MAURY USCG vessel records
← All vessels

PINEAPPLE EXPRESS

PINEAPPLE EXPRESS is a 1997 passenger vessel (inspected). The Coast Guard has recorded 22 inspections since 2016, most recently in March 2026, along with 51 deficiencies — 1 with no resolution recorded —.

Records from 2016 to 2026. Most recent: inspection, 18 March 2026.

Built
1997
Last inspected
18 March 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Everything above is free. The detail below — the inspection history, the deficiency record and the documentation record — is Professional, $39 a month. Sign in.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 18 March 2026
…with no type recorded5
…past their stated due date1
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDD8490
454774
Flag
UNITED STATES
Maury page id
psix-454774

Documentation record

Tonnage as PSIX records it6 - Regulatory (Subpart C or D), Gross Ton
4 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
Detail on this page

22 inspections, each with its date, unit and type; 51 deficiencies with the resolution recorded against each; the documentation record, as PSIX holds it. The counts in the summary above are the same counts, and they are free.

$39 a month or $299 a year, every vessel page, cancel any time. Founding rate $19.99 a month for life, for the first 200 subscribers. Plans Sign in

Maury does not score, rate or grade vessels, at any price.

Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 22

18 March 2026 Annual Inspection · Drydock Exam
Physical examination · OP location-Sector Honolulu Prevention Department- Wailuku · USCG Oceania District (CGD-O) · Activity 8327808
4 March 2025 COI Inspection · Deficiency Check
Physical examination · OP location-Sector Honolulu Prevention Department- Wailuku · USCG Oceania District (CGD-O) · Activity 8087735
6 March 2024 Annual Inspection · Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7874725
10 January 2024 Deadweight Survey
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7855902
7 March 2023 Deficiency Check · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7646655
22 February 2023 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7640569
1 March 2022 Deficiency Check · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7403559
30 March 2021 DAPI Audit · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7170800
17 March 2021 Deficiency Check · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7155718
17 March 2021 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7175335
26 February 2021 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7154390
11 March 2020 Deficiency Check · Internal Structural Exam · Drydock Exam · COI Inspection · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6925642
15 May 2019 Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6685165
14 May 2019 DAPI Audit · Annual Inspection · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6684463
13 November 2018 Administrative Inspection · Damage Survey
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6581763
20 March 2018 Drydock Exam · Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6375683
31 October 2017 Type not recorded
No type recorded · Station Maui · USCG Oceania District (CGD-O) · Activity 6298693
3 September 2017 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6275727
29 July 2017 Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6233520
29 March 2017 Deficiency Check · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6132506
25 December 2016 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6062839
26 May 2016 Annual Inspection · DAPI Audit · Hull Examination · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5934307

