Inspection record

Last inspected 2 February 2026
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDI7144
453988
Flag
UNITED STATES
Maury page id
psix-453988

Documentation record

Registered dimensions (L × B × D)115.2 ft × 37.0 ft × 10.5 ft
Registered tonnagegross 95 / net 64
ITC dimensions (L × B × D)115.2 ft × 37.0 ft × 10.5 ft
ITC tonnagegross 848 / net 293
BuilderLIBERTY BELLE CHARTERS · CHESTER, PA, UNITED STATES · built 1997
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portFORT MYERS, FL
Endorsements, as the file codes themcw_un
DocumentationValid · issued 14 July 2026 · expires 31 August 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it64 - Regulatory (Subpart C or D), Net Ton
293 - Convention (Subpart B), Net Ton
95 - Regulatory (Subpart C or D), Gross Ton
848 - Convention (Subpart B), Gross Ton
344 - Displacement, Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 20 inspections, each with its date, unit and type; 50 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 20

2 February 2026 Annual Inspection · MSP Additional Oversight - Risk Assessment
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8304735
18 November 2025 Internal Structural Exam · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8270504
5 December 2024 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8031526
20 December 2023 COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7836195
9 November 2023 Internal Structural Exam · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7822740
3 February 2023 Deficiency Check · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7631873
4 March 2022 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7405697
13 December 2021 Drydock Exam · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7367226
16 April 2021 Administrative Inspection · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7176308
13 February 2020 Deficiency Check · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6908289
13 November 2019 Internal Structural Exam · Hull Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6855391
27 November 2018 MTSA Verification · COI Inspection · Administrative Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6592728
6 February 2018 MTSA Verification · Deficiency Check · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6350088
29 December 2017 Administrative Inspection
Administrative · Navigation Center · Activity 6330292
8 November 2017 Internal Structural Exam · Hull Examination · Examination of Repairs
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6310831
14 April 2017 Deficiency Check · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6124315
6 April 2017 Administrative Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6119262
18 August 2016 Deficiency Check · In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5975961
6 April 2016 Attraction Vessel Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5848453
26 January 2016 Deficiency Check · Internal Structural Exam · Annual Inspection · Drydock Exam · DAPI Audit
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5803718

Deficiency record · 50

09 - Working and Living Conditions › 092 - Working Conditions › Protection machines/parts
Issued 5 February 2026 Resolved
"Suitable covers, guards, or rails shall be installed in way of exposed and hazardous places such as gears, machinery, etc." Generators have exposed belt drives. Install guards over belt drives. 46 CFR 177.35-15 (OLD T)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 February 2026
Resolved 14 April 2026
Resolution: Rcvd photos of guards reinstalled over generator belts
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 5 December 2024 Resolved
System design and installation must be in accordance with the Marine Design, Installation, Operation, and Maintenance Manual... MI witnessed unsatisfactory simulation test with fixed CO2 system. Did not witness a successful power shutdown. Have an MI witness a satisfactory test of the system.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 December 2024
Resolution: Witnessed sat. shut down
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 3 February 2023 Resolved
The following spaces must be equipped with a fire detecting system of an approved type that is installed in accordance with §76.27 in subchapter H of this chapter …: (1) A space containing propulsion machinery; (2) A space containing an internal combustion engine of more than 37.3 kW (50 hp). Demonstrate to attending MI proper testing of installed fire detection in engine room and bow thruster room, in accordance with manufacturer instructions / supplied equipment manual. 46 CFR 118.400(c), 701c
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 March 2023
Resolution: Operation demonstrated in part, def superceded by def #25
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 3 February 2023 Resolved
No more than 19 liters (five gallons) of flammable liquids may be stowed in any machinery space. The flammable liquids must be in containers of 3.8 liters (one gallon) or less. No more than 208 liters (55 gallons) of combustible liquids may be stowed in any machinery space. The general construction of the vessel must be such as to minimize fire hazards insofar as it is practicable. Vessel had excessive flammable/combustible liquid storage and storage of solid combustibles in engine room / bow thruster room. 46 CFR 147.45(c)&(d), 46 CFR 116.405(a), 701c
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 March 2023
Resolution: Ractification verified in person by MIs.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 3 February 2023 Resolved
