Records from 2007 to 2022. Most recent: inspection, 28 September 2022.
Everything above is free. The detail below — the inspection history, the deficiency record, the operational controls, the recorded names, the casualty record and the documentation record — is Professional, $39 a month. Sign in.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 17 November 2022
Resolved
Identified hole near the rubrail on port side of the stern.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 December 2022
Resolved 23 January 2023
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 27 January 2022
Resolved
All ducts shall be rigid permanent construction of fire proof material and reasonably gastight and properly fastened and supported. Port engine room ventilation duct was found not supported and would not close to cut ventilation from the space. Install or repair duct cover to securely fasten duct cover.
Action required: 705 - Other - as specified
Due 27 January 2022
Resolved 27 January 2022
Resolution: Rectified prior to completing Inspection
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 27 January 2022
Resolved
Number and Type of Survival craft must be maintained in good and serviceable condition IAW the vessels route. One 8-person lifefloat was found damaged. Repair or replace the damaged lifefloat. The vessel is restricted from carrying more than 18 passengers until the lifefloat is either repaired of replaced.
Action required: 705 - Other - as specified
Resolved 28 February 2022
Resolution: Received Photo evidence of repaired life Float.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 27 January 2022
Resolved
At each inspection for certification and subsequent inspection for certification, all observed unsafe practices and hazardous situations shall be corrected. Multiple grounds were detected at the accommodation space outlets. Make repairs and submit Tech report to USCG.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 February 2022
Resolved 28 February 2022
Resolution: Owners replaced and faulty ground wife inside the main engine breaker panel.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 27 January 2022
Resolved
During each initial and subsequent inspections, the hull shall be examined IAW standards acceptable to the OCMI to determine the structural integrity of the vessel is fit for the intended route and service. 4 crack were identified in the vessel forward compartment. Repair the identified cracks.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 February 2022
Resolved 28 February 2022
Resolution: Received photos of repaired cracks in the forepeak.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 9 December 2020
Resolved
The owner or managing operator shall make sure that maintenance of survival craft is carried out in accordance with the manufacturer's instructions and that weekly and monthly maintenance inspections are conducted and recorded using the manufacturer's instructions to make sure the survival craft are complete and in good order.
Three lifefloats installed onboard were found deteriorated and in need of repair or replacement in accordance with manufacturer's instructions/recommendations.
Fully repair or replace the three lifefloats in accordance with the manufacturer's instructions to the satisfaction of the attending Coast Guard Marine Inspector.
46 CFR 185.702
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 January 2021
Resolved 27 January 2022
Resolution: verified repaired onboard.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 12 December 2019
Resolved
Marine inspector shall examine and test the main and auxiliary steering apparatus to determine that its condition is satisfactory. Steering gear ram not adequately installed & the rudder stops are wasted away.
Repair rudder stops and adequately install steering ram.
46 CFR 176.25-35
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 12 December 2019
Resolved 16 January 2020
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 12 December 2019
Resolved
Vessels shall carry 6 hand-held red flare and 6 handheld smoke distress signals or 12 hand combination flares. Vessel missing 03 hand-held flares smoke and the other 3 were expired. Provide required compliment of flares.
46 CFR 180.35-5
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 12 December 2019
Resolved 16 January 2020
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 12 December 2019
Resolved
Marine inspector shall require that all observed unsafe practices and hazardous conditions be corrected. Several oil absorbent pads are laying in the vessel's bilge. Remove absorbent pads from the bilge.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 12 December 2019
Resolved 16 January 2020
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 12 December 2019
Resolved
Each life float shall be properly fitted. Life floats are attached using improper weak-links, the stacked life-floats on the port side are not separated, and the paddles are not properly stowed inside the life-floats.
Properly fit life-floats.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 12 December 2019
Resolved 17 January 2020
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 12 December 2019
Resolved
Vessels shall be provided with an approved adult life-jacket for each person carried. Vessel authorized to carry 30 people but only had 29 adult jackets on board. The 06 children life-jackets were missing but were provided during inspection. Vessel limited to 29 POB until all required life jackets are provided on board & the adult life jacket stowage placard on the port side needs to be removed.
46 CFR 180.25-5
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 December 2019
Resolved 16 January 2020
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 12 December 2019
Resolved
Commercial inspected vessels must be outfitted with with navigation lights that meet or exceed UL 1104. LED nav lights are installed without proof of meeting UL 1104.
