MAURY USCG vessel records Sign in
← All vessels

ILWACO INDIAN

ILWACO INDIAN is a 1967 passenger vessel (inspected). The Coast Guard has recorded 70 inspections since 1985, most recently in November 2024, along with 111 deficiencies — 1 with no resolution recorded — and 2 casualty investigations between 2020 and 2022.

Records from 1985 to 2024. Most recent: inspection, 1 November 2024.

Built
1967
Last inspected
1 November 2024
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WCY8685
Flag
UNITED STATES
367390110
Maury page id
psix-45482

Inspections, by type

…with no type recorded10
Years with a record 36 calendar years (1985–2024)
The 70 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)40.0 ft × 14.1 ft × 6.0 ft
Registered tonnagegross 24 / net 16
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderRON RAWSON INC · REDMOND WA, UNITED STATES · built 1967
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portNEWPORT, OR
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 29 November 2025 · expires 30 November 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it24 - Regulatory (Subpart C or D), Gross Ton
16 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WCY8685MMSI 367390110 · active · voluntarily equipped · granted 31 January 2019, expires 3 February 2029
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

NEVER AGAIN IX Commercial Fishing Vessel · MISLE 1292103 · 27 June 2021 · activity 7262172

Inspection history · 70

1 November 2024 Hull Examination · Administrative Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8032649
17 October 2023 COI Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7810206
11 October 2023 Administrative Inspection
Administrative · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7806734
16 November 2022 DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7595026
31 October 2022 Hull Examination
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7586319
29 March 2022 In-Service Inspection · Deficiency Check
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7421156
29 March 2022 Type not recorded
No type recorded · Station Yaquina Bay · USCG Northwest District (CGD-NW) · Activity 7421449
29 March 2022 Type not recorded
No type recorded · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7425785
10 December 2021 DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7367303
27 June 2021 Type not recorded
No type recorded · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7262172
20 October 2020 DAPI Audit · Annual Inspection · Hull Examination
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7100543
16 August 2020 Type not recorded
No type recorded · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7060828
15 August 2020 Examination of Repairs · Deficiency Check
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7034109
3 October 2019 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6826300
27 February 2019 Hull Examination
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6634983
16 August 2018 DAPI Audit · COI Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6525177
1 November 2017 Deficiency Check · Examination of Repairs
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6308675
4 May 2017 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6308667
7 February 2017 Deficiency Check · Hull Examination
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6092632
24 May 2016 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 5886425
10 August 2011 Deficiency Check
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 4111388
8 February 2011 Hull Examination
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 3938633
24 March 2010 Administrative Inspection · Deficiency Check
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3703424
20 April 2009 Annual Inspection · Deficiency Check
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3459938
11 February 2009 Hull Examination
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3417436
5 February 2008 Deficiency Check · COI Inspection
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3150589
11 June 2007 Administrative Inspection
Administrative · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2958607
19 March 2007 Deficiency Check
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2900093
1 March 2007 Annual Inspection
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2880771
20 February 2007 Hull Examination
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2880743
27 April 2006 Annual Inspection
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2628634
22 February 2005 Hull Examination · Annual Inspection · Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2294036
25 March 2004 Annual Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2027447
3 February 2003 COI Inspection · Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1727263
15 January 2002 Annual Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1475747
9 August 2001 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 17097
5 April 2001 Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1064676
23 January 2001 Re-Inspection · Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1382160
22 February 2000 Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1046632
26 January 2000 COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1391204
3 September 1999 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 157758
18 July 1999 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 42066
8 April 1999 Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 786987
10 March 1999 Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 806907
28 January 1999 Re-Inspection · Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1432052
3 February 1998 Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1398838
10 June 1997 Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1110097
6 March 1997 Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1104256
29 January 1997 Hull Examination · COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1458372
