MAURY USCG vessel records Sign in
← All vessels

MAJOR JOE

MAJOR JOE is a 1966 passenger vessel (inspected). The Coast Guard has recorded 28 inspections since 1982, most recently in August 1997, along with 23 deficiencies.

Records from 1982 to 1997. Most recent: inspection, 10 August 1997.

Built
1966
Last inspected
10 August 1997
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WBR8554
Flag
UNITED STATES
—
Maury page id
psix-45421

Inspections, by type

…with no type recorded8
Years with a record 13 calendar years (1982–1997)
The 28 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 29 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it64 - Regulatory (Subpart C or D), Net Ton
95 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WBR8554MMSI not assigned · expired · compulsorily equipped · granted 16 February 1996, cancelled 22 April 2006
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 28

10 August 1997 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 782116
29 January 1996 COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1359033
6 March 1995 Hull Examination · COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1394282
19 April 1994 Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 856957
2 March 1994 COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1359723
16 September 1993 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 668857
13 July 1993 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 224710
11 March 1993 Hull Examination · COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 836962
17 December 1992 Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1135365
30 November 1992 Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 832659
21 October 1992 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 661540
19 October 1992 Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 830373
19 October 1992 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1441969
13 August 1992 Drydock Extension
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1270486
11 June 1992 Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1263705
30 March 1992 COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 944921
5 April 1991 Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1225109
25 March 1991 COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1217647
20 February 1991 Hull Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1219420
11 October 1988 Administrative
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1194058
22 July 1988 COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1343281
22 July 1987 Hull Examination · COI Inspection · Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1030378
3 April 1987 Hull Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1020220
26 March 1987 Type not recorded
No type recorded · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1326723
6 November 1985 COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 993774
22 December 1984 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1284800
25 May 1983 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 967073
12 May 1982 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 963683

