PT. SUR CLIPPER is a 1967 passenger vessel (inspected). The Coast Guard has recorded 117 inspections since 1985, most recently in January 2026, along with 262 deficiencies, 5 operational controls and 4 casualty investigations between 2001 and 2007.

Records from 1985 to 2026. Most recent: operational control imposed, 16 January 2026.

Built
1967
Last inspected
16 January 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WX8607
Flag
UNITED STATES
367011060
Maury page id
psix-45509

Inspections, by type

…with no type recorded14
Years with a record 40 calendar years (1985–2026)
The 117 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)45.3 ft × 18.3 ft × 5.0 ft
Registered tonnagegross 38 / net 27
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderNOR'WESTER BOAT CO. · MARYSVILLE WA, UNITED STATES · built 1967
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portMONTEREY, CA
Trade endorsementsCoastwise, unrestricted, Fishery
DocumentationValid · issued 14 November 2025 · expires 31 October 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it38 - Regulatory (Subpart C or D), Gross Ton
27 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WX8607MMSI 367011060 · active · compulsorily equipped · granted 26 February 2025, expires 27 February 2035
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 117

16 January 2026 Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8297499
18 April 2025 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8114201
16 April 2025 Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8100858
11 April 2025 Simplified Stability Test
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8105511
6 February 2025 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8075772
20 November 2024 Internal Structural Exam · Deficiency Check · Hull Examination · Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8023170
28 May 2024 In-Service Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7921888
30 October 2023 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7816401
25 October 2023 Deficiency Check · Internal Structural Exam · Hull Examination · Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7813833
31 August 2023 DAPI Audit · Deficiency Check · COI Inspection · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7782014
15 December 2022 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7612388
9 November 2022 Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7592004
16 December 2021 Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7366148
4 October 2021 Drydock Exam · Deficiency Check · Internal Structural Exam · Hull Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7326709
5 January 2021 Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7119406
17 January 2020 Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6891493
15 January 2020 Simplified Stability Test
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6891782
2 October 2019 Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6827929
10 October 2018 Administrative Inspection · COI Inspection · Internal Structural Exam · Deficiency Check · DAPI Audit
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6557913
20 September 2018 Administrative Inspection
Administrative · Navigation Center · Activity 6544556
7 February 2018 Administrative Inspection · DAPI Audit · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6350731
29 November 2017 Drydock Exam · Administrative Inspection · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6313980
2 March 2017 Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6096881
2 March 2016 Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5825343
18 November 2015 Drydock Exam · Examination of Repairs · Plan Review "T" Boat · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5766273
31 January 2012 Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4235189
12 December 2011 Drydock Exam · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4206690
14 December 2010 Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3910771
5 January 2010 Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3658367
16 December 2009 Hull Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3645935
15 December 2009 Deficiency Check · DAPI Audit
Physical examination · USCG Southwest District (dp) · USCG Southwest District (CGD-SW) · Activity 3651454
5 January 2009 Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3388776
1 December 2008 Deficiency Check · COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3369941
22 January 2008 Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3124743
5 December 2007 Hull Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3110143
1 October 2007 Plan Review "T" Boat
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3070763
22 March 2007 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2893625
22 January 2007 Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2862376
4 April 2006 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2640590
14 December 2005 Hull Examination · Deficiency Check · Plan Review "T" Boat
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2547168
13 October 2005 Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2509860
8 June 2005 Administrative Inspection
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2386314
30 May 2005 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2815249
30 May 2005 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2815413
25 April 2005 Simplified Stability Test
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2342178
26 January 2005 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2272329
22 January 2005 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2286776
16 December 2004 Annual Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2229407
2 December 2003 Deficiency Check · COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1939816
13 November 2003 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1939807
21 April 2003 Plan Review "T" Boat
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1777922
26 March 2003 Plan Review "T" Boat
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1763426
10 March 2003 Deficiency Check · COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1745906
13 February 2003 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1740830
10 September 2002 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1673373
21 August 2002 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1664306
5 August 2002 Damage Survey
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1655839
11 June 2002 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1629113
23 April 2002 Annual Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1606267
22 October 2001 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1076203
7 September 2001 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 772464
4 September 2001 Damage Survey
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1379558
3 September 2001 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1707828
6 June 2001 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1065956
20 March 2001 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1467276
13 February 2001 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1379311
6 March 2000 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1046380
28 February 2000 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1461245
2 June 1999 Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 808843
6 April 1999 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1430662
3 March 1999 Plan Review "T" Boat
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 805420
4 November 1998 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 805072
31 March 1998 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 787288
4 March 1998 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1449016
10 June 1997 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 23239
6 May 1997 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1364115
5 March 1997 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1095686
2 July 1996 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1086587
13 March 1996 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 885674
19 December 1995 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 872116
30 May 1995 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 873419
6 March 1995 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1168516
27 June 1994 Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1026120
2 June 1994 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1013322
12 May 1994 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1168459
14 March 1994 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 854362
5 January 1994 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1160623
1 June 1993 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 826559
3 May 1993 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1150366
25 March 1993 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 838843
30 October 1992 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 658414
9 October 1992 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 954018
25 July 1992 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1269467
7 July 1992 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 956926
1 June 1992 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 943596
8 April 1992 Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 951318
25 March 1992 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1264041
28 August 1991 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 937392
29 April 1991 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 999309
19 March 1991 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1214820
4 April 1990 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1233810
28 February 1990 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1217743
24 May 1989 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1209493
3 April 1989 Re-Inspection · Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 895838
20 December 1988 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1341732
6 September 1988 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1041130
18 July 1988 Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1338520
21 June 1988 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1202648
23 March 1988 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1290978
1 July 1987 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1013189
8 May 1987 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1330066
22 April 1987 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1007829
2 September 1986 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1337071
26 June 1986 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 992292
28 May 1986 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1301355
12 June 1985 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1285967
10 April 1985 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 982273

Deficiency record · 262

05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 28 January 2026 Resolved
Each vessel that operates of the high seas must have on board a FCC Type Accepted Cat 1, 406 MHz EPIRB, installed to automatically float free and activate. MI identified the EPIRB hydrostatic release did not have expiration date marked on unit.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 February 2026
Resolved 3 February 2026
02 - Structural Conditions › N/A - No Subsystem › Decks - cracking
Issued 28 January 2026 Resolved
Except as otherwise allowed by this subpart, a vessel must comply with the structural design requirement of one of the standards listed below for the hull material of the vessel. MI identified several areas of the aft deck with delamination that exposed the glass laminate to seawater intrusion
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 February 2026
Resolved 24 February 2026
Resolution: Received photo of repaired delamination on aft deck.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 28 January 2026 Resolved
All vessels must have navigation lights that are in compliance with the applicable sections of the International and Inland Navigation Rules. MI Identified inoperable anchor light and stern light.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 28 January 2026
Resolved 28 January 2026
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 28 January 2026 Resolved
The discharge ends of fuel tank vent pipes must be fitted with removable flame screens of flame arrestors. the flame screen must consist of a single screen of corrosion resistant wire of at least 30x30 mesh. MI identified non-metallic screens fitted over the discharge end of both fuel tank vents.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 February 2026
Resolved 9 February 2026
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 16 April 2025 Resolved
When the flexible section is a nonconductor of electricity, the metallic sections of the fill pipe separated thereby must be joined by a conductor for protection against generation of a static charge when filling with fuel. The Marine Inspector (MI) identified that the fuel tank fill pipes were not electrically bonded to the tank. Conduct repairs to the satisfaction of the attending Marine Inspector. 46 CFR 182.445(g)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 April 2025
Resolved 24 April 2025
Resolution: Received satisfactory video from operator showing that bonding wires were installed to fuel tank fill piping.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 16 April 2025 Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection giving consideration to provisions for a seaworthy hull, protection against fire, means of escape in case of a sudden unexpected casualty, guards and rails in hazardous places, ventilation of enclosed spaces, and necessary facilities for passengers and crew. The Marine Inspector identified cracked welds along the engine room door hatches; 4 on the port side and 1 on the starboard side. Conduct repairs to the satisfaction of the attending Marine Inspector. 46 CFR 177.100
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 April 2025
Resolved 24 April 2025
Resolution: Received satisfactory video evidence showing that cracked welds were repaired.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 16 April 2025 Resolved
A vessel must comply with the applicable requirements for any radio…installations, including the requirements for a station license and installation certificates to be issued by the Federal Communications Commission, as set forth in 47 CFR part 80. Every vessel subject to Part III of Title III of the Communications Act must have a detailed inspection of the radio installation by an FCC-licensed technician in accordance with § 80.59 once every five years…If the ship passes the inspection, the technician will issue a Communications Act Safety Radiotelephony Certificate. The Marine Inspector identified that the Radiotelephony Certficate was expired. Complete a satisfactory FCC Inspection and obtain a valid Radiotelephony Certificate. PARENT CITE: 46 CFR 184.502 47 CFR 80.903
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 April 2025
Resolved 28 April 2025
Resolution: Received satisfactory photograph of updated/new FCC Certificate.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 16 April 2025 Resolved
Each…ring life buoy must be marked in clearly legible block capital letters with the vessel's name. The Marine Inspector identified that the ring life buoy's markings were weathered and illegible. 46 CFR 185.604(b)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 April 2025
Resolved 17 April 2025
Resolution: Vessel provided documentation that they re-labeled their ring life buoy with the appropriate markings as per the regulation.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 16 April 2025 Resolved
Each ring life buoy with a floating waterlight must..secur[e] the waterlight around the body of the ring life. The Marine Inspector identified that the waterlight was not properly attached to the ring life buoy. 46 CFR 180.70(d)(2)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 April 2025
Resolved 17 April 2025
Resolution: Vessel operator provided evidence that they properly installed the waterlight to the body of the ring life buoy.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 6 February 2025 Resolved
Your vessel must undergo an annual inspection within the 3 months before or after each anniversary date. Due to extended dry docking period, vessel did not complete annual inspection within +/-90 day grace period; conduct annual inspection prior to the carriage of passengers. 46 CFR 176.500 (b)(1)
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 April 2025
Resolution: Vessel completed satisfactory Annual Inspection on 16 April 2025, and also corrected a safety item prior to clearance of 701 Operational Control
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 6 June 2024 Resolved
If during the inspection of a vessel, the vessel or its equipment is found not to conform to the requirements of law or the regulations in this subchapter, the marine inspector will point out deficiencies observed and discuss all requirements with the owner. Wood rot present in the following areas and require repair: main passenger cabin outboard of longitudinal frames on both sides; aft weatherdeck corner and outboard frames as well as framing near engine room ventilation trunks; port head overhead. Starboard head paneling requires removal for inspection. Submit repair plan prior to commencing repairs and coordinate satisfactory repairs with Sector SF Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 November 2024
Resolved 26 March 2025
Resolution: Verified condition of wood with paneling removed and subsequent repairs.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 June 2024 Resolved
If during the inspection of a vessel, the vessel or its equipment is found not to conform to the requirements of law or the regulations in this subchapter, the marine inspector will point out deficiencies observed and discuss all requirements with the owner. Forward hydraulic line under helm console is leaking and saturating wood deck that it passes through. Replace hydraulic line and affect repairs to deck.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 July 2024
Resolved 11 April 2025
Resolution: Verified hoses replaced.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 28 May 2024 Resolved
The intent of this part is to insure that the scantlings, material, fastenings, workmanship and arrangement of each vessel are such as to provide for safe operation in accordance with the terms of its certificate of inspection. The report provided by the third party indicated excessive rot on the salon roof. Remove all paneling to allow for further inspection of the material condition of the salon roof. 46 CFR 177.01-5 (a) "OLD T"
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 June 2024
Resolved 6 June 2024
Resolution: Paneling removed for inspection.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 28 May 2024 Resolved
No major repairs or alterations affecting the safety of the vessel with regard to the hull, machinery, or equipment, shall be made without the knowledge and approval of the Officer in Charge, Marine Inspection. On 28DEC2023, temporary repairs were made in multiple locations on the vessel after rotting wood was identified. Submit repair proposal for the following to the satisfaction of the marine inspector: 1. Replaced forward post on the port side windshield on the side of the wheelhouse. 2. Replaced inner structure of the upper part of the windshield. 3. Replaced door opening, structure, and lower section of the door and wall on the starboard side of the wheelhouse. 4. Replaced plywood above the forward windows on the port and starboard side of the salon. 46 CFR 176.20-1 (a) "OLD T"
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 June 2024
Resolved 26 March 2025
Resolution: Verified repairs.