19 April 1996 Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1081622
2 February 1996 Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1449903
5 April 1995 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1151237
8 March 1995 Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1170897
17 February 1995 Hull Examination · Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1425555
2 February 1994 COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1454054
19 February 1993 Re-Inspection · Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1376936
21 October 1992 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 937987
1 April 1992 Drydock Extension
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 955812
20 March 1992 Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 945990
26 February 1992 Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 961307
28 March 1991 Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 918497
19 February 1991 Hull Examination · COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1216707
10 April 1990 Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 921492
26 February 1990 Hull Examination · Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 911863
24 February 1989 Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1196420
20 February 1989 Re-Inspection · Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1196739
22 February 1988 Hull Examination · COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1025854
23 February 1987 Hull Examination · Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1029148
25 February 1986 Credit Drydock · Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 989848
25 February 1985 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1286006

Deficiency record · 111

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 13 January 2025 No resolution recorded
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations. Engine is inoperable due to water entering all cylinders.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 1 November 2024 Resolved
A drydock examination conducted in compliance with § 176.600 must be conducted while the vessel is hauled out of the water or placed in a drydock or slipway. Vessel is not operating and missed DDX
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 January 2025
Resolution: Completed Drydock exam.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 11 October 2023 Resolved
You must submit your written application for renewal of a Certificate of Inspection to the OCMI at least 30 days prior to the expiration of the Certificate of Inspection. Vessel failed to submit application for renewal and operated beyond expiration of COI. Vessel is restricted from commercial service authorized by the COI until new COI is issued to vessel.
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 November 2023
Resolved 17 October 2023
Resolution: Conducted COI inspection and issued COI.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 29 March 2022 Resolved
VSL EXPERENCED LOSS OF POWER DUE TO FAILED OIL COOLER FOR THE DUAL DISC TRANSMISSION RESULTING IN AN OVERHEAT OF THE TRANSMISSION.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 April 2022
Resolved 10 May 2022
Resolution: Installed new transmission and oil cooler. Conducted satisfactory sea trial.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 3 October 2019 Resolved
A vessel must be provided w/ bilge pumps IAW table 182.520(a). The bilge pump in the steering compartmentwas found to be pumping inadequately and less than the minimum capacity required per pumpin table 182.520(a).
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 October 2019
Resolution: Pump replaced.
10 - Safety of Navigation › N/A - No Subsystem › Record of drills and steering gear tests
Issued 3 October 2019 Resolved
Abandon Ship and MOB drills and training must be logged IAW 185.520. Log all drills & training.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 8 October 2019
Resolution: Reviewed drill procedures, and verified properly logged.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 3 October 2019 Resolved
Fire fighting drills & training must be logged IAW 185.520. Log all drills and training.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 8 October 2019
Resolution: Verified logging of drills etc.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 3 October 2019 Resolved
EPIRB shall be tested monthly and logged.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 8 October 2019
Resolution: Verified proper logging.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 3 October 2019 Resolved
Vessel must carry adequate & up-to-date charts.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 8 October 2019
Resolution: New charts on board.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 3 October 2019 Resolved
Vessel must have three 2.5 gallon buckets w/ an attached lanyard.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 8 October 2019
Resolution: Fire buckets provided.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 3 October 2019 Resolved
Provide proof that bilge ovbd discharge has a valve or non-return valve installed.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 8 October 2019
Resolution: Overboard valve available.
Engineering › Bilge Water Management System › Pump
Issued 4 May 2017 Resolved
Demonstrate proper operation of fixed bilge system. IAW 46 CFR 182.520
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 June 2017
Resolved 11 May 2017
Resolution: Engine driven pump repaired and operated normally.
Engineering › Bilge Water Management System › Pump
Issued 4 May 2017 Resolved
Mount bilge submersible pump in lazarette, IAW 46 CFR 182.520
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 June 2017
Resolved 11 May 2017
Resolution: Pump mounted.
Fire Fighting › Fire Bucket › Quantity
Issued 4 May 2017 Resolved
Provide three fire buckets, IAW 46 CFR 181.610
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 June 2017
Resolved 11 May 2017
Resolution: Buckets provided.