Provide proof that the nav lights meet UL 1104 or replace them with ones that do.
46 CFR 111.75-17
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 December 2019
Resolved 16 January 2020
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 12 December 2019
Resolved
A vessel at anchor shall exhibit where it can best be seen: In the fore part, an all-round white light or one ball. The anchor light power source is tied into deck lighting. Install the anchor light so that it can be lit by itself. 33 CFR 83.30
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 December 2019
Resolved 16 January 2020
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 12 December 2019
Resolved
Plans for small passenger vessel diesel fuel tanks shall be submitted, reviewed and approved by local OCMI or MSC. Vessel rep could not provide proof that newly installed fuel tank was approved for install and tested iaw CFR. Provide proof that fuel tank was approved and built to regulation.46 CFR 182.20-25
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 December 2019
Resolved 13 December 2019
Resolution: Vessel rep provided proof that installed fuel tank was approved by USCG.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 12 December 2019
Resolved
A CG inspection is required whenever major repairs or alterations are undertaken. Substantial repairs were made after damage was caused to port side and mast. Provide repair plan and proof the repairs were done accordingly. 46 CFR 176.20-5
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 December 2019
Resolved 13 December 2019
Resolution: Vessel rep provided documentation of sat repairs. Repair invoice attached.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 12 December 2019
Resolved
Rails shall be installed at the periphery of all weather decks accessible to passengers / crew and hull structure shall be sound. Several deck rails are cracked and some welds in the fore peak need to be repaired. 46 CFR 177.35-1
46 CFR 177.10-1
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 December 2019
Resolved 16 January 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 12 December 2019
Resolved
Engine exhaust shall be securely installed. The generator exhaust hose is laying in the bilge and needs to be properly secured/hung.46 CFR 182.20-15
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 December 2019
Resolved 16 January 2020
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 12 December 2019
Resolved
Vessels must carry up to date navigation charts.
Although the vessel generally goes on short voyages in the same area it is certified for oceans route and is carrying outdated charts.46 CFR 185.20-35
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 December 2019
Resolved 17 December 2019
Resolution: Vessel rep bought new marine charts
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 12 December 2019
Resolved
Vessels with more than one deck need to label the maximum capacity for upper-decks. The upper deck is not labeled with max capacity of 10 pax as indicted in the stability letter and COI. 46 CFR 185.12-1
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 December 2019
Resolved 16 January 2020
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 12 December 2019
Resolved
Wiring splices and junctions shall be made in adequate junction boxes. The mast light junction box needs to be replaced due to severe corrosion. 46 CFR 183.05-50(b)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 December 2019
Resolved 16 January 2020
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 12 December 2019
Resolved
Lifebuoys shall be marked with vessels name and one shall have floating light. Vessel's name is faded and needs to be renewed; as well as, the floating light battery is corroded and needs to be replaced.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 December 2019
Resolved 16 January 2020
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 12 December 2019
Resolved
Marine employers shall ensure crew directly involved in serious marine incidents can provide drug testing iaw with DOT within 32 hours. Company provided urine sample kits but nobody is certified as a collector.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 December 2019
Resolved 16 January 2020
02 - Structural Conditions › N/A - No Subsystem › Bulkheads - cracking
Issued 20 August 2018
Resolved
Cracked weld in engine room aft of starboard bulkhead
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 September 2018
Resolved 11 September 2018
Resolution: Vessel had cracked weld in engine room repaired.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 20 August 2018
Resolved
Machinery guard starboard engine forward was missing
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 September 2018
Resolved 11 September 2018
Resolution: Machinery guard installed on stb engine.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 20 August 2018
Resolved
Replace 3 lifejackets - retrotape was peeling off and irreperable - limited 6 POB o/b until all lifesaving deficiencies corrected
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 September 2018
Resolved 11 September 2018
Resolution: Vessel rep purchased 4 new lifejackets.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 20 August 2018
Resolved
Port and Starboard 12 man lifefloats were damaged - required to be replaced - limited 6 POB o/b until all lifesaving deficiencies corrected
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 September 2018
Resolved 11 September 2018
Resolution: Vessel rep purchased two new lifefloats.
