MAURY USCG vessel records Sign in
← All vessels

STARSHIP 2010

STARSHIP 2010 is a 1996 passenger vessel (inspected). The Coast Guard has recorded 42 inspections since 1997, most recently in January 2026, along with 35 deficiencies and 1 casualty investigation in 2006.

Records from 1997 to 2026. Most recent: inspection, 7 January 2026.

Built
1996
Last inspected
7 January 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

454941
Flag
UNITED STATES
—
Maury page id
psix-454941

Inspections, by type

…with no type recorded4
Years with a record 24 calendar years (1997–2026)
The 42 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)47.0 ft × 14.0 ft × 4.0 ft
Registered tonnagegross 17 / net 14
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderV I P MARINE INC · GRANTS PASS, OR, UNITED STATES · built 1996
Hull materialAluminum
PropulsionGasoline Engine
Hull shapeShip
Hull configurationMonohull
Hailing portLAKE HAVASU CITY, AZ
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 20 November 2025 · expires 30 November 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it17 - Simplified, Gross Ton
14 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 42

7 January 2026 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8302548
15 April 2025 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8104456
17 January 2024 COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7844368
9 January 2023 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7649128
9 February 2022 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7407647
31 August 2021 Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7275607
11 January 2021 Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7120681
14 November 2019 COI Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6848849
26 December 2018 Annual Inspection · DAPI Audit
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6602838
9 January 2018 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6323226
14 December 2016 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6045892
7 September 2016 Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5989878
5 January 2016 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5787941
9 January 2012 Annual Inspection · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 4221505
22 September 2011 Simplified Stability Test
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 4180346
7 September 2011 Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 4138501
14 July 2011 DAPI Audit
Administrative · USCG Southwest District (dp) · USCG Southwest District (CGD-SW) · Activity 4095232
10 January 2011 Annual Inspection · DAPI Audit
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3919678
3 February 2010 COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3670062
20 January 2009 Internal Structural Exam · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3389074
21 January 2008 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3126791
20 February 2006 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2589416
13 January 2006 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2560657
7 February 2005 Internal Structural Exam · COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2283755
20 January 2004 Annual Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 2089091
23 January 2003 Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1734708
23 April 2002 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1608508
20 March 2002 Internal Structural Exam
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1495393
22 January 2002 Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1480314
25 May 2001 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1066090
21 February 2001 Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1395631
2 March 2000 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 815975
9 February 2000 COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1430812
27 August 1999 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 731479
2 March 1999 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 80047
26 January 1999 Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1399060
26 January 1999 Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1410062
30 April 1998 Administrative
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 792271
1 April 1998 Administrative
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 787497
26 February 1998 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 787985
4 February 1998 Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1413319
24 March 1997 Initial Certification · Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1390542