Engineering › Sea-water System (primary cooling) › Valve
Issued 4 May 2017 Resolved
Provide proper bonding of metalic sea valves on FRP vessel.
Due 4 June 2017
Resolved 11 May 2017
Navigation › Piloting/Steering › Marine Charts
Issued 4 May 2017 Resolved
Provide nautical charts for operating area, IAW 46 CFR 184.420
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 June 2017
Resolved 11 May 2017
Resolution: Charts provided.
Construction/Loadline › Structures › Deck Plating
Issued 7 February 2017 Resolved
Make permanent repairs to wasting and delaminating deck covering and structural members above engine room, and lazzarette areas. Repairs are to address any affected deck members and coverings. Proposal and repairs to be made to the satisfaction of the attending Coast Guard marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 November 2017
Resolved 15 May 2018
Resolution: Repairs completed.
Construction/Loadline › Structures › Deck Plating
Issued 7 February 2017 Resolved
Identify and make permanent repairs to leaking areas iwo engine room vents, and along railings around salon.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 April 2017
Resolved 15 May 2018
Resolution: Repairs complete.
Engineering › Sea-water System (primary cooling) › Valve
Issued 7 February 2017 Resolved
Replace head sea suction gate valve.
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 March 2017
Resolved 9 February 2017
Resolution: Witnessed replacement valve installation.
Engineering › Sea-water System (primary cooling) › Valve
Issued 7 February 2017 Resolved
Replace wash down pump sea suction valve.
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 March 2017
Resolved 9 February 2017
Resolution: Witnessed installation of new sea valve.
Engineering › Shafting/Propeller Arrangements › Stern Tube Bearing
Issued 7 February 2017 Resolved
Replace stern tube bearing.
Action required: 705 - Other - as specified
Due 7 March 2017
Resolved 9 February 2017
Resolution: Witnessed replacement of bearing.
Engineering › Steering Gear System › Hand Pump
Issued 24 May 2016 Resolved
Hand tiller showed signs of corrosion and wastage during operational testing.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 June 2016
Resolved 25 May 2016
Resolution: Rec'd picture of hand tiller.
Lifesaving › Inflatable Buoyant Apparatus › Not on Board
Issued 24 March 2010 Resolved
Vessel passenger count reduced to 14 passengers and 02 crew on a Coastwise route and 08 passengers and 02 crew on an Oceans route until 25 man IBA is back onboard. Presently only a 10 man IBA is onboard.
Action required: 705 - Other - as specified
Resolved 26 March 2010
Resolution: 25 man IBA is back onboard.
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 20 April 2009 Resolved
Provide two alcohol test kits prior to operating with passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 April 2009
Documentation › Markings/Placards › Lifejacket Placard
Issued 20 April 2009 Resolved
Properly post lifejacket donning placard IAW 46 CFR 185.516 prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 April 2009
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 20 April 2009 Resolved
Prove proper operation of stern light IAW Nav Rules of the Road.
Due 23 April 2009
Resolved 22 April 2009
Communications › Alarms/Indicators › High Water Alarm
Issued 20 April 2009 Resolved
Prove proper operation of bilge high level alarm IAW 46 CFR 182.530 prior to operating with passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 April 2009
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 20 April 2009 Resolved
Properly conduct and log u/w drills IAW 46 CFR 185.728/.520/.524 prior to operating with passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 April 2009
Resolved 22 April 2009
Lifesaving › Lifebuoys › Serviceable
Issued 20 April 2009 Resolved
Replace ring lifebuoy and lifeline and waterlight line IAW 46 CFR 180 prior to operating with passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 April 2009
Communications › Radio Communications › EPIRB
Issued 20 April 2009 Resolved
Properly replace hydrostatic release on EPIRB IAW 46 CFR 180/185 and log test in vessel log.
