MAURY USCG vessel records
← All vessels

SEA-LAND CHARGER

Built
1997
Last inspected
1 February 2016
Documentation
No record in the NVDC file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 10 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 1 February 2016
Operational controls None recorded without a removal date
Years with a record 1 calendar year (2016)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9143001
WDB9948
454858
Flag
SINGAPORE
Maury page id
psix-454858

Documentation record

Tonnage as PSIX records it59984 - Dead Weight, Ton
78735 - Displacement, Ton
49985 - Convention (Subpart B), Gross Ton
28968 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
The full record for this vessel

Behind this panel: 1 inspection, each with its date, unit and type; 4 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; no NVDC documentation record for this Official Number. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report

A report is not offered for this hull. Its Coast Guard record spans fewer than two calendar years. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 1

1 February 2016 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 5805118

Deficiency record · 4

Operations/Management › Casualty Reporting/Post-Casualty Actions › Report of Potential Vessel Casualty
Issued 1 February 2016 Resolved
9800- Whenever an accident occurs to a ship, which affects the safety of the ship or other equipment, the master or owner of the ship shall report at the earliest opportunity to the administration, the nominated surveyor or recognized organization responsible for issuing the relevant certificate, who shall cause investigation to be initiated to determin (Continued on form B) Solas (2014) I/II 17ac
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 February 2016
Resolution: Received survery report from class. Def cleared. Survey report is included in the document section.
Fire Fighting › Remote Fuel Shutoff › General
Issued 1 February 2016 Resolved
0750- Oil fuel pipes, which if damaged, would allow oil to escape from a storage, settling or daily service tank having a capacity of 500L and above situated above the bottom, shall be fitted with a cock or valve directly on the tank capable being closed from a safe position outside the space concerned in the event of a fire occurring in the space (Refer to form B) Solas (1997) II-2/4.2.2.3.4 17ac
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 February 2016
Resolution: Received survery report from class. Def cleared. Survey report is included in the document section.
Engineering › Steering Gear System › Linkage
Issued 1 February 2016 Resolved
1499- All steering gear compartments shall be of sound and reliable construction to the satisfaction of the Administration. No 1 steering gear motor has a cable disconnected for the heater and needs to be repaired. Solas (2004) 11-1/29.2.1 50ac
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 March 2016
Resolved 2 February 2016
Resolution: Received survery report from class. Def cleared. Survey report is included in the document section.
Electrical › Electric Supply System (service) › Cable
Issued 1 February 2016 Resolved
0950- Electrical installations shall be such that: The safety of pasenger, crew and ship from electrical hazards will be ensured. Solas (2004) 11-1/40.1.3 40ac
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 2 February 2016
Resolution: Received survery report from class. Def cleared. Survey report is included in the document section.