Records from 1997 to 1998. Most recent: inspection, 19 September 1998.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Documentation
Issued 19 September 1998
No resolution recorded
Provide flag administration acceptance of all officers licences or equivalent.
Condition: Unknown
Due 19 September 1998 — due date passed with no resolution recorded
Deck/Cargo
Issued 4 August 1998
Resolved
THE ESCAPE HATCH FROM THE STEERING ROOM TO THE WEATHER DECK CANNOT BE OPENED FOR THE INSIDE.
Condition: Unknown
Due 23 September 1998
Resolved 23 September 1998
Construction/Loadline
Issued 4 August 1998
Resolved
The deck overboard drian piping on the port side, aft bulkhead is holed allowing the free communciation of water into the space.
Condition: Unknown
Due 23 September 1998
Resolved 23 September 1998
Lifesaving
Issued 4 August 1998
Resolved
The sea valve on the port lifeboat is inoperable.
Condition: Unknown
Due 23 September 1998
Resolved 23 September 1998
Lifesaving
Issued 4 August 1998
Resolved
The bilge pump on the port lifeboat is inoperative.
Condition: Unknown
Due 23 September 1998
Resolved 23 September 1998
Electrical
Issued 4 August 1998
Resolved
Mounting bracket for self igniting lights on both port and starboard side amidship deteriorated.
Condition: Unknown
Due 23 September 1998
Resolved 23 September 1998
Construction/Loadline
Issued 4 August 1998
Resolved
The salt water discharge piping for the Marine Growth System is holed forward of the isolation valve.
Condition: Unknown
Due 23 September 1998
Resolved 23 September 1998
Lifesaving
Issued 4 August 1998
Resolved
The forward and aft limit switches on the starboard lifeboat davit is inoperative.
Condition: Unknown
Due 23 September 1998
Resolved 23 September 1998
Lifesaving
Issued 4 August 1998
Resolved
The oar crutches on the starboard lifeboat are not attached to vessel.
Condition: Unknown
Due 23 September 1998
Resolved 23 September 1998
Lifesaving
Issued 4 August 1998
Resolved
Bilge plugs on both port and starboard lifeboats are not attached to vessel.
Condition: Unknown
Due 23 September 1998
Resolved 23 September 1998
Unknown
Issued 30 April 1998
Resolved
Ventilation duct at top of ladder on 03 deck interior deck house has seperated at bulkhead interface. Vessel is required to correct this non- adherence to Solas 74 Amended I/11 prior to next U.S. port.
Condition: Unknown
Due 6 August 1998
Resolved 6 August 1998
Unknown
Issued 30 April 1998
Resolved
Ventilation fan located in 01 deck ships office missing guard. Vessel is required to correct this non-adherence to Solas 60 II-C/27 and Solas 74 Amended I/11 prior to next U.S. port.
Condition: Unknown
Due 6 August 1998
Resolved 6 August 1998
Electrical
Issued 30 April 1998
Resolved
Air-con unit located in the fan room missing guard thereby creating a risk of electrical shock hazard. Vessel is required to correct this non- adherence to Solas 60 II-C/27 prior to next U.S. port.
Condition: Unknown
Due 6 August 1998
Resolved 6 August 1998
Unknown
Issued 30 April 1998
Resolved
Ventilation exhaust pipe from bag filter room and exhaust pipe cover gasketdeteriorated. Vessel is required to correct this non-adherence to Solas 74Amended I/11 prior to next U.S. port.
Condition: Unknown
Due 6 August 1998
Resolved 6 August 1998
Accommodation/Occupational Safety
Issued 30 April 1998
Resolved
Top step on forward starboard side ladder leading from main deck to focsuledeteriorated. Vessel is required to correct this non-adherence to ICLL 66 II/25 prior to next U.S. port.
Condition: Unknown
Due 6 August 1998
Resolved 6 August 1998
Electrical
Issued 30 April 1998
Resolved
Electrical junction box mounted on focsule portside vent in way of portsideladder missing cover. Vessel is required to correct this non-adherence to SOLAS 60 II-C/27 prior to next U.S. port.