Due 23 April 2009
Resolved 22 April 2009
Navigation › Piloting/Steering › Coast Guard Light List
Issued 20 April 2009 Resolved
Provide updated publications IAW 46 CFR 184.420
Due 23 April 2009
Resolved 22 April 2009
Navigation › Piloting/Steering › Marine Charts
Issued 20 April 2009 Resolved
Provide documented proof that charts are being updated IAW 46 CFR 184.420
Due 23 April 2009
Resolved 22 April 2009
Electrical › Electrical Distribution System (service) › Wiring
Issued 20 April 2009 Resolved
Properly support electrical wires every 24 inches IAW 46 CFR 183
Due 23 April 2009
Resolved 22 April 2009
Electrical › Electrical Distribution System (service) › Wiring
Issued 20 April 2009 Resolved
Properly replace individual electrical wires with proper marine cable IAW 46 CFR 183
Due 23 April 2009
Resolved 22 April 2009
Communications › Alarms/Indicators › High Water Alarm
Issued 5 February 2008 Resolved
Properly repair bilge high level alarm in lazaret.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 March 2008
Lifesaving › Hand Flares › Expired
Issued 5 February 2008 Resolved
Replace six expired hand held smoke flares.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 March 2008
Navigation › Piloting/Steering › Marine Charts
Issued 5 February 2008 Resolved
Provide documentation that charts are being updated.
Due 5 March 2008
Resolved 11 March 2008
Lifesaving › Lifejacket/PFD (General) › Lights
Issued 5 February 2008 Resolved
Replace and prove proper operation of water lights on 03 adult life-jackets and 01 Childs lifejacket. Passenger count reduced by 03 adults and 01 child until proper operation can be proven.
Due 5 March 2008
Resolved 5 February 2008
Engineering › Fuel Oil Storage/Transfer System › Ventilation
Issued 5 February 2008 Resolved
Replace four fuel screens with proper 30x30 mesh screen.
Due 5 March 2008
Resolved 11 March 2008
Stability › Unintentional Flooding › General
Issued 5 February 2008 Resolved
Tighten or replace hose clamp on sink drain.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 March 2008
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 5 February 2008 Resolved
Provide documented proof that crewmember is enrolled in a D&A testing program.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 March 2008
Personnel › Certificates/Documents/Licenses › License, Operator
Issued 5 February 2008 Resolved
Provide proof of captains license.
Due 5 March 2008
Resolved 11 March 2008
Resolution: Company provided another captain until such time as the normal captain could obtain new license.
Electrical › Electrical Distribution System (service) › Wiring
Issued 5 February 2008 Resolved
Properly dead end or remove all dead end wires.
Due 5 March 2008
Resolved 11 March 2008
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 5 February 2008 Resolved
Provide two alcohol test kits onboard.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 February 2008
Engineering › Bilge Water Management System › Piping
Issued 1 March 2007 Resolved
Install long hose on portable bilge pump so that water can be removed from every space and discharged over the side.
Action required: 705 - Other - as specified
Resolved 2 March 2007
Lifesaving › Hand Flares › Expired
Issued 1 March 2007 Resolved
Provide six hand held red flares prior to commercial operation.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 March 2007
Engineering › Bilge Water Management System › Interface Detector
Issued 1 March 2007 Resolved
Properly repair light on engine room high level alarm indicator.
Action required: 705 - Other - as specified
Resolved 2 March 2007
Communications › Radio Communications › EPIRB
Issued 1 March 2007 Resolved
Replace battery on EPIRB. Vessel restricted to less than 3nm until cleared.
Action required: 705 - Other - as specified
Resolved 19 March 2007
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 1 March 2007 Resolved
Properly attach life ring water light around the body of the life ring.
Action required: 705 - Other - as specified
Resolved 2 March 2007
Fire Fighting › Ventilation Systems › Ducts
Issued 1 March 2007 Resolved
Provide designated items to close vents to ER in case of fire.
Action required: 705 - Other - as specified
Resolved 19 March 2007
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 1 March 2007 Resolved
Replace three adult life jackets. Vessel passenger count reduced to 29 until life jackets are replaced.