Deficiency record · 23

Construction/Loadline
Issued 2 March 1994 Resolved
MAKE BULKHEAD PENETRATION (DRYPIPE) FOR STEERING HYDRAULIC LINES WATERTIGHT(IN ENGINEROOM OR AFTERSTEERING SIDE).
Condition: Unknown
Due 2 March 1994
Resolved 2 March 1994
Electrical
Issued 2 March 1994 Resolved
PROPERLY WIRE MICROWAVE OUTLET ON STBD SIDE BULKHEAD IN GALLEY.
Condition: Unknown
Due 2 March 1994
Resolved 2 March 1994
Lifesaving
Issued 2 March 1994 Resolved
PROVIDE LESS THAN 100 PSI/LESS THAN 200 DEGREES PRESSURE TEMPERATURE RELIEFVALVE FOR HOT WATER HEATER.
Condition: Unknown
Due 2 March 1994
Resolved 2 March 1994
Fire Fighting
Issued 19 October 1992 Resolved
RECONFIGURE THE PORT MAIN DECK FIRE HYDRANT FROM VERTICAL TO HORIZONTAL.
Condition: Unknown
Due 19 October 1992
Resolved 19 October 1992
Lifesaving
Issued 19 October 1992 Resolved
REMOVE ALL DIESEL FUEL AND WASTE OIL FROM THE FORWARD VOID SPACE (AFT OF FOREPEAK VOID), CLEAN SPACE AND PROVIDE MARINE CHEMIST CERTIFICATION THAT VOID IS GAS-FREE, PRIOR TO DEPARTURE FROM FREEPORT, TEXAS._x001C_ _x001C_
Condition: Unknown
Due 19 October 1992
Resolved 19 October 1992
Documentation
Issued 19 October 1992 Resolved
PROVIDE FCC MARINE OPERATOR'S PERMIT. _x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 19 October 1992
Resolved 19 October 1992
Navigation
Issued 19 October 1992 Resolved
PROVIDE SIDEBAND RADIO IN ACCORDANCE WITH FCC CERTIFICATE PRIOR TO OPERATIONS OFFSHORE._x001C_
Condition: Unknown
Due 19 October 1992
Resolved 19 October 1992
Fire Fighting
Issued 19 October 1992 Resolved
REPAIR OR REPLACE THE FIRE PUMP DISCHARGE GAUGE AND PROVE PROPER OPERATION TO 60 PSI._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 19 October 1992
Resolved 19 October 1992
Documentation
Issued 19 October 1992 Resolved
PROVIDE WASTE MANAGEMENT PLANS. (33 CFR 151.57)_x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 19 October 1992
Resolved 19 October 1992
Fire Fighting
Issued 19 October 1992 Resolved
RECONFIGURE THE PORT MAIN DECK FIRE HYDRANT FROM VERTICAL TO HORIZONTAL._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 19 October 1992
Resolved 19 October 1992
Documentation
Issued 19 October 1992 Resolved
PROVIDE LEGIBLE CERTIFICATE OF DOCUMENTATION._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 19 October 1992
Resolved 19 October 1992
Electrical
Issued 19 October 1992 Resolved
PRODIDE PROPER BASES FOR ELECTRIC LIGHT FIXTURES IN SHOWER AND FROWARD MAINDECK AFT OF ANCHOR WINDLASS._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 19 October 1992
Resolved 19 October 1992
Construction/Loadline
Issued 19 October 1992 Resolved
REMOVE WASTE ENGINE OIL (30 GALLONS) FROM MACHINERY SPACE BILGES PRIOR TO DEPARTURE FROM PALACIOS, TEXAS._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 20 October 1992
Resolved 21 October 1992
Deck/Cargo
Issued 19 October 1992 Resolved
RELOCATE OR REMOVE THE EQUIPMENT AND CARGO FROM THE MAIN DECK ABOVE THE LAZARETTE SPACE PRIOR TO DEPARTURE FROM PALACIOS, TEXAS. _x001C_ _x001C_
Condition: Unknown
Due 20 October 1992
Resolved 21 October 1992
Fire Fighting
Issued 30 March 1992 Resolved
MAKE PERMANENT REPAIRS TO PIN HOLE LEAK IN FIRE MAIN PIPING IN ENG ROOM.
Condition: Unknown
Due 30 March 1992
Resolved 30 March 1992
Navigation
Issued 25 March 1991 Resolved
INSTALL COTTER PINS IN STEERING GEAR PINS ON PORT AND STARBOARD SIDES.
Condition: Unknown
Due 25 March 1991
Resolved 25 March 1991
Engineering
Issued 25 March 1991 Resolved
PROVE PROPER OPERATION OF REMOTE SHUTDOWN FOR FUEL TRANSFER PUMP.
Condition: Unknown
Due 25 March 1991
Resolved 25 March 1991
Engineering
Issued 25 March 1991 Resolved
PROVIDE FUEL TRANSFER HOSE FOR COAST GUARD INSPECTION.
Condition: Unknown
Due 25 March 1991
Resolved 25 March 1991
Documentation
Issued 25 March 1991 Resolved
PROVIDE PROOF OF RADIOTELEPHONE CERTIFICATE ISSUED BY FCC.
Condition: Unknown
Due 25 March 1991
Resolved 25 March 1991
Engineering
Issued 25 March 1991 Resolved
PROVE PROPER OPERATION OF NUMBER TWO PRESSURE RELIEF VALVE.
Condition: Unknown
Due 25 March 1991
Resolved 25 March 1991
Construction/Loadline
Issued 20 February 1991 Resolved
RENEW STERN DECK AREA AS DETERMINED BY GAUGINGS AND PREPARE FOR INSPECTION TO THE SATISFACTION OF THE LOCAL OCMI.
Condition: Unknown
Due 20 February 1991
Resolved 20 February 1991
Accommodation/Occupational Safety
Issued 22 July 1988 Resolved
PROVIDE EXHAUST VENTILATION ORIGINATING FROM BILGE AREA; FOR MACHINERY SPACE.
Condition: Unknown
Due 22 July 1988
Resolved 22 July 1988
Lifesaving
Issued 22 July 1988 Resolved
PROVIDE SEA PAINTER FOR LIFEFLOATS (WITH WEAK LINK).
Condition: Unknown
Due 22 July 1988
Resolved 22 July 1988

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.