PACIFIC ARROW is a 1967 passenger vessel (inspected). The Coast Guard has recorded 70 inspections since 1982, most recently in June 2026, along with 130 deficiencies and 3 casualty investigations between 2007 and 2016.

Records from 1982 to 2026. Most recent: inspection, 1 June 2026.

Built
1967
Last inspected
1 June 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDI7251
Flag
UNITED STATES
369083000
Maury page id
psix-45476

Inspections, by type

…with no type recorded10
Years with a record 40 calendar years (1982–2026)
The 70 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)62.0 ft × 15.5 ft × 8.0 ft
Registered tonnagegross 47 / net 32
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderBREAUX'S BAY CRAFT INC · LOREAUVILLE, LA, UNITED STATES · built 1967
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portPORT ANGELES, WA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 12 June 2026 · expires 31 July 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it47 - Regulatory (Subpart C or D), Gross Ton
32 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDI7251MMSI 369083000 · active · compulsorily equipped · granted 18 March 2026, expires 12 April 2036
WDD5196MMSI 367154960 · expired · compulsorily equipped · granted 12 December 2006, cancelled 11 February 2017
WAX4416MMSI not assigned · expired · compulsorily equipped · granted 23 May 1996, cancelled 23 September 2006 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 2

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

MISS ANGELA KAY Commercial Fishing Vessel · MISLE 185407 · 12 July 2007 · activity 3000967MISS GERALINE Commercial Fishing Vessel · MISLE 482449 · 12 July 2007 · activity 3000967

Inspection history · 70

1 June 2026 COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8385927
27 April 2026 Drydock Exam · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8356926
8 October 2025 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8249399
16 May 2025 Simplified Stability Test · Inclining Experiment
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8138076
19 March 2025 Examination of Repairs
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8096600
8 October 2024 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8213028
28 March 2024 Internal Structural Exam · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7886659
6 October 2023 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7804688
4 October 2022 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7571462
29 March 2022 Drydock Exam · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7421062
8 July 2021 COI Inspection · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7232885
8 October 2020 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7233179
17 March 2020 Drydock Exam · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6927727
3 October 2019 Annual Inspection · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6822178
11 October 2018 Annual Inspection · DAPI Audit
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6559627
9 March 2018 Internal Structural Exam · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6366185
23 February 2018 Administrative Inspection
Administrative · Navigation Center · Activity 6360495
6 October 2017 Internal Structural Exam · Annual Inspection · DAPI Audit
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6282870
21 December 2016 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6063634
22 September 2016 Administrative Inspection · Simplified Stability Test
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6006577
14 July 2016 COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5941494
30 November 2015 Drydock Exam · Simplified Stability Test · Internal Structural Exam · Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5771052
23 November 2015 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5768912
13 June 2014 Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4887947
15 September 2011 Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4146134
4 November 2010 COI Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3880788
10 February 2010 Internal Structural Exam · Hull Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3626419
11 February 2009 Annual Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3398504
17 March 2008 Deficiency Check · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3164807
13 February 2008 Internal Structural Exam · Hull Examination · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3132293
12 July 2007 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3000967
6 February 2007 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2867667
8 January 2007 Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2851945
16 November 2005 Hull Examination · COI Inspection · Deficiency Check · Examination of Repairs
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2527960
10 December 2004 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2263216
19 November 2004 Annual Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2244251
23 January 2004 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1991606
22 September 2003 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1913094
22 August 2003 Annual Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1889757
12 August 2003 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1874083
11 June 2003 Administrative Inspection
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1815052
7 January 2002 Hull Examination · Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1466809
9 February 2001 Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1058659
25 October 2000 COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1395566
21 October 1999 Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1369392
4 October 1999 Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1397252
27 April 1999 Hull Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1427671
28 October 1998 Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 804236
30 September 1998 Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1429015
7 November 1997 COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1448976
13 March 1997 Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1107316
27 January 1997 Hull Examination · Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1435855
5 December 1995 Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1355570
17 November 1994 COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1425522
5 October 1994 Hull Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1468321
12 October 1993 Hull Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 828064
27 March 1992 Hull Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1270165
23 October 1991 COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 940226
10 September 1990 Re-Inspection · Hull Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 899810
11 October 1988 COI Inspection · Hull Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1201655
2 March 1987 Drydock Extension
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1005063
1 October 1986 Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1006211
5 August 1985 COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1299515
13 June 1985 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 984567
14 March 1985 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1287204
1 August 1984 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 977379
10 November 1983 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1279926
8 August 1983 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 969583
17 May 1983 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1275589
14 May 1982 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1271260

Deficiency record · 130

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 3 October 2019 Resolved
Individual bilge suction lines must be provided with a check valve at some accessible point in the bilge line. Provide check valve for forepeak bilge line. 46CFR182.25-5(c) (Old-T)
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 November 2019
Resolved 30 October 2019
Resolution: Vessel rep provided photos of installed check valve.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 October 2019 Resolved
Individual wires must be installed with metal supporters spaced not more than 24 inches apart, and in such manner to avoid chafing and other damage. Provide metal supports for wires in port side aft passenger void. 46CFR183.340(b)(4)
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 November 2019
Resolved 30 October 2019
Resolution: Vessel rep provided photo of wire support installation.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 3 October 2019 Resolved
A hatch exposed to the weather must be weathertight. Replace gasket on port engine hatch to make weathertight. Additionally, replace engine room entrance hatch.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 November 2019
Resolved 31 October 2019
Resolution: Vessel rep provided photo of newly installed hatch and gaskets.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 3 October 2019 Resolved
The main steering gear strikes against the metal support at the steering gear. Must provide rudder stops or other means to stop striking structural support. 46CFR182.30-1(a) (Old-T)
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 November 2019
Resolved 31 October 2019
Resolution: Vessel rep provided photos of spacers installed on steering gear which prohibit cross piece from making contact with vertical support.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 11 October 2017 Resolved
First aid kit had multiple expired items. Replace individual items or entire kit. 46CFR184.710
Action required: 705 - Other - as specified
Due 18 October 2017
Resolved 11 October 2017
Resolution: Procured new medical kit and installed on vessel.