Suitable means, such as a manual damper, automatic damper, or vent cover, must be provided in an accessible location outside the space served by the ventilation duct for shutting off the passage of air through the ventilation duct in the event of fire. A ventilation duct penetrating an A-Class or B-Class fire control boundary must meet the following requirements: (7) Ducts serving cargo spaces, machinery spaces, or vehicles spaces must be fitted with automatic fire dampers. An automatic fire damper must meet the above requirements [46 CFR (g)(1)-(g)(4)] and must be designed to operate at 74 °C (165 °F) for normal locations and approximately 100 °C (212 °F) for locations such as galleys. Engine room ventilation (in STBD aft corner) was unable to be successfully closed. This ventilation shaft penetrates an A-60 deck boundary. 46 CFR 116.610(d), 46 CFR 116.610(f)&(g), 701c
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 March 2023
Resolution: Ractification verified in person by MIs.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 3 February 2023 Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected. 46 CFR 115.830(a) Observed multiple instances of oil soaked lagging in the engine room. 46 CFR 115.830(a), 701c
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 March 2023
Resolution: Rectification verified in person by MIs.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 3 February 2023 Resolved
Machinery and equipment installed on each vessel must be suitable for the vessel and its operation and for the purpose intended. Lube oil leaks were observed on all main propulsion engines and generator prime movers. 46 CFR 119.100, 701c
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 March 2023
Resolution: Rectification verified in person by MIs.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 3 February 2023 Resolved
Marine employers shall establish programs for the chemical testing for dangerous drugs on a random basis of crewmembers on inspected vessels. 46 CFR 16.230(a) Certificate of enrollment in drug testing consortium was expired. 46 CFR 16.230(a), 701(c)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 February 2023
Resolution: Recieved documentation of currency via email, uploaded to documents
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 3 February 2023 Resolved
The general construction of the vessel must be such as to minimize fire hazards. Repairs or alterations to … equipment that affect the safety of the vessel must not be made without the approval of the cognizant OCMI. The owner or managing operator shall submit drawings, sketches, or written specifications describing the details of any proposed alterations to the cognizant [name withheld] alterations must be approved by the OCMI before work is started. SFP in AC room on Deck 1 did not meet required boundary based on fire control plan. Submit repair proposal for approval prior to commencing work. 46 CFR 116.405(a), 46 CFR 115.700(a)&(b), 50c
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 March 2023
Resolved 16 March 2023
Resolution: Rectification verified in person by MIs.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 3 February 2023 Resolved
Gauges to indicate engine revolutions per minute (RPM), jacket water discharge temperature, and lubricating oil pressure must be provided for all propulsion engines installed in the vessel. Multiple gauges were inoperable in the engine room. 46 CFR 119.410(b), 16c
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 February 2023
Resolved 16 March 2023
Resolution: Rectification verified in person by MIs.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 3 February 2023 Resolved
Complete but simple instructions for the operation of a fixed gas fire extinguishing system must be located in a conspicuous place at or near each pull box and stop valve control and in the space where the extinguishing agent cylinders are stored. If the storage cylinders are separate from the protected space, the instructions must also include a schematic diagram of the system and instructions detailing alternate methods of releasing the extinguishing agent should the local manual release or stop valve controls fail to operate. Each control valve to a distribution line must be marked to indicate the space served. Provide accurate schematic diagram. Review instructions and marking to ensure accuracy. 46 CFR 122.612(a), 16c
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 February 2023
Resolved 3 October 2023
Resolution: Cleared to the satisfaction of the attending MI.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 3 February 2023 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 February 2023
Resolved 16 March 2023
Resolution: Rectification verified in person by MIs.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 February 2023 Resolved
All cable and wire must be installed with metal supports spaced not more than 610 millimeters (24 inches) apart. … The use of plastic tie wraps must be limited to bundling or retention of multiple cable installations, and not used as a means of support. Cable/wire located in the engine room on the aft bulkhead/stbd side lacked appropriate metal supports. 46 CFR 120.340(b)(4), 16c
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 February 2023
Resolved 16 March 2023
Resolution: Rectification verified in person by MIs.
02 - Structural Conditions › N/A - No Subsystem › Loading/Ballast condition
Issued 3 February 2023 Resolved
On a vessel on which the number of passengers permitted on upper decks is limited by stability criteria, as indicated by the vessel’s stability letter, the maximum number of passengers allowed on an upper deck must be indicated by a durable marking of at least 1 inch numbers and letters at the entranceway to that deck. Vessel does not have markings to indicate number of passengers allowed on upper decks in accordance with stability letter.
