MAURY USCG vessel records Sign in
← All vessels

M/V TACOMA

M/V TACOMA is a 1997 passenger vessel (inspected). The Coast Guard has recorded 211 inspections since 1997, most recently in March 2026, along with 112 deficiencies and 16 casualty investigations between 2002 and 2026.

Records from 1997 to 2026. Most recent: inspection, 27 March 2026.

Built
1997
Last inspected
27 March 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9133977 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WCX9244
455057
Flag
UNITED STATES
366772760
Maury page id
psix-455057

Inspections, by type

…with no type recorded61
Years with a record 29 calendar years (1997–2026)
The 211 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)440.0 ft × 89.8 ft × 25.8 ft
Registered tonnagegross 3,926 / net 2,066
ITC dimensions (L × B × D)440.0 ft × 89.8 ft × 25.8 ft
ITC tonnagegross 12,689 / net 5,426
BuilderTODD SHIPYARD · SEATTLE WA, UNITED STATES · built 1997
Hull materialSteel
PropulsionDiesel Electric
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portSEATTLE, WA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 9 October 2025 · expires 31 October 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it1393 - Dead Weight, Ton
12689 - Convention (Subpart B), Gross Ton
3926 - Regulatory (Subpart C or D), Gross Ton
5426 - Convention (Subpart B), Net Ton
2066 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WCX9244MMSI 366772760 · active · compulsorily equipped · granted 5 January 2018, expires 22 January 2028
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 211

27 March 2026 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8333175
19 March 2026 Deficiency Check · COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8303017
11 February 2026 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8309588
24 January 2026 Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8301171
17 January 2026 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8297987
29 October 2025 Re-Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8260707
3 October 2025 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8246124
27 March 2025 COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8100273
4 February 2025 Internal Structural Exam · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8078312
26 December 2024 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8062900
10 December 2024 Re-Inspection · MTSA Verification
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8045875
31 October 2024 Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8031612
15 October 2024 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8018855
4 October 2024 Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8014585
19 August 2024 Re-Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7987641
26 April 2024 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7901966
2 March 2024 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7873058
27 February 2024 Periodic Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7870912
26 February 2024 COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7870355
6 October 2023 Deficiency Check · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7804511
6 October 2023 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7813230
9 August 2023 Re-Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7767782
19 May 2023 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7701913
10 May 2023 COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7680332
16 February 2023 Internal Structural Exam · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7637404
31 January 2023 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7637429
11 January 2023 Re-Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7622016
21 November 2022 Re-Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7598024
19 August 2022 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7538174
22 July 2022 Deficiency Check · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7513845
6 July 2022 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7500892
31 May 2022 Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7465810
28 May 2022 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7468269
27 May 2022 Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7465593
18 April 2022 Administrative Inspection · COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7433527
3 January 2022 Re-Inspection · Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7375702
22 November 2021 Re-Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7355521
18 November 2021 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7353706
26 October 2021 Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7340406
16 October 2021 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7334885
7 July 2021 Re-Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7248723
19 April 2021 Re-Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7178556
8 April 2021 Administrative Inspection · COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7167645
9 February 2021 Re-Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7137929
15 December 2020 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7117086
29 September 2020 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7068232
21 September 2020 Damage Survey
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7063578
17 September 2020 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7061245
6 August 2020 Internal Structural Exam · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7026109
16 July 2020 COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7008197
22 January 2020 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6893980
23 December 2019 Re-Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6874755
22 October 2019 Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6839741
24 September 2019 Administrative Inspection · Periodic Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6817021
28 July 2019 Administrative Inspection · Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6766046
1 July 2019 Administrative Inspection · Re-Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6732388
6 May 2019 Construction Oversight
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6673805
26 March 2019 COI Inspection · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6640380
8 March 2019 MTSA/ISPS Verification · Administrative Inspection · Deficiency Check · Re-Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6639074
16 December 2018 Administrative Inspection · Security Breach
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6599187
4 December 2018 Damage Survey
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6592058
27 July 2018 MTSA Verification · Re-Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6492784
18 June 2018 Internal Structural Exam · Underwater Inspection in lieu of Drydock
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6445148
22 May 2018 Deficiency Check · Damage Survey · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6421593
3 April 2018 Re-Inspection · MTSA Verification
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6384582
2 April 2018 Security Breach, Potential · Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6385125
19 January 2018 MTSA Verification · COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6340656
9 December 2017 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6323033
29 November 2017 Re-Inspection · MTSA Verification
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6308946
15 September 2017 Re-Inspection · MTSA Verification
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6272802
24 April 2017 MTSA Verification · Re-Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6160994
18 April 2017 Security Breach, Potential
Type not classified · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6131628
3 April 2017 Security Breach, Potential
Type not classified · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6117587
26 February 2017 Security Breach, Potential
Type not classified · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6101163
21 February 2017 COI Inspection · MTSA Verification
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6091772
1 December 2016 MTSA Verification · Re-Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6049211
1 October 2016 Deficiency Check · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6014819
2 September 2016 Re-Inspection · MTSA Verification
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5990240
1 August 2016 Examination of Repairs
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5946264
25 May 2016 Re-Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5885922
18 February 2016 MTSA/ISPS Verification · COI Inspection · Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5816231
13 October 2015 Examination of Repairs · Re-Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5747743
2 October 2015 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5734397
2 October 2014 Internal Structural Exam · Underwater Inspection in lieu of Drydock
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4997842
23 July 2012 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4388883
11 July 2012 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4376649
7 July 2012 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4370809
4 June 2012 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4340836
4 May 2012 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4301911
6 February 2012 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4239373
17 January 2012 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4244985
4 January 2012 MTSA Verification · COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4218279
8 December 2011 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4222968
5 December 2011 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4201820
3 December 2011 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4202650
1 December 2011 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4200349
13 September 2011 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4144450
29 August 2011 MTSA Verification · Re-Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4132865
10 January 2011 COI Inspection · MTSA Verification
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3924011
19 December 2010 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3913512
24 September 2010 MTSA Verification · Re-Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3863100
23 December 2009 COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3654472
20 July 2009 Re-Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3540773
14 May 2009 Re-Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3475588