Action required: 705 - Other - as specified
Resolved 2 March 2007
Lifesaving › Lifebuoys › Serviceable
Issued 17 February 2005 Resolved
Renew ring buoy. Provide 60 ft of line and a 3-6 ft lanyard for light. 46 CFR 180.70. Correct to the satisfaction of the attending MI.
Condition: Improper/Lack of Maintenance
Due 17 March 2005
Resolved 22 February 2005
Resolution: New ring placed in service with proper markings and line.
Engineering › Bilge Water Management System › Strainer
Issued 17 February 2005 Resolved
Renew bilge strainers on fixed bilge system throughout. Strainer to be 3x the diameter of the pipe min. 46 CFR 182.510(b). Correct to the satisfaction of the attending MI.
Condition: Improper/Lack of Maintenance
Due 17 March 2005
Resolved 22 February 2005
Resolution: Renewed.
Engineering › Fuel Oil Service System › Piping
Issued 17 February 2005 Resolved
Address leak in aft fuel tank shut off valve. 46 CFR 182.455. Correct to the satisfaction of the attending [name withheld] PRIOR TO PASSENGER CARRIAGE.
Condition: Improper/Lack of Maintenance
Due 17 March 2005
Resolved 17 February 2005
Resolution: Corrected on scene.
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 17 February 2005 Resolved
Renew retroreflective tape on 03 Kapok Type I PFDs. 46 CFR 180.78. Correct to the satisfaction of the attending MI.
Condition: Improper/Lack of Maintenance
Due 17 March 2005
Resolved 22 February 2005
Resolution: New Type I PFDs placed on board.
Engineering › Freshwater System (jacketwater cooling) › Hose
Issued 17 February 2005 Resolved
Renew hose on main MDE cooling line downstream of strainer. Renew hose at PTO (Jabsco) pump. Renew with approved type hoses. 46 CFR 182.410. Correct to the satisfaction of the attending MI.
Condition: Improper/Lack of Maintenance
Due 17 March 2005
Resolved 22 February 2005
Resolution: New hoses installed.
Engineering › Bilge Water Management System › Pump
Issued 17 February 2005 Resolved
Make submersible (Rule) pump in E/R stationary. 46 CFR 182.520(e). Correct to the satisfaction of the attending MI.
Condition: Improper Installation
Due 17 March 2005
Resolved 22 February 2005
Resolution: Corrected.
Navigation › Piloting/Steering › Magnetic Compass
Issued 17 February 2005 Resolved
Make magnetic compass light (cabin and fly bridge) operate as required. 46 CFR 184.402. Correct to the satisfaction of the attending MI.
Condition: Improper Installation
Due 17 March 2005
Resolved 22 February 2005
Resolution: Corrected.
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 17 February 2005 Resolved
re-new Coast Pilot Vol. 7 and provide 2005 Tide/Current Tables. 46 CFR 184.420. Correct to the satisfaction of the attending MI.
Condition: Unknown
Due 17 March 2005
Resolved 22 February 2005
Resolution: Corrected.
Engineering › Diesel Engine (propulsion-direct drive) › Injector (fuel injection)
Issued 17 February 2005 Resolved
Prove proper operation of MDE, associated gauges, SSB and fixed fire fighting system to the satisfaction of the attending [name withheld] was recently overhauled and is required to prove proper operation prior to carrying passengers.
Due 17 March 2005
Resolved 22 February 2005
Resolution: MDE and other components performed all sat.
Lifesaving › Hand Flares
Issued 15 January 2002 Resolved
Six orange smoke flares expired. LEGACY COMPONENT DESC: Orange smoke flares
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 January 2002
Resolved 17 January 2002
Resolution: Flares replaced.
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 15 January 2002 Resolved
Relabel life jacket stowage lockers to properly reflect the amount stowed in each location.
Condition: Unknown
Due 21 January 2002
Resolved 17 January 2002
Resolution: Lockers relableled
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 15 January 2002 Resolved
Provide one additional child size lifejacket.