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 11 October 2017 Resolved
Vessel only had 49 adult size life jacket on-board. COI authorized carriage of 51 passengers. Vessel limited to carriage of 49 passengers until 51 adult life jackets are provided. 46CFR180.7(a)
Action required: 705 - Other - as specified
Due 18 October 2017
Resolved 11 October 2017
Resolution: Procured 2 new TYPE I PFD's and built them up IAW CFR.
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 4 November 2010 Resolved
Fit exhaust lagging around the water injection ports as required by 46 CFR 182.425.
Due 4 December 2010
Resolved 6 December 2010
Resolution: Exhaust lagging was properly installed.
Electrical › Lighting (service) › Lighting Fixture
Issued 4 November 2010 Resolved
Renew broken lighting fixture located on the port side overhead of the engine room compartment as required by 46 CFR 183.410.
Due 4 December 2010
Resolved 6 December 2010
Resolution: Lighting fixture was repaired as new.
Stability › Watertight Integrity › Weathertight Enclosure
Issued 4 November 2010 Resolved
Renew gasket on both engine room hatch covers as required by 46 CFR 179.360.
Due 4 December 2010
Resolved 6 December 2010
Resolution: Gasket was renewed.
Electrical › Electrical Distribution System (service) › Wiring
Issued 4 November 2010 Resolved
Permanently fix MSD pump located in the mid-body compartment and hard wire as required by 46 CFR 176.800.
Due 4 December 2010
Resolved 6 December 2010
Resolution: Pump was permanently fixed and hard wired as required.
Fire Fighting › Ventilation Systems › Ducts
Issued 4 November 2010 Resolved
Prove operation of 2 aft engine room vent covers as required by 46 CFR 182.465.
Due 4 December 2010
Resolved 6 December 2010
Resolution: Guides that hold vent covers where repaired so that the covers may properly slide into place.
Engineering › Lubricating Oil Service System › Filter
Issued 4 November 2010 Resolved
Make repairs to fix leak on lube oil filter housing on port MDE as required by 46 CFR 176.800.
Due 4 December 2010
Resolved 6 December 2010
Resolution: Seal in filter was replaced.
Lifesaving › Rescue Boat › Embarkation/Disembarkation Capabilities
Issued 4 November 2010 Resolved
Provide rescue platform on board as required by 46 CFR 180.210.
Due 4 December 2010
Resolved 6 December 2010
Resolution: Newly constructed platform was provided onboard vessel.
Engineering › Sea-water System (primary cooling) › Valve
Issued 10 February 2010 Resolved
Make all valves ready for inspection.
Action required: 705 - Other - as specified
Resolved 8 March 2010
Resolution: All valves were ready for inspection.
Construction/Loadline › Hull › Hull Plating
Issued 10 February 2010 Resolved
Clean side shell plate, starboard side of mid body compartment in way of severe pitting and delamination.
Action required: 705 - Other - as specified
Resolved 8 March 2010
Resolution: Cleaned side shell plate in way of pitting.
Construction/Loadline › Hull › Girder
Issued 10 February 2010 Resolved
Crop and renew the deteriorated area of top flange on outboard girder port side in mid body compartment.
Action required: 705 - Other - as specified
Resolved 8 March 2010
Resolution: Cropped and renewed deteriorated area of top flange on outboard girder.
Construction/Loadline › Hull › Side Shell
Issued 10 February 2010 Resolved
Crop and renew delaminated hull plate in mid body compartment forward of fuel tank.
Action required: 705 - Other - as specified
Resolved 8 March 2010
Resolution: Cropped and renewed delaminated hull plate forward of fuel tank.
Stability › Watertight Integrity › Coaming
Issued 10 February 2010 Resolved
Replace broken hatch and coaming leading into engine room.
Action required: 705 - Other - as specified
Resolved 8 March 2010
Resolution: Replaced broken hatch an coaming leading into engine room.
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 10 February 2010 Resolved
Prove integrity of rusted and deteriorated fuel piping or replace.
Action required: 705 - Other - as specified
Resolved 8 March 2010
Resolution: Replaced rusted fuel piping.
Construction/Loadline › Hull › Longitudinal Frame
Issued 10 February 2010 Resolved
Crop and renew 1st and second side longitudinal frames just forward of aft engine room bulkhead.
Action required: 705 - Other - as specified
Resolved 8 March 2010
Resolution: Cropped and renewed 1st and 2nd side longs fwd of aft engine room bulkhead.