09 - Working and Living Conditions › 092 - Working Conditions › Fitness for duty - intoxication
Issued 30 October 2023 Resolved
Each marine employer shall ensure that random drug tests conducted under this part are unannounced and that the dates for administering random tests are spread reasonably throughout the calendar year. Company has designated a vessel Master to serve as the Company Designated Employer Representative (DER). This arrangement does not allow for a random selection of crewmembers as intended by this regulation. Company to assign responsibilities of DER to an employee that is not one of the members that shall be randomly drug tested as required by this regulation.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 November 2023
Resolution: Received notification that company has elected a new DER. Uploaded information on new DER to Special Note. DER has received supervisor level training and all employees have been trained in EAP.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 13 September 2023 Resolved
Each survival craft must be stowed so that when the vessel sinks the survival craft floats free. Vessel's IBA painter line was not attached to the weak-link that would allow the IBA to detach when the vessel sinks. Vessel attached painter line to weak-link to the satisfaction of the attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 13 September 2023
Resolution: Vessel attached painter line to weak-link to the satisfaction of the attending marine inspector.
11 - Life Saving Appliances › N/A - No Subsystem › Immersion suits
Issued 13 September 2023 Resolved
The master of the vessel shall ensure that each EPIRB must be tested monthly, using the integrated test circuit and output indicator, to deterfmine that it is operative. The EPIRB test required shall be logged or otherwise documented. Vessel did not have monthly EPIRB tests logged. Vessel to show that they are testing EPIRB monthly via vessel log to the satisfaction of the marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 September 2023
Resolved 3 October 2023
Resolution: Vessel showed proof of EPIRB testing to the satisfaction of the marine inspector.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 13 September 2023 Resolved
As appropriate for the intended voyagew, a vessel must carry adequate and up-to-date U.S. Coast Pilot or similar publication. Vessel's Coast Pilot was out of date. Vessel to procure latest edition to the satisfaction of the marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 September 2023
Resolved 3 October 2023
Resolution: Vessel showed proof of purchase of up-to-date Coast Pilot.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 13 September 2023 Resolved
No flammable or combustible liquids may be stowed in any accommodation, control, or service space, other than a paint locker. Vessel has over 20 gallons of oil and paint stored in forward compartment. Vessel to remove all oil and paint to the satisfaction of the marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 September 2023
Resolved 3 October 2023
Resolution: Vessel removed access paint and oil to the satisfaction of the marine inspector.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 13 September 2023 Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. Electrical outlet in forward compartment missing face plate. Vessel to replace face plate to the satisfaction of the marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 September 2023
Resolved 3 October 2023
Resolution: Vessel installed face plate to electrical outlet to the satisfaction of the marine inspector.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 13 September 2023 Resolved
Each hatch exposed to the weather must be watertight. Engine compartment overhead hatches gasket material does not provide a watertight tight barrier. Vessel to replace gasket material to the satisfaction of the attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 September 2023
Resolved 29 January 2024
Resolution: Vessel repalced gasket to provide watertight barrier.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 13 September 2023 Resolved
Machinery and fuel tank spaces shall be separated from accommodation spaces by watertight and/or vapor tight bulkheads. Bulkhead between fuel tank compartment and engine compartment has multiple bulkhead penetrations. Vessel to fill penetrations to the satisfaction of the marine inspector. 46 CFR 182.35-1(a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 September 2023
Resolved 3 October 2023
Resolution: Vessel filled bulkhead penetrations to the satsifaction of the marine inspector.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 13 September 2023 Resolved
An EAP training program must be conducted for the employer's crewmembers and supervisory personnel. The training program must include at least the following elements: the effects and consequences of drug and alcohol use on personal health, safety, and work environment; the manifestations and behavioral cues that may indicate drug and alcohol use and abuse; and documentation of training given to crewmembers and the employer's supervisory personnel. Supervisory personnel must receive at least 60 minutes of training. Vessel does not have records of EAP training. Vessel to provide evidence of training of the supervisor as well as training to the crewmembers to the satisfaction of the marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 September 2023
Resolved 4 November 2023
Resolution: Operator confirmed employees have recieved EAP training
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 13 September 2023 Resolved
Each EAP education program must include at least the following elements: display and distribution of informational material; display and distribution of a community service hot-line telephone number for crewmember assistance, and display and distribution of the employer's policy regarding drug and alcohol use in the workplace. Vessel does not have employer's policy displayed. Vessel procured and displayed company's policy to the satisfaction of the attending marine inspector. 46 CFR 46.401(a)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 October 2023
Resolved 13 September 2023
Resolution: Vessel procured and displayed company's policy to the satisfaction of the attending marine inspector.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 9 November 2022 Resolved
An adult life jacket must be provided for each person carried on board a vessel. 05 of the adult life jackets were of kapok design and were leaking air.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 November 2022
Resolved 18 January 2023
Resolution: Received sufficient evidence of new lifejackets put into service onboard.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 9 November 2022 Resolved
Vessels shall be inspected for compliance with the standards...acceptable to the Officer in Charge, Marine Inspection, as good marine practice. There were two sections of deck railing, one on the bow and one port side of the vessel, that were not secured in place. 46 CFR 176.25-1(a) "Old T"
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 November 2022
Resolved 18 January 2023
Resolution: Recieved sufficient evidence of repairs made to the railings.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 9 November 2022 Resolved
Each vessel that operates on the high seas, or that operates beyond three miles from the coastline of the Great Lakes, must have on board a FCC Type Accepted Category 1, 406 MHz EPIRB, installed to automatically float free and activate. There was no expiration date marked on the hydrostatic release for the EPIRP.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 November 2022
Resolved 6 December 2022
Resolution: Received documentation of new hydrostatic release installed onboard with proper expiration markings.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 9 November 2022 Resolved
Each survival craft must be secured to the vessel by a painter with a float-free link permanently attached to the vessel. The painter line was not attached to the hydrostatic release of the IBA.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 9 November 2022
Resolved 9 November 2022
Resolution: Witnessed the painter line being attached to the hydrostatic release of the IBA.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 16 December 2021 Resolved
An adult life jacket must be provided for each person carried on board a vessel. Five lifejackets were found to have not passed inspection. Vessel limited to no more than total 45 persons on board.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 26 January 2022
Resolution: Representative sent photos of new lifejackets installed.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 16 December 2021 Resolved
Each rescue boat and life ring buoy must be marked with Type II retroreflective material approved in accordance with 46 CFR 164.018 or other standard specified by the Commandant. Retroreflective material was found to be faded beyond the ability to reflect light.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 December 2021
Resolved 21 January 2022
Resolution: Representative sent photo of deficiency resolved.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 16 December 2021 Resolved
Each opening in an exposed weather deck must have a means for closing it weathertight. Main deck is leaking around engine compartment hatch. This is causing rot in the wood deck beams in that compartment. Repair proposal submitted. Deficiency due to be corrected by 28FEB2022.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 February 2022
Resolved 9 November 2022
Resolution: Attending MI verified replacement of prior soft patch repair and tested the hatches for weathertighness.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 16 December 2021 Resolved
A vessel must be operated in accordance with applicable laws and regulations in such a manner as to afford adequate precaution against hazards that might endanger the vessel and the persons being transported. Deck above steering compartment is soft and lacking support. Repair proposal submitted. Extended: Deficiency due to be corrected by 28FEB2022.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 28 February 2022
Resolved 9 November 2022
Resolution: Attending MI verified replacement of wooden supports.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 16 December 2021 Resolved
Vapor barriers must be provided where insulation of any type is used in spaces where flammable and combustible liquids or vapors are present, such as machinery spaces. Electrical cable penetrating bulkheads in and out of engine room needs to be secured for vapor barrier protection.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 January 2022
Resolved 26 January 2022
Resolution: Representative sent photo of vapor barrier protection installed.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 16 December 2021 Resolved
A vessel must be operated in accordance with applicable laws and regulations in such a manner as to afford adequate precaution against hazards that might endanger the vessel and the persons being transported. Bilge pumping arrangements was found to have multiple issues: 1. Steering compartment bilge pump wiring is lacking support. Remove wiring from bilge, clear and dead end wires, and properly support wiring. 2. Bilge pump by fuel tanks has excessive hose length that is causing excess strain on the pump. Shorten hose length to appropriate length. Extended: Deficiency due to be corrected by 28FEB2022.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 28 February 2022
Resolved 9 November 2022
Resolution: Attending MI verified installation of supports for wiring and removal of excess hose and wires.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 16 December 2021 Resolved
Strong and effective rudder stops must be provided to prevent jamming and damage to the rudder and its fittings. These stops must be structural or internal to the main steering gear. Vessel is not fitted with rudder stops. Submit repair proposal within 30 days. Extended: Deficiency due to be corrected by 28FEB2022.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 28 February 2022
Resolved 9 November 2022
Resolution: Attending MI verified installation of rudder stops.