Deficiency record · 35

01 - Certificates & Documentation › 013 - Documents › Signs, indications
Issued 14 November 2019 Resolved
Post EAP in crew spaces.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 14 November 2019
Resolved 14 November 2019
Resolution: Posted.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 14 November 2019 Resolved
Replace blower hoses as identified.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 14 November 2019
Resolved 14 November 2019
Resolution: Replaced hoses.
02 - Structural Conditions › N/A - No Subsystem › Openings to cargo area, doors, ... scuttles
Issued 26 December 2018 Resolved
Make available all compartments in cabin under seating for inspection. 2019 annual inspection did not inspect framing and bilge due to seating and carpet being bolted down.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 18 November 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 26 December 2018 Resolved
Remove old wiring that supplied 06 TV's back to breaker.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 18 November 2019
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 14 December 2016 Resolved
Renew expired D-cell batteries.
Due 14 January 2017
Resolved 7 February 2017
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 14 December 2016 Resolved
Replace non-buoyant line with buoyant line, at least 60Ft in length.
Due 14 January 2017
Resolved 7 February 2017
Communications › Alarms/Indicators › Fire Alarm
Issued 14 December 2016 Resolved
Repair or renew the generator compartment fume/gas detector. Correct prior to operating generator.
Action required: 705 - Other - as specified
Due 14 January 2017
Resolved 7 February 2017
Lifesaving › Hand Flares › Storage
Issued 10 January 2011 Resolved
Procure proper distress signal/flare container IAW 46CFR185.614
Action required: 705 - Other - as specified
Due 10 February 2011
Resolved 10 January 2011
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 10 January 2011 Resolved
Renew expired ammonia capsules in first aid kit.
Action required: 705 - Other - as specified
Due 10 February 2011
Resolved 10 January 2011
Communications › Alarms/Indicators › Fire Alarm
Issued 10 January 2011 Resolved
Engineroom fume/gas detection audible alarm is not sounding. IAW 46CFR182.480.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 January 2011
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 3 February 2010 Resolved
EAP program not in place, including training. A company Drug policy does not exist.
Action required: 705 - Other - as specified
Due 3 March 2010
Resolved 2 March 2010
Communications › Alarms/Indicators › General Alarm
Issued 3 February 2010 Resolved
Generator compartment gas/vapor detector is not operating and procedures for checking proper operation are not at operating station, nor is the operation manual onboard IAW 46 CFR 182.480. Correct deficiency prior to operating generator underway.
Action required: 705 - Other - as specified
Due 2 March 2010
Resolved 2 March 2010
Deck/Cargo › Vapor Control Systems › Vessel Vapor Overpressure/Vacuum Protection
Issued 7 February 2005 Resolved
Vapor detector/indicator found inop for generator space. Repair and demonstrate proper operation of vapor detector IAW 46 CFR 182.480 prior to using generator.
Action required: 705 - Other - as specified
Due 15 February 2005
Resolved 8 February 2005
Resolution: Sensor was replaced and proper operation demonstrated.
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 7 February 2005 Resolved
Lifejacket instructions found on board vessel did not match type of lifejacket found on vessel. Provide applicable lifejacket instructions for [name withheld] type on board.
Action required: 705 - Other - as specified
Due 15 February 2005
Resolved 16 February 2005
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 7 February 2005 Resolved
Retroreflective tape on several lifejackets found inadequate (torn or worn). Replace tape as needed.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 February 2005
Resolved 16 February 2005
Lifesaving › Lifebuoys
Issued 23 January 2003 Resolved
Renew retro-reflective tape on throwable life ring IAW 46 CFR 185.604
Due 1 March 2003
Resolved 12 February 2003
Engineering › Gasoline Engine (propulsion)
Issued 23 January 2003 Resolved
Extend ducts on the intake and exhaust fans in ER IAW 46 CFR 182.460 LEGACY COMPONENT DESC: Ventilation
Due 1 March 2003
Resolved 12 February 2003
Engineering › Gasoline Engine (propulsion)
Issued 23 January 2003 Resolved
Install placard to direct operation of blowers for four minutes prior to starting engines IAW ABYC H2. LEGACY COMPONENT DESC: Ventilation
Due 1 March 2003
Resolved 12 February 2003
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 23 January 2003 Resolved
Fax copy of Certificate of Documentation to MSO San Diego [phone withheld]
Due 3 February 2003
Resolved 3 February 2003
Lifesaving
Issued 21 February 2001 Resolved
Repair water light on life ring IAW 180.70
Condition: Unknown
Due 21 February 2001
Resolved 21 February 2001
Lifesaving
Issued 21 February 2001 Resolved
Mark vessel name on life ring.
Condition: Unknown
Due 21 February 2001
Resolved 21 February 2001
Fire Fighting
Issued 21 February 2001 Resolved
Replace discharged portable fire extinguisher.
Condition: Unknown
Due 21 February 2001
Resolved 27 February 2001
Fire Fighting
Issued 21 February 2001 Resolved
Service fixed fire extinguishing system & provide documentation.
Condition: Unknown
Due 22 February 2001
Resolved 27 February 2001
Unknown
Issued 21 February 2001 Resolved
Provide aspirin for first aid kit.
Condition: Unknown
Due 22 February 2001
Resolved 27 February 2001
Documentation
Issued 21 February 2001 Resolved
Provide MIS crew drug information for 1999.
Condition: Unknown
Due 21 February 2001
Resolved 27 February 2001
Lifesaving
Issued 21 February 2001 Resolved
Identify & repair generator leak fwd end.
Condition: Unknown
Due 21 February 2001
Resolved 27 February 2001
Fire Fighting
Issued 9 February 2000 Resolved
Demonstrate proper operation of fixed fire fighting system, blower shut down and override position.
Condition: Unknown
Due 3 March 2000
Resolved 3 March 2000
Documentation
Issued 4 February 1998 Resolved
Provide proper Drills, training, and lifesaving equipment logs.
Condition: Unknown
Due 23 February 1998
Resolved 23 February 1998
Construction/Loadline
Issued 4 February 1998 Resolved
Install bilge alarm in center compartment.
Condition: Unknown
Due 4 February 1998
Resolved 4 February 1998
Lifesaving
Issued 4 February 1998 Resolved
Replace expired medications in first aid kit.
Condition: Unknown
Due 23 February 1998
Resolved 23 February 1998
Construction/Loadline
Issued 4 February 1998 Resolved
Repair bilge alarm and demonstrate proper operations.
Condition: Unknown
Due 23 February 1998
Resolved 23 February 1998
Fire Fighting
Issued 4 February 1998 Resolved
Provide vent closures for fixed fire fighting spaces.
Condition: Unknown
Due 23 February 1998
Resolved 23 February 1998
Fire Fighting
Issued 4 February 1998 Resolved
Provide one 2.5 gallon fire bucket.
Condition: Unknown
Due 23 February 1998
Resolved 23 February 1998
Lifesaving
Issued 4 February 1998 Resolved
Put name of vessel on life ring.
Condition: Unknown
Due 23 February 1998
Resolved 23 February 1998
Accommodation/Occupational Safety
Issued 4 February 1998 Resolved
Provide waste management plan for vessel.
Condition: Unknown
Due 23 February 1998
Resolved 23 February 1998

Casualty record · 1

20 February 2006Routine · role: Involved in a Marine Casualty · activity 2589416
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record