Deficiency record · 51

99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 18 March 2026 Resolved
The marine employer must have a sufficient number of alcohol testing devices readily accessible on board the vessel. Alcohol test strips aboard were expired; vessel replaced with new stock from office. 46 CFR 4.06-15 (a)
Action required: 10 - Deficiency Rectified
Resolved 19 March 2026
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 18 March 2026 Resolved
Each portable fire extinguisher on a vessel must be of an approved type. The minimum number of portable fire extinguishers required on a vessel must be acceptable to the cognizant Officer in Charge, Marine Inspection, but must not be fewer than the minimum number required by table 1 to § 181.500(b) and other provisions of this section. Vessel was missing 01 fire extinguisher required by COI; a new 3A 40BC fire extinguisher was purchased and installed. 46 CFR 181.500 (a)
Action required: 10 - Deficiency Rectified
Resolved 19 March 2026
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 18 March 2026 Resolved
A vessel not required to have a power driven fire pump by § 181.300 must have at least three 9.5 liter (21/2 gallon) buckets, with an attached lanyard satisfactory to the cognizant OCMI, placed so as to be easily available during an emergency. The words “FIRE BUCKET” must be stenciled in a contrasting color on each bucket. Vessel was missing 1 of 3 required fire buckets; missing bucket was installed aboard during inspection. 46 CFR 181.610
Action required: 10 - Deficiency Rectified
Resolved 19 March 2026
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 18 March 2026 Resolved
A space containing machinery powered by, or fuel tanks for, gasoline must have a ventilation system that complies with this section and consists of: (ii) A mechanical exhaust system consisting of at least two ventilation exhaust ducts located at the end of the space opposite from where the supply ducts are fitted, which extend to the lowest part of the bilge of the space on each side of the space, and which are led to one or more powered exhaust blowers. Vessel's rear ventilation exhaust duct in the fuel tank space is disconnected and incomplete. Make permanent repairs to restore original functionality to the rear ducting within 30 days. 46 CFR 182.460 (a) (ii)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 April 2026
Resolved 19 March 2026
Resolution: Ducting renewed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 18 March 2026 Resolved
Exhaust blower switches must be located outside of any space required to be ventilated by this section, and must be of the type interlocked with the starting switch and the ignition switch so that the blowers are started before the engine starter motor circuit or the engine ignition is energized. A red warning sign at the switch must state that the blowers must be operated prior to starting the engines for the time sufficient to insure at least one complete change of air in the space served. Vessel does not have a blower warning sign. Install signage as required for the minimum time sufficient for 1 complete air change of below deck space within 30 days. 46 CFR 182.460 (e)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 April 2026
Resolved 25 March 2026
Resolution: Received photo of blower warning sign installed at helm.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 18 March 2026 Resolved
An adult life jacket must be provided for each person carried on board a vessel. Four adult life jackets were found in unserviceable condition. Vessel provided four new adult life jackets from office. 46 CFR 180.71
Action required: 10 - Deficiency Rectified
Resolved 19 March 2026
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 18 March 2026 Resolved
Each survival craft must be:(2)Stowed so that when the vessel sinks the survival craft floats free and, if inflatable, inflates automatically. Vessel's life float was inadvertently secured to vessel and not float free. Vessel reinstalled life float to make float free. 46 CFR 180.130 (a) (2)
Action required: 10 - Deficiency Rectified
Resolved 19 March 2026
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 18 March 2026 No resolution recorded
Repairs or alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without the approval of the cognizant [name withheld] or alterations that affect the safety of the vessel include, but are not limited to: replacement, repair, or refastening of deck or hull planking, plating, and structural members; repair of plate or frame cracks; damage repair or replacement, other than replacement in kind, of electrical wiring, fuel lines, tanks, boilers and other pressure vessels, and steering, propulsion and power supply systems; alterations affecting stability; and repair or alteration of lifesaving, fire detecting, or fire extinguishing equipment. Vessel plans to replace collar structures with a new manufacture (Inventech currently aboard, Wing being installed) on 12 April 2026. This change has implications on structural and stability approvals issued by the Marine Safety Center (MSC) Provide MSC with necessary information for review and provide MSC's final evaluation to [name withheld].46 CFR 176.700(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 May 2026 — due date passed with no resolution recorded
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 4 March 2025 Resolved
A vessel must be provided with bilge pumps in accordance with Table 182.520(a). A submersible electric bilge pump may be used provided that: The pump is listed by an independent laboratory as meeting the requirements in UL 1113. Aft bilge pump inoperable and not meeting the requirements of UL 1113. Pump requires renewal. 46CFR182.520
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 March 2025
Resolution: Bilge pump replaced with Rule 2000 (UL1113). Operating as intended.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 4 March 2025 Resolved
A flammable vapor detection system must provide a visual and audible alarm at the operating station. Flammable vapor detection system inoperable. Provide proof of operating flammable vapor detection system. 46CFR182.480(d)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 March 2025
Resolution: Display unit at helm for flammable vapor detection system replaced. Operating as intended with visual and audible alarm.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 4 March 2025 Resolved
Each vessel that operates on high seas must have on board a FCC Type Accepted Category 1, 406 MHz EPIRB, installed to automatically float free and activate. Provide proof for expiration date for hydrostatic release unit. 46CFR180.64
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 April 2025
Resolved 18 March 2025
Resolution: New Epirb HRU installed on vessel
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 4 March 2025 Resolved
Each item of lifesaving equipment determined by the marine inspector to not be in serviceable condition must be repaired or replaced. Provide (02) marked paddles for life float. Provide proof for expiration date for hydrostatic release unit. Vessel shall not operate more than 3 miles from shore until life float equipment and and free floating stowage requirements are met. 46CFR176.808(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 April 2025
