Freight Ship · General Dry Cargo Ship class · Built 1960s · USCG Southwest District (CGD-SW) · Other hulls named DANNY C
DANNY C is a 1966 freight ship. The Coast Guard has recorded 42 inspections since 1985, most recently in May 2025, along with 45 deficiencies.
Records from 1985 to 2025. Most recent: inspection, 1 May 2025.
- Built
- 1966
- Last inspected
- 1 May 2025
- Documentation
- Expired · documentation file of 10 September 2026
- Deficiencies
- 45 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
506332
WBE8593
45406
Flag
UNITED STATES
—
Maury page id
psix-45406
Inspections, by type
…with no type recorded5
Years with a record
19 calendar years (1985–2025)
The 42 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.
Documentation record
Registered dimensions (L × B × D)73.7 ft × 25.0 ft × 7.7 ft
Registered tonnagegross 92 / net 63
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderBLOUNT MARINE CORPORATION · PROVIDENCE, RI, UNITED STATES · built 1966
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portSANTA BARBARA, CA
Trade endorsementsCoastwise, unrestricted, Fishery, Recreational
DocumentationExpired · issued 30 June 2004
Service, as the file records itFreight Ship
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it92 - Regulatory (Subpart C or D), Gross Ton
63 - Regulatory (Subpart C or D), Net Ton
63 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 42
1 May 2025
Drydock Exam · Internal Structural Exam · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8106589
27 February 2025
In-Service Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 8085881
3 September 2024
COI Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7992414
29 November 2023
Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7831206
13 September 2023
Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7791201
8 November 2022
In-Service Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7591828
19 October 2022
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7560594
17 August 2022
Inclining Experiment
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7481837
24 May 2022
Internal Structural Exam
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7454305
23 November 2021
Drydock Exam · Construction Oversight · Deficiency Check · Internal Structural Exam · Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7357268
16 November 2021
Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7306814
12 November 2020
In-Service Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7094316
23 September 2020
Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7055050
16 March 2020
Internal Structural Exam · Drydock Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6927688
30 September 2019
COI Inspection · DAPI Audit · Deficiency Check
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6819716
19 August 2019
In-Service Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6807836
11 April 2019
In-Service Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6661296
25 September 2018
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6537052
7 September 2018
In-Service Inspection · Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6591392
14 November 2017
Plan Review (Other than "T") · Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6313653
26 July 2017
Type not recorded
No type recorded · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6221695
7 July 2017
In-Service Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6201448
2 June 2017
Internal Structural Exam · Drydock Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6148409
14 November 2016
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6040632
9 November 2015
Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 5758042
3 October 2014
Deficiency Check · DAPI Audit · COI Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 4995639
14 May 2012
Internal Structural Exam · Drydock Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4253963
6 January 2012
DAPI Audit · Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 4219916
31 August 2011
Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 4133917
10 August 2011
Deficiency Check
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 4111365
2 February 2011
In-Service Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 3948253
23 November 2010
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 3897306
9 September 2010
Hull Examination · Deficiency Check
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 3846438
3 September 2010
Internal Structural Exam
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 3844111
9 February 2010
Administrative Inspection
Administrative · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 3677726
26 September 2008
Type not recorded
No type recorded · USCGC BLACKFIN (WPB 87317) · USCG Southwest District (CGD-SW) · Activity 3337259
2 April 2008
Inclining Experiment
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 3176230
5 February 2006
Plan Review (Other than "T") · Initial Certification · COI Inspection · In-Service Inspection · Construction Oversight · Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2993605
27 May 1986
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1297267
7 April 1986
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 998244
26 August 1985
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1294451
23 August 1985
Credit Drydock
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1294449
Deficiency record · 45
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 29 November 2023
Resolved
Each entrance to a space storing CO2 cylinders, a space protected by CO2 systems, or any space into which CO2 might migrate must be conspicuously marked as follows: Spaces protected by CO2 – “CARBON DIOXIDE GAS CAN CAUSE INJURY OR DEATH. WHEN ALARM OPERATES OR WINGREEN SCENT IS DETECTED, DO NO ENTER UNTIL VENTILATED. LOCK OUT SYSTEM WHEN SERVICING.” This sign is to be posted on the watertight door leading into the machinery space from the lazarette and the main hatch to the machinery space on the port side.
46 CFR 97.37-11
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 29 November 2023
Resolved
Each entrance to a space storing CO2 cylinders, a space protected by CO2 systems, or any space into which CO2 might migrate must be conspicuously marked as follows: Spaces storing CO2 – “CARBON DIOXIDE GAS CAN CAUSE INJURY OR DEATH. VENTILATE THE AREA BEFORE ENTERING. A HIGH CONCENTRATION CAN OCCUR IN THIS AREA AND CAN CAUSE SUFFOCATION.” This sign is to be posted on the inside of the hatch to the CO2 storage area.
