Inspection history · 28
28 May 2026
Annual Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 8382886
13 November 2025
Examination of Repairs · Plan Review "T" Boat · Damage Survey
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 8268444
27 March 2025
COI Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 8101111
6 March 2025
Drydock Exam · Internal Structural Exam · Hull Examination · Examination of Repairs
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 8087508
9 April 2024
Annual Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 7892502
18 March 2024
Damage Survey · Examination of Repairs
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7881155
11 May 2023
Annual Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 7686149
19 April 2023
In-Service Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 7671769
15 February 2023
Hull Examination · Examination of Repairs · Internal Structural Exam
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7637005
15 September 2022
Annual Inspection · DAPI Audit
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 7562016
18 February 2022
Administrative Inspection
Administrative · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7398605
26 January 2022
Examination of Repairs · Administrative Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 7386484
1 September 2021
Deficiency Check · Examination of Repairs
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 7302159
27 May 2021
DAPI Audit · Deficiency Check · Annual Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 7193828
6 April 2021
Hull Examination · Internal Structural Exam
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7169500
30 March 2021
Administrative Inspection
Administrative · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 7166794
27 July 2020
DAPI Audit · COI Inspection · Deficiency Check · Examination of Repairs
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 7014864
17 October 2019
Examination of Repairs
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6837167
19 July 2019
Damage Survey · Examination of Repairs
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6755306
21 May 2019
DAPI Audit · Examination of Repairs · Annual Inspection · Deficiency Check
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 6678650
10 April 2019
Examination of Repairs
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 6697827
15 October 2018
Examination of Repairs · Hull Examination · Internal Structural Exam · Drydock Exam
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6561828
9 May 2018
Annual Inspection · DAPI Audit · Deficiency Check
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 6405973
7 August 2017
DAPI Audit · Annual Inspection · Deficiency Check
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 6233884
3 June 2017
Examination of Repairs · Administrative Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 6168882
31 March 2017
Internal Structural Exam · Hull Examination · Examination of Repairs · Drydock Exam
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6115028
4 December 2016
Examination of Repairs
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 6052814
12 May 2016
Administrative Inspection · DAPI Audit · Annual Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 5875261
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 28 May 2026
Resolved
An adult life jacket must be provided for each person carried on board a vessel.
54 Adult PFDs were removed from service due to wastage.
Replace Adult PFDs with new ones to accommodate all adults. allowed per the COI.
Action required: 10 - Deficiency Rectified
Resolved 28 May 2026
Resolution: Owner had 33 brand new extra PFDs in storage and was able to order the small remaining 21 PFDs while the CG was onboard.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 28 May 2026
Resolved
All vessels must have navigation lights that are in compliance with the applicable sections of the International and Inland Navigation Rules, except that a vessel of more than 19.8 meters (65 feet) in length must also have navigation lights that meet UL 1104, “Standards for Marine Navigation Lights,” or other standard specified by the Commandant.
The vessel's stern light and starboard running light were not operable.
Action required: 10 - Deficiency Rectified
Resolved 28 May 2026
Resolution: New bulbs were provided and changed during the inspection.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 27 March 2025
Resolved
Complete but simple instructions for the operation of a fixed gas fire extinguishing system must be located in a conspicuous place at or near each pull box and stop valve control and in the space where the extinguishing agent cylinders are stored.
Provide operating instructions for CO2 system pull at the operating station under the helm prior to passenger operations
Action required: 705 - Other - as specified
Resolved 27 March 2025
Resolution: Instructions posted at the helm pull station
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 27 March 2025
Resolved
An adult life jacket must be provided for each person carried on board a vessel.
8 Adult PFDs were taken out of service. Provide 8 adult size PFDs.
Action required: 705 - Other - as specified
Resolved 27 March 2025
Resolution: 8 adult type I PFDs provided
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 27 March 2025
Resolved
On a vessel of at least 7.9 meters (26 feet) in length, a visual and audible alarm must be provided at the operating station to indicate a high water level in each of the following normally unmanned space.
Bilge hiigh water alarm light for the lazarette is inoperable.
Action required: 705 - Other - as specified
Due 27 March 2025
Resolved 27 March 2025
Resolution: New light provided and faulty wiring restored
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 9 April 2024
Resolved
A self priming, power driven fire pump must be installed on each vessel of not more than 19.8 meters (65 feet) in length that carries more than 49 passengers.
The vessel's fire pump was not operational at the time of inspection.
Action required: 10 - Deficiency Rectified
Resolved 9 April 2024
Resolution: The fire pump was disassembled and it was found that the impeller was covered in muck from not being used during the off season. Parts were cleaned and reinstalled and the fire pump was tested satisfactorily.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 27 May 2021
Resolved
Vessel required to be equipped with navigational lights. Existing navigational side lights were found with improper bulbs (wattage/size).