Resolved 18 March 2025
Resolution: New Life float paddles and HRU installed on vessel
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 4 March 2025 Resolved
A vessel must carry either a first-aid kit that meets the requirements in 46 CFR 199.175(b)(10) or a kit with equivalent contents and instructions. First aid kit onboard requires renewal for expired content. 46CFR184.710
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 April 2025
Resolved 18 March 2025
Resolution: New first aid kit installed on vessel
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 7 March 2023 Resolved
A flammable vapor detection system must provide a visual and audible alarm at the operating station. The flammable vapor detection system is not working. Provide proof of operating flammable vapor detection system. 46CFR182.480(d)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 March 2023
Resolution: New detector installed.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 7 March 2023 Resolved
Exhaust blower switches must be of the type interlocked with the starting switch and the ignition switch so that the blowers are started before the engine starter motor circuit or the engine ignition is energized. The exhaust blower is not interlocked with the starting switch. Interlock exhaust blower with the starting switch. 46CFR182.460(e)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 March 2023
Resolution: Ignition interlock wired into blower. All sat.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 7 March 2023 Resolved
The minimum number of portable fire extinguishers required on a vessel must not be fewer than the minimum number required by Table 181.500(b). Vessel needs an additional 2-A rated portable fire extinguisher for the Accommodation space. 46CFR181.500(a)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 March 2023
Resolution: New extinguisher provided.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 7 March 2023 Resolved
A vessel must be fitted with ground tackle and mooring lines necessary for the vessel to be safely anchored or moored. The anchor is broken and unusable. Repair or replace the anchor. 46CFR184.300
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 7 March 2023
Resolution: Anchor flukes properly installed.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 7 March 2023 Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection giving consideration to necessary facilities for passengers and crew. The port quarter ladder bracket is wasted. Repair or replace bracket. 46CFR177.100
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 April 2023
Resolved 26 March 2023
Resolution: Bracket repaired.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 1 March 2022 Resolved
Exhaust blower switches must be located outside of any space required to be ventilated by this section, and must be of the type interlocked with the starting switch and the ignition switch so that the blowers are started before the engine starter motor circuit or the engine ignition is energized. Ventilation not interlocked with engine starter motor. Install and demonstrate interlocked system. 46 CFR 182.460(e)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 31 March 2022
Resolution: Interlock installed.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 1 March 2022 Resolved
The marine employer must have a sufficient number of alcohol testing devices readily accessible on board the vessel. Vessel's alcohol test strips are expired. Provide alcohol test strips. 46 CFR 4.06-15
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 28 March 2022
Resolution: Test strips provided.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 1 March 2022 Resolved
Electrical equipment on a vessel must be installed to protect the vessel from electrical hazards. Clean off corroded terminals and bus bar above fuel tank compartment. 46 CFR 183.200(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 28 March 2022
Resolution: New terminals installed.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 1 March 2022 Resolved
An internal structural examination consists of a complete examination of the vessel's main strength members, including the major internal framing, the hull plating and planking, voids, and ballast, cargo, and fuel oil tanks. Prepare fuel tank and area under fuel tank for inspection. 46 CFR 176.610(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 25 March 2022
Resolution: Fuel tank space made ready for inspection.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 1 March 2022 Resolved
Repairs or alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without the approval of the cognizant OCMI, except during an emergency. Crack at strake stbd side. Submit repair proposal for approval by Marine Inspector. 46 CFR 176.700(a)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 11 March 2022
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 1 March 2022 Resolved
Repairs or alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without the approval of the cognizant OCMI, except during an emergency. Crack at bow on central vertical keel plating. Submit repair proposal for approval by Marine Inspector. 46 CFR 176.700(a)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 11 March 2022
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 1 March 2022 Resolved
Repairs or alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without the approval of the cognizant OCMI, except during an emergency. Crack at bow on tube. Submit repair proposal for approval by Marine Inspector. 46 CFR 176.700(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 11 March 2022
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 1 March 2022 Resolved
Repairs or alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without the approval of the cognizant OCMI, except during an emergency. Crack at strake stbd aft under trailer brackets. Submit repair proposal for approval by Marine Inspector. 46 CFR 176.700(a)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 11 March 2022
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 1 March 2022 Resolved
Repairs or alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without the approval of the cognizant OCMI, except during an emergency. Crack on port aft bimini. Submit repair proposal for approval by Marine Inspector. 46 CFR 176.700(a)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 11 March 2022
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 1 March 2022 Resolved
25 Mar 2022 - Tank space soft patch removed for tank space inspection. 4 cracks located on brackets that support tank. Remove fuel tank for deck inspection. Repair 04 cracked brackets once fuel tank removed from space. Complete within 30 days - Due 25 Apr 2022. 46 CFR 176.610(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 April 2022
Resolved 21 April 2022
Resolution: 05 tank support cracks welded.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 30 March 2021 Resolved