14 - Pollution Prevention › 141 - MARPOL Annex I › Pumping, piping and discharge arrangements
Issued 5 January 2021 Resolved
A vessel is inspected for compliance with the standards required by this chapter. Machinery equipment materials and arrangements not covered by standards in this subchapter may be inspected in accordance with standards acceptance to the cognizant OCMI as good marine practice. Valve for bilge pump prime has wasted from the pump side of the line and is unable to be capped. New valve and piping required to be installed at through hull penetration. 46CFR176.800
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 January 2021
Resolution: Operator sent picture of cracked pipe and wasted valve replacement.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 5 January 2021 Resolved
At each initial and subsequent inspection for certification of a vessel the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspections of the hull structure and its appurtenances, including the following: Inspection of all accessible parts of the exterior and interior of the hull. Vessel was found to have damage on the stem just above the waterline creating a thin spot in the fiberglass. Repair damage to original construction. 46CFR176.802(a)(1)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 February 2021
Resolved 8 January 2021
Resolution: Operator sent picture of fiberglass repair to stem.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 5 January 2021 Resolved
Each survival craft must be stowed so that when the vessel sinks the survival craft floats free and, if inflatable, inflates automatically. IBA painter was found to be attached to vessel instead of weak link on hydrostatic release. 46CFR180.130(a)(2)
Action required: 10 - Deficiency Rectified
Resolved 5 January 2021
Resolution: Attending MI witnessed operator attach painter to weak link on hydrostatic release.
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 5 January 2021 Resolved
At each initial and subsequent inspection for certification, the marine inspector may require that an abandon ship or man overboard drill be held under simulated emergency conditions specified by the inspector. Drills were not conducted because the boat did not get underway due to a no sail item. Drills are required to be conducted prior to carriage of passengers. 46CFR176.808(g)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 January 2021
Resolution: Marine inspector witnessed drills.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 5 January 2021 Resolved
The general construction of the vessel must be such as to minimize fire hazards insofar as it is reasonable and practicable. Wire run on engine room forward bulkhead was not vapor tight. 46CFR177.405(a)
Action required: 10 - Deficiency Rectified
Resolved 5 January 2021
Resolution: Operator used fire stop to create a vapor tight barrier in wire run.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 10 October 2018 Resolved
Found 02 life jackets with retro that was wasted.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 November 2018
Resolved 11 October 2018
Resolution: Vessel sent picture with new retro on lifejackets.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 10 October 2018 Resolved
Life jacket placard was unreadable due to fading.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 November 2018
Resolved 11 October 2018
Resolution: Vessel bought new life jacket placard.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 10 October 2018 Resolved
Engine room bulckhead had several penetrations through cable run through holes and had wasted gasket on engine room hatches IAW 46CFR 177.405(e)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 November 2018
Resolved 10 October 2018
Resolution: Vessel bought new gasket for engine room hatch cover, and plugged bulkhead penetrations.
04 - Emergency Systems › N/A - No Subsystem › Emergency fire pump and its pipes
Issued 10 October 2018 Resolved
Electrical bilge pump discharge hose in fuel tank room had puncture leak.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 11 October 2018
Resolved 10 October 2018
Resolution: Vessel bought and installed new discharge hose for bilge pump.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 10 October 2018 Resolved
Alcohol Strips were expired.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 11 October 2018
Resolved 11 October 2018
Resolution: Recieved documentation of new alcohol strips.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 20 September 2018 Resolved
NAME: Vsl is broadcasting incorrect Name, ZERO LENGTH OR BEAM: no dimension information (AIS Antenna Position ABCD values equals 0)
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 10 October 2018
Resolution: Tested vessel's AIS with other vessels while conducting Man Overboard Drill.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 7 February 2018 Resolved
Prove proper operation of masthead light in accordance with International and Inland Navigation Rules (Rule 23) in which a masthead light is defined by 33CFR83.21a (Rule 21) 46CFR183.420, 33CFR83.23
Due 1 March 2018
Resolved 6 March 2018
Accommodation/Occupational Safety › Occupational Safety › Hand Grab
Issued 29 November 2017 Resolved
02 deck rail pedestals were significantly wasted and require repair/replacement IAW 46 CFR 177.900.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 December 2017
Resolved 10 October 2018
Resolution: Found hand rails in good condition after drydock repais.
Deck/Cargo › Mooring/Anchoring › Anchor Chain (general)
Issued 29 November 2017 Resolved
Anchor chain significantly wasted & requires replacement by next Annual Inspection IAW 46 CFR 184.300.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 March 2018
Resolved 10 October 2018
Resolution: Found anchor chain replaced in kind with new chain.
Construction/Loadline › Penetrations › Gasket
Issued 29 November 2017 Resolved
Engine room bulkhead had several holes that affected vapor tightness & requires repair IAW 46 CFR 177.405(e).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 December 2017
Resolved 10 October 2018
Resolution: Rectified.
Construction/Loadline › Hull › Hull Plating
Issued 24 November 2015 Resolved
Provide repair plan proposal for FRP delamination at port and starboard rudder stock mounting connection.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 December 2015
Resolved 4 December 2015
Resolution: Delamination determined to be excess fabric from an improperly faired repair. Remaining repair has good bond with older hull materials.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 14 December 2010 Resolved
Provide 13 new adult PFD's. Limited to max 36 passengers on limited coastwise route.
Action required: 705 - Other - as specified
Due 29 December 2010
Resolved 23 December 2010
Resolution: Operator provided proof of purchase for 13 new adult type-I lifejackets and photos of proper markings.
Documentation › Certificates/Documents › FCC SSL
Issued 14 December 2010 Resolved
Provide MMSI number and ship specific radio station license.
Action required: 705 - Other - as specified
Due 29 December 2010
Resolved 28 January 2011
Resolution: Determined that a ship specific MMSI and call sign existed within the FCC Database. Ensured all info matched vessel details in MISLE. Provided operator with reference copy, and reminded him that he would need to ensure an original license is provided.
Engineering › Bilge Water Management System › Valve
Issued 14 December 2010 Resolved
Renew port bilge manifold suction valve.
Action required: 705 - Other - as specified
Due 29 December 2010
Resolved 23 December 2010
Resolution: Operator replaced the port bilge manifold suction valve.
Fire Fighting › Structural - Horizontal Zones › General
Issued 14 December 2010 Resolved
Provide air tight bulkhead on forward engine space.
Due 29 December 2010
Resolved 23 December 2010
Resolution: Operator provided photo of bulkhead area in question, and sealed the non-air tight areas with foam.
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 6 January 2010 Resolved
Provide updated currents.
Condition: Unknown
Action required: 705 - Other - as specified
Due 5 February 2010
Resolved 1 February 2010
Resolution: Updated currents onboard vessel.
Fire Fighting › Remote Fuel Shutoff › General
Issued 6 January 2010 Resolved
Label emergency fuel shut off valves.
Action required: 705 - Other - as specified
Due 5 February 2010
Resolved 1 February 2010
Resolution: Emergency fuel shut offs labeled.
Engineering › Bilge Water Management System › Valve
Issued 16 December 2009 Resolved
Renew/Replace in kind 1/ 1/4" bilge manifold overboard discharge valve.
Action required: 705 - Other - as specified
Due 4 January 2010
Resolved 23 December 2009
Resolution: Replaced valve with new
Engineering › Bilge Water Management System › Strainer
Issued 16 December 2009 Resolved
Properly repair/replace bilge suction piping strainer in the FWD battery compartment
Action required: 705 - Other - as specified
Due 4 January 2010
Resolved 23 December 2009
Resolution: Re-installed strainer
Pollution Prevention/Response › Prevention Equipment › Sewage System Piping
Issued 16 December 2009 Resolved
Renew/replace in kind, 3/4" suction valve for sewage flush system
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 January 2010
Resolved 16 December 2009
Resolution: Replaced valve with new and tested.
Documentation › Logs/Records › Drug Test Records
Issued 15 December 2009 Resolved
Company did not have result/exemptions for pre-employment testing prior for individuals working in a safety sensitive position, as required by 46 CFR 16.210.
Due 15 January 2010
Resolved 15 December 2009
Documentation › Logs/Records › Drug Test Records
Issued 15 December 2009 Resolved
Arrangements not made for post-casualty testing as required by 46 CFR 16.240
Due 15 January 2010
Resolved 15 December 2009
Documentation › Logs/Records › Drug Test Records
Issued 15 December 2009 Resolved
Alcohol testing devices not onboard as required by 46 CFR 4.
Due 15 January 2010
Resolved 15 December 2009
Documentation › Logs/Records › Drug Test Records
Issued 15 December 2009 Resolved
Crewmembers not properly trained prior to assuming safety sensitive positions regarding company's drug and alcohol policy in accordance with 46 CFR 16.401.
Due 15 January 2010
Resolved 4 January 2010
Documentation › Logs/Records › Drug Test Records
Issued 15 December 2009 Resolved
Supervisors has no proof of 1 hr of Employee Assistance Program (EAP) training as required by 46 CFR 16.401.