8 March 2009 MTSA Verification · Re-Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3649883
8 January 2009 COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3389815
20 October 2008 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3353656
9 October 2008 MTSA Verification · Re-Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3341685
19 August 2008 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3304029
19 August 2008 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3304729
2 July 2008 Re-Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3255034
2 April 2008 Periodic Inspection · MTSA Verification
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3176203
3 January 2008 COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3121131
21 May 2007 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2966234
20 April 2007 Re-Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2913653
19 April 2007 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2911269
12 February 2007 Damage Survey · Internal Structural Exam · Hull Examination · In-Service Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2832183
9 February 2007 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2869684
9 January 2007 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2860489
6 January 2007 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2852705
15 September 2006 MTSA Verification · Re-Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2779373
20 July 2006 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2719539
27 June 2006 Re-Inspection · MTSA Verification
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2693514
14 June 2006 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2681841
18 April 2006 MTSA Verification · Re-Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2627637
6 September 2005 MTSA Verification · Re-Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2486193
2 August 2005 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2479676
11 July 2005 MTSA Verification
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2423301
13 June 2005 MTSA Verification · Re-Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2419429
29 March 2005 MTSA Verification
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2333794
14 March 2005 Re-Inspection · MTSA Verification
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2352968
3 December 2004 COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2253031
3 December 2004 Internal Structural Exam · Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2255668
17 October 2004 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2230098
15 October 2004 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2221492
3 August 2004 MTSA Verification · Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2154601
8 March 2004 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2022211
15 January 2004 COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1988938
28 August 2003 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1894658
23 July 2003 Quarterly Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1855235
15 July 2003 Administrative Inspection
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1847018
26 June 2003 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1848021
12 June 2003 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1819034
20 May 2003 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1804977
27 March 2003 COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1762799
9 December 2002 Quarterly Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1718024
1 December 2002 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1760679
7 November 2002 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1704945
17 September 2002 Quarterly Examination · MARPOL Annex I Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1676880
25 July 2002 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1668449
24 July 2002 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1652543
18 July 2002 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1655829
14 June 2002 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1632243
26 May 2002 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1622160
7 May 2002 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1617715
18 April 2002 COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1606447
28 March 2002 COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1601760
6 February 2002 Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1484492
12 December 2001 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1362596
7 September 2001 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1425195
24 July 2001 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1360
22 July 2001 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 17408
6 July 2001 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 64343
26 June 2001 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1401507
5 May 2001 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 117315
16 April 2001 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 98819
15 March 2001 COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1408698
11 March 2001 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 85645
22 January 2001 Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 825134
3 January 2001 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1384637
3 October 2000 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1471027
6 July 2000 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1365851
16 June 2000 Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1403153
3 April 2000 COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1442982
21 January 2000 Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1048031
6 January 2000 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1457730
22 December 1999 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 212661
22 December 1999 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 813432
29 September 1999 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1413613
23 July 1999 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 99047
23 July 1999 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 141841
30 June 1999 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1386543
30 March 1999 COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1453577
16 March 1999 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1113282
22 February 1999 Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 795939
14 December 1998 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1375585
12 December 1998 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 110901
11 September 1998 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1404611
1 September 1998 Damage Survey
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1368842
17 July 1998 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 47385
15 July 1998 Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1129200
16 June 1998 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 15646
16 June 1998 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 106212
15 June 1998 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1444023
10 June 1998 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 174614
17 May 1998 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 35792
12 May 1998 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 44364
22 April 1998 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 142198
21 April 1998 Examination of Repairs
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1381218
10 April 1998 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 105022
10 April 1998 Examination of Repairs
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1386232
31 March 1998 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 172366
19 March 1998 COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1364642
8 March 1998 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 114526
27 January 1998 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 165720
20 January 1998 Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1112270
29 December 1997 Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 785265
19 December 1997 Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1116289
8 December 1997 Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 781394
8 December 1997 Re-Inspection · Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1383730
15 August 1997 Inclining Experiment · Hull Examination · COI Inspection · Deadweight Survey · Initial Construction-Excluding Oversight
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1119058

Deficiency record · 112

08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 26 March 2026 Resolved
It shall be the duty of the master to see that all watertight doors in subdivision bulkheads that may be opened at sea, and all mechanisms, remote controls, and indicators therewith, shall be periodically inspected at least once in each week that the vessel is navigated to be assured that they are in proper operating condition. Low Pressure alarm for WTD 3 is active in both pilot houses.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 April 2026
Resolved 27 May 2026
Resolution: No alarms observed in pilot house during def check
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 11 February 2026 Resolved
It shall be the duty of the master to see that all watertight doors in subdivision bulkheads that may be opened at sea, and all mechanisms, remote controls, and indicators connected therewith, shall be periodically inspected at least once in each week that the vessel is navigated to be assured that they are in proper operating condition. The WTD leading to the #1 end shaft alley has inoperable controls. Vessel to operate with the door in the closed position unless entry to the space is necessary. Vessel to enact repairs to the satisfaction of USCG Marine Inspector. 46 CFR 78.17-3
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 February 2026
Resolved 15 February 2026
Resolution: Recieved satisfactory report of motor overload and contactor replacement. Cleared verbally by [name withheld].
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 24 January 2026 Resolved
Electronic installations on vessels must ensure:(1) Maintenance of services necessary for safety under normal and emergency conditions.(2)Protection of passengers, crew, other persons, and the vessel from electrical hazards(3)Maintenance of system integrity through compliance with the applicable system requirements to which a plan review has been approved. Vessel self reported faulty automatic voltage regulator on #3 generator in #2 engine room.
