MAURY USCG vessel records Sign in
← All vessels

SHOOTING STAR

SHOOTING STAR is a 1967 passenger vessel (uninspected). The Coast Guard has recorded 33 inspections since 1981, most recently in November 2015, along with 33 deficiencies.

Records from 1981 to 2015. Most recent: inspection, 23 November 2015.

Built
1967
Last inspected
23 November 2015
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WX9037
Flag
UNITED STATES
—
Maury page id
psix-45494

Inspections, by type

…with no type recorded8
Years with a record 18 calendar years (1981–2015)
The 33 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 11 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it23 - Regulatory (Subpart C or D), Net Ton
30 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WX9037MMSI not assigned · expired · compulsorily equipped · granted 14 April 1994, cancelled 19 June 2004
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 33

23 November 2015 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5768972
6 June 2007 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2953509
3 June 2007 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2953449
1 April 1999 Type not recorded
No type recorded · Station Destin · USCG Heartland District (CGD-H) · Activity 1510027
8 March 1996 Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 884987
4 January 1996 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 878502
5 December 1995 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1412889
6 December 1994 COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1439578
20 September 1994 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1465181
15 December 1993 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 849394
30 November 1993 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 848220
26 March 1993 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1150703
20 January 1993 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 829705
15 December 1992 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 826493
11 December 1991 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1255234
4 December 1991 COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1262887
2 October 1991 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 942308
12 December 1990 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1225272
27 November 1990 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 905582
7 March 1990 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1218468
30 November 1989 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 920006
22 November 1988 Hull Examination · COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1218145
30 November 1987 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1003594
26 May 1987 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1315750
23 December 1986 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1004666
11 December 1985 COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1299974
19 November 1985 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 987564
5 November 1985 Credit Drydock
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1305728
13 June 1985 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1291697
11 May 1984 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 972598
16 December 1982 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 972131
17 November 1982 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 965892
6 May 1981 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1276967