Due 15 January 2010
Resolved 4 January 2010
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 1 December 2008 Resolved
Provide 13 Adult Type I Pfd's with lights.
Condition: Improper/Lack of Maintenance
Due 1 January 2009
Resolved 4 December 2008
Resolution: Corrected
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 1 December 2008 Resolved
Provide 01 Child size Type I PFD with light.
Condition: Improper/Lack of Maintenance
Due 1 January 2009
Resolved 4 December 2008
Resolution: Corrected
Electrical › Electrical Distribution System (service) › Wiring
Issued 1 December 2008 Resolved
Secure all loose/bare wires under bridge console.
Condition: Improper Installation
Due 1 January 2009
Resolved 19 December 2008
Resolution: Corrected
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 1 December 2008 Resolved
Provide handles and locking devices for both sewage overboard discharge valves.
Condition: Improper/Lack of Maintenance
Due 1 January 2009
Resolved 19 December 2008
Resolution: Corrected
Engineering › Bilge Water Management System › Manifold
Issued 1 December 2008 Resolved
Label bilge suction manifold to indicate which line goes to which compartment.
Condition: Improper/Lack of Maintenance
Due 1 January 2009
Resolved 2 December 2008
Resolution: Corrected
Electrical › Electrical Distribution System (service) › Wiring
Issued 1 December 2008 Resolved
Secure loose/bare wires in overhead of the lower forwarded compartment.
Condition: Improper/Lack of Maintenance
Due 1 January 2009
Resolved 19 December 2008
Resolution: Corrected
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 1 December 2008 Resolved
Provide EAP, Policy Statement and Hotline Number and post onboard vessel.
Condition: Unknown
Due 1 January 2009
Resolved 19 December 2008
Resolution: Corrected
Fire Fighting › Remote Fuel Shutoff › General
Issued 1 December 2008 Resolved
Label both emergency fuel shut-off valves.
Condition: Improper/Lack of Maintenance
Due 1 January 2009
Resolved 2 December 2008
Resolution: Corrected
Fire Fighting › Remote Fuel Shutoff › General
Issued 1 December 2008 Resolved
Prove proper operation of the stbd emergency fuel shut-off valve.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 January 2009
Resolved 2 December 2008
Resolution: Corrected
Electrical › Electric Supply System (service) › Cable
Issued 12 February 2008 Resolved
Properly support electrical wire in way of upper deck by life floats.
Action required: 705 - Other - as specified
Resolved 12 February 2008
Lifesaving › Lifefloat › Painter
Issued 12 February 2008 Resolved
Properly attach sea painter to life floats.
Action required: 705 - Other - as specified
Resolved 12 February 2008
Lifesaving › Lifefloat › Paddle
Issued 12 February 2008 Resolved
Properly out fit life floats with two paddles each.
Action required: 705 - Other - as specified
Resolved 12 February 2008
Lifesaving › Lifejacket/PFD (Type I) › Lights
Issued 12 February 2008 Resolved
Renew light on 1 child type one PFD.
Action required: 705 - Other - as specified
Resolved 12 February 2008
Engineering › Shafting/Propeller Arrangements › Bearing
Issued 14 December 2005 Resolved
Replace port and starboard shaft bearings as per 46 CFR 176.630 prior to vessel receiving credit drydock.
Action required: 705 - Other - as specified
Resolved 10 January 2006
Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 14 December 2005 Resolved
Provide plans IAW 46 CFR 176.612 addressing repairs to extensive furring and splintering due to wet rot in way of overhead beams in lazarette, fuel compartment, and engine room; excessive furring in way of watertight bulkhead between fuel compartment and engine room; and wood rot in way of starboard side overhead in engine room.
Due 14 January 2006
Resolved 21 December 2005
Electrical › Electrical Distribution System (service) › Wiring
Issued 14 December 2005 Resolved
Provide support for loose electrical wiring in way of lazarette, fuel compartment, and engine room IAW 46 CFR 183.340(b)(4)
Due 14 January 2006
Resolved 10 January 2006
Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 14 December 2005 Resolved
Conduct repairs to wood rot as per approved plans required by item 02 in way of overhead beams in lazarette, fuel compartment, and engine room; in way of watertight bulkhead between fuel compartment and engine room; and in way of starboard side overhead in engine room.
Due 14 January 2006
Resolved 10 January 2006
Navigation › Piloting/Steering › Coast Guard Light List
Issued 13 October 2005 Resolved
Show proof of updates for CG light list for vessel route
Due 13 November 2005
Resolved 14 December 2005
Navigation › Piloting/Steering › US Coast Pilot
Issued 13 October 2005 Resolved
Show proof of updates for US Coast Pilot for vessel route.
Due 13 November 2005
Resolved 14 December 2005
Lifesaving › Lifefloat › Retroreflective Material
Issued 13 October 2005 Resolved
Renew retroreflective tape on 15 passenger lifefloat IAW 46CFR185.604 (i)
Due 13 November 2005
Resolved 14 December 2005
Engineering › Fuel Oil Service System › Ventilation
Issued 13 October 2005 Resolved
Renew 30 X 30 mesh screens on both port & stbd F/O tank vents.
Due 13 November 2005
Resolved 14 December 2005
Electrical › Electric Supply System (service) › Cable
Issued 13 October 2005 Resolved
Deadend loose wire in battery compartment identified & pointed out to the master by the attending Marine Inspector.
Due 13 November 2005
Resolved 14 December 2005
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 13 October 2005 Resolved
Provide asprin for first aid kit.
Due 13 November 2005
Resolved 14 December 2005
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 13 October 2005 Resolved
Renew rejected Adult type 1 lifejacket IAW 46 CFR 180.71 (c). Vessel is restricted to carry not more than 50 person onboard until corrected.
Due 13 November 2005
Resolved 15 December 2005
Engineering › Fuel Oil Service System › Hose
Issued 13 October 2005 Resolved
Install both port & stbd fuel oil supply lines to engines through aft engine room bulkhead IAW 46 CFR 182.720 (e) (3) (ii) for a credit drydock.
Due 13 November 2005
Resolved 14 December 2005
Lifesaving › Lifejacket/PFD (Type I) › Marking
Issued 13 October 2005 Resolved
Renew labeling on all type 1 PFD's IAW 46 CFR 185.604
Due 13 October 2005
Resolved 13 October 2005
Engineering › Diesel Engine (propulsion-reduction gear) › Cylinder Head
Issued 26 January 2005 Resolved
Provide proof of repair and operation of the Port Main Diesel Engine, prior to carrying passengers for hire.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 February 2005
Resolved 3 February 2005
Resolution: installed two new cylinder heads on port main diesel engine.
Engineering › Bilge Water Management System › Strainer
Issued 16 December 2004 Resolved
Secure electric bilge pump in way of lazaratte IAW 46 CFR 182.520.
Due 16 January 2005
Resolved 17 December 2004
Resolution: Electric bilge pump in way of lazaratte secured in place.
Engineering › Fuel Oil Service System › Valve, Control
Issued 16 December 2004 Resolved
Secure fuel/oil remote reach cup to overhead in way of fuel tank compartment.
Due 16 January 2005
Resolved 26 January 2005
Engineering › Bilge Water Management System › Strainer
Issued 16 December 2004 Resolved
Install bilge suction strainer of fixed system in way of fuel tank compartment IAW 46 CFR 182.520.
Due 16 January 2005
Resolved 26 January 2005
Electrical › Electrical Distribution System (service) › Wiring
Issued 16 December 2004 Resolved
Support all electrical wires in way of lazaratte and fuel compartment IAW 46 CFR 183.340.
Due 16 January 2005
Resolved 26 January 2005
Engineering › Bilge Water Management System › Valve
Issued 16 December 2004 Resolved
Install shut off valve for through hull fitting for electric bilge pump in way of fuel tank compartment IAW 46 CFR 182.520.
Due 16 January 2005
Resolved 17 December 2004
Resolution: Shut off valve for through hull fitting for electric bilge pump in way of fuel tank compartment installed.
Engineering › Bilge Water Management System › Valve
Issued 16 December 2004 Resolved
Install shut off valve for through hull fitting for electric bilge pump in way of battery compartment IAW 46 CFR 182.520.
Due 16 January 2005
Resolved 26 January 2005
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 16 December 2004 Resolved
Secure main deck starboard side handrails in way of slip-joints #4-5 and #7-11 from aft IAW 46 CFR 177.900.
Due 16 January 2005
Resolved 26 January 2005
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 16 December 2004 Resolved
Provide proper number of approved lifejackets (51 adult/ 6 child) reflected on COI onboard vessel IAW 46 CFR 180.71. Vessel is restricted to carrying 47 passengers until corrected.
Due 16 January 2005
Resolved 17 December 2004
Resolution: Provided 4 adult and 1 child approved PFDs. Proper number of PFDs (51 adult/ 6 child) as reflected on COI are onboard vessel.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 16 December 2004 Resolved
Renew lifering waterlight IAW 46 CFR 180.70.
Due 16 January 2005
Resolved 26 January 2005
Stability › Watertight Integrity › General
Issued 16 December 2004 Resolved
Install shut-off valve in way of Bait tank overboard discharge through hole fitting located on the starboard side fuel tank compartment IAW 46 CFR 179.350
Due 16 January 2005
Resolved 26 January 2005
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 16 December 2004 Resolved
Renew cracked plexi-glass window in way of main deck port side IAW 46 CFR 176.830.
Due 16 January 2005
Resolved 26 January 2005
Communications › Radio Communications › Radiotelephone Transceiver (2-4 MHz)
Issued 16 December 2004 Resolved
Prove proper operation of single-side band radio IAW 46 CFR 184.502. Vessel's route is limited to no more than 20NM from shore until corrected.
Due 28 December 2006
Resolved 28 November 2006
Resolution: Re-Issued at this inspection
Engineering › Bilge Water Management System › Strainer
Issued 16 December 2004 Resolved
Properly secure electric bilge pump in way of battery compartment IAW 46 CFR 182.520.