Action required: 10 - Deficiency Rectified
Resolved 24 January 2026
Resolution: Replaced automatic voltage regulator; USCG verified sat operation of #3 gen.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 24 January 2026 Resolved
Electronic installations on vessels must ensure:(1) Maintenance of services necessary for safety under normal and emergency conditions.(2)Protection of passengers, crew, other persons, and the vessel from electrical hazards(3)Maintenance of system integrity through compliance with the applicable system requirements to which a plan review has been approved. Vessel self reported faulty automatic voltage regulator on #4 generator in #2 engine room.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 February 2026
Resolved 26 January 2026
Resolution: See Narrative.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 24 January 2026 Resolved
Electronic installations on vessels must ensure:(1) Maintenance of services necessary for safety under normal and emergency conditions.(2)Protection of passengers, crew, other persons, and the vessel from electrical hazards(3)Maintenance of system integrity through compliance with the applicable system requirements to which a plan review has been approved. Vessel self reported faulty #3 drive motor in the #2 engine room.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 February 2026
Resolved 26 January 2026
Resolution: See Narrative.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 26 December 2024 Resolved
TACOMA reported they have a leak coming from the deck scupper on the car deck #2 end STBD between frames 33 and 34. They found a small puddle on the deck below in the #2 end storeroom. They cannot identify exactly where the pinhole is, but it appears to be coming from the scupper that runs from the center tunnel to the wing tunnel at the curb. These have been problem areas for us.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 February 2025
Resolved 27 February 2025
Resolution: Approved perm repairs made to addresss the leak.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 10 December 2024 Resolved
Doors, other than those which are normally locked, such as from staterooms, fan rooms, lockers, etc., shall be of the self-closing type capable of closing against a 3 1/2 degree list, and such doors shall be numbered in accordance with subpart78.47-35 of this sub-chapter. MI observed fire screen door #38 failed to fully close and latch when released.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 December 2024
Resolved 28 February 2025
Resolution: Confirmed the correct FSD operation.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 15 October 2024 Resolved
Where pipes are carried through watertight or oiltight bulkheads, the integrity of the structure must be maintained. Stern tube seal self reported as leaking approx. 1 gal per minute into the bilge.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 November 2024
Resolved 15 October 2024
Resolution: Cause of leak was found to be loose ring seal bolt. Vessel crew tightened, filled system with oil, and conducted operational test prior to return to service.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 4 October 2024 Resolved
An inspection, either general or partial depending upon the circumstances, shall be made whenever any important repairs or alterations are undertaken. Vessel to repair damage to Texas deck at next dockside availability. Vessel crew to prohibit passengers from damaged deck area.
Action required: 705 - Other - as specified
Resolved 31 October 2024
Resolution: Corroded deck was cropped and renewed with 10"x10" insert. Concrete removed and to be replaced by steel ramp.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 19 August 2024 Resolved
Issued CG-835V for multiple ventilation closures found seized/ unable to close.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 September 2024
Resolved 7 November 2024
Resolution: Satisfactorily repaired.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 27 February 2024 Resolved
IAW ASTM F1197-19 (11.4) Power control systems shall close doors at an approximately uniform rate of closure, but in no case shall the closure time, from the time a door begins to move to the time it reaches the fully closed position, be less than 20 s or more than 40 s. Shaft alley door on the number one (1) end closed in 13 seconds.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 27 February 2024
Resolved 27 February 2024
Resolution: Control system was adjusted on the spot and now closes in 25 seconds, IAW ASTM F1197-19 (11.4)
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 19 May 2023 Resolved
Fire on the number 2 drive motor, alpha 1 cabinet.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 May 2023
Resolved 27 February 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 22 July 2022 Resolved
Stern tube is leaking oil due to a faulty stern tube seal. Replace seal prior to movement. 33 CFR 155.5021
Action required: 60 - Rectify deficiencies prior to movement
Resolved 5 August 2022
Resolution: Received email from Chief Engineer attesting to repairs of the leaking stern tube seal to the satisfaction of the Marine Inspector.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 18 April 2022 Resolved
Repair the NFU steering control system. 2A and 2B pumps surge/hunt in NFU mode from the pilothouse. 46 CFR 58.25-10
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 May 2022
Resolved 10 May 2023
Resolution: Previous inspector (Rous) attended at unknown date after 27JUN2022 and cleared deficiency.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 18 April 2022 Resolved
Prove the proper operation of the inport generator. The governor control system could not maintain 1800 RPM. Complete PSTP: IPG-1, 4, SPM, 1, 2 prior to using the inport generator. 46 CFR 62.25-15
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 May 2022
Resolved 10 May 2023
Resolution: Governor replaced by crew. Tested inport generator IAW approved PSTPs.
08 - Alarms › N/A - No Subsystem › Engineers' alarm
Issued 18 April 2022 Resolved
The visual indicator for the No.3 MDE did not indicate on a low lube oil alarm. Repair/provide a visual indicator. 46 CFR 62.25-25
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 May 2022
Resolved 27 May 2022
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 18 April 2022 Resolved
The CO2 system shall auto shutdown the power ventilation in the engineering paint locker. The supply fan remained online. 46 CFR 76.15-35
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 May 2022
Resolved 27 February 2024
Resolution: Auto Shut down in working order.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 18 April 2022 Resolved
Prove the proper operation of the No.1 pilothouse shaft RPM meter. The meter displayed 8-9 RPMs at 5 turns. 46 CFR 62.35-5
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 May 2022
Resolved 10 May 2023
Resolution: Previous inspector (Rous) attended at unknown date after issuance and cleared deficiency.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 26 October 2021 Resolved
Leak on saltwater flange on cooler piping in #1 engine room. Crew must maintain rounds to observe if leak rate increases past 1-2 drips/seconds. Vessel must replace piping to ensure permanent fix of flange.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 November 2021
Resolved 3 November 2021
Resolution: Replaced w/ permanent flange, system fully in tact.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 7 July 2021 Resolved
Fire doors 21 and 33 did not fully close. Show proper operation of fire doors.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 July 2021
Resolved 12 July 2021
Resolution: Vessel lowered cabin pressure and adjusted swing arms. Doors close properly. All sat.
