RA 58 is a 1977 tank barge. The Coast Guard has recorded 16 inspections since 1998, most recently in February 2009, along with 14 deficiencies.

Records from 1998 to 2009. Most recent: inspection, 11 February 2009.

Built
1977
Last inspected
11 February 2009
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 17 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.

Inspection record

Last inspected 11 February 2009
Operational controls None recorded without a removal date
Years with a record 11 calendar years (1998–2009)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

454605
Flag
UNITED STATES
Maury page id
psix-454605

Documentation record

Tonnage as PSIX records it143 - Regulatory (Subpart C or D), Gross Ton
74 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 16

11 February 2009 Annual Inspection · MTSA Verification
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3413336
26 March 2008 Examination of Repairs
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3172408
4 March 2008 Deficiency Check · Internal Structural Exam · Drydock Exam · Cargo Tank Internal
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3158075
19 February 2008 Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3149566
10 October 2006 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2797699
4 April 2006 Annual Inspection · MTSA Verification
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2616316
23 February 2005 COI Inspection · MTSA Verification
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2295281
23 February 2005 MTSA Verification
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2315819
23 April 2004 Annual Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2054743
28 March 2003 Periodic Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1770856
28 May 2002 Annual Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1622085
15 March 2001 Annual Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1059772
29 March 2000 Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1047560
15 March 2000 COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 816630
19 March 1999 Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 807631
16 March 1998 Initial Certification · Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1108386

Deficiency record · 14

Engineering › Lubricating Oil Storage/Transfer System › Gauge
Issued 11 February 2009 Resolved
Discharge pressure gauge not reading correctly. Prove proper operation of the discharge pressure gauge on cargo transfer pump prior to operate the pump.
Action required: 705 - Other - as specified
Due 13 February 2009
Resolved 12 February 2009
Resolution: New working gauge installed and proved proper operation.
Electrical › Electric Supply System (service) › Battery Installation
Issued 4 March 2008 Resolved
Provide blocking for batteries, in deck box, to prevent shifting.
Action required: 705 - Other - as specified
Due 20 April 2008
Resolved 9 April 2008
Construction/Loadline › Structures › Deck Plating
Issued 4 March 2008 Resolved
Remove scal and recoat deck IWO aft deck and door in deck house.
Action required: 705 - Other - as specified
Due 20 April 2008
Resolved 9 April 2008
Construction/Loadline › Hull › Bottom Plating
Issued 4 March 2008 Resolved
Make repairs to bottom plating where indicated, four inserts (18"x18", 7'x4', 28"x38", and 32"x91") to be croped and renewed.
Action required: 17 - Rectify deficiencies prior to departure
Due 11 March 2008
Resolved 19 March 2008
Resolution: Repairs completed and air test sat.
Construction/Loadline › Hull › Bottom Plating
Issued 4 March 2008 Resolved
Renew as orginal 100 feet of seam weld as indicated by CG Marine Inspector.
Action required: 17 - Rectify deficiencies prior to departure
Due 11 March 2008
Resolved 19 March 2008
Resolution: repairs complete and air tested sat.
Construction/Loadline › Markings › Draft Marks/Indicating System
Issued 4 March 2008 Resolved
Renew draft marks at port and starboard, bow and stern as required.
Action required: 17 - Rectify deficiencies prior to departure
Due 20 March 2008
Resolved 19 March 2008
Resolution: As required markings provided.
Documentation › Manuals/Policy Documentation › Transfer Procedures
Issued 4 April 2006 Resolved
Update phone numbers in the transfer procedures
Action required: 705 - Other - as specified
Due 18 April 2006
Resolved 19 April 2006
Resolution: Received phone call stating that the numbers were update. I will verify during an inspection on the swob-056 tomorrow
Navigation › Collision/Grounding Avoidance
Issued 23 April 2004 Resolved
Paint nav light backing fixture with flat black paint. LEGACY COMPONENT DESC: Navigation Lights
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 April 2004
Resolution: Verified item corrected.
Deck/Cargo › Cargo Transfer/Lightering (liquid)
Issued 23 April 2004 Resolved
Inspect cargo pump engine and test emergency shut down. LEGACY COMPONENT DESC: Cargo Pump
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 April 2004
Resolution: Inspected and tested installed cargo pump, all sat. Cleared CG-835
Deck/Cargo › Cargo Transfer/Lightering (liquid)
Issued 23 April 2004 Resolved
Repair cover plate on emergency shut down switch. LEGACY COMPONENT DESC: Emergency Shut-down
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 April 2004
Resolution: Inspected installed emergency shut down cover plate, all sat. Cleared CG-835.
Construction/Loadline › Hull › Hull Plating
Issued 28 March 2003 Resolved
Prior to conducting cargo operations. Provide this office with a repair proposal for crack at port aft rake at bilge knuckle. Prior to final fit-up, require Marine Inspector to inspect back gouge and conduct water test.
Condition: Unknown
Due 28 March 2003
Resolved 31 March 2003
Resolution: Inspected back gouge and conducted water test on new fit-up. All sat. Barge allowed to conduct cargo operations.
Electrical › Electrical Distribution System (service)
Issued 28 May 2002 Resolved
Remove "extension cord" cable in deck shed and replace with approved shipboard cable. LEGACY COMPONENT DESC: Cable
Due 28 May 2002
Resolved 6 June 2002
Resolution: Proper shipboard cable in place at junction box in deck shed.
Deck/Cargo › Cargo Transfer/Lightering (liquid)
Issued 28 May 2002 Resolved
Provide nuts and bolts for deck connection flange to cargo piping. LEGACY COMPONENT DESC: mainfold flange
Condition: Improper Installation
Due 23 June 2002
Resolved 6 June 2002
Resolution: Proper cargo piping flange provided.
Deck/Cargo › Cargo Transfer/Lightering (liquid)
Issued 28 May 2002 Resolved
Provide blank flange for cargo pipe (old) deck penetration, port side aft. LEGACY COMPONENT DESC: Piping
Due 23 June 2002
Resolved 6 June 2002
Resolution: Blank flange for cargo pipe (old), port side aft properly provided.