Condition: Unknown
Due 21 January 2002
Resolved 17 January 2002
Resolution: One additonal child size life jacket provided.
Documentation
Issued 23 January 2001 Resolved
Provide waste management plan onboard vessel.
Condition: Unknown
Due 23 January 2001
Resolved 23 January 2001
Fire Fighting
Issued 23 January 2001 Resolved
Provide 3-2.5 gallon fire buckets.
Condition: Unknown
Due 23 January 2001
Resolved 23 January 2001
Engineering
Issued 23 January 2001 Resolved
Provide operational test of vessel's propulsion engine.
Condition: Unknown
Due 23 January 2001
Resolved 23 January 2001
Navigation
Issued 23 January 2001 Resolved
Provide operational test of single side band radio fathometer and bilge pump.
Condition: Unknown
Due 23 January 2001
Resolved 23 January 2001
Construction/Loadline
Issued 23 January 2001 Resolved
Repair steering gear bilge high level alarm.
Condition: Unknown
Due 23 January 2001
Resolved 23 January 2001
Accommodation/Occupational Safety
Issued 23 January 2001 Resolved
Replace expired aspirin, eye wash and iodine applicators.
Condition: Unknown
Due 23 January 2001
Resolved 23 January 2001
Documentation
Issued 26 January 2000 Resolved
PROVIDE FCC RADIO CERTIFICATE. 47CFR13
Condition: Unknown
Due 26 January 2000
Resolved 26 January 2000
Lifesaving
Issued 26 January 2000 Resolved
INSTALL PLACARDS FOR THE STORAGE LOCATION OF ALL LIFE JACKETS. ENSURE CHILDSIZE LIFE JACKETS ARE STORED IN A SEPARATE LOCATION FROM THE ADULTS. 46CFR180.78
Condition: Unknown
Due 26 January 2000
Resolved 26 January 2000
Electrical
Issued 28 January 1999 Resolved
Remove dead end cable in bow compartment, or properly secure in junction box.
Condition: Unknown
Due 28 January 1999
Resolved 28 January 1999
Engineering
Issued 28 January 1999 Resolved
PROVE PROPER OPERATION OF THE BILGE, PROPULSION, NAVIGATION AND STEERING SYSTEMS.
Condition: Unknown
Due 28 January 1999
Resolved 28 January 1999
Construction/Loadline
Issued 28 January 1999 Resolved
Make proper repairs to the water saturated housing for the engine sea strainer.
Condition: Unknown
Due 28 January 1999
Resolved 28 January 1999
Engineering
Issued 28 January 1999 Resolved
Identify source of leaks in exhaust line at first seam aft of backflow loopin engine compartment and aft of forward bulkhead in aft fuel tank compartment
Condition: Unknown
Due 28 January 1999
Resolved 28 January 1999
Documentation
Issued 3 February 1998 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 24 February 1998
Resolved 24 February 1998
Lifesaving
Issued 3 February 1998 Resolved
PROVIDE LAUNCHING INSTRUCTION FOR INFL. L/R, TO BE POSTED IN PLAIN VIEW OF PASSENGERS & CREW.
Condition: Unknown
Due 24 February 1998
Resolved 24 February 1998
Accommodation/Occupational Safety
Issued 3 February 1998 Resolved
PROVIDE FIRST AID KIT, PER 46 CFR 184.710 (MEETING 46 CFR 160.041 OR EQUIV.)
Condition: Unknown
Due 24 February 1998
Resolved 24 February 1998
Navigation
Issued 3 February 1998 Resolved
PROVIDE CURRENT AND CORRECTED U.S. COAST PILOT AND NAVIGATIONAL CHARTS APPLICABLE TO AUTHORIZED ROUTE ON COI.
Condition: Unknown
Due 24 February 1998
Resolved 24 February 1998
Navigation
Issued 29 January 1997 Resolved
CONDUCT HYDRO TEST AND RECHARGE CO2 BOTTLE FOR SHIP'S HORN.