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 June 2021
Resolved 9 July 2021
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 27 May 2021
Resolved
Vessels required to be equipped with bilge high water alarms. Existing bilge high water alarms IWO fwd void/lazarette failed to emit an audible alarms when activated/tested.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 June 2021
Resolved 9 July 2021
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 27 May 2021
Resolved
Vessel required to be equipped with a Type I PFD for each person on board. Five of the existing adult Type I PFD's were condemned for unserviceability.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 June 2021
Resolved 9 July 2021
09 - Working and Living Conditions › 092 - Working Conditions › Anchoring devices
Issued 6 April 2021
Resolved
A vessel must be fitted with round tackle and mooring arrangements to safely anchor or moor; the mounting hardware for the structure supporting the forward centerline cleat is deteriorated and must be renewed.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 May 2021
Resolved 1 September 2021
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 6 April 2021
Resolved
Each connection to a conductor must be made within an enclosure; the wire run to the electrical outlet in the stbd overhead of the forward storage compartment has a splice which is not in an enclosure.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 May 2021
Resolved 1 September 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 6 April 2021
Resolved
Materials used in piping systems must meet the requirements of Subpart G and be otherwise acceptable to the OCMI; the bilge pump overboard valve at the port side shell IWO the engine compartment is seized up and not operational.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 May 2021
Resolved 1 September 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 27 July 2020
Resolved
Vessel required to be equipped with two independent means of controlling each propulsion engine. The newly intalled electronic control system failed to restore power to the control head upon loss of power (emergency power).
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 July 2020
Resolution: Attending Inspector(s) verified propulsion engine controls in all modes of operation.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 27 July 2020
Resolved
Vessel shall be capable of dewatering all watertight compartments. Fixed bilge system failed to draw suction from engine room bilges.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 August 2020
Resolution: Attending Inspector(s) verified repairs made to fixed bilge piping IWO engine room suction. Witnessed satisfactory operational test.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 27 July 2020
Resolved
Installed fuses shall be of the cartridge type and be listed by Underwriters Laboratory (UL). Automotive blade style fuses were installed IWO console for 12V system.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 August 2020
Resolved 25 August 2020
Resolution: Attending Inspector(s) verified installation of cartridge style fuse block IWO console.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 27 July 2020
Resolved
Vessel's steering system must be capable of steering vessel at all service speeds. Excessive play noted IWO steering system @ helm. Inspect keyway and install new securing bolt.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 July 2020
Resolution: Attending Inspector verified repairs made to steering wheel/helm shaft.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 27 July 2020
Resolved
Vessel's steering system must be capable of steering vessel at all service speeds. Vessels hydraulic ram assembly is "jumping" while under pressure (air bound).
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 August 2020
Resolved 30 July 2020
Resolution: Attending Inspector verified repairs to hydraulic ram assembly (bleeding of air).
10 - Safety of Navigation › N/A - No Subsystem › Radar
Issued 27 July 2020
Resolved
Vessel required to be equipped with operable radar. Existing radar is inoperable due to faulty data cable between radar and display.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 August 2020
Resolved 25 August 2020
Resolution: Attending Inspector(s) verified replacement of networking cable for vessels radar. Witnessed satisfactory operational test of vessels radar.
02 - Structural Conditions › N/A - No Subsystem › Bulkheads - operational damage
Issued 27 July 2020
Resolved
All accessible parts of the vessels hull shall be examined at each initial and subsequent inspections for certification. Fractured tabbing was noted IWO fwd storeroom/compartment @ fwd. bulkhead.
Action required: 705 - Other - as specified
Due 31 March 2021
Resolved 1 September 2021
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 27 July 2020
Resolved
Vessels life jacket stowage locations are required to be marked with type/qty of PFD's. Existing stowage locations are missing required markings (qty. of PFD's stowed).
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 August 2020
Resolved 25 August 2020
Resolution: Attending Inspector(s) verified renewal of PFD stowage markings.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 27 July 2020
Resolved
Vessel required to be fitted with ventilation closure devices (fixed fire fighting system). Existing ventilation closures do not fully seal (missing gasketing material).
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 August 2020
Resolved 25 August 2020
Resolution: Attending Inspector(s) verified renewal of gasketing IWO ventilation closures for engine room.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 27 July 2020
Resolved
Watertight hatches are required to be marked. Existing main deck watertight hatches are missing required markings (WATERTIGHT HATCH KEEP CLOSED).