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 8 April 2021 Resolved
Vessel must have fully functioning public address system for transmission of orders and information throughout vessel/ Must fix sound powered phone circuit to not automatically feed into 1MC.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 April 2021
Resolved 15 April 2021
Resolution: Cleared during testing at quarterly inspection.
04 - Emergency Systems › N/A - No Subsystem › Means of communication between safety centre and other control stations
Issued 8 April 2021 Resolved
Vessel must have fully functioning sound powered phone system for transmission of orders and information throughout vessel. Must fix sound powered phone circuit to not automatically feed into 1MC.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 April 2021
Resolved 15 April 2021
Resolution: Cleared during testing at quarterly inspection.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 8 April 2021 Resolved
All fire screen doors must be capable of release from control station and from a position at the door. Ensure 02 galley doors and FSD 09 and 12 are capable of this function.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 April 2021
Resolved 15 April 2021
Resolution: Cleared during testing at quarterly inspection.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 8 April 2021 Resolved
Provide and install required placards to indicate ring buoys on both No. 1 and No. 2 ends.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 May 2021
Resolved 15 April 2021
Resolution: Cleared during quarterly inspection.
07 - Fire Safety › N/A - No Subsystem › Fire control plan
Issued 8 April 2021 Resolved
Provide updated fire control plan without Fire Foam Cart accomodation.
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 9 August 2023
Resolution: "Walked" approved FCP Rev. D and all sat.
01 - Certificates & Documentation › 012 - Crew Certificates › Training and qualification MLC - Personnel safety training
Issued 8 April 2021 Resolved
Hazardous Material Training record must reflect training documentation for new employees within 90 days and recurring training once every 3 years.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 May 2021
Resolved 15 April 2021
Resolution: Cleared during quarterly inspection.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 8 April 2021 Resolved
Passenger accomodation spaces must be made ready for caqrriage of passengwers under safety general provisions.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 April 2021
Resolved 15 April 2021
Resolution: Cleared during quarterly inspection.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 29 September 2020 Resolved
JHOC rcvd call from WSF Opcen reporting the #2 end whistle is stuck open and inoperable.
Action required: 10 - Deficiency Rectified
Due 29 September 2020
Resolved 29 September 2020
Resolution: Whistle on #2 end repaired and working as designed.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 16 July 2020 Resolved
Make the vessel's fuel oil tanks ready for inspection by the vessels next drydock.
Action required: 10 - Deficiency Rectified
Resolved 8 April 2021
Resolution: Vessel provided diagram for hydraulic steering in both pilot house and emergency steering.
08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 16 July 2020 Resolved
Implement WSF's periodic safety test procedure (PSTP) corrective action plan as indicated on the SIP submittal dated JUL2020 within 90 days.
Action required: 705 - Other - as specified
Due 30 October 2020
Resolved 3 January 2022
Resolution: Insuficient detail in the deficiency or in the originating activity to identify the issue to be rectifed. Cleared administratively at direction of the CDV.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 16 July 2020 Resolved
Doors installed in class A fire boundaries, except those which are normally locked shall be of a self-closing type. Remove all hold-back devices and prove doors are self-closing.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 August 2020
Resolved 5 August 2020
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 16 July 2020 Resolved
Provide operating instructions with a block diagram of the steering gear control system and power units permanently displayed on the bridge and steering room.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 August 2020
Resolved 3 January 2022
Resolution: Diagrams posted.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Ventilators, air pipes, casings
Issued 16 July 2020 Resolved
Replace the painted and deteriorated No.1 end, P/S void space vent gaskets.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 August 2020
Resolved 5 August 2020
08 - Alarms › N/A - No Subsystem › General alarm
Issued 16 July 2020 Resolved
Mark general alarm bells throughout the vessel.
Action required: 10 - Deficiency Rectified
Resolved 30 July 2020
08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 16 July 2020 Resolved
Complete outstanding PSTP items not performed.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 August 2020
Resolved 3 January 2022
Resolution: Item self reported during COVID SIP. Insufficient detail in deficiency as well as originating activity to identify areas for correction. Administratively cleared deficiency as directed by CDV.
08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 16 July 2020 Resolved
Prove the proper operation of the harbor generator's L/O shutdown. The manufacturer's manual specifies min L/O of 15 PSI. The generator shutdown at 4 PSI.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 August 2020
Resolved 3 January 2022
Resolution: Verified the lube oil shut down functioned at the last annual exam. Administratively cleared deficiency as directed by the CDV.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 16 July 2020 Resolved
Provide an updated CO2 service report. The service report provided was missing the annual cylinder weights.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 August 2020
Resolved 5 August 2020
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 22 January 2020 Resolved
Reference CG-ENG-4 letter dated 11/15/2020 (attached)Case-by-Case approval of the Elkhart 241-95 Inline Foam Eductor. The use of this eductor is contingent upon using an appropriate nozzle that provides enough water and pressure in accordance with the manufacturers requirements to appropriately discharge the foam. The operating and maintenance instructions (attached) state that the "Elkhart eductors are calibrated to operate at 200 psig inlet pressure... The eductors can educt foam concentrate at inlet pressures as low as 100 psig when used with a recommended constant flow nozzle but the foam concentration will be richer". Provide objective evidence that the Elkhart 241-95 Inline Foam Eductor is able to discharge firefighting agent with the correct mixing rate of foam concentrate according to the guidelines from the foam manufacturer for the particular foam concentrate carried onboard. This must be completed prior to replacing the existing foam carts.