Due 16 January 2005
Resolved 26 January 2005
Lifesaving › Lifefloat › Painter
Issued 16 December 2004 Resolved
Properly secure sea painter for both lifefloat groups to painter attachment fitting or around the body of lifefloat IAW 46 CFR 180.137.
Due 16 January 2005
Resolved 26 January 2005
Lifesaving › Lifefloat › Painter
Issued 16 December 2004 Resolved
Properly connect lifefloat tandem lines around body of lifefloats or to painter attachment fitting IAW 46 CFR 180.137.
Due 16 January 2005
Resolved 26 January 2005
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 16 December 2004 Resolved
Properly attach lifefloat waterlight lanyards around body of lifefloats IAW 46 CFR 180.175.
Due 16 January 2005
Resolved 26 January 2005
Documentation › Logs/Records › Logbook (official)
Issued 16 December 2004 Resolved
Create life saving equipment maintenance log IAW 46 CFR 185.702.
Due 16 January 2005
Resolved 26 January 2005
Stability › Watertight Integrity › General
Issued 16 December 2004 Resolved
Make electric bilge pump through hull fitting in way of fuel tank compartment watertight IAW 46 CFR 179.350.
Due 16 January 2005
Resolved 17 December 2004
Resolution: Electric bilge pump through hull fitting in way of fuel tank compartment made watertight IAW CFR 179.350.
Stability › Watertight Integrity › General
Issued 16 December 2004 Resolved
Provide plans to make starboard side main deck watertight at sheer clamp in way of lazarette and fuel tank compartment upon further inspection IAW 46 CFR 178.410. Schedule inspection by USCG MI once deck is opened up.
Due 16 January 2005
Resolved 17 December 2004
Lifesaving › Lifejacket/PFD (General) › Lights
Issued 16 December 2004 Resolved
Renew 2 waterlights in way of 2 adult lifejackets. Owner replaced 2 waterlights. COS 12/16/04.
Due 16 January 2005
Resolved 16 December 2004
Resolution: Owner replaced 2 waterlights. COS 12/16/04.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 16 December 2004 Resolved
Renew port navigation light.
Due 16 January 2005
Resolved 16 December 2004
Resolution: Port navigation light renewed. Master corrected on the spot 12/16/04 by screwing in lightbulb.
Personnel › Certificates/Documents/Licenses
Issued 2 December 2003 Resolved
Provide designation letter for Senior Deckhands.
Action required: 705 - Other - as specified
Due 8 December 2003
Resolved 31 January 2004
Documentation › Markings/Placards
Issued 2 December 2003 Resolved
Provide life jacket donning placard.
Action required: 705 - Other - as specified
Due 8 December 2003
Resolved 31 January 2004
Lifesaving
Issued 2 December 2003 Resolved
Repair 15 person life float.
Action required: 705 - Other - as specified
Due 8 December 2003
Resolved 31 January 2004
Construction/Loadline › Structures
Issued 13 November 2003 Resolved
Repair cracks in deck coating in way of Bow, Embarcation Ladder, and lazarette entry way hatch. LEGACY COMPONENT DESC: Deck Plating
Action required: 705 - Other - as specified
Due 12 December 2003
Resolved 2 December 2003
Construction/Loadline › Structures
Issued 13 November 2003 Resolved
Abate furring in way of fuel tank space overhead and deck beams. LEGACY COMPONENT DESC: Deck Plating
Action required: 705 - Other - as specified
Due 5 December 2003
Resolved 2 December 2003
Construction/Loadline
Issued 13 November 2003 Resolved
Replace deck patch (approximately 1sf) in way of bow foreward of the superstructure. Re-seal deck as original.
Action required: 705 - Other - as specified
Due 13 December 2003
Resolved 2 December 2003
Engineering › Diesel Engine (propulsion-direct drive)
Issued 13 November 2003 Resolved
Make covers for remote fuel shutoffs watertight. LEGACY COMPONENT DESC: Valve
Action required: 705 - Other - as specified
Due 13 December 2003
Resolved 2 December 2003
Engineering › Bilge Water Management System
Issued 10 March 2003 Resolved
Label bilge manifold in regard to spaces having suction lines. LEGACY COMPONENT DESC: Manifold
Action required: 705 - Other - as specified
Due 10 April 2003
Resolved 1 April 2003
Resolution: labeled bilge manifold.
Stability › Watertight Integrity
Issued 10 March 2003 Resolved
Make engine space hatches watertight and means to secure in closed position. LEGACY COMPONENT DESC: Hatches
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 March 2003
Resolved 6 May 2003
Resolution: Tested sat, with garden hose.
Deck/Cargo › Mooring/Anchoring
Issued 10 March 2003 Resolved
Prove anchor & anchor line in place & functional. LEGACY COMPONENT DESC: Anchor
Action required: 705 - Other - as specified
Due 10 April 2003
Resolved 1 April 2003
Resolution: In place and functional.
Electrical › Lighting (service)
Issued 10 March 2003 Resolved
Replace and repair as new 2 lights with light bulbs & protective covers in forward berth, aft of collision bulkhead. LEGACY COMPONENT DESC: Lighting Fixture
Action required: 705 - Other - as specified
Due 10 March 2003
Resolved 1 April 2003
Resolution: Removed the two lights.
Accommodation/Occupational Safety › Occupational Safety
Issued 10 March 2003 Resolved
Provide machinery guards for working machinery and V-belts. LEGACY COMPONENT DESC: Guards for Exposed Hazards
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 April 2003
Resolved 1 April 2003
Resolution: Provided machinery guards.
Accommodation/Occupational Safety › Occupational Safety
Issued 10 March 2003 Resolved
Secure cables from working machinery in engine space. LEGACY COMPONENT DESC: Guards for Exposed Hazards
Action required: 705 - Other - as specified
Due 10 April 2003
Resolved 1 April 2003
Resolution: Secured cables.
Electrical › Electrical Distribution System (service)
Issued 10 March 2003 Resolved
Remove, replace, or cap dead-end wire in center lazerette bilge. LEGACY COMPONENT DESC: Wiring
Action required: 705 - Other - as specified
Due 10 April 2003
Resolved 1 April 2003
Resolution: Removed wire.
Electrical › Electrical Distribution System (service)
Issued 10 March 2003 Resolved
Remove or cap dead-end wire to junction box mounted on starboard forward bulkhead in lazerette. LEGACY COMPONENT DESC: Wiring
Action required: 705 - Other - as specified
Due 10 April 2003
Resolved 1 April 2003
Resolution: Wrapped with electical tape.
Fire Fighting › Miscellaneous Items
Issued 10 March 2003 Resolved
Make fuel oil space fume tight. LEGACY COMPONENT DESC: Insulation (Penetration of Oil/Oil Vapors)
Action required: 705 - Other - as specified
Due 10 April 2003
Resolved 6 May 2003
Fire Fighting › Combustible Materials
Issued 10 March 2003 Resolved
Remove excessive fuel oil in fuel tank space (1.5 gallons). LEGACY COMPONENT DESC: Fuel oil
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 April 2003
Resolved 6 May 2003
Stability › Watertight Integrity
Issued 10 March 2003 Resolved
Make lazerette forward bulkhead watertight. LEGACY COMPONENT DESC: Lazerette
Action required: 705 - Other - as specified
Due 10 April 2003
Resolved 6 May 2003
Resolution: Inspected satisfactory.
Communications › Radio Communications
Issued 10 March 2003 Resolved
Prove operation of radios. LEGACY COMPONENT DESC: Radios
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 May 2003
Lifesaving › Lifebuoys
Issued 10 March 2003 Resolved
Insure life ring is IAW 46CCFR 180.70. Currently life ring line is too long leading to light and retro is peeling off (lifeline must tied around body of lifering and must be able to pay out quickly). LEGACY COMPONENT DESC: Buoyant Lifeline
Action required: 705 - Other - as specified
Due 10 April 2003
Resolved 6 May 2003
Lifesaving › Lifebuoys
Issued 10 March 2003 Resolved
Life ring light not IAW 46 CFR 180.70, life ring light is full of water and batteries are expired. LEGACY COMPONENT DESC: Water light
Action required: 705 - Other - as specified
Due 10 April 2003
Resolved 6 May 2003
Resolution: Replaced batteries and provided dry water light.
Lifesaving › Rigid Liferafts
Issued 10 March 2003 Resolved
Life floats do not meet requirements of 46 CFR 180.15. Paddles are not stowed, 2 15-man lifefloats need to be patched, waterlight batteries need to be replaced & repair or replace lights that are full of water (water light must be permanently attached to lifefloats). LEGACY COMPONENT DESC: Carriage Requirement
Action required: 705 - Other - as specified
Due 10 April 2003
Resolved 6 May 2003
Electrical › Electrical Distribution System (service)
Issued 10 March 2003 Resolved
Insure all new installed wire runs meet the requirements of 46 CFR 183.340. LEGACY COMPONENT DESC: Wiring
Action required: 705 - Other - as specified
Due 10 April 2003
Resolved 1 April 2003
Resolution: Met requirements.
Electrical › Electrical Distribution System (service)
Issued 10 March 2003 Resolved
Insure electrical switches meet requirements IAW 46 CFR 183.05-35. LEGACY COMPONENT DESC: Switch
Action required: 705 - Other - as specified
Due 10 April 2003
Resolved 1 April 2003
Resolution: This deficiency regarded the engine and battery spaces, whereby the switches were removed instead of repairing.
Communications › Radio Communications
Issued 10 March 2003 Resolved
Insure EPIRB is registered with NOAA LEGACY COMPONENT DESC: EPIRB
Action required: 705 - Other - as specified
Due 10 April 2003
Resolved 1 April 2003
Resolution: Registered with NOAA.
Construction/Loadline › Structures
Issued 10 March 2003 Resolved
Repair cracked vents along port and starboard bulwark, 4 each side. LEGACY COMPONENT DESC: Ventilators
Action required: 705 - Other - as specified
Due 10 April 2003
Resolved 6 May 2003
Resolution: All vents repaired with fibreglass tape.
