← All vessels
ALL SWELL
Passenger (Inspected) · Passenger Ship class · Built 1990s · USCG Southwest District (CGD-SW) · Other hulls named ALL SWELL
ALL SWELL is a 1997 passenger vessel (inspected). The Coast Guard has recorded 32 inspections since 1997, most recently in April 2026, along with 44 deficiencies and 2 casualty investigations between 2014 and 2026.
Records from 1997 to 2026. Most recent: inspection, 30 April 2026.
- Built
- 1997
- Last inspected
- 30 April 2026
- Documentation
- Valid · documentation file of 10 September 2026
- Deficiencies
- 44 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
- Casualties
- 2 investigations · 2014–2026
Identity
1052208
WDL5038
454609
Flag
UNITED STATES
368137290
Maury page id
psix-454609
Inspections, by type
…with no type recorded6
Years with a record
16 calendar years (1997–2026)
The 32 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.
Documentation record
Registered dimensions (L × B × D)31.0 ft × 8.5 ft × 3.8 ft
Registered tonnagegross 6 / net 5
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderCOMMERCIAL WATER SPORTS · LAKE HAVASU CITY, AZ, UNITED STATES · built 1997
Hull materialFRP (Fiberglass)
PropulsionDiesel Outdrive
Hull shapeShip
Hull configurationMonohull
Hailing portDANA POINT, CA
Trade endorsementsCoastwise, unrestricted, Recreational
DocumentationValid · issued 6 May 2026 · expires 31 May 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it6 - Simplified, Gross Ton
5 - Simplified, Net Ton
5 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
WDL5038MMSI 368137290 · active · compulsorily equipped · granted 13 March 2020, expires 13 March 2030
WDH5274MMSI 367626280 · expired · compulsorily equipped · granted 10 June 2014, cancelled 10 August 2024
WDH4803MMSI 367621540 · expired · compulsorily equipped · granted 15 May 2014, cancelled 20 July 2024
WCX4451MMSI not assigned · expired · compulsorily equipped · granted 2 May 1997, cancelled 8 July 2007 · licensed under a name not among this hull’s recorded names (not shown)
WCX3860MMSI not assigned · expired · compulsorily equipped · granted 8 April 1997, cancelled 10 June 2007 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 32
30 April 2026
Deficiency Check · Vessel Attendance · Administrative Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8358920
30 April 2026
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8358970
17 March 2026
Vessel Attendance · Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8311769
14 April 2025
COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8093350
23 April 2024
Annual Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7862908
21 March 2024
Examination of Repairs · Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7862912
31 May 2023
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7659721
9 November 2022
Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7623556
8 June 2022
Deficiency Check · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7457675
22 March 2022
Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7416323
5 April 2021
Annual Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7168829
6 March 2020
Deficiency Check · Re-Inspection · Plan Review "T" Boat · COI Inspection · Administrative Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6921904
14 May 2019
DAPI Audit · Deficiency Check · COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6663751
21 September 2018
Annual Inspection · DAPI Audit
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6548340
26 April 2018
Internal Structural Exam · Drydock Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6472792
26 June 2017
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6198739
26 April 2017
DAPI Audit
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6136253
29 April 2016
Annual Inspection · DAPI Audit · Drydock Exam · Internal Structural Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 5961892
24 August 2015
Internal Structural Exam · DAPI Audit · Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 5226990
26 August 2014
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 4966234
9 August 2014
Type not recorded
No type recorded · Station Ocean City · USCG East District (CGD-E) · Activity 4950380
9 August 2014
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 4951274
5 August 2014
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 4953682
13 June 2014
COI Inspection · DAPI Audit
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 4887261
21 May 2014
Simplified Stability Test · Internal Structural Exam · COI Inspection · Hull Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4864130
13 May 1999
Administrative
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 796285
23 February 1998
COI Inspection · MARPOL Annex V Examination · Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1115574
20 October 1997
Administrative
Administrative · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 776658
13 August 1997
Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1118713
13 August 1997
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1388338
4 May 1997
Initial Certification
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1441229
26 March 1997
Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1458408
Deficiency record · 44
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 30 April 2026
Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury. During voyage on 30APR2026, vessel experienced a loss of propulsion due to a broken shifting cable. Prior to operations, verify repairs and complete sea trial with the attending marine inspector.
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 23 April 2024
Resolved
Vessel must have coastwise endorsement on Certificate of Documentation to conduct Coastwise Trade.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 23 April 2024
Resolved
Vessel must have at least (3) 2.5 gal buckets with an attached lanyard, labeled "Fire Bucket" in lieu of a fire pump.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 21 March 2024
Resolved
Provision must be made for closing all supply duct cowls or scoops and exhaust duct discharge openings for a space protected by a fixed gas extinguishing system. All closure devices must be readily available and mounted in the vicinity of the vent. Ventilation closure devices for engine room were found unable to be secured for all 4 vents. Repair/replace closure device securing points and demonstrate proper operation.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 8 June 2022
Resolved
As appropriate for the intended voyage a vessel must carry adequate and up to date chart. Vessel could not provide proof of up to date charts.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 8 June 2022
Resolved
Repairs or alterations to the hull, machinery or equipment that affect the safety of the vessel must not be made without the approval of the cognizant OCMI. Vessel has seven cracks on pipes that support the bimini top. Within 14 days prepare and provide a repair plan. Repairs must be completed by 30OCT2022.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 5 April 2021
Resolved
A power driven vessel not required to have a fire pump must have at least (03) 2-1/2 gallon fire buckets. Vessel has (01).