11 - Life Saving Appliances › N/A - No Subsystem › Operation of Life Saving Appliances
Issued 20 August 2018
Resolved
Weak link on 12 man lifefloats was for 6-10 rather than 12 - required to be for 12 man lifefloat - limited 6 POB o/b until all lifesaving deficiencies corrected
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 11 September 2018
Resolution: Vessel rep purchased two new weak link for lifefloats.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 20 August 2018
Resolved
Lifelight needs line was not synthetic, as required
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 September 2018
Resolved 11 September 2018
Resolution: Lifelight line has been renewed with synthetic line.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 20 August 2018
Resolved
Waterlight missing from life float
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 September 2018
Resolved 11 September 2018
Resolution: Waterlights have been installed for lifefloats.
Engineering › Fuel Oil Service System › Hose
Issued 17 January 2017
Resolved
03 flexible fuel lines on the starboard MDE are dry-rotted. All flexible, non-metallic hoses must meet SAE-J1942 standards. Replace dry-rotted fuel hoses with SAE-J1942 or equivelant hoses.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 January 2017
Resolved 20 January 2017
Resolution: Hoses replaced to the satisfaction of the attending USCG Marine Inspector
Electrical › Electrical Distribution System (service) › Cable
Issued 17 January 2017
Resolved
Generator supplied ower source to the AC unit is not properly installed at the distribution panel. Openings into the panel shall be closed with the cable secured to the box or fitting.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 31 January 2017
Resolved 20 February 2017
Resolution: All openings into the distribution panel were repaired/closed.
Electrical › Electric Supply System (service) › Cable
Issued 17 January 2017
Resolved
Plastic zip ties are being used to support electrical overhead wire runs in all spaces. Cables shall be supported by metal hangers. Replace plastic zip ties with metal hangers.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 31 January 2017
Resolved 20 February 2017
Resolution: Zip ties were removed and replaced with metal hangers.
Electrical › Electric Supply System (service) › Cable
Issued 17 January 2017
Resolved
Dead end cables are in forepeak bilge and #2 void. Cables no longer in use must be removed. Remove all dead end cables.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 31 January 2017
Resolved 20 February 2017
Resolution: Dead end cables were removed.
Engineering › Fuel Oil Service System › Piping
Issued 17 January 2017
Resolved
Fuel oil fill pipes are not protected against static charge. Metallic fuel fill pipes must be protected. Provide grounding strap on fuel fill pipe.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 31 January 2017
Resolved 20 February 2017
Resolution: Fill pipes were grounded.
Engineering › Bilge Water Management System › Hose
Issued 17 January 2017
Resolved
Bilge pump hoses in all spaces are not adequate for intended use due to deterioration. Hoses must be serviceable. Replace/renew bilge hoses and prove proper operation.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 January 2017
Resolved 20 January 2017
Resolution: Bilge hoses satisfactorily replaced, and bilge pumps tested to the satisfaction of attending USCG Marine Inspector.
Lifesaving › Buoyant Apparatus › Serviceable
Issued 17 January 2017
Resolved
Buoyant apparatus' are no longer orange in color. BAs must be international orange in color.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 February 2017
Resolved 20 February 2017
Resolution: BAs were replaced.
Lifesaving › Buoyant Apparatus › Float Free
Issued 17 January 2017
Resolved
Buoyant Apparatus must be float free. BAs are not float free due to improper line stowage. BAs must be stowed in a manner that allows easy release.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 21 January 2017
Resolved 20 February 2017
Resolution: BAs are stored so that they will float free.
Lifesaving › Buoyant Apparatus › Float Free
Issued 17 January 2017
Resolved
Buoyant apparatus' are stowed directly on top of one another. BAs must have separation when stacked. Provide spacers between BAs.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 17 February 2017
Resolved 20 February 2017
Resolution: BAs were stored with separation between each.
Accommodation/Occupational Safety › Washroom/Toilet › Toilet
Issued 17 January 2017
Resolved
All vessels equipped with toilet facilities must have MSD tanks. Vessel does not have a MSD tank. Install approved MSD tank.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 17 February 2017
Resolved 11 April 2017
Resolution: MSD was installed.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 17 January 2017
Resolved
Vessel O/O did not have proof of current DAPI program enrollment. All current employees must be enrolled in a DAPI program. Provide proof of DAPI program enrollment.
Condition: Invalid
Action required: 705 - Other - as specified
Due 19 January 2017
Resolved 18 January 2017
Resolution: Proof of DAPI program enrollment was provided.