Records from 1997 to 2009. Most recent: inspection, 29 April 2009.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 19
29 April 2009
Deficiency Check · Annual Inspection
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3465491
23 April 2008
Deficiency Check · Annual Inspection
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3179466
18 January 2008
Type not recorded
No type recorded · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3132928
8 May 2007
Deficiency Check
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2940467
17 April 2007
Annual Inspection
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2916835
22 January 2007
Hull Examination
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2860135
7 March 2006
Annual Inspection
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2597474
18 April 2005
COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2318877
2 June 2004
Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2101423
12 April 2004
Annual Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2000352
21 April 2003
Annual Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1942642
22 April 2002
Annual Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1619956
14 March 2002
Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1494123
13 June 2001
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 185415
16 April 2001
Deficiency Check · Annual Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1065612
28 April 2000
Deficiency Check · COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1052684
15 April 1999
Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1384182
20 April 1998
Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 789680
22 April 1997
Initial Certification · Hull Examination · Initial Construction-Excluding Oversight · Plan Review "T" Boat · Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1092241
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 29 April 2009
Resolved
Update first aid kit IAW 46 CFR 184.70
Due 29 May 2009
Resolved 8 May 2009
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 23 April 2008
Resolved
Update First Aid Kit
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 April 2008
Operations/Management › Drug and Alcohol Testing › MIS Submission
Issued 18 January 2008
Resolved
Random pool element missing.
Action required: 705 - Other - as specified
Due 18 January 2008
Resolved 18 January 2008
Resolution: New, updated report sent.
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 18 January 2008
Resolved
MIS display not posted.
Action required: 705 - Other - as specified
Due 18 January 2008
Resolved 18 January 2008
Resolution: Display posted.
Lifesaving › Lifebuoys › Serviceable
Issued 17 April 2007
Resolved
Replace lifering buoy.
Due 30 April 2007
Resolved 25 May 2007
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 17 April 2007
Resolved
Replace lifering buoy waterlight with new line three to six feet in length.
Due 30 April 2007
Resolved 25 May 2007
Fire Fighting › Fixed Gas Fire Extinguishing System
Issued 12 April 2004
Resolved
Make blowers for engine compartment shut down during fixed fire fighting system discharge. 46 CFR 182.460(d). Correct to the satisfaction of the attending marine inspector. LEGACY COMPONENT DESC: Operating Controls
Condition: Improper Installation
Due 13 June 2004
Resolved 2 June 2004
Resolution: Corrected.
Lifesaving
Issued 16 April 2001
Resolved
Provide clips for life ring waterlight and permanently un-tie life ring line from vessel.
Condition: Unknown
Due 14 May 2001
Resolved 15 June 2001
Lifesaving
Issued 16 April 2001
Resolved
Provide man overboard and fire drill records or conduct drills for attending CG inspector.
Condition: Unknown
Due 14 May 2001
Resolved 15 June 2001
Construction/Loadline
Issued 28 April 2000
Resolved
PROVIDE DOUBLE CLAMPS FOR ALL THRU HULL PENETRATIONS UP TO SEA VALVES.
Condition: Unknown
Due 1 June 2000
Resolved 30 July 2000
Lifesaving
Issued 28 April 2000
Resolved
PROVIDE OPERATIONAL TESTING AND FIRE/MAN OVERBOARD DRILLS TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR
Condition: Unknown
Due 1 June 2000
Resolved 30 July 2000
Documentation
Issued 22 April 1997
Resolved
PROVIDE COPY OF CERTIFICATE OF DOCUMENTATION.
Condition: Unknown
Due 13 June 1997
Resolved 13 June 1997
Documentation
Issued 22 April 1997
Resolved
POST STABILITY LETTER ON BOARD UPON RECEIPT.
Condition: Unknown
Due 13 June 1997
Resolved 13 June 1997
Construction/Loadline
Issued 22 April 1997
Resolved
PROVIDE HAND-OPERATED PORTABLE 10 GPM BILGE PUMP.
Condition: Unknown
Due 13 June 1997
Resolved 13 June 1997