46 CFR 97.37-11
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 29 November 2023
Resolved
All escape hatches and other emergency exits used as means of escape must be marked on both sides in clearly legible letters at least 2 inches high: “EMERGENCY EXIT – KEEP CLEAR”. The emergency escape from the starboard side of the engine room and the bunk area were not marked on the open deck.
46 CFR 185.606
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 29 November 2023
Resolved
Nonconducting mats or gratins shall be provided on deck in the front and rear of switchboards. Provide nonconducting mat for front of main switchboard.
46 CFR 96.05-1
46 CFR 111.30-1(c)
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 29 November 2023
Resolved
A vessel must carry a first aid kit approved under approval series 160.041. The aspirin, eye wash, burn gel, and ammonia inhalants were expired or not provided. Provide full first aid kit to satisfaction of a Marine Inspector.
46 CFR 184.710
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 29 November 2023
Resolved
The marine employer shall ensure that all persons directly involved in a serious marine incident are chemically tested for evidence of dangerous drugs and alcohol IAW 46 CFR 4.06. Provide alcohol swabs for crew complement.
46 CFR 16.240
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 29 November 2023
Resolved
Before the vessel leaves port and at all times during the voyage, each lifesaving appliance must be in working order and ready for immediate use. The hydrostatic release unit for the life raft was expired. Crew purchased new HRU on the spot and replaced. New HRU to expire in December of 2025.
46 CFR 96.06-1
46 CFR 199.190
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 19 October 2022
Resolved
Nothing in this subpart shall be construed as limiting
the inspector from making such tests or inspections as
he or she deems necessary to be assured of the
seaworthiness of the vessel. A pre-engineered fixed gas
fire extinguishing system must automatically shut down
all engines that draw intake air from within the
protected space. The pre-engineered fixed gas fire
extinguishing system protecting lazarette did not
automatically shut down crane/winch engine which draws
intake air from within the protected space. The engine
in lazarette may not be used until fixed fire fighting
shutdown failure is diagnosed, repaired, and tested to
the satisfaction of the attending Marine Inspector.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 19 October 2022
Resolved
All lifesaving appliances and arrangements must be in
accordance with subchapter W (Lifesaving Appliances and
Arrangements. Each lifejacket must have a lifejacket
light approved under approval series 161.112 securely
attached to the front shoulder area of the lifejacket.
01 lifejacket light was inoperable. Replace/repair to
satisfaction of attending Marine Inspector.
02 - Structural Conditions › N/A - No Subsystem › Stability/strength/loading information and instruments
Issued 15 February 2022
Resolved
46 CFR 93.01-1: "Each vessel must meet the applicable requirements in subchapter S of this chapter." Vessel is required to have lightship characteristics / weight changes submitted to MSC for review. Upon receipt of determination of applicable stability requirements from MSC, the vessel will have 30 days to affect a stability survey per MSC's direction due to weight changes to the vessel. Vessel is restricted to maximum deck loading capacity by 75% and crane lifting capacity by 75%.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 16 November 2021
Resolved
In general, compliance with the standards established by
the American Bureau of Shipping, see subpart 90.35 of
subchapter I, will be considered as satisfactory
evidence of the structural efficiency of the vessel.
However, in special cases, a detailed analysis of the
entire structure or some integral part may be made by
the Coast Guard to determine the structural
requirements. Port-side hull was found wasted (pinhole
leak) below the waterline under the ladder in forepeak.
Provide gauging report for area ivo wastage, along with
repair proposal to attending Marine Inspector. forepaeak
shall be inspected daily while underway & kept dry.
Daily inspection shall be logged until deficiency
cleared.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 16 November 2021
Resolved
Each section of firehose must be lined commercial
firehose that conforms to Underwriters' Laboratories,
Inc. Standard 19 or Federal Specification ZZ-H-451E.
Hose that bears the label of Underwriters' Laboratories,
Inc. as lined firehose is accepted as conforming to this
requirement. Starboard firehose had pinhole leaks.
Repair/replace as per manufacturer specifications and to
the satisfaction of attending Marine Inspector.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 16 November 2021
Resolved
A person may not employ or engage an individual in a position required to hold an MMC unless that individual
maintains a current medical certificate. Vessel's
licensed Master did not have medical certificate
available for inspection. Provide proof of medical
certificate or correspondence from NMC attesting to
valid medical certificate.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 16 November 2021
Resolved
The marine employer must have a sufficient number of
alcohol testing devices readily accessible on board the
vessel to determine the presence of alcohol in the
system of each individual who was directly involved in
the SMI. Vessel's alcohol testing devices were expired.