Stability › Watertight Integrity › General
Issued 10 February 2010 Resolved
Make hydraulic steering lines penetrating aft bulkhead in engine room watertight.
Action required: 705 - Other - as specified
Resolved 8 March 2010
Resolution: Made penetrations watertight.
Construction/Loadline › Hull › Bottom Plating
Issued 10 February 2010 Resolved
Crop and renew delaminating hull plating just aft of port engine reduction gear, a minimum of 18x18.
Action required: 705 - Other - as specified
Resolved 8 March 2010
Resolution: Cropped and renewed hull plating just aft of port engine reduction gear.
Engineering › Shafting/Propeller Arrangements › Bearing
Issued 10 February 2010 Resolved
Replace starboard cutlass bearing.
Action required: 705 - Other - as specified
Resolved 8 March 2010
Resolution: Replaced cutlass bearing.
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 10 February 2010 Resolved
Clean bilge of lazarette and make compartment ready for inspection.
Action required: 705 - Other - as specified
Resolved 8 March 2010
Resolution: Cleaned bilge in lazzarette and was ready for inspection.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 11 February 2009 Resolved
Provide new aspirin and eyewash for the first aid kit as per 46 CFR 160.041
Action required: 705 - Other - as specified
Due 11 March 2009
Resolved 18 February 2009
Resolution: Aspirin and eyewash replaced.
Lifesaving › Hand Flares › Quantity
Issued 11 February 2009 Resolved
Provide proper number of red flares as per 46 CFR 180.68
Action required: 705 - Other - as specified
Due 11 March 2009
Resolved 18 February 2009
Resolution: Vessel purchased 8 red flares.
Navigation › Piloting/Steering › US Coast Pilot
Issued 11 February 2009 Resolved
Provide Coast Pilot [name withheld], and Tidal Current Tables as per 46 CFR 184.420
Action required: 705 - Other - as specified
Due 11 March 2009
Resolved 18 February 2009
Resolution: All navigation pubs updated.
Lifesaving › Lifefloat › Serviceable
Issued 11 February 2009 Resolved
Replace or remove lifefloat covers with international orange and retroreflective tape
Action required: 705 - Other - as specified
Due 11 March 2009
Resolved 18 February 2009
Resolution: Covers removed, vessel rep stated they are in process of purchasing new ones.
Lifesaving › Lifefloat › Serviceable
Issued 11 February 2009 Resolved
Replace or renew starboard lifefloat as per 46 CFR 185.700
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 March 2009
Resolved 18 February 2009
Resolution: New lifefloat was purchased.
Lifesaving › Lifefloat › Painter
Issued 11 February 2009 Resolved
Attach sea painter to lifefloats as per 46 CFR 180.130(a)(1)
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 March 2009
Resolved 18 February 2009
Resolution: Sea painter attached to all life floats.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 11 February 2009 Resolved
Replace expired float light batteries as per 46 CFR 180
Action required: 705 - Other - as specified
Due 11 March 2009
Resolved 18 February 2009
Resolution: All batteries replaced with expiration date of 2010.
Lifesaving › Lifefloat › Markings
Issued 11 February 2009 Resolved
Mark lifefloats with maximum capacity as per 46 CFR 180.175
Action required: 705 - Other - as specified
Due 11 March 2009
Resolved 18 February 2009
Resolution: All life floats marked.
Operations/Management › Equipment Service/Testing › EPIRB
Issued 11 February 2009 Resolved
Provide means of proof for lifesaving maintenance performance as per 46 CFR 185.702(d)
Action required: 705 - Other - as specified
Due 11 March 2009
Resolved 18 February 2009
Resolution: Manual provided.
Communications › Audible Communications › Bell
Issued 11 February 2009 Resolved
Provide proper ship's bell as per 33 CFR 86
Action required: 705 - Other - as specified
Due 11 March 2009
Resolved 18 February 2009
Resolution: New bell provided.
Fire Fighting › Fire Bucket › Availability
Issued 11 February 2009 Resolved
Provide proper fire buckets as per 46 CFR 181.610
Action required: 705 - Other - as specified
Due 11 March 2009
Resolved 18 February 2009
Resolution: New fire buckets purchased.
Engineering › Bilge Water Management System › Hose
Issued 11 February 2009 Resolved
Replace wasted flexible hose in bilge line in aft engine room under generator
Action required: 705 - Other - as specified
Due 11 March 2009
Resolved 18 February 2009
Resolution: Hose replaced.
Engineering › Fuel Oil Service System › Hose
Issued 11 February 2009 Resolved
Replace wasted fuel hose on generator
Action required: 705 - Other - as specified
Due 11 March 2009
Resolved 18 February 2009
Resolution: Hose cleaned and determined not needed to be replaced.
Engineering › Freshwater System (cylinder head cooling) › Hose
Issued 11 February 2009 Resolved
Double clamp cooling hose on generator
Action required: 705 - Other - as specified
Due 11 March 2009
Resolved 18 February 2009
Resolution: Cooling hose double clamped.
Electrical › Electric Supply System (service) › Battery Installation
Issued 11 February 2009 Resolved
Remove water and provide covers for both battery boxes
Action required: 705 - Other - as specified
Due 11 March 2009
Resolved 18 February 2009
Resolution: Covers added.
