99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 18 March 2026
Resolved
The marine employer must have a sufficient number of alcohol testing devices readily accessible on board the vessel. Alcohol test strips aboard were expired; vessel replaced with new stock from office. 46 CFR 4.06-15 (a)
Action required: 10 - Deficiency Rectified
Resolved 19 March 2026
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 18 March 2026
Resolved
Each portable fire extinguisher on a vessel must be of an approved type. The minimum number of portable fire extinguishers required on a vessel must be acceptable to the cognizant Officer in Charge, Marine Inspection, but must not be fewer than the minimum number required by table 1 to § 181.500(b) and other provisions of this section. Vessel was missing 01 fire extinguisher required by COI; a new 3A 40BC fire extinguisher was purchased and installed. 46 CFR 181.500 (a)
Action required: 10 - Deficiency Rectified
Resolved 19 March 2026
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 18 March 2026
Resolved
A vessel not required to have a power driven fire pump by § 181.300 must have at least three 9.5 liter (21/2 gallon) buckets, with an attached lanyard satisfactory to the cognizant OCMI, placed so as to be easily available during an emergency. The words “FIRE BUCKET” must be stenciled in a contrasting color on each bucket. Vessel was missing 1 of 3 required fire buckets; missing bucket was installed aboard during inspection. 46 CFR 181.610
Action required: 10 - Deficiency Rectified
Resolved 19 March 2026
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 18 March 2026
Resolved
A space containing machinery powered by, or fuel tanks for, gasoline must have a ventilation system that complies with this section and consists of: (ii) A mechanical exhaust system consisting of at least two ventilation exhaust ducts located at the end of the space opposite from where the supply ducts are fitted, which extend to the lowest part of the bilge of the space on each side of the space, and which are led to one or more powered exhaust blowers. Vessel's rear ventilation exhaust duct in the fuel tank space is disconnected and incomplete. Make permanent repairs to restore original functionality to the rear ducting within 30 days. 46 CFR 182.460 (a) (ii)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 April 2026
Resolved 19 March 2026
Resolution: Ducting renewed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 18 March 2026
Resolved
Exhaust blower switches must be located outside of any space required to be ventilated by this section, and must be of the type interlocked with the starting switch and the ignition switch so that the blowers are started before the engine starter motor circuit or the engine ignition is energized. A red warning sign at the switch must state that the blowers must be operated prior to starting the engines for the time sufficient to insure at least one complete change of air in the space served. Vessel does not have a blower warning sign. Install signage as required for the minimum time sufficient for 1 complete air change of below deck space within 30 days. 46 CFR 182.460 (e)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 April 2026
Resolved 25 March 2026
Resolution: Received photo of blower warning sign installed at helm.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 18 March 2026
Resolved
An adult life jacket must be provided for each person carried on board a vessel. Four adult life jackets were found in unserviceable condition. Vessel provided four new adult life jackets from office. 46 CFR 180.71
Action required: 10 - Deficiency Rectified
Resolved 19 March 2026
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 18 March 2026
Resolved
Each survival craft must be:(2)Stowed so that when the vessel sinks the survival craft floats free and, if inflatable, inflates automatically. Vessel's life float was inadvertently secured to vessel and not float free. Vessel reinstalled life float to make float free. 46 CFR 180.130 (a) (2)
Action required: 10 - Deficiency Rectified
Resolved 19 March 2026
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 18 March 2026
No resolution recorded
Repairs or alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without the approval of the cognizant [name withheld] or alterations that affect the safety of the vessel include, but are not limited to: replacement, repair, or refastening of deck or hull planking, plating, and structural members; repair of plate or frame cracks; damage repair or replacement, other than replacement in kind, of electrical wiring, fuel lines, tanks, boilers and other pressure vessels, and steering, propulsion and power supply systems; alterations affecting stability; and repair or alteration of lifesaving, fire detecting, or fire extinguishing equipment.