Vessel was able to provide unexpired and valid alcohol
testing devices as required.
07 - Fire Safety › N/A - No Subsystem › Fire control plan
Issued 23 September 2020
Resolved
Provide an updated fire control plan.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 23 September 2020
Resolved
Provide line diagram and instructions for fixed fire system.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 23 September 2020
Resolved
Provide updated documents for DAPI program.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 30 September 2019
Resolved
All equipment must be suitable for the roll, pitch and vibration, as well as voltage and current utilized. Power strip observed in the pilot house. Remove power strip.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 30 September 2019
Resolved
Each cable installation must meet applicable sections of IEEE or IEC. Refrigerator found on deck powered through an extension cord running through the superstructure window. Remove extension cord.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 30 September 2019
Resolved
Lighting fixtures must be installed to minimize damage when exposed on the weather deck. Lighting fixture found installed on the weather deck aft of the superstructure wire tied in place and not permanently wired. Permanently wire or remove light fixture aft of house.
11 - Life Saving Appliances › N/A - No Subsystem › Immersion suits
Issued 30 September 2019
Resolved
The manufacturer's instructions for on board maintenance of lifesaving appliances must be on board the vessel and must be used in carrying out monthly inspections. Immersion suits were found that had not been inspected or maintained. Provide plan and conduct maintenance on lifesaving equipment in accordance with manufacturer's instructions.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 30 September 2019
Resolved
Each lighting fixture must be fixed. Light fixture in engine room not properly mounted above port generator. Properly mount lighting fixture.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 30 September 2019
Resolved
Each lifeline on a ring buoy must be buoyant and be of a dark color if synthetic, or of a type certified to be resistant to deterioration from ultraviolet light. Provide buoyant black or ultraviolet resistant line for port lifebuoy.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 30 September 2019
Resolved
The inspection shall be such that as to insure that the vessel is in satisfactory condition and is fit for the service for which it was intended. Due to cargo loading operations vessel was unable to demonstrate man overboard drills and underway demonstration of vessel machinery. Conduct underway man overboard drill in the presence of a USCG Marine Inspector.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 19 August 2019
Resolved
Provide a working ground indicator.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 25 September 2018
Resolved
Replace port fire hose.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 25 September 2018
Resolved
Replace stbd side lifering.
Communications › Radio Communications › EPIRB
Issued 22 December 2017
Resolved
Replace hydrostatic release for EPIRB.
Operations/Management › Drug and Alcohol Testing › MIS Submission
Issued 22 December 2017
Resolved
Provide 2017 drug consortium letter, current employee list and 2016 MIS report.
Fire Fighting › Remote Fuel Shutoff › General
Issued 22 December 2017
Resolved
Mark fuel shut-off valves.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 22 December 2017
Resolved
Provide fire fighting service report for 2017.
Lifesaving › Lifebuoys › Serviceable
Issued 22 December 2017
Resolved
Renew 02 life rings.
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 22 December 2017
Resolved
Provide emergency broadcast placard.
Stability › Intact Stability (when using lifting gear) › General
Issued 7 July 2017
Resolved
Submit plans and stability calculations to MSC for installed deck A-Frame prior to use.
Communications › Radio Communications › EPIRB
Issued 14 November 2016
Resolved
Replace EPIRB Battery IAW Manufacturer's Specs.
Navigation › Piloting/Steering › Marine Charts
Issued 14 November 2016
Resolved
Provide proof of chart for indended areas or operations
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 14 November 2016
Resolved
Provide proof of DAPI enrollment data for crew
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 14 November 2016
Resolved
Provide firefighting servicing certificate for firefighting equipment
Electrical › Electrical Distribution System (service) › Panelboard
Issued 14 November 2016
Resolved
Label A/C subpanel in E/R
Communications › Radio Communications › Radiotelephone Transceiver (2-27.5 MHz)
Issued 3 October 2014
Resolved
Prove proper operation of the SSB.
Lifesaving › Rocket Parachute Flares › General
Issued 3 October 2014
Resolved
Provide one additional parachute flare for a total of 12.
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 3 October 2014
Resolved
Provide alcohol testing device or saliva test strips on board.
Stability › Weathertight Integrity › General
Issued 3 October 2014
Resolved
Replace cracked stbd aft bridge window.
Operations/Management › Drills/Instruction › Abandon Ship
Issued 23 November 2010
Resolved
Conduct emergency drills in presence of Coast Gurad Inspector, including donning survival suits.
Construction/Loadline › Structures › Deck Plating
Issued 9 September 2010
Resolved
Make storage compartment fwd of engine room available for inspection.