Condition: Unknown
Due 6 August 1998
Resolved 6 August 1998
Accommodation/Occupational Safety
Issued 30 April 1998
Resolved
Hand rail on portside focsule stairway snapped off; thereby creating risk of injury to crew. Vessel is required to correct this non-adherence to SOLAS 74 amended I/11 prior to next U.S. port.
Condition: Unknown
Due 6 August 1998
Resolved 6 August 1998
Lifesaving
Issued 30 April 1998
Resolved
Port and starboard davits for lifeboats missing tripping line cleats. Vessel to correct to SOLAS 74 amended I/11, III/19 prior to next U.S. port.
Condition: Unknown
Due 6 August 1998
Resolved 6 August 1998
Electrical
Issued 30 April 1998
Resolved
Large wet-cell battery improperly stowed in aft steering. Subject battery not secured to prevent movement in heavy seas and not contained within corrosion resistant battery box. Vessel required to correct to SOLAS 60 II-C/27(a)(viii) prior to next U.S. port.
Condition: Unknown
Due 6 August 1998
Resolved 6 August 1998
Lifesaving
Issued 30 April 1998
Resolved
Port and Starboard lifeboats missing tripping lines. Vessel is required tocorrect this non-adherence to SOLAS 74 amended I/11, III/19 prior to next U.S. port.
Condition: Unknown
Due 6 August 1998
Resolved 6 August 1998
Accommodation/Occupational Safety
Issued 6 February 1998
Resolved
There was exessive grease on galley range hood._x001C_ _x001C_ _x001C_ ILO 147
Condition: Unknown
Due 6 August 1998
Resolved 6 August 1998
Accommodation/Occupational Safety
Issued 6 February 1998
Resolved
The range gas burner fuel line is made of an improper material._x001C_ _x001C_ _x001C_ SOLAS 60 II/49(b)
Condition: Unknown
Due 6 August 1998
Resolved 6 August 1998
Construction/Loadline
Issued 6 February 1998
Resolved
Walkway from the lifeboat to the bow has a 3 inch fracture where walkway isbolted to lifeboat deck on the starboard._x001C_ _x001C_ ICLL 66.
Condition: Unknown
Due 6 August 1998
Resolved 6 August 1998
Lifesaving
Issued 6 February 1998
Resolved
Vessel did not have the required 50% self igniting lights as per vessels Safety Equipment Form E.
Condition: Unknown
Due 6 August 1998
Resolved 6 August 1998
Electrical
Issued 6 February 1998
Resolved
Electrical matting was missing from infront of bag filter control panel, starboard side battery room, and the electric room panel on the 3rd deck, the cargo room, and the engine control room panel._x001C_ SOLAS 60 II/27(a)(ii).
Condition: Unknown
Due 6 August 1998
Resolved 6 August 1998
Accommodation/Occupational Safety
Issued 6 February 1998
Resolved
Vessel did not have a clearly defined garbage plan as required under 33CFR151.57._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 6 August 1998
Resolved 6 August 1998
Fire Fighting
Issued 6 February 1998
Resolved
The fire hose box located at the bow is inaccessible. SOLAS 74 amended II- 2/21
Condition: Unknown
Due 6 August 1998
Resolved 6 August 1998
Electrical
Issued 6 February 1998
Resolved
Light fixtures were missing covers and/or guards. E.G. 2nd deck drystores,spare room (customs), spare room forward of customs room, overhead portsideaft, jumper & oil skin room, 3rd deck landing of engine room, aft of battery room, and fixtures forward of main deck entrance, port & starboard.
Condition: Unknown
Due 6 August 1998
Resolved 6 August 1998
Engineering
Issued 6 February 1998
Resolved
Vent screeen were missing from the port and starboard fuel oil and lube oilvents on the 2nd deck. SOLAS 74 (amended) I/11.