Condition: Unknown
Due 29 January 1997
Resolved 29 January 1997
Electrical
Issued 29 January 1997 Resolved
HARDWIRE THE SHORE POWER ELECTRICAL SYSTEM AND RECEPTACLE IN ACCORDANCE WITH GOOD MARINE PRACTICE.
Condition: Unknown
Due 29 January 1997
Resolved 29 January 1997
Construction/Loadline
Issued 29 January 1997 Resolved
PROVIDE WATERTIGHT COVER FOR 4-INCH DECK OPENING ON BOW.
Condition: Unknown
Due 29 January 1997
Resolved 29 January 1997
Lifesaving
Issued 2 February 1996 Resolved
Renew line on ring buoy due to wastage and fraying.
Condition: Unknown
Due 2 February 1996
Resolved 2 February 1996
Lifesaving
Issued 2 February 1996 Resolved
Replace cork PFD which was found to have a ripped shoulder seam.
Condition: Unknown
Due 2 February 1996
Resolved 2 February 1996
Fire Fighting
Issued 2 February 1996 Resolved
Extinguishers off vessel for servicing. Replace extinguishers (2 B-I, 3 B-II) prior to placing the vessel back in operation.
Condition: Unknown
Due 2 February 1996
Resolved 2 February 1996
Navigation
Issued 17 February 1995 Resolved
Prove proper operation of all electronic navigation equipment prior to carrying passengers for hire.
Condition: Unknown
Due 17 February 1995
Resolved 17 February 1995
Navigation
Issued 17 February 1995 Resolved
Repair/replace bow navigation running light prior to carrying passengers for hire.
Condition: Unknown
Due 17 February 1995
Resolved 17 February 1995
Construction/Loadline
Issued 17 February 1995 Resolved
Prove proper operation of bilge pump prior to carrying passengers for hire.
Condition: Unknown
Due 17 February 1995
Resolved 17 February 1995
Engineering
Issued 17 February 1995 Resolved
Provide proper flame impingement bowl for port side fuel filter prior to carrying passengers for hire.
Condition: Unknown
Due 17 February 1995
Resolved 17 February 1995
Documentation
Issued 17 February 1995 Resolved
Provide proof of FCC Operator's license prior to carrying passengers for hire.
Condition: Unknown
Due 17 February 1995
Resolved 17 February 1995
Electrical
Issued 17 February 1995 Resolved
Provide proper battery box cover prior to carrying passengers for hire.
Condition: Unknown
Due 17 February 1995
Resolved 17 February 1995
Construction/Loadline
Issued 17 February 1995 Resolved
Replace MSD through hull valve prior to carrying passengers for hire.
Condition: Unknown
Due 17 February 1995
Resolved 17 February 1995
Engineering
Issued 17 February 1995 Resolved
Prove proper operation of main engines prior to carrying passengers for hire.
Condition: Unknown
Due 17 February 1995
Resolved 17 February 1995
Construction/Loadline
Issued 19 February 1993 Resolved
CONDUCT SATISFACTORY TEST OF BILGE PUMPING SYSTEM.
Condition: Unknown
Due 3 March 1993
Resolved 3 March 1993
Engineering
Issued 19 February 1993 Resolved
CONDUCT SATISFACTORY OPERATIONAL TEST OF MAIN PROPULSION SYSTEM.
Condition: Unknown
Due 3 March 1993
Resolved 3 March 1993
Navigation
Issued 26 February 1992 Resolved
REPAIR ANCHOR LIGHT.
Condition: Unknown
Due 26 February 1992
Resolved 26 February 1992
Navigation
Issued 26 February 1992 Resolved
REPAIR HYDRAULIC LEAK IN STEERING SYSTEM LOCATED IN LAZARETTE.
Condition: Unknown
Due 26 February 1992
Resolved 26 February 1992
Engineering
Issued 26 February 1992 Resolved
REMOVE VALVE AND INSTALL A PIPE PLUG IN THE BOTTOM OF THE INBOARD FUEL FILTER.