Electrical › Electrical Distribution System (service) › Wiring
Issued 11 February 2009 Resolved
Remove dead-end/flying wires throughout engine room
Action required: 705 - Other - as specified
Due 11 March 2009
Resolved 18 February 2009
Resolution: Dead-end wires removed.
Electrical › Electrical Distribution System (service) › Wiring
Issued 11 February 2009 Resolved
Permanently secure wire bundle behind gauge panel in forward engine room.
Action required: 705 - Other - as specified
Due 11 March 2009
Resolved 18 February 2009
Resolution: Wires bundled.
Electrical › Electrical Distribution System (service) › Wiring
Issued 11 February 2009 Resolved
Properly splice wires to float switch in lazarette
Action required: 705 - Other - as specified
Due 11 March 2009
Resolved 18 February 2009
Resolution: Float switch spliced.
Electrical › Electrical Distribution System (service) › Wiring
Issued 11 February 2009 Resolved
Properly splice wires to speaker on aft deck
Action required: 705 - Other - as specified
Due 11 March 2009
Resolved 18 February 2009
Resolution: Speaker properly spliced.
Navigation › Piloting/Steering › Compass Deviation Table
Issued 17 March 2008 Resolved
Provide a current compass deviation table.
Action required: 705 - Other - as specified
Due 17 April 2008
Resolved 18 March 2008
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 17 March 2008 Resolved
Provide current tables.
Action required: 705 - Other - as specified
Due 17 April 2008
Resolved 18 March 2008
Communications › Radio Communications › EPIRB
Issued 17 March 2008 Resolved
Provide a hydrostatic release for the EPRIB.
Action required: 17 - Rectify deficiencies prior to departure
Due 21 March 2008
Resolved 18 March 2008
Lifesaving › Lifefloat › Markings
Issued 17 March 2008 Resolved
Stencil all life floats with the vessel name.
Action required: 705 - Other - as specified
Due 17 April 2008
Resolved 18 March 2008
Accommodation/Occupational Safety › Occupational Safety › Smoking
Issued 17 March 2008 Resolved
Demonstrate proper operation of the smoke detector in the galley.
Action required: 705 - Other - as specified
Due 17 April 2008
Resolved 18 March 2008
Lifesaving › Lifejacket/PFD (Type I) › Lights
Issued 17 March 2008 Resolved
Demonstrate proper operation of all life jacket lights.
Action required: 17 - Rectify deficiencies prior to departure
Due 21 March 2008
Resolved 18 March 2008
Construction/Loadline › Structures › Scuttle
Issued 17 March 2008 Resolved
Drill stop and weld fractures in engine room hatch comming and conduct a water test after completeion
Action required: 705 - Other - as specified
Due 17 April 2008
Resolved 18 March 2008
Engineering › Steering Gear System › Linkage
Issued 13 February 2008 Resolved
Replace deteriorated hardware on the rudder jockey bar.
Action required: 705 - Other - as specified
Resolved 28 February 2008
Resolution: The hardware on the rudder jockey bar was renewed.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 13 February 2008 Resolved
Repair broken welds on hand rails.
Action required: 705 - Other - as specified
Resolved 28 February 2008
Resolution: All rails on the aft cargo deck were totally renewed.
Engineering › Sea-water System (primary cooling) › Piping
Issued 13 February 2008 Resolved
Crop and renew the cooling water overboard coupling in hull on port side.
Action required: 705 - Other - as specified
Resolved 28 February 2008
Resolution: The hull penetration for the cooling water overboard was renewed and properly welded.
Engineering › Steering Gear System › Rudder
Issued 17 January 2008 Resolved
Repack both gudgeons on both rudders.
Action required: 705 - Other - as specified
Resolved 28 February 2008
Resolution: Both rudders gudgeons were totally renewed and properly repacked. All weld repairs were satisfactory.
Engineering › Bilge Water Management System › Piping
Issued 17 January 2008 Resolved
Replace bilge water overboard piping and valve on hull on starboard side in engine room.
Action required: 705 - Other - as specified
Resolved 28 February 2008
Resolution: The bilge overboard piping between the bilge pump discharge and the hull penetration was also renewed.
Lifesaving › Lifefloat › Paddle
Issued 8 January 2007 Resolved
Properly secure and lable the paddle for the port lifefloat in accordance with 46 CFR 180.130 and 185.604.
Action required: 705 - Other - as specified
Due 8 February 2007
Resolved 7 February 2007
Resolution: Properly secured and labeled the paddle for the port lifefloat in accordance with 46 CFR 180.130 and 185.604.
Navigation › Piloting/Steering › US Coast Pilot
Issued 8 January 2007 Resolved
Provide current Coast Pilot and Light List in accordance with 46 CFR 184.420.
Action required: 705 - Other - as specified
Due 8 February 2007
Resolved 7 February 2007
Resolution: Provided current Coast Pilot and Light List in accordance with 46 CFR 184.420.
Lifesaving › Lifefloat › Serviceable
Issued 8 January 2007 Resolved
Make repairs to the lifefloat where needed in accordance with 46 CFR 180.137.
Action required: 705 - Other - as specified
Due 8 February 2007
Resolved 7 February 2007
Resolution: Made repairs to the lifefloat where needed in accordance with 46 CFR 180.137.