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 August 2020
Resolved 25 August 2020
Resolution: Attending Inspector(s) verified markings for main deck watertight hatches.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 27 July 2020
Resolved
Vessel required to be equipped with Type I PFD for each (adult) person on board. Attending Inspector(s) condemned 19 Adult Type I PFD's.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 August 2020
Resolution: Attending Inspector(s) verified the replacement of nineteen (19) adult Type I PFD's.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 27 July 2020
Resolved
Vessel required to be equipped with proper type/qty of visual distress signals for route assigned. Vessel was missing required type/qty. of visual distress signals.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 July 2020
Resolution: Attending Inspector verified carrige of proper type/qty of visual distress signals.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 27 July 2020
Resolved
Vessel required to be fitted with a mast light. Existing mast light is improperly installed (located to far aft).
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 August 2020
Resolved 25 August 2020
Resolution: Attending Inspector(s) verified relocation of fwd mast light and witnessed satisfactory operational test.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 27 July 2020
Resolved
Vessel required to be equipped with independent means of controlling each propellor. Owner/Operator to provide written operating instructions/procdures for newly installed electronic engine control system and reduction gears/transmissions.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 August 2020
Resolved 25 August 2020
Resolution: Attending Inspector(s) verified implementation/posting of operating instructions for vessels electronic propulsion controls.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 17 October 2019
Resolved
Circuit breakers shall be of an approved type (UL 489); the breakers installed with the new propulsion controls are not an approved type.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 28 July 2020
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 19 July 2019
Resolved
Make repairs to hull - STBD side. Damage caused by striking underwater object.
Action required: 705 - Other - as specified
Resolved 26 July 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 19 July 2019
Resolved
Replace STBD propeller and propeller shaft or repair and provide documentation to attending MI.
Action required: 705 - Other - as specified
Resolved 26 July 2019
Resolution: Replaced stbd and port propellers, stbd shaft was repaired/straightened.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 21 May 2019
Resolved
Damge noted to port (bow) gunwale/deck railing. Owner/operator to submit repair proposal to attending Inspector. Damage is well above the waterline and does not impair sea-worthiness of vessel.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 June 2019
Resolved 27 July 2020
Resolution: Temp repairs authorized through 2019 operating season.
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 21 May 2019
Resolved
Vessels name was not marked IWO port/starboard bow. Vessels name is marked along the mid body (port/starboard) for advertisement purposes.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 June 2019
Resolved 28 June 2019
Resolution: Attending Inspector(s) verified hull markings.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 21 May 2019
Resolved
Bilge high water alarm (visual indicator) for aft void was inoperable at time of inspection.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 June 2019
Resolved 31 July 2019
Resolution: Attending Inspector(s) verified operation of bilge high water alarms.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 21 May 2019
Resolved
Electric submersible bilge pump IWO swim platform was inoperable at time of inspection.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 June 2019
Resolved 28 June 2019
Resolution: Attending Inspector(s) verified operation of elec. submersible bilge pump IWO swim platform.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 21 May 2019
Resolved
Main deck longitudinal beam brackets were wasted IWO tank room.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 June 2019
Resolved 28 June 2019
Resolution: Attending Inspector(s) verified renewal of main deck longitudinal beam brackets IWO tank void.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 21 May 2019
Resolved
Fixed CO2 system IWO machinery space was serviced by third party company, however, no service tags were provided for the system.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 June 2019
Resolved 28 June 2019
Resolution: Verified posting of service tags for fixed CO2 system.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 21 May 2019
Resolved
Four adult Type I PFD's were condemned due to age/deterioration/serviceability.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 May 2019
Resolved 28 June 2019
Resolution: Attending Inspector(s) verified renewal of four Type 1 PFD's
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 21 May 2019
Resolved
Renew PFD stowage markings (beneath passenger seating).
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 June 2019
Resolved 28 June 2019
Resolution: Attending Inspector(s) verified renewal of PFD stowage markings.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 21 May 2019
Resolved
Provide double hose clamps IWO electric submersible bilge pump discharge piping (throughout vessel).
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 June 2019
Resolved 28 June 2019
Resolution: Attending Inspector(s) verified installation of hose clamps IWO elec. submersible bilge pumps.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 9 May 2018
Resolved
Vessel not equipped with current/up to date navigational publications (CG Light List, Coast Pilot [name withheld]).
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 June 2018
Resolved 11 July 2018
Resolution: Attending Inspector(s) verified carriage of current/up to date navigational publications for areas transited.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 9 May 2018
Resolved
Portable fire extinguisher not serviced (fwd crew qtrs)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 June 2018
Resolved 11 July 2018
Resolution: Attending Inspector(s) verified servicing of portable fire extinguishers.