Action required: 705 - Other - as specified
Due 17 February 2023
Resolved 16 March 2023
Resolution: Rectification verified in person by MIs.
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 3 February 2023 Resolved
The master and crew of a vessel will be familiar with the content of and have mounted at the operating station, emergency instructions containing the actions to be taken in the event of fire, flooding, heavy weather, or man overboard conditions. Emergency instructions were not mounted at the operating station. 46 CFR 122.510, 16c
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 February 2023
Resolved 3 October 2023
Resolution: Cleared to the satisfaction of the attendinng MI.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 3 February 2023 Resolved
Each vessel must have adequate emergency lighting fitted along the line of escape to the main deck from all passenger and crew accommodation spaces located below the main deck. Each door, hatch, or scuttle, used as a means of escape, must be capable of being opened by one person, from either side, in both light and dark conditions. Emergency lighting arrangement in liquor storeroom below the main deck did not illuminate secondary means of escape. 46 CFR 120.432(a), 46 CFR 116.500(i), 60c
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 March 2023
Resolved 16 March 2023
Resolution: Rectification verified in person by MIs.
05 - Radio Communications › N/A - No Subsystem › Distress messages: obligations and procedures
Issued 3 February 2023 Resolved
A durable placard must be posted next to all radiotelephone installations with the emergency broadcast instructions and information, specific to the individual vessel. Emergency broadcast placard with contents in accordance with 46 CFR 121.510 was not provided at the radio installation. 46 CFR 121.506, 16c
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 February 2023
Resolved 16 March 2023
Resolution: Rectification verified in person by MIs.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 3 February 2023 Resolved
An exposed hazard, such as gears or rotating machinery, must be protected by a cover, guard, or rail. Shafts were not protected in the steering compartment. 46 CFR 116.960, 50c
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 March 2023
Resolved 3 October 2023
Resolution: Cleared to the satisfaction of the attending MI
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 3 February 2023 Resolved
Placards containing instructions for the donning and use of the life jackets aboard the vessel must be posted in conspicuous places that are regularly accessible and visible to the crew and passengers. Placards with type-specific lifejacket donning instructions were absent. 46 CFR 112.516(a), 16c
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 February 2023
Resolved 16 March 2023
Resolution: Rectification verified in person by MIs.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 3 February 2023 Resolved
Each child size life jacket must be stowed in a location that is appropriately marked and separated from adult life jackets so the child size life jackets are not mistaken for adult life jackets. All lifejacket stowage locations lacked an appropriate method to separate child and adult lifejackets.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 February 2023
Resolved 16 March 2023
Resolution: Rectification verified in person by MIs.
04 - Emergency Systems › N/A - No Subsystem › Muster list
Issued 3 February 2023 Resolved
The owner, charterer, master, or managing operator shall instruct each crew member … at least once every three months, as to the duties that the crew member is expected to perform in an emergency including, but not limited to, the emergency instructions listed on the emergency instruction placard required by §122.510, when applicable, the duties listed in the station bill required by §122.514. Provide copy station bill with any necessary updates and proof of crew training. 46 CFR 122.420, 16c
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 February 2023
Resolved 16 March 2023
Resolution: Rectification verified in person by MIs.