Vessel plans to replace collar structures with a new manufacture (Inventech currently aboard, Wing being installed) on 12 April 2026. This change has implications on structural and stability approvals issued by the Marine Safety Center (MSC) Provide MSC with necessary information for review and provide MSC's final evaluation to [name withheld].46 CFR 176.700(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 May 2026 — due date passed with no resolution recorded
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 4 March 2025
Resolved
A vessel must be provided with bilge pumps in accordance with Table 182.520(a). A submersible electric bilge pump may be used provided that: The pump is listed by an independent laboratory as meeting the requirements in UL 1113. Aft bilge pump inoperable and not meeting the requirements of UL 1113. Pump requires renewal. 46CFR182.520
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 March 2025
Resolution: Bilge pump replaced with Rule 2000 (UL1113). Operating as intended.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 4 March 2025
Resolved
A flammable vapor detection system must provide a visual and audible alarm at the operating station. Flammable vapor detection system inoperable. Provide proof of operating flammable vapor detection system. 46CFR182.480(d)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 March 2025
Resolution: Display unit at helm for flammable vapor detection system replaced. Operating as intended with visual and audible alarm.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 4 March 2025
Resolved
Each vessel that operates on high seas must have on board a FCC Type Accepted Category 1, 406 MHz EPIRB, installed to automatically float free and activate. Provide proof for expiration date for hydrostatic release unit. 46CFR180.64
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 April 2025
Resolved 18 March 2025
Resolution: New Epirb HRU installed on vessel
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 4 March 2025
Resolved
Each item of lifesaving equipment determined by the marine inspector to not be in serviceable condition must be repaired or replaced. Provide (02) marked paddles for
life float. Provide proof for expiration date for
hydrostatic release unit. Vessel shall not operate more than 3 miles from shore until life float equipment and and free floating stowage requirements are met. 46CFR176.808(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 April 2025
Resolved 18 March 2025
Resolution: New Life float paddles and HRU installed on vessel
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 4 March 2025
Resolved
A vessel must carry either a first-aid kit that meets the requirements in 46 CFR 199.175(b)(10) or a kit with equivalent contents and instructions. First aid kit onboard requires renewal for expired content. 46CFR184.710
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 April 2025
Resolved 18 March 2025
Resolution: New first aid kit installed on vessel
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 7 March 2023
Resolved
A flammable vapor detection system must provide a visual and audible alarm at the operating station. The flammable vapor detection system is not working. Provide proof of operating flammable vapor detection system.
46CFR182.480(d)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 March 2023
Resolution: New detector installed.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 7 March 2023
Resolved
Exhaust blower switches must be of the type interlocked with the starting switch and the ignition switch so that the blowers are started before the engine starter motor circuit or the engine ignition is energized. The exhaust blower is not interlocked with the starting switch. Interlock exhaust blower with the starting switch.
46CFR182.460(e)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 March 2023
Resolution: Ignition interlock wired into blower. All sat.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 7 March 2023
Resolved
The minimum number of portable fire extinguishers required on a vessel must not be fewer than the minimum number required by Table 181.500(b). Vessel needs an additional 2-A rated portable fire extinguisher for the Accommodation space.
46CFR181.500(a)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 March 2023
Resolution: New extinguisher provided.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 7 March 2023
Resolved
A vessel must be fitted with ground tackle and mooring lines necessary for the vessel to be safely anchored or moored. The anchor is broken and unusable. Repair or replace the anchor.
46CFR184.300
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 7 March 2023
Resolution: Anchor flukes properly installed.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 7 March 2023
Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection giving consideration to necessary facilities for passengers and crew. The port quarter ladder bracket is wasted. Repair or replace bracket.
46CFR177.100
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 April 2023
Resolved 26 March 2023
Resolution: Bracket repaired.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 1 March 2022
Resolved
Exhaust blower switches must be located outside of any space required to be ventilated by this section, and must be of the type interlocked with the starting switch and the ignition switch so that the blowers are started before the engine starter motor circuit or the engine ignition is energized. Ventilation not interlocked with engine starter motor. Install and demonstrate interlocked system.
