This record may be incomplete: the most recent inspection recorded for this vessel was 24 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it855 - Regulatory (Subpart C or D), Gross Ton 855 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 1972 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
Inspection history · 37
3 October 2002Administrative Inspection
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1683816
14 June 1999Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 808312
13 May 1999Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1441503
8 June 1998Type not recorded
No type recorded · MSD QUAD CITIES · USCG Heartland District (CGD-H) · Activity 474440
6 May 1998Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1413358
12 March 1998Type not recorded
No type recorded · MSD QUAD CITIES · USCG Heartland District (CGD-H) · Activity 533403
15 February 1998Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 777973
Condition: Unknown
Due 13 June 1999
Resolved 3 October 2002
Resolution: cleared for administrative reasons
Construction/Loadline
Issued 13 May 1999Resolved
REPAIR 3 INCH VERTICAL CRACK AT DECK TRANVERSE SUPPORT IN AFT PART OF #3 PORT WING TANK.
Condition: Unknown
Due 13 June 1999
Resolved 3 October 2002
Resolution: cleared for administrative reasons
Construction/Loadline
Issued 13 May 1999Resolved
REPAIR/REPLACE GASKET ON ACCESS HATCH FOR BOW RAKE.
Condition: Unknown
Due 13 June 1999
Resolved 3 October 2002
Resolution: cleared for administrative reasons
Deck/Cargo
Issued 13 May 1999Resolved
REPLACE MISSING GASKET ON ULLAGE OPENING TO #3 CARGO TANK.
Condition: Unknown
Due 13 June 1999
Resolved 3 October 2002
Resolution: cleared for administrative reasons
Deck/Cargo
Issued 13 May 1999Resolved
CLEAN/REPLACE FLAME SCREEN IN PV VALVE FOR #2 CARGO TANK.
Condition: Unknown
Due 13 June 1999
Resolved 3 October 2002
Resolution: cleared for administrative reasons
Construction/Loadline
Issued 13 May 1999Resolved
REPAINT ALL DRAFT MARKINGS.
Condition: Unknown
Due 13 June 1999
Resolved 3 October 2002
Resolution: cleared for administrative reasons
Construction/Loadline
Issued 13 May 1999Resolved
REPAIR 12 INCH HORIZONTAL CRACKED WELD AT THE TURN OF THE PORT BOW KNUCKLE.
Condition: Unknown
Due 13 June 1999
Resolved 3 October 2002
Resolution: cleared for administrative reasons
Documentation
Issued 13 May 1999Resolved
PROVIDE CURRENT APPROVAL LETTER FOR VESSEL RESPONSE PLAN.
Condition: Unknown
Due 14 May 1999
Resolved 14 May 1999
Construction/Loadline
Issued 1 June 1995Resolved
MAKE AVAILABLE FOR INSPECTION PRIOR TO ANY CARGO OPERATION THE SATISFACTORYCOMPLETION OF ITEM NO. 01.
Condition: Unknown
Due 1 July 1995
Resolved 26 July 1995
Construction/Loadline
Issued 1 June 1995Resolved
AFTER SANDBLASTING OF VESSEL'S HULL AND PAINTING, REPLACE ALL HULL MARKINGSTO INCLUDE: DRAFT MARKS, NAME AND ALL SAFETY MARKINGS.
Condition: Unknown
Due 3 July 1995
Resolved 3 July 1995
Construction/Loadline
Issued 31 August 1993Resolved
DRY DOCK VESSEL AND EFFECT REPAIRS TO INTERNAL FRAMING AND BULKHEADS.
Condition: Unknown
Due 23 November 1993
Resolved 23 November 1993
Construction/Loadline
Issued 12 May 1992Resolved
RESTENCIL "DIESEL FUEL" AND "DANGER KEEP OUT" WHERE REQUIRED TO THE SATISFACTION OF THE COGNIZANT OCMI. TO BE COMPLIETED IN NO CASE LATER THANTHE ASSIGNED COMPLIANCE DATE.
Condition: Unknown
Due 12 May 1992
Resolved 12 May 1992
Deck/Cargo
Issued 12 May 1992Resolved
PROVE PROPER TEST OF CARGO PIPING SYSTEM TO THE SATISFACTION OF THE COGNIZANT OCMI. TO BE COMPLETED IN NO CASE LATER THAN THE ASSIGNED COMPLIANCE DATE.
Condition: Unknown
Due 12 May 1992
Resolved 12 May 1992
Construction/Loadline
Issued 22 June 1989Resolved
PAINT OUT INCORRECT VESSEL NAME AND HAILING PORT ON STERN.
Condition: Unknown
Due 22 June 1989
Resolved 22 June 1989
Accommodation/Occupational Safety
Issued 22 June 1989Resolved
MAKE PERMANENT REPAIRS TO CENTERLINE VENT ON BOW RAKE.
Condition: Unknown
Due 22 June 1989
Resolved 22 June 1989
Deck/Cargo
Issued 22 June 1989Resolved
CONDUCT ANNUAL TEST OF STEAM PIPING.
Condition: Unknown
Due 22 June 1989
Resolved 22 June 1989
Deck/Cargo
Issued 22 June 1989Resolved
CONDUCT OPERATIONAL TEST OF CARGO PUMP EMERGENCY SHUTDOWN.
Condition: Unknown
Due 22 June 1989
Resolved 22 June 1989
Construction/Loadline
Issued 22 June 1989Resolved
REMOVE PRODUCT RESIDUES FROM BOW RAKE, DETERMINE SOURCE OF LEAK AND MAKE PERMANENT REPAIRS.
Condition: Unknown
Due 22 June 1989
Resolved 22 June 1989
Documentation
Issued 22 June 1989Resolved
PLACE ORIGINAL CERTIFICATE OF INSPECTION ON BOARD VESSEL AND MAINTAIN IT THERE.
Condition: Unknown
Due 22 June 1989
Resolved 22 June 1989
Deck/Cargo
Issued 22 June 1988Resolved
PRIOR TO CONDUCTING ANY CARGO OPERATIONS PROVE SATISFACTORY OPERATION OF THE DIESEL CARGO PUMP ENGINE AND EMERGENCY SHUTDOWN TO THE SATISFACTION OF THE COGNIZANT OCMI.
Condition: Unknown
Due 22 June 1988
Resolved 22 June 1988
Construction/Loadline
Issued 22 June 1988Resolved
PRIOR TO CONDUCTING ANY CARGO OPERATIONS MAKE PERMANENT REPAIRS TO THE VENTS IN WAY OF BOW VOID TO THE SATISFACTION OF THE COGNIZANT OCMI.
Condition: Unknown
Due 22 June 1988
Resolved 22 June 1988
Deck/Cargo
Issued 22 June 1988Resolved
PRIOR TO CONDUCTING ANY CARGO OPERATIONS MAKE DECK SLOP TANK AVAILABLE FOR INTERNAL EXAMINATION TO THE SATISFACTION OF THE COGNIZANT OCMI.
Condition: Unknown
Due 22 June 1988
Resolved 22 June 1988
Deck/Cargo
Issued 22 June 1988Resolved
PRIOR TO CONDUCTING ANY CARGO OPERATIONS RENEW ALL GASKETS ON CARGO EXPANSION DOME MANWAYS AND ULLAGE OPENINGS TO THE SATISFACTION OF THE COGNIZANT OCMI.
Condition: Unknown
Due 22 June 1988
Resolved 22 June 1988
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.