Operations/Management › Equipment Service/Testing › EPIRB
Issued 8 January 2007 Resolved
Replace the hydrostatic release.
Action required: 705 - Other - as specified
Due 8 February 2007
Resolved 7 February 2007
Resolution: Replaced the hydrostatic release.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 8 January 2007 Resolved
Provide guards over rotating machinery on the pump off of the starboard main engine in accordance with 46 CFR 177.960.
Action required: 705 - Other - as specified
Due 8 February 2007
Resolved 7 February 2007
Resolution: Provided guards over rotating machinery on the pump off of the starboard main engine in accordance with 46 CFR 177.960.
Engineering › Sea-water System (primary cooling) › Piping
Issued 8 January 2007 Resolved
Prove proper operation of the raw water pipe to the starboard main engine.
Action required: 705 - Other - as specified
Due 8 February 2007
Resolved 7 February 2007
Resolution: Proved proper operation of the raw water pipe to the starboard main engine.
Engineering › Generator (propulsion/auxiliary-electric) › Overcurrent Devices Circuitry
Issued 8 January 2007 Resolved
Prove the operating ambient temperature of the generator in accordance with 46 CFR 183.320.
Action required: 705 - Other - as specified
Due 8 February 2007
Resolved 7 February 2007
Resolution: Proved the operating ambient temperature of the generator in accordance with 46 CFR 183.320.
Electrical › Electrical Distribution System (service) › Wiring
Issued 8 January 2007 Resolved
Remove the dead-end wires in the engine room in accordance with 46 CFR 183.340.
Action required: 705 - Other - as specified
Due 8 February 2007
Resolved 7 February 2007
Resolution: Removed the dead-end wires in the engine room in accordance with 46 CFR 183.340.
Construction/Loadline › Hull › Bottom Plating
Issued 26 January 2006 Resolved
Crop and renew all deteriorated hull plating in the engine. 46CFR176.610
Action required: 705 - Other - as specified
Due 26 February 2006
Resolved 8 February 2006
Resolution: Hull plating renewed
Lifesaving › Visual Distress Signals (General) › Marking
Issued 3 November 2005 Resolved
Properly mark portable watertight container for distress signals in accordance with 46 CFR 185.614
Action required: 705 - Other - as specified
Due 16 December 2005
Resolved 6 December 2005
Resolution: Portable watertight container for distress signals properly marked
Engineering › Fuel Oil Service System › Tank
Issued 3 November 2005 Resolved
Provide and install a pipe cap on the fuel trap drain in accordance with 46 CFR 182.455 (b) (9).
Action required: 705 - Other - as specified
Due 16 December 2005
Resolved 6 December 2005
Resolution: Pipe cap installed
Engineering › Bilge Water Management System › Manifold
Issued 3 November 2005 Resolved
Provide and install valve handles on the bilge suction manifold in the engine room.46 CFR 182.510
Action required: 705 - Other - as specified
Due 16 December 2005
Resolved 6 December 2005
Resolution: Handles installed
Engineering › Generator (propulsion/auxiliary-electric) › Outlet Box
Issued 3 November 2005 Resolved
Properly secure the ship service generator.46CFR182.100
Action required: 705 - Other - as specified
Due 16 December 2005
Resolved 20 December 2005
Resolution: Generator properly bolted down through mounts.
Engineering › Generator (propulsion/auxiliary-electric) › Outlet Box
Issued 3 November 2005 Resolved
Properly secure the ship service generator housing. 46CFR182.100
Action required: 705 - Other - as specified
Due 16 December 2005
Resolved 6 December 2005
Resolution: Generator housing rebolted closed.
Engineering › Fuel Oil Service System › Valve
Issued 3 November 2005 Resolved
Properly label the emergency fuel shutoff in accordance with 46 CFR 185. 608.
Action required: 705 - Other - as specified
Due 16 December 2005
Resolved 6 December 2005
Resolution: Fuel shutoffs labeled
Engineering › Bilge Water Management System › Not Operational
Issued 3 November 2005 Resolved
Prove proper operation of the bilge high level alarm in the lazzarette. 46CFR182.530
Action required: 705 - Other - as specified
Due 16 December 2005
Resolved 6 December 2005
Resolution: Bilge alarm operational
Electrical › Electrical Distribution System (service) › Metallic Enclosure/Frame
Issued 3 November 2005 Resolved
Replace the motor controller box for the electrical motor for the steering system. 46CFR183.330
Action required: 705 - Other - as specified
Due 16 December 2005
Resolved 20 December 2005
Resolution: New control box installed.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 3 November 2005 Resolved
Prove proper operation of the water light on the life ring. 46CFR 180.70
Action required: 705 - Other - as specified
Due 16 December 2005
Resolved 6 December 2005
Resolution: Light operational.
Documentation › Certificates/Documents › FCC SSL
Issued 3 November 2005 Resolved
Provide a current FCC radio safety certificate. 47 CFR 80
Action required: 705 - Other - as specified
Due 16 December 2006
Resolved 26 January 2006
Resolution: FCC safety certificate obtained
Electrical › Electrical Distribution System (service) › Non-conducting Deck Covering
Issued 29 November 2004 Resolved
Provide non-conductive matting behind the switchboard as required by 46 CFR 183.330.