46 CFR 182.460(e)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 31 March 2022
Resolution: Interlock installed.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 1 March 2022
Resolved
The marine employer must have a sufficient number of alcohol testing devices readily accessible on board the vessel. Vessel's alcohol test strips are expired. Provide alcohol test strips.
46 CFR 4.06-15
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 28 March 2022
Resolution: Test strips provided.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 1 March 2022
Resolved
Electrical equipment on a vessel must be installed to protect the vessel from electrical hazards. Clean off corroded terminals and bus bar above fuel tank compartment.
46 CFR 183.200(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 28 March 2022
Resolution: New terminals installed.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 1 March 2022
Resolved
An internal structural examination consists of a complete examination of the vessel's main strength members, including the major internal framing, the hull plating and planking, voids, and ballast, cargo, and fuel oil tanks. Prepare fuel tank and area under fuel tank for inspection.
46 CFR 176.610(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 25 March 2022
Resolution: Fuel tank space made ready for inspection.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 1 March 2022
Resolved
Repairs or alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without the approval of the cognizant OCMI, except during an emergency. Crack at strake stbd side. Submit repair proposal for approval by Marine Inspector.
46 CFR 176.700(a)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 11 March 2022
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 1 March 2022
Resolved
Repairs or alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without the approval of the cognizant OCMI, except during an emergency. Crack at bow on central vertical keel plating. Submit repair proposal for approval by Marine Inspector.
46 CFR 176.700(a)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 11 March 2022
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 1 March 2022
Resolved
Repairs or alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without the approval of the cognizant OCMI, except during an emergency. Crack at bow on tube. Submit repair proposal for approval by Marine Inspector.
46 CFR 176.700(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 11 March 2022
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 1 March 2022
Resolved
Repairs or alterations to the hull, machinery, or
equipment that affect the safety of the vessel must not
be made without the approval of the cognizant OCMI, except during an emergency. Crack at strake stbd aft under trailer brackets. Submit repair proposal for approval by Marine Inspector.
46 CFR 176.700(a)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 11 March 2022
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 1 March 2022
Resolved
Repairs or alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without the approval of the cognizant OCMI, except during an emergency. Crack on port aft bimini. Submit repair proposal for approval by Marine Inspector.
46 CFR 176.700(a)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 11 March 2022
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 1 March 2022
Resolved
25 Mar 2022 - Tank space soft patch removed for tank space inspection. 4 cracks located on brackets that support tank. Remove fuel tank for deck inspection. Repair 04 cracked brackets once fuel tank removed from space. Complete within 30 days - Due 25 Apr 2022.
46 CFR 176.610(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 April 2022
Resolved 21 April 2022
Resolution: 05 tank support cracks welded.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 30 March 2021
Resolved
Provide Letter of Regulatory Compliance (LORC) for Reliable Drug Testing Services Consortium.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 April 2021
Resolved 6 April 2021
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 30 March 2021
Resolved
Update EAP Information to reflect current changes to DAPI program (i.e., Provide EAP information posted in vessel common space; Identify SAP and update EAP information with contact information; Hot-line information, etc).
