MAURY USCG vessel records Sign in
← All vessels

CAPE BANKS

CAPE BANKS is a 1997 tank ship. The Coast Guard has recorded 25 inspections since 1997, most recently in November 2010, along with 10 deficiencies and 4 operational controls.

Records from 1997 to 2010. Most recent: inspection, 12 November 2010.

Built
1997
Last inspected
12 November 2010
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9081382 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
454740
Flag
GERMANY
—
Maury page id
psix-454740

Inspections, by type

…with no type recorded16
Years with a record 10 calendar years (1997–2010)
The 25 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 16 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it21162 - Simplified, Gross Ton
21162 - Convention (Subpart B), Gross Ton
10590 - Simplified, Net Ton
10590 - Convention (Subpart B), Net Ton
43762 - Displacement, Ton
33539 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 25

12 November 2010 COC-CHEM Renew · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3889348
7 November 2007 ISPS II Exam · Ballast Water Examination · PII Safety Exam · MARPOL Annex I Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3094742
21 October 2005 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2521748
17 October 2005 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2516022
12 September 2005 Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2490273
6 April 2005 MARPOL Annex II Examination · ISPS II Exam · COC-CHEM Renew · MARPOL Annex I Examination · MARPOL Annex V Examination · Ballast Water Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2327458
6 April 2005 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2327780
5 April 2005 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2327359
8 October 2003 Certificate of Compliance
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1923650
21 April 2003 Type not recorded
No type recorded · USCGC WASHINGTON (WPB 1331) · USCG Oceania District (CGD-O) · Activity 1779883
15 January 2002 Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1478772
23 May 2001 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 290738
23 May 2001 Letter of Compliance (Initial/Renewal)
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1066828
18 May 2000 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1051153
16 May 2000 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 277919
8 September 1999 Type not recorded
No type recorded · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 432490
1 May 1999 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 428214
1 May 1999 Letter of Compliance (Initial/Renewal)
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 813189
3 February 1999 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 646881
1 February 1999 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 449855
28 May 1998 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 139762
15 May 1998 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 415917
15 May 1998 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 791906
21 March 1997 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 401958
21 March 1997 Letter of Compliance (Initial/Renewal)
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1097352

Deficiency record · 10

Navigation › Electronic Positioning › GPS/DGPS Receiver
Issued 6 April 2005 Resolved
Vessel's AIS is not functioning properly. Vessel must have AIS repaired and provide a report from certified technician.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 April 2005
Resolution: Recieved via fax a technicians repotr attesting to the repair of the navigation equipment.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 6 April 2005 Resolved
Cracks found in the support bracket for the starboard gangway upper platform, make repairers to the satisfaction of the class society.
Action required: 705 - Other - as specified
Due 6 May 2005
Resolved 12 September 2005
Resolution: Support bracket was observed to be in satisfactory condition and had fresh welds.
Pollution Prevention/Response › Prevention Equipment › Cargo Monitor/Control System
Issued 6 April 2005 Resolved
Replace the ink cartridge for the Oil Discharge Content Monitor Equipment (ODME); presently the print out is not readable.
Action required: 705 - Other - as specified
Due 6 May 2005
Resolved 12 September 2005
Resolution: ODME was observed to be in compliance and had a print out that was readable.
Fire Fighting › Fixed Fire Detection System › Arrangement
Issued 6 April 2005 Resolved
Audible fire alarm not working in engine room, prove that the audible alarm works in the engine room.
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 April 2005
Resolved 6 April 2005
Resolution: Alarm repaired while onboard.
Lifesaving › Launching Appliances › Falls
Issued 6 April 2005 Resolved
Limit switch for rescue boat has been removed, reinstall limit switch to the satisfaction of the class surveyor.
Action required: 705 - Other - as specified
Due 12 September 2005
Resolved 12 September 2005
Resolution: Limit switch on starboard side lifeboat davit was observed to be in compliance. New Safety Construction Certificate was issued to the vessle in drydock by Class Society.
Operations/Management › Port and Waterways Safety › Notice of Arrival, General
Issued 6 April 2005 Resolved
Master provided the in-corrected Company Security Officer (CSO) on the Advance Notice of Arrival. Master instructed on the importance of providing the correct information.
Action required: 705 - Other - as specified
Due 6 April 2005
Resolved 6 April 2005
Deck/Cargo
Issued 23 May 2001 Resolved
Prior to entering next US port provide report attesting to the #5 starboarddeepwell pump proper operation. SOLAS Chap.1, Regulation 11 (b).
Condition: Unknown
Action required: 15 - Rectify deficiencies by next port
Due 28 June 2001
Resolved 15 January 2002
Resolution: RECEIVED CLASS REPORT STATING PROPER OPERATION OF #5 STARBOARD DEEPWELL PUMP. CLEARED DEFICIENCY.
Navigation
Issued 1 May 1999 Resolved
Ensure vessel has a copy of the local Light List, Prior to next U.S. port from foriegn. 33 C.F.R. 164.33(a)(2)(ii).
Condition: Unknown
Due 9 September 1999
Resolved 9 September 1999
Accommodation/Occupational Safety
Issued 15 May 1998 Resolved
VESSELS MSD WAS NOT LABLED AS AN APPROVED TYPE.
Condition: Unknown
Due 18 May 1998
Resolved 18 May 1998
Deck/Cargo
Issued 15 May 1998 Resolved
VESSELS INERT GAS SYSTEM WAS NOT FUNCTIONING. REQUIRED CLASS SOCIETY SURVEY THAT SYSTEM FUNCTIONED, AND THAT ALL CARGO HOLDS WERE BELOW 8% OXYGEN.
Condition: Unknown
Due 18 May 1998
Resolved 18 May 1998

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.