Documentation › Markings/Placards
Issued 10 March 2003 Resolved
Provide emergency broadcast placard. LEGACY COMPONENT DESC: Emergency broadcast
Action required: 705 - Other - as specified
Due 10 April 2003
Resolved 1 April 2003
Resolution: Provided emergency broadcast placard.
Fire Fighting › Combustible Materials
Issued 10 March 2003 Resolved
Remove propane bottle from pilot house. LEGACY COMPONENT DESC: Propane bottle
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 April 2003
Resolved 1 April 2003
Resolution: Removed propane bottle.
Lifesaving › Hand Flares
Issued 10 March 2003 Resolved
Provide watertight flare box. LEGACY COMPONENT DESC: Storage
Action required: 705 - Other - as specified
Due 10 April 2003
Resolved 1 April 2003
Resolution: Stored in watertight ammo box.
Accommodation/Occupational Safety › Medical/First Aid
Issued 10 March 2003 Resolved
Provide as new First Aid Kit with list, contents, & watertight container IAW 46 CFR 160.041-4 (Still needs watertight container). LEGACY COMPONENT DESC: Medicine Chest
Action required: 705 - Other - as specified
Due 10 April 2003
Resolved 6 May 2003
Electrical › Electrical Distribution System (service)
Issued 10 March 2003 Resolved
Remove, replace, secure or cap exposed power/ground cables located in 1000 Watt power inverter panel. LEGACY COMPONENT DESC: Wiring
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 April 2003
Resolved 6 May 2003
Resolution: Removed inverter.
Electrical › Electrical Distribution System (service)
Issued 10 March 2003 Resolved
Replace or cap 10 dead-end wires in forward space of pilot house. LEGACY COMPONENT DESC: Wiring
Action required: 705 - Other - as specified
Due 10 April 2003
Resolved 1 April 2003
Resolution: Wrapped electrical tape around dead-ends.
Documentation › Certificates/Documents
Issued 10 March 2003 Resolved
Provide original Certificate of Documentation. LEGACY COMPONENT DESC: Certificate of Documentation (CG-1270)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 April 2003
Resolution: Provided original COD.
Engineering › Diesel Engine (propulsion-direct drive)
Issued 10 March 2003 Resolved
Replace as new starboard crankcase vent hose (burned) and prevent contact with exhaust manifold. LEGACY COMPONENT DESC: Crankcase
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 March 2003
Resolved 1 April 2003
Resolution: Replaced hose.
Engineering › Reduction Gearing/Clutches
Issued 10 March 2003 Resolved
Secure port engine transmission cooler. LEGACY COMPONENT DESC: Transmission cooler
Action required: 705 - Other - as specified
Due 10 April 2003
Resolved 1 April 2003
Resolution: Secured transmission cooler.
Electrical › Electrical Distribution System (service)
Issued 10 March 2003 Resolved
Remove or cap dead-end wire (bonding) starboard forward engine space. LEGACY COMPONENT DESC: Wiring
Action required: 705 - Other - as specified
Due 10 April 2003
Resolved 1 April 2003
Resolution: Removed dead-end wire.
Stability › Watertight Integrity
Issued 10 March 2003 Resolved
Remove non-functional discharge hose and plug through hole, starboard aft enging space. LEGACY COMPONENT DESC: Discharge hose
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 April 2003
Resolution: Installed new hose and connected to drain port for engine hatch covers and through hull fitting.
Fire Fighting › Portable Dry Chemical Fire Extinguisher
Issued 10 March 2003 Resolved
Replace as new 2 portable fire extinguisher brackets with CG Approval #'s in passenger lounge which can be secure with straps. LEGACY COMPONENT DESC: Mounting Bracket
Action required: 705 - Other - as specified
Due 10 April 2003
Resolved 1 April 2003
Resolution: Provided brackets.
Electrical › Lighting (service)
Issued 10 March 2003 Resolved
Provide marine grade light switch in engine room/space and battery space. LEGACY COMPONENT DESC: Switch
Action required: 705 - Other - as specified
Due 10 April 2003
Resolved 1 April 2003
Resolution: Removed switch from both spaces.
Electrical › Electric Supply System (service)
Issued 10 March 2003 Resolved
Provide corrosion resistant (i.e. rubber) mat for battery box. LEGACY COMPONENT DESC: Battery Installation
Action required: 705 - Other - as specified
Due 10 April 2003
Resolved 1 April 2003
Resolution: Provided corrosion resistant mat.
Fire Fighting › Ventilation Systems
Issued 10 March 2003 Resolved
Provide vent covers (functional) and prove operation of vent covers. LEGACY COMPONENT DESC: Ducts
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 April 2003
Resolved 1 April 2003
Resolution: Provided operational vent covers.
Fire Fighting › Ventilation Systems
Issued 10 March 2003 Resolved
Have vent covers accessible and properly labeled. LEGACY COMPONENT DESC: Ducts
Action required: 705 - Other - as specified
Due 10 April 2003
Resolved 1 April 2003
Resolution: Vent covers are accessible and labeled.
Pollution Prevention/Response › Prevention Equipment
Issued 10 March 2003 Resolved
Lock and secure valve handles for port and starboard marine sanitation tanks for over board discharge. LEGACY COMPONENT DESC: Marine Sanitation Device, Type III
Action required: 705 - Other - as specified
Due 10 April 2003
Resolved 6 May 2003
Resolution: Witnessed valves in locked position.
Navigation › Piloting/Steering
Issued 10 March 2003 Resolved
Provide updated navigation charts and publications (still need to update navigation chart). LEGACY COMPONENT DESC: Marine Charts
Action required: 705 - Other - as specified
Due 10 April 2003
Resolved 6 May 2003
Engineering › Fuel Oil Service System
Issued 10 March 2003 Resolved
Show valve turn direction for Emergency Fuel Shutoff valves. LEGACY COMPONENT DESC: Valve, Control
Action required: 705 - Other - as specified
Due 10 April 2003
Resolved 1 April 2003
Resolution: Valve turn direction shown.
Stability › Watertight Integrity
Issued 10 March 2003 Resolved
Make weather deck above and forward of collision bulkhead watertight. LEGACY COMPONENT DESC: Collision bulkhead space
Action required: 705 - Other - as specified
Resolved 1 April 2003
Resolution: Weather deck watertight.
Stability › Watertight Integrity
Issued 10 March 2003 Resolved
Make space forward of the collision bulkhead watertight in way of sealing holes on starboard overhead and bulkhead. LEGACY COMPONENT DESC: Collision bulkhead
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 April 2003
Resolution: Sealed holes.
Communications › Radio Communications
Issued 10 March 2003 Resolved
Prove operation of SSB radio. LEGACY COMPONENT DESC: SSB
Action required: 705 - Other - as specified
Due 16 May 2003
Resolved 2 December 2003
Navigation › Collision/Grounding Avoidance
Issued 10 March 2003 Resolved
Prove operation of radar. LEGACY COMPONENT DESC: Radar
Action required: 705 - Other - as specified
Due 10 April 2003
Resolved 6 May 2003
Electrical › Electric Supply System (service)
Issued 10 March 2003 Resolved
Provide cover for electronics fuse box. LEGACY COMPONENT DESC: Overcurrent Device
Action required: 705 - Other - as specified
Due 10 March 2003
Resolved 1 April 2003
Resolution: Provided cover.
Documentation › Logs/Records
Issued 10 March 2003 Resolved
Provide proof of proper Drug & Alcohol Program. LEGACY COMPONENT DESC: Drug Test Records
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 May 2003
Resolution: [withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Operations/Management › FireFighting
Issued 10 March 2003 Resolved
Conduct underway drills in way of firefighting and man-over-board. LEGACY COMPONENT DESC: Underway drills
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 April 2003
Resolved 6 May 2003
Resolution: Drills conducted and discussed, all drills sat.
Engineering › Diesel Engine (propulsion-direct drive)
Issued 10 March 2003 Resolved
Inspect engine room/space and lazerette (steering) with attending inspector (while underway). Also inspect fuel space for fuel oil leakage around fuel tank. LEGACY COMPONENT DESC: Underway Inspection
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 April 2003
Resolved 6 May 2003
Fire Fighting › Combustible Materials
Issued 10 March 2003 Resolved
Provide exhaust lagging for exposed exhaust pipe on starboard engine and port engine. LEGACY COMPONENT DESC: Insulation
Action required: 705 - Other - as specified
Due 1 May 2003
Resolved 6 May 2003
Engineering › Fuel Oil Service System
Issued 10 March 2003 Resolved
Prove that all fuel hoses are A1 hose per 46 CFR 182.40. LEGACY COMPONENT DESC: Hose
Action required: 705 - Other - as specified
Due 1 May 2003
Resolved 6 May 2003
Pollution Prevention/Response › Prevention Equipment
Issued 10 March 2003 Resolved
Replace starboard sewage drain hose. LEGACY COMPONENT DESC: Sewage System Piping
Action required: 705 - Other - as specified
Due 1 May 2003
Resolved 6 May 2003
Resolution: O/O replaced port and starboard sewage drain hoses.
Navigation › Collision/Grounding Avoidance
Issued 10 March 2003 Resolved
Replace forward navigation mast light with marine grade mast. LEGACY COMPONENT DESC: Navigation Lights
Action required: 705 - Other - as specified
Due 1 May 2003
Resolved 6 May 2003
Lifesaving › Lifebuoys
Issued 10 March 2003 Resolved
Replace all batteries in float lights on life buoy and life floats with screw top style. LEGACY COMPONENT DESC: Self-igniting Lights
Action required: 705 - Other - as specified
Due 16 May 2003
Resolved 2 December 2003
Construction/Loadline › Hull
Issued 13 February 2003 Resolved
Crop and renew rot in wood keel forward and aft, prior to operation with passengers, to the satisfaction of the attending marine inspector. Submit repair plans to [phone withheld]. LEGACY COMPONENT DESC: Keel
Action required: 705 - Other - as specified
Resolved 26 February 2003
Resolution: FWD: Cropped out approx 12" section. Installed Insert with scarf/step method, epoxied all joints, seams and anchored to hull with hot galvanized bolts. AFT: Bored out rot 1 1/2inch dia hole approx 3 1/2 inches installed epoxy & maple plug.