Action required: 705 - Other - as specified
Resolved 26 February 2020
Resolution: Verified new equipment performance from mfg cutsheet.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 28 July 2019 Resolved
#1 drive motor over-current relay light went off. Determine cause or switch out faulty relay.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 29 July 2019
Resolved 29 July 2019
Resolution: Relay replaced.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 26 March 2019 Resolved
In ventilation systems, fire dampers or other suitable means shall be provided for shutting off the passage of air in the event of a fire. The following fire dampers are non-operational: Fan room #2, sundeck lounge, #1 end, manual pull. Fan room #3 above panel intake handler, 5-5-9-1, manual pull. Fan room #3, passenger deck, #2 end starboard, manual pull. Fire damper label 5-09-2(1) on ceiling above door to men's head, no damper behind ceiling. Fire damper E1-19-1 in stairwell to engine room is stuck in the open position. Vessel has 7 days (5Apr19) to correct deficiencies.
Action required: 705 - Other - as specified
Due 5 April 2019
Resolved 1 April 2019
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 26 March 2019 Resolved
Foam agent, its container, and all control valves for the operation of the system shall be of an approved type. The AFFF concentrate in the ready tanks located on the upper car deck needs to be laboratory tested to prove effectiveness, and manufactures specifications needs to be provided on the spare containers to prove effectiveness. Additionally, functional testing and crew proficiency with equipment is required.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 April 2019
Resolved 26 February 2020
Resolution: See activity #6893980 for new equipment replacement.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 26 March 2019 Resolved
Each life-saving appliance must be inspected monthly using the checklists required under 46 CFR 199.190 (b)(1)(i) to make sure the appliance and the equipment are complete and in good working order. A report of the inspection, including a statement as to the condition of the equipment, must be recorded in the vessel's official logbook. Maintenance records for the vessel lifesaving equipment were not available because the records are being maintained with the watch-specific crew documents. Maintenance logs must be kept on board the vessel in the official logbook.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 April 2019
Resolved 11 April 2019
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 26 March 2019 Resolved
ll doors, except those that are kept normally closed, shall be of a type which are capable of release from the control station and from a postion at the door. Fire screen door (FSD), #1 end, upper car deck port side does not close and requires labelling. FSD 10 does not fully close. FSD 25 does not latch shut. Provide identification label for FSD, #1 end, upper car deck port side. All items were corrected on the spot and do not require further action, excluding the label for the referenced FSD.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 April 2019
Resolved 28 March 2019
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 26 March 2019 Resolved
Each section of fire hose must be lined commercial fire hose that conforms to UL 19. Fire station 43 hose was punctured and in unsatisfactory condition. The hose was condemned and replaced with a new hose. No action required.
Action required: 10 - Deficiency Rectified
Due 11 April 2019
Resolved 28 March 2019
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 26 March 2019 Resolved
It shall be the duty of the master to see that all watertight doors in subdivision bulkheads that may be opened at sea, and all mechanisms, remote controls, and indicators connected therewith, shall be periodically inspected at least once in each week that the vessel is navigated to be assured that they are in proper operating condition. Watertight door #1 did not shut from the pilot house panel because of a tripped breaker. Breaker was re-set and door was retested.
Action required: 10 - Deficiency Rectified
Due 11 April 2019
Resolved 28 March 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 8 March 2019 Resolved
Vessel auxiliary boilers past inspection due date. Tag out both boilers and may not use until required hydro test and inspection complete to USCG satisfaction.
Action required: 705 - Other - as specified
Resolved 11 March 2019
Resolution: Boilers inspections complete.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 8 March 2019 Resolved
Fire screen door #34 failed to self-close. Door self-closing device was repaired on spot.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 8 March 2019
Resolution: Repaired on spot by ship's crew.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 8 March 2019 Resolved
Child life jackets were stored with adult jackets intermingled. Adult life jackets properly re-stored by crew.
Action required: 10 - Deficiency Rectified
Resolved 8 March 2019
Resolution: Proper stowage effected by crew.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 4 December 2018 Resolved
Lock-out CP223, breaker No. 5 "Galley food prep area ltg". The breaker shall remain to be locked until the circuit wiring integrity (from panel breaker to outlet box) can be established via 500 volt megger test or above. Conduct fire and smoke rounds in the affected space at least every 15 minutes for the first 4 hours of operation. Thereafter, if no indications (smell or visual) are noted the additional rounds may be discontinued.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 December 2018
Resolved 18 December 2018
Lifesaving › Inflatable Buoyant Apparatus › Servicing
Issued 19 January 2018 Resolved
Service all (8) IBA due to expire in Jan 2018. Vessel granted extension by [name withheld] 46CFR199.190(g)(I)(ii)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 June 2018
Resolved 22 June 2018
Resolution: All IBAs were serviced and now expire Mar 2019.
Electrical › Electrical Distribution System (service) › Switchboard
Issued 19 January 2018 Resolved
Found Main Propulsion switchboard cabinets in both engine rooms are not fitted with dripshield as required. Repair proposal must include engineering calcuations ensuring that the explosion lelif characteristics of the cabinet, designed by the original manufactuer, are maintained.
Condition: Design Flaw
Due 18 March 2018
Resolved 10 July 2019
Resolution: Dripshield installed
Engineering › Steam Boiler (auxiliary/waste heat) › Automation Equipment
Issued 19 January 2018 Resolved
Prove proper oepration of #1 Boilwe and complete PSTP to the satisfaction of the attending marine inspector.
Condition: Improper/Lack of Maintenance
Due 18 March 2018
Resolved 6 January 2022
Resolution: Boilers were tested at each annual inspection since this was issued. Administratively clearing this outstanding deficiency.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 1 October 2016 Resolved
Vessel is restricted from operating from sunset to sunrise and during restricted visibility until proper operation of navigation lights.
Due 3 October 2016
Resolved 3 October 2016
Resolution: Electricians replaced two diodes on the #1 side along with a fuse, Nav light back to fully operational.