08 - Alarms › N/A - No Subsystem › Fire alarm
Issued 3 February 2023 Resolved
The following spaces must be equipped with a fire detection and alarm system of an approved type that is installed in accordance with part 76 in subchapter H of this chapter... (1) A space containing propulsion machinery; (2) A space containing an internal combustion engine of more than 37.3 kW (50 hp). Vessel's fire detection and alarm system is not of an approved type and must be replaced with an approved system. 46 CFR 118.400(c), 50c
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 April 2023
Resolved 3 October 2023
Resolution: Final installation and alarm test completed to the satisfaction of the attending MI.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 3 February 2023 Resolved
For vessels required to meet the damage stability standards of subpart H of this chapter, when Class 1 doors are installed below a deck the molded line of which at its lowest point at side is less than 7 feet (2.14 meters) above the deepest load line, an indicator light for each door which warns when the door is open must be installed on the bridge. Vessel lacks indicator on bridge indicating status of WTD installed in Frame 41. 46 CFR 170.255, 50c
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 April 2023
Resolved 3 October 2023
Resolution: Cleared to the satisfaction of the attending MI
04 - Emergency Systems › N/A - No Subsystem › Safe areas
Issued 3 February 2023 Resolved
Each space accessible to passengers or used by the crew on a regular basis, must have at least two means of escape. “Doors in the travel path should swing in the direction of exit travel and should be operable without the use of a key from the egress side of the doors. If a lock is required on a door in the escape path, panic bar hardware should be provided.” One door IWO escape route lacked necessary panic bar hardware. 46 CFR 116.500(a), NVIC 9-97 Ch. 1, 50c
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 April 2023
Resolved 3 October 2023
Resolution: Cleared to the satisfaction of the attending MI
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 16 April 2021 Resolved
46 CFR 16.230(a) Marine employers shall establish programs for the chemical testing for dangerous drugs on a random basis of crew members on inspected vessels. Vsl is to provide an up to date crew list for the vessels DAPI program.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 April 2021
Resolved 30 April 2021
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 13 February 2020 Resolved
The master and crew of a vessel will be familiar with the content of and have mounted at the operating station, emergency instructions containing the actions to be taken in the event of fire, flooding, heavy weather, or man overboard conditions. Emergency instructions cited rescue boat and restaurant manager. Instructions were posted behind a window blind. Produce vessel specific instructions and post in a visible location. 46 CFR 122.510(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 February 2020
Resolved 26 February 2020
Resolution: Vessel submitted updated instructions.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 13 February 2020 Resolved
On a vessel on which the number of passengers permitted on upper decks is limited by stability criteria, as indicated by the vessel's stability letter, the maximum number of passengers allowed on an upper deck must be indicated by a durable marking of at least 25 millimeters (1 inch) numbers and letters at the entranceway to that deck. Post upper deck passenger limits IAW stability letter issued in 2016.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 February 2020
Resolved 25 February 2020
Resolution: Attended vessel and verified posted placards.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 13 February 2020 Resolved
A-Class bulkheads must be so constructed that, if subjected to the standard fire test, they are capable of preventing the passage of smoke and flame for 1 hour. Port bow, main deck door does not have latch required to ensure required A-60 boundary. Install door latch. 46 CFR 116.415
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 February 2020
Resolved 26 February 2020
Resolution: Reviewed video of repaired door latch.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 13 February 2020 Resolved
Employers must maintain records of chemical tests as provided in 49 CFR 40.333 and must make these records available to Coast Guard officials upon request. Vessel rep could not produce list of tested crew members. generate list and add to vessel DAPI folder 46 CFR 16.260
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 February 2020
Resolved 25 February 2020
Resolution: Attended vessel and verified list of crew members.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 27 November 2018 Resolved
Your vessel must submit a written application for a renewal of the Certiifcate of Inspection at least 30 days prior to the COI expiration date. Vessel's COI is currently expired and shall complete a renewal COI inspection prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 December 2018
Resolution: Vessel completed renewal COI Inspection
Electrical › Electrical Distribution System (service) › Ground Detection
Issued 6 February 2018 Resolved
Demonstrate operation of 480V ground detection. If a grounded distribution system is provided, there must be only one connection to ground, regardless of the number of power sources. This ground connection must be at the switchboard or at the common ground plate, which must be accessible. Vessel is showing 2 amps of ground when connected on shore power. Vessel must not have two ground connection points and eliminate ground fault. [46 CFR 120.376(a)]
Action required: 705 - Other - as specified
Due 14 February 2018
Resolved 29 June 2018
Resolution: Vessel provided an operational ground detection system.
Electrical › Lighting (service) › Lighting Fixture
Issued 6 February 2018 Resolved
Provide 3 light covers in the soda room.
Action required: 705 - Other - as specified
Due 14 February 2018
Resolved 31 May 2018
Resolution: Verified light covers were replaced.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 6 February 2018 Resolved
Post COI and emergency instructions in area accesible to passengers.
Action required: 705 - Other - as specified
Due 14 February 2018
Resolved 31 May 2018
Resolution: Verified COI and emergency instructions were posted, as required.
Fire Fighting › Structural Fire Protection - General › Accommodation Space Protection
Issued 6 February 2018 Resolved
Determine fire boundary for dumbwaiter on main deck.
Action required: 705 - Other - as specified
Due 14 February 2018
Resolved 29 June 2018
Fire Fighting › Structural Fire Protection - General › Accommodation Space Protection
Issued 6 February 2018 Resolved
Prove operation of 2nd deck fire door.