Action required: 705 - Other - as specified
Due 29 December 2004
Resolved 10 December 2004
Resolution: Non-conductive matting installed.
Communications › Radio Communications › EPIRB
Issued 29 November 2004 Resolved
Replace expired batteries on EPIRB IAW 46 CFR 185.728.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 December 2004
Resolution: New battery installed.
Communications › Radio Communications › EPIRB
Issued 29 November 2004 Resolved
Renew hydrostatic release for EPIRB IAW 46 CFR 185.728.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 December 2004
Resolution: New hydrostatic release installed.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 29 November 2004 Resolved
Provide 60-ft of lifeline for lifebuoy as required by 46 CFR 180.70.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 December 2004
Resolution: 60-ft of line attached.
Lifesaving › Lifefloat › Float Free
Issued 29 November 2004 Resolved
Install life floats in a float free arrangement as required by 46 CFR 180.20-5.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 December 2004
Resolution: Life floats installed in float free arrangement.
Construction/Loadline › Structures › Door
Issued 29 November 2004 Resolved
Replace as new window on rear hatch IAW 46 CFR 177.1010.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 29 December 2004
Resolved 10 December 2004
Resolution: New window installed.
Accommodation/Occupational Safety › Cooking Systems › Cooking Fuel
Issued 29 November 2004 Resolved
Install sea rails on galley stove as required by 46 CFR 184.220.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 29 December 2004
Resolved 10 December 2004
Resolution: Sea rails installed.
Accommodation/Occupational Safety › Refrigeration (stores) › General
Issued 29 November 2004 Resolved
Secure refrigerator to vessel as required by 46 CFR 176.818.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 29 December 2004
Resolved 10 December 2004
Resolution: Refrigerator secured.
Deck/Cargo › Mooring/Anchoring › Anchor Rope
Issued 29 November 2004 Resolved
Increase length of anchor line IAW 46 CFR 184.300.
Action required: 705 - Other - as specified
Due 29 December 2004
Resolved 10 December 2004
Resolution: 600-Ft of 1 inch line now onboard.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 29 November 2004 Resolved
Mount B-II portable fire extinguishers in correct brackets IAW 46 CFR 176.810.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 29 December 2004
Resolved 10 December 2004
Resolution: Extinguishers mounted with manufacturers specified brackets.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 29 November 2004 Resolved
Provide proof of enrollment in a drug program as required by 46 CFR Part 16.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 December 2004
Resolution: Vessel captain and crew now enrolled in drug screening program.
Stability › Incline Test
Issued 22 August 2003 Resolved
Provide proof that the stability was "sistered" from another vessel, locate the stability letter, or conduct a simplified stability test as required by 46 CFR 176.306. LEGACY COMPONENT DESC: Stability Letter
Due 22 September 2003
Resolved 22 September 2003
Resolution: When the vessel was built in 1967 OCMIs had the authority to determine whether a vessel needed to have a satbility test or not. This vessel was not an unusual design and never had the test. It has been operating ever since without a stability letter.
Personnel › Training
Issued 22 August 2003 Resolved
Provide proof of CPR & first aid training for at least 50% of the crew in accordance with NVIC 1-91 LEGACY COMPONENT DESC: First Aid/CPR
Due 22 September 2003
Resolved 22 September 2003
Resolution: Proof of CPR and 1st aid traiing was available for 50% of the crew.
Documentation › Logs/Records
Issued 22 August 2003 Resolved
Provide proof of annual drug screens in accordance with 46 CFR 16.260 LEGACY COMPONENT DESC: Drug Test Records
Due 22 September 2003
Resolved 22 September 2003
Resolution: Proof of annual drug screens for the crew was provided by the master.
Documentation › Logs/Records
Issued 22 August 2003 Resolved
Provide a current training log book as required by 46 CFR 185.420.
Due 22 September 2003
Resolved 22 September 2003
Resolution: A crew training log book was available for inspection.
Documentation › Logs/Records
Issued 22 August 2003 Resolved
Provide a bridge log showing when fire fighting and lifesaving drills were conducted as required by 46 CFR 185.520 & 524. LEGACY COMPONENT DESC: Logbook (official)
Due 22 September 2003
Resolved 22 September 2003
Resolution: A bridge log showing fire fighting and lifesaving drills was provided.
Operations/Management › Navigation Safety
Issued 22 August 2003 Resolved
Provide Tide Tables & Tidal Current Tables as required by 46 CFR 184.420. LEGACY COMPONENT DESC: Carriage of Charts and Publications
Due 22 September 2003
Resolved 22 September 2003
Resolution: Current Tide Tables & Tidal Current Tables were available on the vessel.
Construction/Loadline › Hull
Issued 22 August 2003 Resolved
Relocate and repair broken stanchion in the lazarette. The stanchion's new location must not interfere with the movement of the steering system to the satisfaction of the attending marine inspector as required by 46 CFR 176.814. LEGACY COMPONENT DESC: Stiffener
Condition: Design Flaw
Due 22 September 2003
Resolved 22 September 2003
Resolution: The broken sytanchion in thelazarette was rewelded and the rudder stops were improved to prevent the sterring system from making contact with the stanchion.