Deficiency record · 33

Engineering
Issued 5 December 1995 Resolved
RENEW FUEL SUPPLY HOSE, LOCATED ON STARBOARD PROPULSION ENGINE BETWEEN FILTER AND PUMP. FUEL OIL HOSE TO MEET THE REQUIREMENTS OF 46 CFR 182.20- 40(a)&(b).
Condition: Unknown
Due 5 December 1995
Resolved 5 December 1995
Navigation
Issued 5 December 1995 Resolved
PROVE PROPER OPERATION OF THE VESSELS SOUND PRODUCING DEVICE (WHISTLE) IAW NAVIGATION RULES ANNEX III, RULE 1.
Condition: Unknown
Due 5 December 1995
Resolved 5 December 1995
Lifesaving
Issued 5 December 1995 Resolved
REPLACE OR COMPLETE REPAIRS TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR, OF THE 12 MAN BOUYANT APPARATUS.
Condition: Unknown
Due 5 December 1995
Resolved 5 December 1995
Engineering
Issued 5 December 1995 Resolved
INSTALL AND PROVE OPERATION OF PROPULSION ENGINE REMOTE SHUTDOWNS.
Condition: Unknown
Due 5 December 1995
Resolved 5 December 1995
Navigation
Issued 5 December 1995 Resolved
TIGHETN/REPACK PORT RUDDER TO REDUCE LEAKAGE AROUND RUDDER SHAFT.
Condition: Unknown
Due 5 December 1995
Resolved 5 December 1995
Documentation
Issued 5 December 1995 Resolved
RENEW POLLUTION PREVENTION PLACARD.
Condition: Unknown
Due 5 December 1995
Resolved 5 December 1995
Lifesaving
Issued 30 November 1993 Resolved
Repair loose corner attachments for laynard retainment around lifefloat.
Condition: Unknown
Due 30 November 1993
Resolved 30 November 1993
Engineering
Issued 30 November 1993 Resolved
REMOVE AND REPLACEPET COCK DRAIN FOR THE PORT ENGINE FUEL FILTER AND INSTALL A SOLID PLUG.
Condition: Unknown
Due 30 November 1993
Resolved 30 November 1993
Electrical
Issued 15 December 1992 Resolved
INSTALL PERMANENT WIRE SPLICES TO PORT AND STBD ALTERNATOR WIRING.
Condition: Unknown
Due 15 December 1992
Resolved 15 December 1992
Lifesaving
Issued 15 December 1992 Resolved
PROPERLY MARK FWD ACCOMMODATION EMERGENCY ESCAPE HATCH.
Condition: Unknown
Due 15 December 1992
Resolved 15 December 1992
Lifesaving
Issued 15 December 1992 Resolved
RENEW 100 FOOT SEA PAINTER TO BUOYANT APPARATUS._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 15 December 1992
Resolved 15 December 1992
Construction/Loadline
Issued 15 December 1992 Resolved
PROPERLY SUPPORT FIXED BILGE PIPING AND RENEW NONMETALLIC FLEXIBLE HOSE TO BELT DRIVEN BILGE PUMP LOCATED IN ENGINEROOM.
Condition: Unknown
Due 15 December 1992
Resolved 15 December 1992
Engineering
Issued 15 December 1992 Resolved
RENEW DETERIORATED HOSE CLAMPS TO MAIN DIESEL ENGINE EXHAUST PIPING.
Condition: Unknown
Due 15 December 1992
Resolved 15 December 1992
Navigation
Issued 15 December 1992 Resolved
TIGHTEN TILLER ARM ATTACHMENT TO PORT RUDDER.
Condition: Unknown
Due 15 December 1992
Resolved 15 December 1992
Accommodation/Occupational Safety
Issued 15 December 1992 Resolved
MECHANICALLY ATTACH ENGINEROOM VENT DUCTS TO ENSURE TIGHTNESS.
Condition: Unknown
Due 15 December 1992
Resolved 15 December 1992
Lifesaving
Issued 15 December 1992 Resolved
RENEW TWO CHIDREN LIFE PRESERVERS AND INSTALL RETROREFLECTIVE TAPE TO ONE ADULT LIFE PRESERVER._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 15 December 1992
Resolved 15 December 1992
Fire Fighting
Issued 15 December 1992 Resolved
SERVICE ALL PORTABLE FIRE EXTINGUISHERS._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 15 December 1992
Resolved 15 December 1992
Lifesaving
Issued 4 December 1991 Resolved
RENEW RETROREFLECTIVE TAPE TO 16 ADULT AND 4 CHILD LIFE PRESERVERS._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 7 February 1992
Resolved 7 February 1992
Lifesaving
Issued 4 December 1991 Resolved
INSTALL RETROREFLECTIVE TAPE ON BUOYANT APPARATUS._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 7 February 1992
Resolved 7 February 1992
Lifesaving
Issued 4 December 1991 Resolved
INSTALL WATERLIGHT TO BUOYANT APPARATUS._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 7 February 1992
Resolved 7 February 1992
Engineering
Issued 4 December 1991 Resolved
REPAIR LEAKS ON BOTH P/S ENGINE EXHAUST PIPING._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 7 February 1992
Resolved 7 February 1992
Engineering
Issued 4 December 1991 Resolved
REMOVE PET-COCK ON FUEL FILTER PORT SIDE SUPPLYING PORT MAIN DIESEL ENGINE.
Condition: Unknown
Due 7 February 1992
Resolved 7 February 1992
Engineering
Issued 4 December 1991 Resolved
RENEW HOSE TO STBD ENGINE EXHAUST COOLING SYSTEM._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 7 February 1992
Resolved 7 February 1992
Fire Fighting
Issued 4 December 1991 Resolved
SERVICE ALL PORTABLE FIRE EXTINGUISHERS AND PLACE TAG ON EACH RECORDING SERVICING._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 7 February 1992
Resolved 7 February 1992
Lifesaving
Issued 4 December 1991 Resolved
INSTALL SEPARATE LINE FOR WATERLIGHT ON RING BUOY._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 7 February 1992
Resolved 7 February 1992
Engineering
Issued 27 November 1990 Resolved
PROVIDE AND INSTALL PROPER MOUNTING SUPPORT FOR ENGINE DRIVEN BILGE PUMP
Condition: Unknown
Due 27 November 1990
Resolved 27 November 1990
Electrical
Issued 27 November 1990 Resolved
INSTALL COVERS TO BATTERY BOX INSTALLATIONS
Condition: Unknown
Due 27 November 1990
Resolved 27 November 1990
Navigation
Issued 27 November 1990 Resolved
TIGHTEN AND/OR REPACK AS NECCESSARY STBD. RUDDEER STUFFING TUBE.
Condition: Unknown
Due 27 November 1990
Resolved 27 November 1990
Deck/Cargo
Issued 23 December 1986 Resolved
PROVIDE AND PLACE ONBOARD A 45 LB OR LARGER ANCHOR.
Condition: Unknown
Due 23 December 1986
Resolved 23 December 1986
Fire Fighting
Issued 23 December 1986 Resolved
HAVE B-II CO2 FIRE EXTINGUISHER HYDROSTATICALLY TESTED OR REPLACE.
Condition: Unknown
Due 23 December 1986
Resolved 23 December 1986
Fire Fighting
Issued 23 December 1986 Resolved
RELOCATE B-I FIRE EXTINGUISHER FROM LOWER TO UPPER CONTROL SPACE.
Condition: Unknown
Due 23 December 1986
Resolved 23 December 1986
Electrical
Issued 23 December 1986 Resolved
PROVE OPERATION OF ALL FWD 120 LIGHTS.
Condition: Unknown
Due 23 December 1986
Resolved 23 December 1986
Accommodation/Occupational Safety
Issued 23 December 1986 Resolved
PROVIDE FLAME SCREEN FOR MSD VENT.
Condition: Unknown
Due 23 December 1986
Resolved 23 December 1986

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.