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 April 2021
Resolved 6 April 2021
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 30 March 2021
Resolved
Provide the DAPI covered employees list for BWR vessels. Confirm all employees have record of preemployment test or subject to random since COVID-19 shutdown.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 April 2021
Resolved 6 April 2021
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 30 March 2021
Resolved
An EAP training program must be conducted for the employer's crewmembers and supervisory personnel. The training program must include at least the following elements: the effects and consequences of drug and alcohol use on personal health, safety, and work environment; the manifestations and behavioral cues that may indicate drug and alcohol use and abuse; and documentation of training given to crewmembers and the employer's supervisory personnel (continued on second page). Supervisory personnel must receive at least 60 minutes of training. Provide proof of completed EAP training for all personnel.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 April 2021
Resolved 6 April 2021
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 30 March 2021
Resolved
Confirm Blue Water Rafting's policy regarding employment for mariner's who have tested positive on any of the five types of DOT chemical tests and the MRO return to work process.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 April 2021
Resolved 6 April 2021
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 17 March 2021
Resolved
Life Float light not operating as designed. Provide operational life float light.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 March 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 17 March 2021
Resolved
Aft bilge pump not operational. Provide working aft bilge pump.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 March 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 17 March 2021
Resolved
Visual auto bilge indicator not operational for aft bilge pump. Provide visual auto bilge indicator at helm for aft bilge pump.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 March 2021
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 17 March 2021
Resolved
Master and deckhand did not have Marine Radio Operator Permit (MROP). Provide master and/or crew who has valid MROP.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 April 2021
Resolved 27 April 2021
Resolution: MROP Provided.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 17 March 2021
Resolved
Hydraulic hose for port side steering ram showing inner metallic braiding corrosion that is causing hose deformation. Provide new port side hydraulic hose.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 April 2021
Resolved 7 April 2021
Resolution: New hose installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 17 March 2021
Resolved
Hydraulic hose for port side engine fuel showing inner metallic braiding corrosion that is causing hose deformation. Provide new port side engine fuel hose.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 April 2021
Resolved 7 April 2021
Resolution: New hose installed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 17 March 2021
Resolved
Battery selector in battery compartment not secured/mounted. Make battery selector secure/mounted.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 April 2021
Resolved 7 April 2021
Resolution: Battery selectyor mounted.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 17 March 2021
Resolved
Bus bar under helm not secured/mounted. Secure/mount bus bar.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 April 2021
Resolved 7 April 2021
Resolution: Bus bar mounted.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 17 March 2021
Resolved
Fuel tank exhaust blower motor hose taped and holed. Provide new blower hose for supply and exhaust to ensure proper ventilation of fuel tank space is achieved.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 April 2021
Resolved 7 April 2021
Resolution: New hose installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 11 March 2020
Resolved
Bilge pump auto float switch not functional. Repair in accordance with 46 CFR 176.804.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 March 2020
Resolution: Float switch renewed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 11 March 2020
Resolved
Port and stbd tachometers were not functional. Repair in accordance with 46 CFR 176.804.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 March 2020
Resolution: Tachometers repaired.
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 11 March 2020
Resolved
Current emergency drills were not logged. Log in accordance with 46 CFR 185.420.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 March 2020
Resolved 11 March 2020
Resolution: Current drills logged.
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 11 March 2020
Resolved
Emergency instructions were not provided. Provide in accordance with 46 CFR 185.510.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 March 2020
Resolved 11 March 2020
Resolution: Emergency instructions provided.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 14 May 2019
Resolved
Vessel is required to have DSC VHF radio in accordance with 46 CFR 184.502. DCS function was not installed or programmed. Prove DSC function in accordance with 46 CFR 176.816.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 June 2019
Resolved 15 May 2019
Resolution: DSC function hooked up to VHF Radio.
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 20 March 2018
Resolved
Missing 7 adult PFDs. Provide in accordance with 46CFR 180.71 Limited to 19 adult passengers.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 21 March 2018
Resolution: PFDs provided.
Engineering › Fuel Oil Service System › Valve
Issued 20 March 2018
Resolved
Emergency fuel valves do not close completely. Repair in accordance with 46 CFR 182.455.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 March 2018
Resolved 21 March 2018
Resolution: Valves close completely.
Navigation › Piloting/Steering › Magnetic Compass
Issued 29 March 2017
Resolved
Replaced Compass with servicable one.
Due 29 April 2017
Resolved 17 April 2017
Resolution: Compass was replaced.
Lifesaving › Rescue Boat › Inflated Condition
Issued 29 March 2017
Resolved
Vessels tubes are not passing exterior and baffle leak tests and overpressure test. Tubes must be repaired or replaced.
Action required: 705 - Other - as specified
Resolved 18 August 2017
Resolution: Collar renewed.