Engineering › Shafting/Propeller Arrangements
Issued 13 February 2003 Resolved
Repair as new strut cutlass bearings, port & stbd and strut mounting pads, prior to operation with passengers, to the satisfaction of the attending marine inspector. LEGACY COMPONENT DESC: Strut Bearing
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 26 February 2003
Resolution: Strut mounting pads removed epoxied sealed and remounted. New strut cutlass bearings installed.
Electrical › Electrical Distribution System (service)
Issued 13 February 2003 Resolved
Remove or properly cap off dead end wiring in battery room, prior to operation with passengers, to the satisfaction of the attending marine inspector. 2/26: Amended due date to next COI inspection. LEGACY COMPONENT DESC: Cable
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 6 May 2003
Construction/Loadline › Structures
Issued 13 February 2003 Resolved
Make engine room bulkheads vapor tight, prior to operation with passengers, to the satisfaction of the attending marine inspector. 2/26: Amended due date to next COI inspection. LEGACY COMPONENT DESC: Transverse Bulkhead
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 6 May 2003
Construction/Loadline › Hull
Issued 13 February 2003 Resolved
Pull keel bolt in battery space. Submit proposal if severly wasted. LEGACY COMPONENT DESC: Keel
Action required: 705 - Other - as specified
Resolved 26 February 2003
Resolution: Keel bolt renewed with hot dip galvanized bolt.
Engineering › Shafting/Propeller Arrangements
Issued 13 February 2003 Resolved
Repair as new hose and clamps in shaft cooling line engine room stbd SAE J1942 marine grade, prior to operation with passengers, to the satisfaction of the attending marine inspector. 2/26: Due date changed to next COI inspection. LEGACY COMPONENT DESC: Stern Tube Lubrication/Sealing
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 6 May 2003
Stability › Watertight Integrity
Issued 13 February 2003 Resolved
Make engine room hatches watertight IAW 179.360, prior to operation with passengers, to the satisfaction of the attending marine inspector. 2/26: Due date changed to next COI inspection.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 6 May 2003
Resolution: Tested hatches with garden hose, hatches passed test.
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 5 August 2002 Resolved
Vessel may not carry passengers until exhaust piping is examined by a marine enspector. LEGACY COMPONENT DESC: Piping (exhaust)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 August 2002
Resolution: The upper portion of the port MDE exhaust piping was replaced with new.
Accommodation/Occupational Safety › Occupational Safety
Issued 5 August 2002 Resolved
Repair as new all life rail supports. LEGACY COMPONENT DESC: Deck Rail
Due 10 September 2002
Resolved 10 September 2002
Engineering › Fuel Oil Service System
Issued 23 April 2002 Resolved
Make fuel supply shut off valves operable. LEGACY COMPONENT DESC: Valve, Control
Due 24 May 2002
Resolved 10 June 2002
Resolution: Fuel supply valves are now operational.
Engineering › Fuel Oil Service System
Issued 23 April 2002 Resolved
Install fuel vent flame screens port and stbd side. LEGACY COMPONENT DESC: Vent Pipe
Due 24 May 2002
Resolved 10 June 2002
Resolution: Flame screens installed properly on fuel oil vent pipes.
Engineering › Steering Gear System
Issued 23 April 2002 Resolved
Replace steering arm to tiller yoke bolts with bolts or pins long enough to secure via double nuts/cotter pins or nylon bolts. LEGACY COMPONENT DESC: Pin
Due 24 May 2002
Resolved 10 June 2002
Resolution: Tiller yoke bolts have new nyloc nuts installed.
Stability › Watertight Integrity
Issued 23 April 2002 Resolved
Close openings in engine room bulkhead to maintain vapor tight bulkheads.
Due 24 May 2002
Resolved 10 June 2002
Resolution: Forward engine room bulkhead has been made vapor tight.
Accommodation/Occupational Safety › Occupational Safety
Issued 23 April 2002 Resolved
Repair multiple cracks in railing. LEGACY COMPONENT DESC: Deck Rail
Due 24 May 2002
Resolved 10 June 2002
Resolution: Railing has been repaired to the satisfaction of attending marine inspector.
Stability › Watertight Integrity
Issued 23 April 2002 Resolved
Make engine room hatch watertight.
Due 24 May 2002
Resolved 10 June 2002
Resolution: Engine room hatch has been made watertight.
Engineering › Bilge Water Management System
Issued 23 April 2002 Resolved
Label bilge manifold and install check valves for each suction line. LEGACY COMPONENT DESC: Piping
Due 24 May 2002
Resolved 10 June 2002
Resolution: bilge Bilge piping has been labeled. Check valves to be installed at next drydock.
Accommodation/Occupational Safety › Washroom/Toilet
Issued 23 April 2002 Resolved
Replace water supply valve to heads. LEGACY COMPONENT DESC: Toilet
Action required: 705 - Other - as specified
Due 30 November 2004
Resolved 2 December 2003
Engineering › Bilge Water Management System
Issued 23 April 2002 Resolved
For all PVC bilge piping, install metallic through fittings at watertight bulkheads. LEGACY COMPONENT DESC: Piping
Due 1 December 2002
Resolved 6 May 2003
Deck/Cargo › Marine Portable Tanks › Valve Securing Device
Issued 23 April 2002 Resolved
Replace/Renew missing port and stbd overboard discharge valve securing devices.
Condition: Improper/Lack of Maintenance
Due 23 April 2002
Resolved 23 April 2002
Resolution: Securing devices installed.
Lifesaving › Lifejacket/PFD (Type I) › Lights
Issued 23 April 2002 Resolved
Replace/Renew four missing lifejacket lights.
Condition: Improper/Lack of Maintenance
Due 23 April 2002
Resolved 23 April 2002
Resolution: Replaced four missing lights.
Lifesaving › Buoyant Apparatus
Issued 23 April 2002 Resolved
Replace/Renew one life float paddle, spacers and fix holes in float.
Due 23 April 2002
Resolved 23 April 2002
Resolution: Paddle replaced and spacers replaced and holes filled.
Navigation
Issued 23 April 2002 Resolved
Replace/Renew missing Navigation chart.
Due 23 April 2002
Resolved 23 April 2002
Resolution: Navigation chart replaced.
Navigation › Piloting/Steering
Issued 23 April 2002 Resolved
Replace/Renew missing compass deviation table LEGACY COMPONENT DESC: Compass Deviation Table
Condition: Improper/Lack of Maintenance
Due 23 May 2002
Resolved 10 June 2002
Resolution: New deviation table posted in pilothouse.
Navigation › Piloting/Steering › Magnetic Compass
Issued 23 April 2002 Resolved
Replace/Renew compass illumination light.
Due 23 April 2002
Resolved 23 April 2002
Resolution: Light replaced.
Construction/Loadline › Structures
Issued 23 April 2002 Resolved
Abate furring and rot in way of engine room framing.
Due 23 May 2002
Resolved 10 June 2002
Resolution: Furring of overhaed beams in way of engine room have been repaired to the satisfaction of the attending marine inspector.
Lifesaving
Issued 4 September 2001 Resolved
PRIOR TO CARRYING PASSENGERS, RENEW ALL HANGARS FOR EXHAUST PIPPING.
Condition: Unknown
Due 4 October 2001
Resolved 10 September 2001
Engineering
Issued 4 September 2001 Resolved
PRIOR TO CARRYING PASSENGERS, RENEW AS ORIGINAL ALL DAMAGED (CUT) EXHAUST PIPING, OR CUT OFF DAMAGED PIPE AND EXTEND FLEX COUPLING.
Condition: Unknown
Due 4 October 2001
Resolved 10 September 2001
Engineering
Issued 4 September 2001 Resolved
PRIOR TO CARRYING PASSENGERS, OPTEST BOTH MDE'S AND FIXED FIREFIGHTING ENGINE SHUTDOWN.
Condition: Unknown
Due 4 October 2001
Resolved 10 September 2001
Construction/Loadline
Issued 4 September 2001 Resolved
PRIOR TO CARRYING PASSENGERS, RENEW AFT VERTICAL DECK SUPPORT AS ORIGINAL OR USING STAINLESS STEEL OR ALUMINUM.
Condition: Unknown
Due 4 October 2001
Resolved 10 September 2001
Lifesaving
Issued 4 September 2001 Resolved
PRIOR TO CARRYING PASSENGERS, REPLACE ALL DAMAGED LAGGING, EXCEPT OVER WRINKLE BELLY UNTIL REPAIR IS EXAMINED BY THE MARINE INSPECTOR.
Condition: Unknown
Due 4 October 2001
Resolved 10 September 2001
Construction/Loadline
Issued 4 September 2001 Resolved
PRIOR TO CARRYING PASSENGERS, CLEAN E/R FOR INTERNAL STRUCTURE EXAM, REMOVEOILY WATER.
Condition: Unknown
Due 4 October 2001
Resolved 10 September 2001
Fire Fighting
Issued 4 September 2001 Resolved
PRIOR TO CARRYING PASSENGERS, HAVE E/R FIXED FIREFIGHTING CYLINDER HYDROSTATICALLY TESTED, SERVICED AND RE-WIRED.
Condition: Unknown
Due 4 October 2001
Resolved 10 September 2001
Engineering
Issued 20 March 2001 Resolved
REPLACE OR RENEW BOTH EMERGENCY FUEL CUT-OFF REACH RODS AND FLAME IMPINGEMENT BOWLS.
Condition: Unknown
Due 20 March 2001
Resolved 20 March 2001
Lifesaving
Issued 20 March 2001 Resolved
REPLACE EPIRB HYDROSTATIC RELEASE.
Condition: Unknown
Due 20 March 2001
Resolved 20 March 2001
Lifesaving
Issued 20 March 2001 Resolved
PROVIDE 2 ADULT PFDS FOR 51 TOTAL. (VESSEL IS LIMITED TO 49 TOTAL PERSONS UNTIL THIS ITEM IS SATISFIED)
Condition: Unknown
Due 20 March 2001
Resolved 20 March 2001
Construction/Loadline
Issued 20 March 2001 Resolved
PROVIDE ADDITIONAL HOSE FOR PORTABLE BILGE PUMP [TO ENABLE THE CREW TO DISCHARGE BILGE WATER OVER THE SIDE.]