Stability › Unintentional Flooding
Issued 22 August 2003 Resolved
Repair all water tight penetrations & seal all openings in the bulkhead between the forward end of the engine room and the passenger space. Make all piping & wiring penetrations watertight to the satisfaction of the attending marine inspector as required by 46 CFR 176.802.
Condition: Improper/Lack of Maintenance
Due 22 September 2003
Resolved 22 September 2003
Resolution: All of the penetrations and open holes were sealed in the forward bulkhead of the engineroom.
Fire Fighting › Means of Escape
Issued 22 August 2003 Resolved
Mark the escape hatch from the crew accommodations to the pilot house with the words "Emergency Exit Keep Clear" as required by 46 CFR185.606. LEGACY COMPONENT DESC: Escape Route Signs
Condition: Unknown
Due 22 September 2003
Resolved 22 September 2003
Resolution: The top of the escape hatch coming from the accomodations to the wheel house was marked appropriately.
Documentation › Manifests/Lists
Issued 22 August 2003 Resolved
Provide a passenger safety orientation card as required by 46 CFR 185.506. LEGACY COMPONENT DESC: Muster List/Emergency Instructions
Due 22 September 2003
Resolved 22 September 2003
Resolution: A passenger safety orientation card was developed and provided for inspection.
Fire Fighting › Portable Dry Chemical Fire Extinguisher
Issued 22 August 2003 Resolved
Change out one of the B-I fire extinguishers to a B-II to meet the required amount of portable fire extinguishers as stated on the vessel's Certificate of Inspection as required by 46 CFR 176.180. LEGACY COMPONENT DESC: Number
Condition: Improper Installation
Due 22 September 2003
Resolved 22 September 2003
Resolution: The B-I extinguisher was replaced witha B-II to meet the required number and type on the COI.
Engineering › Fuel Oil Service System
Issued 22 August 2003 Resolved
Replace the existing non-metalic hoses used as fuel oil supply lines from each supply tank to the water trap (first stage strainer) with flexible non-metalic hoses that meet standards SAE J-1942 and SAE J-1475 as required by 46 CFR 182.20-30(d). LEGACY COMPONENT DESC: Hose
Condition: Improper Installation
Due 22 September 2003
Resolved 22 September 2003
Resolution: The exisisting non-metalic hoses were replaced by non-metalic hoses that meet the requirements of SAE J-1942.
Engineering › Fuel Oil Service System
Issued 22 August 2003 Resolved
Replace generator fuel supply flexible non-metalic hose so that the length of an flexible portion of the system does not exceed 30 inches. Hard pipe must be installed to ensure the 30 inch requirement is not exceeded. Aluminum may be used but the aluminum must be at least schedule 80. LEGACY COMPONENT DESC: Piping
Condition: Improper Installation
Due 22 September 2003
Resolved 22 September 2003
Resolution: The fuel oil supply flexible non-metalic hose that exceeded the 30 inch length requirement was replaced with copper piping with flexible non-metalic hoses at either end that do not exceed 30 inches.
Electrical › Electrical Distribution System (service)
Issued 22 August 2003 Resolved
Install metal or metal inserted rubber wire hangers to support electrical wires or cables as required by 46 CFR 183.340 (b)(4). LEGACY COMPONENT DESC: Wiring
Condition: Improper Installation
Due 22 September 2003
Resolved 22 September 2003
Resolution: The plastic wire ties that were holding cables & wires to the overhead in the void spaces have been replaced with metal inserted rubber supports.l
Electrical › Lighting (service)
Issued 22 August 2003 Resolved
Replace steel guard on light in lazarette as required by 46 CFR 183.410. LEGACY COMPONENT DESC: Lighting Fixture
Condition: Improper Installation
Due 22 September 2003
Resolved 22 September 2003
Resolution: A steel cage that protects the glass globe on the light was installed.
Lifesaving › Rigid Liferafts
Issued 14 August 2003 Resolved
Renew the sea painter float free link on all three life floats as required by 46 CFR 180.130. LEGACY COMPONENT DESC: Weak Link
Condition: Improper Installation
Due 22 September 2003
Resolved 8 September 2003
Resolution: Had to order the proper strength links, when they arrived he installed the links.
Lifesaving › Rigid Liferafts
Issued 14 August 2003 Resolved
Repair and prove operation two of the three water lights on the life floats and make them all operable as required by 46 CFR 180.175(d). LEGACY COMPONENT DESC: Lamp (outside)
Condition: Improper/Lack of Maintenance
Due 22 September 2003
Resolved 8 September 2003
Resolution: Installed new batteries in the malfunctioning lights and corrected the situation.