Condition: Unknown
Due 6 August 1998
Resolved 6 August 1998
Engineering
Issued 6 February 1998
Resolved
Vent closures for the lube oil, fuel oil, and the aft galley vents do not close or operate properly in the event of a fire. SOLAS 60 II/47(a)
Condition: Unknown
Due 6 August 1998
Resolved 6 August 1998
Electrical
Issued 6 February 1998
Resolved
Wires were improperly dead ended in the Electric room 3rd deck, and port side above entrance to bag filter room. SOLAS 60 II/27
Condition: Unknown
Due 6 August 1998
Resolved 6 August 1998
Lifesaving
Issued 6 February 1998
Resolved
The port side aft ring buoies grab line needs to be permently repaired or replaced. SOLAS 60 III/21(d)
Condition: Unknown
Due 6 August 1998
Resolved 6 August 1998
Electrical
Issued 6 February 1998
Resolved
The main light switch for the galley has loose wire._x001C_ _x001C_ _x001C_ SOLAS 60 II/27
Condition: Unknown
Due 6 August 1998
Resolved 6 August 1998
Electrical
Issued 25 May 1997
Resolved
Throughout the vessel, lights did not have protective covers (wire mesh or plastic cover) as required SOLAS 60 II/27._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 6 August 1998
Resolved 6 August 1998
Unknown
Issued 9 April 1997
Resolved
Throughout the vessel the lights were missing light covers. SOLAS 60 II/27
Condition: Unknown
Due 26 June 1997
Resolved 6 August 1998
Documentation
Issued 9 April 1997
Resolved
Missing letter of designation for the person-in-charge of fuel transfers._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 25 May 1997
Resolved 25 May 1997
Unknown
Issued 9 April 1997
Resolved
No retroreflective material on bottom of the lifeboats. Both lifeboats arenot self-righting._x001C_ SOLAS 74 amended III/30.2.7_x001C_ _x001C_
Condition: Unknown
Due 25 May 1997
Resolved 25 May 1997
Unknown
Issued 9 April 1997
Resolved
The quick-release mechanism for the smoke/light attachment on the bridge- wing lifebuoys did not operate._x001C_ SOLAS 60 III/21B._x001C_ _x001C_
Condition: Unknown
Due 25 May 1997
Resolved 25 May 1997
Accommodation/Occupational Safety
Issued 9 April 1997
Resolved
The marine sanitation device was not marked or labelled, and the crew did not know the type. The MSD was secured while in port._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 25 May 1997
Resolved 25 May 1997
Unknown
Issued 9 April 1997
Resolved
The vents for the battery room could not be used due to the over-abundance of paint on the handles. The handles could not be turned. SOLAS 74 Amended II-2/18.7._x001C_ _x001C_
Condition: Unknown
Due 25 May 1997
Resolved 25 May 1997
Unknown
Issued 9 April 1997
Resolved
Portside main deck watertight door has wasted hinge. Unable to open the door. ILLC 66 Annex 1/12_x001C_ _x001C_
Condition: Unknown
Due 25 May 1997
Resolved 25 May 1997
Unknown
Issued 9 April 1997
Resolved
Compressed gas cylinders throughout the vessel secured with line and stowedon the steel deck. SOLAS 60 I/2_x001C_ _x001C_ _x001C_
Condition: Unknown
Due 25 May 1997
Resolved 25 May 1997
Documentation
Issued 9 April 1997
Resolved
Oil transfer procedures missing: cargo info card, procedures for emptying discharge containment, tending vessel's mooring lines, procedures for emergency shutdown and communication, topping off tanks procedures, securing valves and reporting oil/hazmat discharges into the water._x001C_
Condition: Unknown
Due 25 May 1997
Resolved 25 May 1997
Unknown
Issued 9 April 1997
Resolved
Engine room dampers not marked nor were they able to move due to the paint.SOLAS 60 II/2_x001C_ _x001C_ _x001C_
Condition: Unknown
Due 26 May 1997
Resolved 26 May 1997