #4 WHERE TEMPORARY DOUBLER ATTACHED.
Condition: Unknown
Due 7 February 1986
Resolved 7 February 1986
Construction/Loadline
Issued 7 February 1986
Resolved
MAKE PERMANENT REPAIRS TO RAKE, PORT SIDE, MAIN DECK AT BREAKWATER WHERE INSET.
Condition: Unknown
Due 7 February 1986
Resolved 7 February 1986
Construction/Loadline
Issued 7 February 1986
Resolved
REMOVE DOUBLER AND PROVIDE INSERT ON RAISED FOC'SLE PORTSIDE.
Condition: Unknown
Due 7 February 1986
Resolved 7 February 1986