Communications › Internal Communications System › Engine Order Telegraph System
Issued 18 February 2016 Resolved
Engine order telegraph visual indicator on #1 end pilot house not functioning. 46 CFR 113.35-5(e)(1)
Action required: 705 - Other - as specified
Due 19 March 2016
Resolved 18 February 2016
Resolution: Alarm functioning.
Engineering › Engine Controls (Electric/Electronic) › Circuit Board
Issued 18 February 2016 Resolved
Loss of normal power alarm for remote propulsion control sounds only an audible. Table 62.35-50 via 46 CFR 62.35-1(a)
Action required: 705 - Other - as specified
Due 19 March 2016
Resolved 19 February 2016
Resolution: Loose connection found and corrected.
Engineering › Steam Boiler (auxiliary/waste heat) › Nozzle, Safety Valve
Issued 18 February 2016 Resolved
Both boiler safety relief valves set above MAWP. Provide valves set at 3 PSI. 46 CFR 53.01-10(b)(2)
Action required: 705 - Other - as specified
Due 19 April 2016
Resolved 4 August 2016
Resolution: Replace with new.
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 18 February 2016 Resolved
Inspection of required lifejackets found the total count 60 lifejackets short of the total required by COI. Provide 60 properly marked and stowed lifejackets. 46 CFR 71.25-15
Action required: 705 - Other - as specified
Due 18 February 2016
Resolved 18 February 2016
Resolution: 60 additional lifejackets brought on board and properly marked with vessel name.
Communications › Alarms/Indicators › General Alarm
Issued 18 February 2016 Resolved
Two general alarm bells not functioning #2 end, port side, on the Texas deck and #1 end upper car deck. Repair or replace. 46 CFR 113.25-1
Action required: 705 - Other - as specified
Due 4 March 2016
Resolved 19 February 2016
Resolution: Alarms operate properly.
Fire Fighting › Miscellaneous Items › A Class Division Penetrations
Issued 13 October 2015 Resolved
Repair door lock for the Emergency Gererator room. Crew unable to gain access to the space.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 October 2015
Resolved 13 October 2015
Resolution: The correct locking mechanism was installed.
Fire Fighting › Miscellaneous Items › A Class Division Penetrations
Issued 13 October 2015 Resolved
Repair fire screen doors 14 and 28 so that they close.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 October 2015
Resolved 13 October 2015
Resolution: Doors have been repaired.
Fire Fighting › Fire Main › Valves
Issued 5 January 2012 Resolved
#4 Fire main valve for car deck not closing all the way.
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 January 2012
Resolved 6 January 2012
Resolution: Replaced valve with a new one. Test Sat.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Tanks
Issued 5 January 2012 Resolved
30 second delay bottle for #1 Engine room operated at 25 seconds. Replace and test.
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 January 2012
Resolved 5 January 2012
Resolution: Replaced bottle with new one. Test sat.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Tanks
Issued 5 January 2012 Resolved
30 second delay bottle for Emergency Generator room operated at 25 seconds. Replace and test.
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 January 2012
Resolved 5 January 2012
Resolution: Replaced bottle with new one. Test sat.
Fire Fighting › Fire Hydrants › Condition
Issued 5 January 2012 Resolved
Fire stations a. #24 hose container glass broken b. #33 valve stem leak c. #40 valve stem leak d. #42 Y-valve needs replacement e. #44 vale loose
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 January 2012
Communications › Alarms/Indicators › General Alarm
Issued 5 January 2012 Resolved
General Alarms inoperable; a. Passenger accommodation midship port b. Crew lounge c. Upper car deck stbd aft d. Stbd fwd staircase passenger accomodation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 January 2012
Resolution: Observed the proper operation of all general alarms
Fire Fighting › Fire Hoses › Connections
Issued 13 January 2011 Resolved
Hose leaking from connection and valve packing. Fix leaks.
Action required: 705 - Other - as specified
Due 13 February 2011
Resolved 13 January 2011
Resolution: Hose and valve operating properly
Communications › Alarms/Indicators › General Alarm
Issued 13 January 2011 Resolved
4 general alarm bells on the car deck are not making audible sounds.
Action required: 705 - Other - as specified
Due 13 February 2011
Resolved 13 January 2011
Resolution: General alarm bells operating properly.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 13 January 2011 Resolved
7 liferings missing retroreflective tape
Action required: 705 - Other - as specified
Due 13 February 2011
Resolved 13 January 2011
Resolution: Properly replaced retroreflective on required liferings
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 13 January 2011 Resolved
Lifebuoy light not operating properly.
Action required: 705 - Other - as specified
Due 13 February 2011
Resolved 13 January 2011
Resolution: Replaced batteries and bulb. All satisfactory.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 13 January 2011 Resolved
#2 pilot house upper range light is burnt out.
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 February 2011
Resolved 13 January 2011
Resolution: Replaced bulb in range light. All satisfactory.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 13 January 2011 Resolved
#1 end navigation light panel is not alarming for the stbd running light.
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 February 2011
Resolved 14 February 2011
Resolution: Pulled navigation panel and replaced lose wires.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 13 January 2011 Resolved
Emergency light on upper passenger deck was burnt out
Action required: 705 - Other - as specified
Due 13 February 2011
Resolved 13 January 2011
Resolution: Replaced bulb on emergency light, all satisfactory
Stability › Watertight Integrity › General
Issued 13 January 2011 Resolved
The #1 Water Tight Door, leading to shaft alley, alarm was not operating properly.
Condition: Improper/Lack of Maintenance
Due 14 January 2011
Resolved 14 January 2011
Resolution: Alarm was overhauled and is now operating properly.
Fire Fighting › Ventilation Systems › Ducts
Issued 13 January 2011 Resolved
Fire Dampener S2-01-2(2) did not close all the way due to the handle being bent.
Condition: Improper/Lack of Maintenance
Due 13 January 2011
Resolved 13 January 2011
Resolution: The handle was straightened out and dampener is operating properly.