Provide Letter of Regulatory Compliance (LORC) for Reliable Drug Testing Services Consortium.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 April 2021
Resolved 6 April 2021
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 30 March 2021 Resolved
Update EAP Information to reflect current changes to DAPI program (i.e., Provide EAP information posted in vessel common space; Identify SAP and update EAP information with contact information; Hot-line information, etc).
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 April 2021
Resolved 6 April 2021
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 30 March 2021 Resolved
Provide the DAPI covered employees list for BWR vessels. Confirm all employees have record of preemployment test or subject to random since COVID-19 shutdown.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 April 2021
Resolved 6 April 2021
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 30 March 2021 Resolved
An EAP training program must be conducted for the employer's crewmembers and supervisory personnel. The training program must include at least the following elements: the effects and consequences of drug and alcohol use on personal health, safety, and work environment; the manifestations and behavioral cues that may indicate drug and alcohol use and abuse; and documentation of training given to crewmembers and the employer's supervisory personnel (continued on second page). Supervisory personnel must receive at least 60 minutes of training. Provide proof of completed EAP training for all personnel.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 April 2021
Resolved 6 April 2021
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 30 March 2021 Resolved
Confirm Blue Water Rafting's policy regarding employment for mariner's who have tested positive on any of the five types of DOT chemical tests and the MRO return to work process.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 April 2021
Resolved 6 April 2021
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 17 March 2021 Resolved
Life Float light not operating as designed. Provide operational life float light.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 March 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 17 March 2021 Resolved
Aft bilge pump not operational. Provide working aft bilge pump.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 March 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 17 March 2021 Resolved
Visual auto bilge indicator not operational for aft bilge pump. Provide visual auto bilge indicator at helm for aft bilge pump.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 March 2021
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 17 March 2021 Resolved
Master and deckhand did not have Marine Radio Operator Permit (MROP). Provide master and/or crew who has valid MROP.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 April 2021
Resolved 27 April 2021
Resolution: MROP Provided.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 17 March 2021 Resolved
Hydraulic hose for port side steering ram showing inner metallic braiding corrosion that is causing hose deformation. Provide new port side hydraulic hose.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 April 2021
Resolved 7 April 2021
Resolution: New hose installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 17 March 2021 Resolved
Hydraulic hose for port side engine fuel showing inner metallic braiding corrosion that is causing hose deformation. Provide new port side engine fuel hose.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 April 2021
Resolved 7 April 2021
Resolution: New hose installed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 17 March 2021 Resolved
Battery selector in battery compartment not secured/mounted. Make battery selector secure/mounted.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 April 2021
Resolved 7 April 2021
Resolution: Battery selectyor mounted.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 17 March 2021 Resolved
Bus bar under helm not secured/mounted. Secure/mount bus bar.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 April 2021
Resolved 7 April 2021
Resolution: Bus bar mounted.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 17 March 2021 Resolved
Fuel tank exhaust blower motor hose taped and holed. Provide new blower hose for supply and exhaust to ensure proper ventilation of fuel tank space is achieved.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 April 2021
Resolved 7 April 2021
Resolution: New hose installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 11 March 2020 Resolved
Bilge pump auto float switch not functional. Repair in accordance with 46 CFR 176.804.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 March 2020
Resolution: Float switch renewed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 11 March 2020 Resolved
Port and stbd tachometers were not functional. Repair in accordance with 46 CFR 176.804.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 March 2020
Resolution: Tachometers repaired.
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 11 March 2020 Resolved
Current emergency drills were not logged. Log in accordance with 46 CFR 185.420.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 March 2020
Resolved 11 March 2020
Resolution: Current drills logged.
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 11 March 2020 Resolved
Emergency instructions were not provided. Provide in accordance with 46 CFR 185.510.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 March 2020
Resolved 11 March 2020
Resolution: Emergency instructions provided.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 14 May 2019 Resolved
Vessel is required to have DSC VHF radio in accordance with 46 CFR 184.502. DCS function was not installed or programmed. Prove DSC function in accordance with 46 CFR 176.816.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 June 2019
Resolved 15 May 2019
Resolution: DSC function hooked up to VHF Radio.
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 20 March 2018 Resolved
Missing 7 adult PFDs. Provide in accordance with 46CFR 180.71 Limited to 19 adult passengers.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 21 March 2018
Resolution: PFDs provided.
Engineering › Fuel Oil Service System › Valve
Issued 20 March 2018 Resolved
Emergency fuel valves do not close completely. Repair in accordance with 46 CFR 182.455.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 March 2018
Resolved 21 March 2018
Resolution: Valves close completely.
Navigation › Piloting/Steering › Magnetic Compass
Issued 29 March 2017 Resolved
Replaced Compass with servicable one.
Due 29 April 2017
Resolved 17 April 2017
Resolution: Compass was replaced.
Lifesaving › Rescue Boat › Inflated Condition
Issued 29 March 2017 Resolved
Vessels tubes are not passing exterior and baffle leak tests and overpressure test. Tubes must be repaired or replaced.
Action required: 705 - Other - as specified
Resolved 18 August 2017
Resolution: Collar renewed.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.