Unknown
Issued 19 October 2001 Resolved
Unknown Component - Unknown Cause/Condition
Condition: Unknown
Due 19 November 2001
Resolved 28 November 2001
Unknown
Issued 19 October 2001 Resolved
Unknown Component - Unknown Cause/Condition
Condition: Unknown
Due 19 November 2001
Resolved 28 November 2001
Unknown
Issued 19 October 2001 Resolved
Unknown Component - Unknown Cause/Condition
Condition: Unknown
Due 19 November 2001
Resolved 28 November 2001
Unknown
Issued 19 October 2001 Resolved
Unknown Component - Unknown Cause/Condition
Condition: Unknown
Due 19 November 2001
Resolved 28 November 2001
Unknown
Issued 19 October 2001 Resolved
Unknown Component - Unknown Cause/Condition
Condition: Unknown
Due 19 November 2001
Resolved 28 November 2001
Unknown
Issued 19 October 2001 Resolved
Unknown Component - Unknown Cause/Condition
Condition: Unknown
Due 19 November 2001
Resolved 28 November 2001
Unknown
Issued 19 October 2001 Resolved
Unknown Component - Unknown Cause/Condition
Condition: Unknown
Due 19 November 2001
Resolved 28 November 2001
Unknown
Issued 19 October 2001 Resolved
Unknown Component - Unknown Cause/Condition
Condition: Unknown
Due 19 November 2001
Resolved 28 November 2001
Unknown
Issued 19 October 2001 Resolved
Unknown Component - Unknown Cause/Condition
Condition: Unknown
Due 19 November 2001
Resolved 28 November 2001
Unknown
Issued 19 October 2001 Resolved
Unknown Component - Unknown Cause/Condition
Condition: Unknown
Due 15 November 2001
Resolved 28 November 2001
Lifesaving
Issued 25 October 2000 Resolved
Prior to the carriage of passengers, conduct satisfactory fire and man overboard drills.
Condition: Unknown
Due 25 October 2000
Resolved 25 October 2000
Construction/Loadline
Issued 25 October 2000 Resolved
Clean bilge suction strainer for steering compartment.
Condition: Unknown
Due 25 October 2000
Resolved 25 October 2000
Unknown
Issued 4 October 1999 Resolved
REPLACE BATTERY IN CENTER LIFEFLOAT.
Condition: Unknown
Due 4 November 1999
Resolved 21 October 1999
Unknown
Issued 4 October 1999 Resolved
REPLACE WASTED BLACK NAV BALLS
Condition: Unknown
Due 4 November 1999
Resolved 21 October 1999
Unknown
Issued 4 October 1999 Resolved
PROVE PROPER OPERATION OF BOTH MDE'S.
Condition: Unknown
Due 4 November 1999
Resolved 21 October 1999
Unknown
Issued 4 October 1999 Resolved
INSTALL 406 EPIRB PRIOR TO GETTING U/W
Condition: Unknown
Due 20 October 1999
Resolved 21 October 1999
Unknown
Issued 4 October 1999 Resolved
INSTALL BILGE ALARMS IN ENGINEROOM AND STEERING COMPARTMENT PRIOR TO GETTING UNDERWAY.
Condition: Unknown
Due 20 October 1999
Resolved 21 October 1999
Documentation
Issued 30 September 1998 Resolved
Properly log testing requirements of EPIRB iaw 46 CFR 185.728.
Condition: Unknown
Due 30 September 1998
Resolved 30 September 1998
Lifesaving
Issued 30 September 1998 Resolved
Replace Port 12 man Buoyant Apparatus.
Condition: Unknown
Due 30 September 1998
Resolved 30 September 1998
Construction/Loadline
Issued 30 September 1998 Resolved
Make Repairs to holded Stut support in steering compt. Welded cap contains pin hole.
Condition: Unknown
Due 30 September 1998
Resolved 30 September 1998
Lifesaving
Issued 30 September 1998 Resolved
Replace existing first Aid kit with approved kit iaw 46 CFR 184.710
Condition: Unknown
Due 30 September 1998
Resolved 30 September 1998
Lifesaving
Issued 30 September 1998 Resolved
Complete and properly log required drills iaw 46 CFR 185.420
Condition: Unknown
Due 30 September 1998
Resolved 30 September 1998
Electrical
Issued 27 January 1997 Resolved
PROVIDE PROPER OPERATION OF THE GENERATOR OVERSPEED DEVICE.
Condition: Unknown
Due 27 January 1997
Resolved 27 January 1997
Navigation
Issued 27 January 1997 Resolved
POST EMERGENCY BROADCAST PLACARD ON SINGLE SIDEBAND RADIO.
Condition: Unknown
Due 27 January 1997
Resolved 27 January 1997
Navigation
Issued 27 January 1997 Resolved
PROCURE LIGHT LIST AND LEAVE ON BRIDGE.
Condition: Unknown
Due 27 January 1997
Resolved 27 January 1997
Construction/Loadline
Issued 10 September 1990 Resolved
WELD PINHOLE IN PORT STRUT SUPPORT TO STOP LEAKAGE IN LAZZARETTE.
Condition: Unknown
Due 10 September 1990
Resolved 10 September 1990
Electrical
Issued 10 September 1990 Resolved
RENEW WIRE ON STERN LIGHT AND MAKE IT SECURE ON BRACKET.
Condition: Unknown
Due 10 September 1990
Resolved 10 September 1990
Electrical
Issued 10 September 1990 Resolved
INSTALL COVER ON ELECTRIC PANEL BOX IN MACHINERY ROOM.
Condition: Unknown
Due 10 September 1990
Resolved 10 September 1990

Casualty record · 3

12 July 2007Routine · role: Transiting Vicinity of Primary Subject · serious marine incident, as classified · activity 3000967
31 May 2011Routine · role: Involved in a Marine Casualty · activity 4038726
21 December 2016Routine · role: Involved in a Marine Casualty · activity 6063634
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

MADISON GAIL (2007–2011). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.