Fire Fighting › Fire Hoses › Condition
Issued 8 January 2009 Resolved
Renew fire hose at sta #42. Hose failed inspection during operational test. 46 CFR 25-20 (a) (4).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 January 2009
Resolved 8 January 2009
Resolution: Renewed hose, tested sat.
Fire Fighting › Fire Hydrants › Condition
Issued 8 January 2009 Resolved
Repair leaks at fire stations # 23, 38, 40, and 41. Hydrant shutoff valves leak at valve stems when system is charged. 46 CFR 76.10-15 (a).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 January 2009
Resolved 8 January 2009
Resolution: Adjusted and tested sat.
Engineering › Steam Boiler (auxiliary/waste heat) › Automation Equipment
Issued 8 January 2009 Resolved
Low water cutout float mechanism did not allow proper operation. 46 CFR 63.15-1.
Action required: 705 - Other - as specified
Due 8 January 2009
Resolved 8 January 2009
Resolution: Engineers troubleshot and found cause to be a stuck vacuum breaker on piping above float valve assembly. Vacuum breaker was cleaned/exercised. Tested sat.
Documentation › Markings/Placards › Warning Signs
Issued 8 January 2009 Resolved
Missing CO2 fixed fire-fighting system warning placard on emergency generator space entrance. 46 CFR 78.47-7.
Action required: 705 - Other - as specified
Due 8 January 2009
Resolved 8 January 2009
Resolution: Procured and installed new placard.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 3 January 2008 Resolved
Replace lights on #1 end starboard side ringbuoy and amidships port ringbuoy.
Due 3 January 2008
Resolved 3 January 2008
Electrical › Lighting (emergency) › Lighting Fixture
Issued 3 January 2008 Resolved
Replace emergency light on texas deck.
Due 3 January 2008
Resolved 3 January 2008
Documentation › Manifests/Lists › Muster List/Emergency Instructions
Issued 3 January 2008 Resolved
Renew #2 end starboard side muster list on car deck.
Due 3 January 2008
Resolved 3 January 2008
Accommodation/Occupational Safety › Medical/First Aid › Hospital Space
Issued 3 January 2008 Resolved
Replace eye wash liquid in galley.
Due 3 January 2008
Resolved 3 January 2008
Fire Fighting › Fire Hoses › Connections
Issued 3 January 2008 Resolved
Replace fire hose connection.
Due 3 January 2008
Resolved 3 January 2008
Fire Fighting › Firemans Outfit › Axe
Issued 3 January 2008 Resolved
Fire axe on #1 end pilot house needs to be labeled with vessel name.
Due 3 January 2008
Resolved 3 January 2008
Fire Fighting › Fire Main › Material
Issued 3 January 2008 Resolved
Repair leak in wasted piping, zone 1 sprinkler system.
Due 4 January 2008
Resolved 4 January 2008
Resolution: Welded and tested sat.
Accommodation/Occupational Safety › Ventilation › General
Issued 3 January 2008 Resolved
Prove proper operation of fire dampener, intake to import generator space.
Condition: Improper/Lack of Maintenance
Due 4 January 2008
Resolved 4 January 2008
Resolution: Tested sat.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Piping
Issued 3 January 2008 Resolved
Repair leaking piping flange, CO2 room.
Due 4 January 2008
Resolved 4 January 2008
Resolution: Tightened flange, test sat.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 20 April 2007 Resolved
life buoy light inoperative.
Condition: Unknown
Action required: 705 - Other - as specified
Due 20 April 2007
Resolved 20 April 2007
Resolution: replaced life buoy light.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 15 September 2006 Resolved
Complete satisfactory man overboard rescue drill.
Due 15 September 2006
Resolved 15 September 2006
Lifesaving › Lifebuoys › Serviceable
Issued 20 July 2006 Resolved
Replace port side passenger deck fwd lifebuoy due to servicability.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 July 2006
Resolved 20 July 2006
Resolution: Replaced lifebuoy.
Fire Fighting › Structural - Horizontal Zones › General
Issued 17 April 2006 Resolved
Fire Screen Door #10 does not close properly.
Due 17 April 2006
Resolved 17 April 2006
Resolution: Door hinge adjusted and door closes properly upon release.
Accommodation/Occupational Safety › Medical/First Aid
Issued 15 January 2004 Resolved
Renew expired items in first aid kit in EOS. LEGACY COMPONENT DESC: Medicine Chest
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 February 2004
Resolved 20 January 2004
Accommodation/Occupational Safety › Medical/First Aid
Issued 15 January 2004 Resolved
Hydro test oxygen bottle from medical kit in EOS. LEGACY COMPONENT DESC: Medicine Chest
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 February 2004
Resolved 20 January 2004
Resolution: New bottle placed on board and expired bottle removed.
Engineering
Issued 21 April 1998 Resolved
THE HEAT RECOVERY SYSTEM PUMPS ARE TO BE RUN IN THE BYPASS MODE UNTIL IT ISSATISFACTORY DEMONSTRATED THAT THE HARMONICS PRODUCED IN TH AFC MODE DO NOTEFFECT ANY ALARM/MONITORING OR CONTROL SYSTEM.
Condition: Unknown
Due 21 April 1998
Resolved 21 April 1998
Electrical
Issued 10 April 1998 Resolved
PROVE PROPER OPERATION OF PROPULSION SYSTEM TO INCLUDE BUT NOT LIMITED TO THE FOLLOWING:_x001C_ A) ENCODERS FOR ALL 4 PROPULSION MOTOR CONTROLS._x001C_ B) MOTOR AND GENERATOR CIRCUIT BREAKER COORDINATION._x001C_
Condition: Unknown
Due 17 April 1998
Resolved 21 April 1998
Fire Fighting
Issued 8 December 1997 Resolved
Demonstrate remote operation for fire screen door # 4
Condition: Unknown
Due 11 December 1997
Resolved 9 December 1997
Construction/Loadline
Issued 8 December 1997 Resolved
LOCATE AND STORE SLIDING WATERTIGHT DOOR HANDLES FOR THE #3 SYSTEM ON THE CAR DECK FOR IMMEDIATE ACCESS AND USE IN CASE OF EMERGENCY.
