MAURY USCG vessel records Sign in
← All vessels

EVELYN

EVELYN is a 1967 passenger vessel (inspected). The Coast Guard has recorded 24 inspections since 1981, most recently in November 2001, along with 17 deficiencies.

Records from 1981 to 2001. Most recent: inspection, 1 November 2001.

Built
1967
Last inspected
1 November 2001
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WCZ3087
Flag
UNITED STATES
—
Maury page id
psix-45508

Inspections, by type

…with no type recorded2
Years with a record 18 calendar years (1981–2001)
The 24 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 25 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)61.6 ft × 16.2 ft × 8.0 ft
Registered tonnagegross 57 / net 39
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderTELEDYNE INC · BERWICK, LA, UNITED STATES · built 1967
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 15 July 2025 · expires 31 August 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it39 - Regulatory (Subpart C or D), Net Ton
57 - Regulatory (Subpart C or D), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WCZ3087MMSI not assigned · expired · compulsorily equipped · granted 2 June 1999, cancelled 8 August 2009
WCX7638MMSI not assigned · expired · voluntarily equipped · granted 24 September 1997, cancelled 24 November 2007
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 24

1 November 2001 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 773070
16 May 2001 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1423573
22 June 2000 Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1462860
14 July 1999 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1097235
24 June 1999 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 884444
26 May 1999 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1449185
21 May 1998 Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1378379
19 May 1997 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1413166
25 May 1996 COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1445091
9 January 1995 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1168500
20 December 1994 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1425526
15 December 1993 COI Inspection · Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1410886
15 December 1992 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 831601
25 February 1992 Inclining Experiment
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1008832
21 January 1992 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1256130
17 December 1991 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 952490
19 December 1990 COI Inspection · Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1235339
19 December 1989 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 911177
15 December 1988 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1034012
14 December 1987 COI Inspection · Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1002529
20 November 1986 Re-Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1021050
29 July 1986 Re-Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1274322
21 November 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1284599
9 September 1981 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1277790

Deficiency record · 17

Fire Fighting
Issued 26 May 1999 Resolved
PROVIDE COVERS FOR ENGINE ROOM INTAKE/EXHAUST PORTS TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 26 May 1999
Resolved 26 May 1999
Lifesaving
Issued 26 May 1999 Resolved
PROVIDE PROPER FUNCTIONAL RESCUE PLATFORM. TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR, PRIOR TO 26 JUN 1999.
Condition: Unknown
Due 26 June 1999
Resolved 16 June 1999
Construction/Loadline
Issued 26 May 1999 Resolved
INSTALL CHECK VALVES IN ALL BILGE SUCTION LINES, TO THE SATISFACTION OF THEATTENDING MARINE INSPECTOR, PRIOR TO 26 JUN 1999.
Condition: Unknown
Due 26 May 1999
Resolved 26 May 1999
Construction/Loadline
Issued 20 December 1994 Resolved
DOUBLE HOSE CLAMP ALL THROUGH HULL FITTINGS. (ENGINE ROOM AND BELOW PASSENGER COMPARTMENT)
Condition: Unknown
Due 5 January 1995
Resolved 21 December 1994
Engineering
Issued 20 December 1994 Resolved
MAKE PROPER AND PERMANENT REPAIRS TO STARBOARD SIDE GENERATOR EXHAUST SYSTEM. (PROPERLY INSTALL DOUBLE CLAMPS ON RUBBER CONNECTION.)
Condition: Unknown
Due 20 January 1995
Resolved 21 December 1994
Engineering
Issued 20 December 1994 Resolved
INSTALL PROPER FLAME SCREENS ON BOTH PORT AND STARBOARD FUEL OIL TANK VENTS
Condition: Unknown
Due 20 December 1994
Resolved 20 December 1994
Engineering
Issued 20 December 1994 Resolved
MAKE PROPER AND PERMANENT REPAIRS TO THE EXHUAST SYSTEM STARBOARD MAIN ENGINE.(CURRENTLY "RED-HAND" PATCHED)
Condition: Unknown
Due 20 December 1994
Resolved 20 December 1994
Lifesaving
Issued 15 December 1993 Resolved
REPLACE WATER LIGHTS ON TOPSIDE BUOYANT APPARATUS AND AFT RING LIFE BUOY.
Condition: Unknown
Due 15 December 1993
Resolved 17 December 1993
Navigation
Issued 17 December 1991 Resolved
PROVE PROPER OPERATION OF WHEELHOUSE VHF RADIO
Condition: Unknown
Due 17 December 1991
Resolved 17 December 1991
Engineering
Issued 17 December 1991 Resolved
REPLACE SPLIT AND WASTED COUPLING AT TOP OF STBD FUEL TANK
Condition: Unknown
Due 17 December 1991
Resolved 17 December 1991
Accommodation/Occupational Safety
Issued 17 December 1991 Resolved
PERMANENTLY SECURE WATER PUMP PRESSURE TANK IN ACCOMODATION SPACE VOID
Condition: Unknown
Due 17 December 1991
Resolved 17 December 1991
Accommodation/Occupational Safety
Issued 17 December 1991 Resolved
INSTALL ELECTRICAL COVER ON WATER HEATER
Condition: Unknown
Due 17 December 1991
Resolved 17 December 1991
Electrical
Issued 17 December 1991 Resolved
PROVE PROPER OPERATION OF MACHINERY SPACE GENERATOR TO MARINE INSPECTOR
Condition: Unknown
Due 17 December 1991
Resolved 17 December 1991
Documentation
Issued 17 December 1991 Resolved
PROVIDE PROOF OF STABILITY OR DOCUMENTED EVIDENCE SHOWING TOTAL NUMBER OF PEOPLE CARRIED FOR DETERMINING SATISFACTORY STABILITY IN SERVICE, OR MAKE VESSEL AVAILABLE FOR SIMPLIFIED STABILITY TEST IAW 46 CFR 170.120(B) AND 170.160(B)
Condition: Unknown
Due 17 December 1991
Resolved 17 December 1991
Engineering
Issued 17 December 1991 Resolved
REPAIR/REPLACE FRACTURED (HOLED) STBD GENERATOR EHHAUST PIPE
Condition: Unknown
Due 17 December 1991
Resolved 17 December 1991
Construction/Loadline
Issued 17 December 1991 Resolved
REPLACE HOLED BILGE PIPING IN MACHINERY SPACE
Condition: Unknown
Due 17 December 1991
Resolved 17 December 1991
Engineering
Issued 17 December 1991 Resolved
REPAIR/REPLACE HOLED STBD ENGINE FEED WATER PIPING
Condition: Unknown
Due 17 December 1991
Resolved 17 December 1991

Ownership record