Condition: Unknown
Due 26 February 1992
Resolved 26 February 1992
Navigation
Issued 26 February 1992 Resolved
REPAIR THE CROSS OVER VALVE FOR THE EMERGENCY STEERING.
Condition: Unknown
Due 26 February 1992
Resolved 26 February 1992
Lifesaving
Issued 26 February 1992 Resolved
REPAINT BUOYANT APPARATUS.
Condition: Unknown
Due 26 February 1992
Resolved 26 February 1992
Lifesaving
Issued 26 February 1992 Resolved
PROVIDE A PAINTER THAT IS RESISTANT TO ULTRAVIOLET LIGHT. SECURE TO THE_x001C_ BUOYANT APPARATUS AND ALSO SECURE TO THE VESSEL BY A FLOAT FREE LINK._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 26 February 1992
Resolved 26 February 1992
Documentation
Issued 19 February 1991 Resolved
SUBMIT OPERATIONAL TEST FORM.
Condition: Unknown
Due 19 February 1991
Resolved 19 February 1991
Engineering
Issued 19 February 1991 Resolved
SHOW PROOF THAT ENGINE FUEL HOSE IS OF AN APPROVED TYPE.
Condition: Unknown
Due 19 February 1991
Resolved 19 February 1991
Engineering
Issued 19 February 1991 Resolved
PROPERLY STENCIL REMOTE FUEL SHUT OFF ENSURING DIRECTION OF CLOSURE IS_x001C_ STENCILED.
Condition: Unknown
Due 19 February 1991
Resolved 19 February 1991
Lifesaving
Issued 19 February 1991 Resolved
PROPERLY STOW CHILD AND ADULT LIFE PRESERVERS ENSURING THAT CHILD LIFE_x001C_ PRESERVERS ARE STOWED SEPERATE FROM ADULT LIFE PRESERVIERS.
Condition: Unknown
Due 19 February 1991
Resolved 19 February 1991
Construction/Loadline
Issued 26 February 1990 Resolved
RESEAL MAIN DECK IN WAY OF BULWARKS AND AT LONGITUDINAL DECK SEAM STARBOARD SIDE AFT.
Condition: Unknown
Due 26 February 1990
Resolved 26 February 1990
Construction/Loadline
Issued 26 February 1990 Resolved
REPAIR AREAS OF ROT ON AFT PORTION OF CABIN AT DECK EDGE PORT & STARBOARD SIDES.
Condition: Unknown
Due 26 February 1990
Resolved 26 February 1990
Lifesaving
Issued 20 February 1989 Resolved
REPLACE CHAINS (2) WHICH ATTACH WATERLIGHTS (CARBIDE DYE) TO BUOYANT APPARATUS AND RING BUOY.
Condition: Unknown
Due 20 February 1989
Resolved 20 February 1989
Lifesaving
Issued 20 February 1989 Resolved
REPAIR DAMAGED CORNERS (2) TO BUOYANT APPARATUS AT AN APPROVED FACILITY.
Condition: Unknown
Due 20 February 1989
Resolved 20 February 1989
Fire Fighting
Issued 20 February 1989 Resolved
PROVIDE DOCUMENTATION OF A HYDROSTATIC TEST TO ONE (1) B-I AND ONE (1) B-II PORTABLE FIRE EXTINGUISHER.
Condition: Unknown
Due 20 February 1989
Resolved 20 February 1989
Navigation
Issued 20 February 1989 Resolved
PROVIDE A CURRENT COMMUNICATIONS ACT SAFETY RADIOTELEPHONY CERTIFICATE.
Condition: Unknown
Due 20 February 1989
Resolved 20 February 1989

Casualty record · 2

16 August 2020Routine · role: Involved in a Marine Casualty · activity 7060828
29 March 2022Routine · role: Involved in a Marine Casualty · activity 7425785
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record