Condition: Unknown
Due 8 December 1997
Resolved 8 December 1997
Fire Fighting
Issued 8 December 1997 Resolved
PROVIDE A MEANS TO BREAK OPEN THE PORTABLE FIRE EXTINGUISHER CASINGS ON SITE IN CASE OF EMERGENCY.
Condition: Unknown
Due 8 December 1997
Resolved 8 December 1997
Fire Fighting
Issued 8 December 1997 Resolved
INSTALL KEYBOX OR REMOVE LOCKS ON FIRE FIGHTING AND LIFESAVING EQUIPMENT LOCKERS. (IE. FOAM STORAGE SPACES ON CAR DECK, SHOOTS FOR LIFE RAFTS, AND LIFE PRESERVER LOCKERS ON CAR DECK.)
Condition: Unknown
Due 8 December 1997
Resolved 8 December 1997
Lifesaving
Issued 8 December 1997 Resolved
Demonstrate proper operation of general alarm from #1 end Pilot House.
Condition: Unknown
Due 8 December 1997
Resolved 9 December 1997
Lifesaving
Issued 8 December 1997 Resolved
Repair cover to emergency stop switch, #1 end Pilot House.
Condition: Unknown
Due 11 December 1997
Resolved 9 December 1997
Lifesaving
Issued 8 December 1997 Resolved
PROVIDE FAIL SAFE SYSTEM METHOD ON RESCUE BOAT RECOVERY SHOULD HYDRAULICS FAIL. (UNABLE TO SWING IN DAVIT AND RESCUE BOAT MANUALLY.)
Condition: Unknown
Due 8 December 1997
Resolved 8 December 1997
Electrical
Issued 8 December 1997 Resolved
Demonstrate proper operation of overspeed trip on emergency generator.
Condition: Unknown
Due 8 December 1997
Resolved 9 December 1997
Construction/Loadline
Issued 15 August 1997 Resolved
PRIOR TO THE CARRIAGE OF PASSENGERS INSTALL ASME "U" STAMP ACCUMULATORS ON ALL IMS, INC. WATERTIGHT DOORS.
Condition: Unknown
Due 18 September 1997
Resolved 18 September 1997
Electrical
Issued 15 August 1997 Resolved
INSTALL EXIT SIGNS THAT MEET 46CFR112.15-1(d).
Condition: Unknown
Due 17 November 1997
Resolved 17 November 1997
Fire Fighting
Issued 15 August 1997 Resolved
SHOW MARINE SAFETY CENTER APPROVAL OF SFP DWG. NO. 91-472-600-05, SHEETS_x001C_ 1 THROUGH 7.
Condition: Unknown
Due 17 November 1997
Resolved 17 November 1997
Engineering
Issued 15 August 1997 Resolved
SUBMIT FOR APPROVAL A PERIODIC SAFETY TEST PROCEDURE (46CFR61.40-6)
Condition: Unknown
Due 17 November 1997
Resolved 17 November 1997
Engineering
Issued 15 August 1997 Resolved
PRIOR TO THE CARRIAGE OF PASSENGERS COMPLETE THE DESIGN VERIFICATION TEST PROCEDURE.
Condition: Unknown
Due 17 November 1997
Resolved 17 November 1997
Engineering
Issued 15 August 1997 Resolved
PRIOR TO THE CARRIAGE OF PASSENGERS PROVIDE A COPY OF THE ENGINEERING LOG MAINTAINED DURING CREW TRAINING PERIOD.
Condition: Unknown
Due 17 November 1997
Resolved 17 November 1997
Lifesaving
Issued 15 August 1997 Resolved
PRIOR TO THE CARRIAGE OF PASSENGERS CONDUCT A FIRE AND BOAT DRILL.
Condition: Unknown
Due 17 November 1997
Resolved 17 November 1997
Accommodation/Occupational Safety
Issued 15 August 1997 Resolved
SHOW MARINE SAFETY CENTER APPROVAL OF HVAC DWG. NO. 8110-012-01, SHEETS_x001C_ 9, 13, 17 THROUGH 22.
Condition: Unknown
Due 10 December 1997
Resolved 10 December 1997
Engineering
Issued 15 August 1997 Resolved
PRIOR TO THE CARRIAGE OF PASSENGERS DEMONSTRATE ENGINEERING PLANTS ABILITY UNDER VARYING LOAD CONDITIONS AND DURING NORMAL DOCKING MANEUVERS.
Condition: Unknown
Due 17 November 1997
Resolved 17 November 1997

Casualty record · 16

26 May 2002Routine · role: Involved in a Marine Casualty · activity 1622160
18 July 2002Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 1655829
20 May 2003Routine · role: Involved in a Marine Casualty · activity 1804977
12 June 2003Routine · role: Involved in a Marine Casualty · activity 1819034
6 January 2007Routine · role: Involved in a Marine Casualty · activity 2852705
9 January 2007Routine · role: Involved in a Marine Casualty · activity 2860489
19 August 2008Routine · role: Involved in a Marine Casualty · 1 injured · activity 3304029
19 August 2008Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 dead · activity 3304729
20 October 2008Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 3353656
13 September 2011Routine · role: Involved in a Marine Casualty · 1 dead · activity 4144450
8 December 2011Routine · role: Involved in a Marine Casualty · activity 4222968
2 October 2012Routine · role: Involved in a Marine Casualty · activity 4495516
17 September 2020Routine · role: Subject to Marine Inspection · activity 7061245
16 October 2021Routine · role: Involved in a Marine Casualty · activity 7334885
6 October 2023Routine · role: Involved in a Marine Casualty · activity 7813230
27 March 2026Routine · role: Involved in a Marine Casualty · activity 8333175
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.