Provide an additional (02) Fire Buckets with laynards and markings.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 5 April 2021
Resolved
Remote fuel shutoff stations must be marked with 1 inch letters. Missing label.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 5 April 2021
Resolved
Each battery must be secured and protected against shifting and free from exposure to water. Battery boxes not secured and missing covers.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 14 May 2019
Resolved
A space containing propulsion machinery must be equipped with a fixed gas fire extinguishing system. Vessels fire fighting system was not installed or serviced.
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 14 May 2019
Resolved
Each disposable hydrostatic release unit must be marked with an expiration date of 2 years after installation. Vessel had expired hydro release unit for Epirb.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 14 May 2019
Resolved
Vessel must carry first-aid kit approved IAW 46CFR160.041. Vessels first aid kit had missing and expired contents.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 21 September 2018
Resolved
Prove proper operation of machinery space fixed fire extinguishing system.
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 21 September 2018
Resolved
Provide valid Certificate of Documentation.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 21 September 2018
Resolved
Prove proper operation of high bilge water level alarm for machinery space.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 21 September 2018
Resolved
Renew (04) cracked hatches on main deck. Previous repair attempts have failed. Time to renew.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 21 September 2018
Resolved
Provide Retro-reflective tape on Life Ring Buoy.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 21 September 2018
Resolved
Renew expired EPIRB hydrostatic release.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 21 September 2018
Resolved
Conduct satisfactory man overboard, and fire drills.
Fire Fighting › Fire Bucket › Availability
Issued 26 June 2017
Resolved
Provide (03) fire buckets w/proper label.
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 26 June 2017
Resolved
Prior to carrying passengers, properly label child life jacket storage box.
Lifesaving › Visual Distress Signals (General) › Expired
Issued 26 June 2017
Resolved
rior to carrying passengers, Renew expired flares.
Communications › Alarms/Indicators › Bilge Alarm
Issued 26 June 2017
Resolved
Repair/Renew inoperative engine compartment bilge alarm.
Deck/Cargo › Holds/Tanks › Hatch
Issued 26 June 2017
Resolved
Renew or repair cracked hatch on main deck forward.
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 14 June 2016
Resolved
Provide correct labels for child life jacket storage areas.
Communications › Radio Communications › EPIRB
Issued 29 April 2016
Resolved
Renew EPIRB registration with FCC.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 29 April 2016
Resolved
Re-label life ring buoy with vessel name.
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 29 April 2016
Resolved
Provide 6 add'l Type I adult life jackets to meet number on COI. Vessel retsticted to 24 POB until provided.
Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 24 August 2015
Resolved
Provide one (01) portable light iaw 46CFR183.430
Fire Fighting › Fire Bucket › Quantity
Issued 24 August 2015
Resolved
Provide two (02) fire buckets, labeled "Fire Buckets", with lanyards.
Operations/Management › Drills/Instruction › Not Conducted
Issued 21 May 2014
Resolved
Conduct man overboard and abandon ship drills in presence of Marine Inspector per 46 CFR 184.420.
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 21 May 2014
Resolved
Provide navigational charts and publications for area of operation per 46 CFR 184.420
Lifesaving › Lifejacket/PFD (Type I) › Marking
Issued 21 May 2014
Resolved
completely blank off old name on lifejackets per 46 CFR 185.604
Construction/Loadline › Markings › Vessel Name/Home Port
Issued 21 May 2014
Resolved
Ensure name on vsl bow is visible per 46 CFR 67
Lifesaving
Issued 13 August 1997
Resolved
PROVIDE AND POST PLACARDS FOR DONNING LIFE JACKETS.
Fire Fighting
Issued 13 August 1997
Resolved
PROVIDE MANUAL OR AUTOMATIC VENT CLOSURE IN WAY OF MACHINERY SPACE NATURAL VENTS.
Documentation
Issued 13 August 1997
Resolved
REMAIN WITHIN 1000' FROM SHORE UNTIL PROOF OF FCC SAFETY RADIOTELEPHONY CERTIFICATE IS PROVIDED.
Fire Fighting
Issued 4 May 1997
Resolved
PROVE PROPER OPERATION OF VESSEL'S FIXED FIRE EXTINGUISHING SYSTEM TO THE SATISFACTION OF ATTENDING COGNIZANT COAST GUARD MARINE INSPECTOR, PRIOR TO CARRYING PASSENGERS.
Lifesaving
Issued 4 May 1997
Resolved
PROVIDE A CG APPROVED FIRST AID KIT OR EQUIVALENT KIT IAW 46 CFR 184.710.
Lifesaving
Issued 4 May 1997
Resolved
PROVIDE LIFE JACKET PLACARDS IAW 46 CFR 185.516.
Documentation
Issued 4 May 1997
Resolved
PROVIDE PROOF OF COMPLIANCE WITH THE DRUG TESTING PROGRAM REGULATIONS.
Engineering
Issued 4 May 1997
Resolved
PROVE PROPER OPERATION OF MAIN PROPULSION ENGINE.
Documentation
Issued 4 May 1997
Resolved
PROVIDE PROPER MANNING AND CONDUCT DRILLS TO THE SATISFACTION OF COGNIZANT CG MARINE INSPECTOR PRIOR TO CARRYING PASSENGER.
Fire Fighting
Issued 4 May 1997
Resolved
PROVIDE MANUAL OR AUTOMATIC VENT CLOSURE IN WAY OF MACHINERY SPACE NATURAL VENTS.
Casualty record · 2
9 August 2014Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 2 injured · activity 4951274
30 April 2026Routine · role: Involved in a Marine Casualty · activity 8358970
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.