Communications › Alarms/Indicators › Bilge Alarm
Issued 9 May 2018
Resolved
Bilge high water alarms were inoperable in the following spaces: tank room (aft), crew qtrs (fwd), machinery space.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 May 2018
Resolved 11 July 2018
Resolution: Attending Inspector(s) performed operational test of bilge high water alarms and verified operation of audible/visual indicators.
Engineering › Steering Gear System › Linkage
Issued 9 May 2018
Resolved
Linkage hardware for steering system (ram to tie bar) was worn/required renewal.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 June 2018
Resolved 11 July 2018
Resolution: Attending Inspector(s) verified repairs made IWO steering tie bar hardware (between ram/tie bar).
Engineering › Steering Gear System › Hydraulic Hose
Issued 9 May 2018
Resolved
Hydraulic hose fittings (supply/return) was wasted/deteriorated IWO lazarette.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 June 2018
Resolved 11 July 2018
Resolution: Attending Inspector(s) verified installation of hydraulic hoses (renewal) for steering gear system IWO lazarette.
Engineering › Bilge Water Management System › Hose
Issued 9 May 2018
Resolved
Flex hoses IWO port main diesel engine bilge pump/piping system were cracked/deteriorated.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 June 2018
Resolved 11 July 2018
Resolution: Attending Inspector(s) verified renewal of flex hoses IWO port & starboard main diesel engine(s) bilge pump piping system.
Engineering › Sea-water System (primary cooling) › Piping
Issued 9 May 2018
Resolved
Flex hoses IWO port & starboard main diesel engine sea chest valves require replacement due to cracking/deterioration.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 June 2018
Resolved 21 May 2019
Resolution: Attending Inspector(s) verified renewal of flexible hose(s).
Electrical › Electric Supply System (service) › Battery Conductor
Issued 9 May 2018
Resolved
Improper installation of conductors for battery charger IWO port machinery space (welding cables).
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 9 July 2018
Resolved 11 July 2018
Resolution: Attending Inspector(s) verified removal of existing welding cable conductors for battery charger and verified (new) installation.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 7 August 2017
Resolved
Missing FCC Safety Radiotelephony Certificate for VHF-FM radio installation.
Action required: 705 - Other - as specified
Due 6 September 2017
Resolved 6 September 2017
Resolution: Verified carriage of current/up to date FCC Radiotelephony Certificate.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Instructions
Issued 7 August 2017
Resolved
Missing local operating instructions for fixed CO2 system (machinery space).
Action required: 705 - Other - as specified
Due 6 September 2017
Resolved 6 September 2017
Resolution: Verified posting of instructions for fixed CO2 system (machinery space).
Communications › Alarms/Indicators › High Water Alarm
Issued 7 August 2017
Resolved
Missing visual indicators for bilge high water alarms.
Action required: 705 - Other - as specified
Due 6 September 2017
Resolved 6 September 2017
Resolution: Performed operational test of bilge high water alarms (all spaces).
Engineering › Bilge Water Management System › Strainer
Issued 7 August 2017
Resolved
Fixed bilge system suction strainers were improperly sized.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 6 September 2017
Resolved 6 September 2017
Resolution: Verified installation of bilge suction strainers in forepeak/lazarette.
Engineering › Bilge Water Management System › Valve
Issued 7 August 2017
Resolved
Thru-hull fittings were not equipped with stop valves (6" above deepest load waterline) (multiple systems).
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 6 September 2017
Resolved 6 September 2017
Resolution: Verified all thru-hull fittings were >6" above deepest load waterline.
Navigation › Piloting/Steering › Marine Charts
Issued 7 August 2017
Resolved
Marine charts for areas transited were not current/up to date.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 September 2017
Resolved 6 September 2017
Resolution: Verified carriage of current/up to date marine charts for areas transited.
Documentation › Markings/Placards › Warning Signs
Issued 7 August 2017
Resolved
Emergency escape routes were not properly marked/identified.
Action required: 705 - Other - as specified
Due 6 September 2017
Resolved 6 September 2017
Resolution: Verified presence/posting of emergency escape markings along the main deck.
Documentation › Markings/Placards › Warning Signs
Issued 7 August 2017
Resolved
Main deck watertight hatches were not properly marked/identified.
Action required: 705 - Other - as specified
Due 6 September 2017
Resolved 6 September 2017
Resolution: Verified presence/posting of watertight hatch markings along the main deck.
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 4 December 2016
Resolved
Port main diesel engine exhaust piping fractured IWO turbo outlet.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 16 December 2016
Resolved 1 February 2017
Resolution: Attending Inspector witnessed final repair of port MDE exhaust piping. Performed operational test of port MDE.