Action required: 705 - Other - as specified
Due 14 February 2018
Resolved 31 May 2018
Resolution: Verified proper operation of fire door.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Tanks
Issued 14 April 2017 Resolved
1. PROPERLY RAISE AND SECURE FIXED FIRE FIGHTING CO2 TANKS 2 INCHES OFF DECK.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 14 May 2017
Resolved 19 May 2017
Engineering › Engine Controls (Electric/Electronic) › Circuit Board
Issued 14 April 2017 Resolved
2. PROPERLY HOUSE LOOSE WIRING ON MAIN ENGINE CONTROLE PANELS.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 14 May 2017
Resolved 19 May 2017
Electrical › Electric Generation Source (service) › Generator
Issued 14 April 2017 Resolved
3. PROPERLY REPAIR LEAK AND EXHAUST LAGGING ON STBD GENERATOR.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 14 May 2017
Resolved 19 May 2017
Electrical › Electrical Distribution System (service) › Wiring
Issued 14 April 2017 Resolved
4. REMOVE GREY WATER PUMP ELECTRICAL CONNECTION.
Action required: 705 - Other - as specified
Due 14 May 2017
Resolved 19 May 2017
Construction/Loadline › Structures › Transverse Bulkhead
Issued 14 April 2017 Resolved
5. ENSURE IDENTIFIED WATERTIGHT BULKHEADS ARE WATERTIGHT, MAINLY THROUGH HOLE FROM STORAGE ROOM TO WATER TANK ROOM.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 21 July 2017
Resolved 12 September 2017
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 18 August 2016 Resolved
All adult passengers may be carried unitl 720 extended size life preservers are provided or 72 children life preservers are provided. 46CFR117.71(b) PRIOR TO CARRYING CHILDREN UNDER 90 POUNDS.
Condition: Invalid
Action required: 705 - Other - as specified
Due 19 August 2017
Resolved 18 August 2016
Resolution: Vessel operator added all extended-type lifejackets.
Lifesaving › Rescue Boat › Inflated Condition
Issued 18 August 2016 Resolved
Repair starboard sponson on rescue boat IAW manufacturer standards. 46CFR117.210
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 August 2016
Resolved 19 August 2016
Resolution: Vessel operator sent photograph attesting to inflated sponsor of rescue boat.
Lifesaving › Rescue Boat › Carriage Requirement
Issued 18 August 2016 Resolved
Properly mount oars to rescue boat. 46CFR160.056
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 August 2016
Resolved 19 August 2016
Resolution: Vessel owner sent photograph attesting to properly mounted oars on rescue boat.
Fire Fighting › Ventilation Systems › Ventilation Fire Dampers
Issued 24 February 2016 Resolved
Provide proper operation of ventilation intake louvers during CO2 system activation test.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 March 2016
Resolution: Vessel provided proper operation of ventilation intake louvers during CO2 system activation test.
Construction/Loadline › Structures › Scuttle
Issued 24 February 2016 Resolved
Forepeak hatch gasket edge is wasted through. Crop out wasted edging and renew.
Action required: 705 - Other - as specified
Due 9 March 2016
Resolved 1 March 2016
Resolution: Forepeak hatch gasket edge renewed.
Electrical › Electric Supply System (service) › Battery Installation
Issued 24 February 2016 Resolved
Replace melted battery box cover in port/aft engine room.
Action required: 705 - Other - as specified
Due 9 March 2016
Resolved 1 March 2016
Resolution: Battery box cover in port/aft engine room was replaced.
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 24 February 2016 Resolved
Provide required quantity of child's PFDs.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 March 2016
Resolution: Vessel provided required quantity of child's PFDs per COI.
Lifesaving › Lifejacket/PFD (General) › Retroreflective Material
Issued 24 February 2016 Resolved
Renew retroreflective tape with SOLAS approved tape on child's PFDs.
Action required: 705 - Other - as specified
Due 9 March 2016
Resolved 1 March 2016
Resolution: Vessel renewed retroreflective tape with SOLAS approved tape on child's PFDs.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 24 February 2016 Resolved
Ensure PFD storage locker door on 3rd deck opens and closes freely.
Action required: 705 - Other - as specified
Due 9 March 2016
Resolved 1 March 2016
Resolution: Vessel ensured PFD storage locker door on 3rd deck opens and closes freely by rewelding new hinge to upper portion of the door.
Documentation › Safety Management System › Emergency Drill/Exercise Programs
Issued 24 February 2016 Resolved
Conduct underway fire and man overboard drills.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 March 2016
Resolution: Vessel conducted satisfactory underway fire and man overboard drills.