Condition: Unknown
Due 20 March 2001
Resolved 20 March 2001
Electrical
Issued 20 March 2001 Resolved
REPAIR WIRING CONNECTIONS TO LAMP WIRING IN BATTERY COMPARTMENT.
Condition: Unknown
Due 20 March 2001
Resolved 20 March 2001
Navigation
Issued 20 March 2001 Resolved
PROVE PROPER OPERATION OF RADAR.
Condition: Unknown
Due 20 March 2001
Resolved 20 March 2001
Electrical
Issued 20 March 2001 Resolved
PROPERLY SECURE ALL ELECTRICAL WIRING
Condition: Unknown
Due 20 March 2001
Resolved 20 March 2001
Navigation
Issued 28 February 2000 Resolved
PROVIDE VALID RADIO TELEPHONY CERTIFICATE.
Condition: Unknown
Due 28 February 2000
Resolved 28 February 2000
Unknown
Issued 6 April 1999 Resolved
PROVIDE DRUG TESTING PROGRAM AND RESULTS OF RANDOM DRUG TEST WITHIN THE LAST 12 MONTHS
Condition: Unknown
Due 6 April 1999
Resolved 6 April 1999
Documentation
Issued 6 April 1999 Resolved
PROVIDE CERTIFICATE OF DOCUMENTATION
Condition: Unknown
Due 6 April 1999
Resolved 6 April 1999
Lifesaving
Issued 6 April 1999 Resolved
PROPERLY ATTACH LIFE LINES FOR LIFE FLOATS TO WEAK LINK.
Condition: Unknown
Due 6 April 1999
Resolved 6 April 1999
Fire Fighting
Issued 6 April 1999 Resolved
PROVE PROPER OPERATION OF FIRE PUMP.
Condition: Unknown
Due 6 April 1999
Resolved 6 April 1999
Construction/Loadline
Issued 6 April 1999 Resolved
PROVE PROPER OPERATION OF INSTALLED BILGE PUMP FROM ALL SPACES.
Condition: Unknown
Due 6 April 1999
Resolved 6 April 1999
Lifesaving
Issued 4 March 1998 Resolved
PROVIDE SERVICING REPORT INDICATING SATISFACTORY OPERATION OF EPIRB.
Condition: Unknown
Due 4 March 1998
Resolved 4 March 1998
Lifesaving
Issued 5 March 1997 Resolved
Prior to an Oceans or Coastwise voyage and carriage of passengers, renew the EPIRB battery.
Condition: Unknown
Due 5 March 1997
Resolved 5 March 1997
Construction/Loadline
Issued 13 March 1996 Resolved
REMOVE AND TREAT FURRING ON FORWARD DECK BEAM IN FUEL COMPARTMENT.
Condition: Unknown
Due 13 March 1996
Resolved 13 March 1996
Lifesaving
Issued 13 March 1996 Resolved
PROVIDE 3 PADDLES FOR LIFE FLOATS.
Condition: Unknown
Due 13 March 1996
Resolved 13 March 1996
Construction/Loadline
Issued 6 March 1995 Resolved
TREAT FURRING IN ENGINE ROOM OVERHEAD.
Condition: Unknown
Due 6 March 1995
Resolved 6 March 1995
Lifesaving
Issued 6 March 1995 Resolved
PROCURE 3 LIFEJACKET LIGHTS.
Condition: Unknown
Due 6 March 1995
Resolved 6 March 1995
Lifesaving
Issued 6 March 1995 Resolved
PROCURE JIM BUOY REPAIR KIT AND PATCH HOLES IN 10 PERSON LIFEFLOAT.
Condition: Unknown
Due 6 March 1995
Resolved 6 March 1995
Engineering
Issued 12 May 1994 Resolved
MAKE PERMANENT REPAIR TO WASTED AND HOLED FUEL TANK FILLER NECK ON STARBOARD DIESEL FUEL TANK THAT HAS BEEN TEMPORARILY PATCHED.
Condition: Unknown
Due 12 May 1994
Resolved 12 May 1994
Engineering
Issued 14 March 1994 Resolved
PROVIDE ELECTRICAL BONDING FOR FUEL FILLERS ON PRT & STB TANKS.
Condition: Unknown
Due 14 April 1994
Resolved 12 May 1994
Lifesaving
Issued 14 March 1994 Resolved
RENEW PAINTER ON RING BUOY.
Condition: Unknown
Due 14 April 1994
Resolved 12 May 1994
Lifesaving
Issued 14 March 1994 Resolved
PROVIDE 4 ADDITTIONAL ADULT PFD'S. VSL RESTRICTED TO 47 PERSONS UNTIL PROVIDED.
Condition: Unknown
Due 14 April 1994
Resolved 12 May 1994
Lifesaving
Issued 14 March 1994 Resolved
FOR THE B/A'S: RENEW RING BUOYS, ALL LIFE LINES, ALL GRAB LINES, B/A'S IWOHOLES, PAINTER (FOR THE 15 MAN B/A ONLY) & WEAK LINK.
Condition: Unknown
Due 14 April 1994
Resolved 12 May 1994
Lifesaving
Issued 14 March 1994 Resolved
PROPERLY SECURE 10 MAN B/A PAINTER SPOOL CAN.
Condition: Unknown
Due 14 April 1994
Resolved 12 May 1994
Construction/Loadline
Issued 25 March 1993 Resolved
INSTALL ADAQUATE SECURING DEVICE ON COLLISION BULKHEAD HATCH.
Condition: Unknown
Due 25 March 1993
Resolved 25 March 1993
Construction/Loadline
Issued 25 March 1993 Resolved
CLEAN AND TREAT FURRING IN FUEL TANK COMPARTMENT.
Condition: Unknown
Due 25 March 1993
Resolved 25 March 1993
Engineering
Issued 25 March 1993 Resolved
REPLACE VALVE HANDLE ON STBD EMERGENCY FUEL SHUT-OFF VALVE.
Condition: Unknown
Due 25 March 1993
Resolved 25 March 1993
Lifesaving
Issued 25 March 1992 Resolved
PROVIDE 2 ADULT CG APPROVED TYPE I PFD'S. VSL IS RESTRICTED TO A MAX OF 47PASSENGERS (COASTWISE) UNTIL ITEM CLEARED.
Condition: Unknown
Due 25 March 1992
Resolved 25 March 1992
Construction/Loadline
Issued 25 March 1992 Resolved
PROVIDE WATER TIGHT OR WEATHER TIGHT ENGINE COMPARTMENT HATCH OR PROVE EXEMPTION.
Condition: Unknown
Due 25 March 1992
Resolved 25 March 1992
Construction/Loadline
Issued 25 March 1992 Resolved
REMOVE SPRING HINGES FROM FREEING PORT COVERS.
Condition: Unknown
Due 25 March 1992
Resolved 25 March 1992
Deck/Cargo
Issued 25 March 1992 Resolved
PROVE OPERATION OF ANCHOR LIGHT. VSL IS RESTRICTED TO DAYTIME OPS UNTIL THIS ITEM IS CLEARED.
Condition: Unknown
Due 25 March 1992
Resolved 25 March 1992
Deck/Cargo
Issued 25 March 1992 Resolved
PROVIDE A WATER TIGHT COVER FOR FOREPEAK ACCESS PORT ON MAIN DECK.
Condition: Unknown
Due 25 March 1992
Resolved 25 March 1992
Engineering
Issued 25 March 1992 Resolved
INSTALL 30X30 MESH FLAME SCREENS ON FUEL VENTS.
Condition: Unknown
Due 25 March 1992
Resolved 25 March 1992
Lifesaving
Issued 25 March 1992 Resolved
PROVIDE A RESCUE PLATFORM APPROVED BY [name withheld].
Condition: Unknown
Due 25 March 1992
Resolved 25 March 1992
Navigation
Issued 25 March 1992 Resolved
PROVIDE 8" BELL IAW NAVRULS.
Condition: Unknown
Due 25 March 1992
Resolved 25 March 1992
Lifesaving
Issued 19 March 1991 Resolved
INSTALL RETROREFLECTIVE TAPE ON ALL 3 RING BUOYS.
Condition: Unknown
Due 19 March 1991
Resolved 19 March 1991
Construction/Loadline
Issued 19 March 1991 Resolved
PROVIDE SECURING DEVICE FOR LAZARETTE HATCH. THE VESSEL IS RESTRICTED TO _x001C_ LIMITED COASTWISE OPERATION.
Condition: Unknown
Due 19 March 1991
Resolved 19 March 1991
Lifesaving
Issued 19 March 1991 Resolved
PROVE OPERATION OF EPIRB. THE VESSEL IS RESTRICTED TO LIMITED COASTWISE_x001C_ OPERATION.
Condition: Unknown
Due 19 March 1991
Resolved 19 March 1991
Construction/Loadline
Issued 19 March 1991 Resolved
REPAIR LEAK IN DECK IN WAY OF BAIT TANK DRAIN LINE.
Condition: Unknown
Due 19 March 1991
Resolved 19 March 1991
Construction/Loadline
Issued 28 February 1990 Resolved
SCRAPE AND TREAT FURRING THROUGH HULL BACKING BLOCKS PORT SIDE ENGINE SPACE.
Condition: Unknown
Due 28 February 1990
Resolved 28 February 1990
Construction/Loadline
Issued 28 February 1990 Resolved
EXTEND AFT HATCH COMBING TO 12" ABOVE MAIN DECK.
Condition: Unknown
Due 28 February 1990
Resolved 28 February 1990
Construction/Loadline
Issued 28 February 1990 Resolved
REPAIR AFT HATCH COVER.
Condition: Unknown
Due 28 February 1990
Resolved 28 February 1990
Construction/Loadline
Issued 28 February 1990 Resolved
MAKE PORT MIDSHIPS HATCH WATERTIGHT.
Condition: Unknown
Due 28 February 1990
Resolved 28 February 1990
Construction/Loadline
Issued 3 April 1989 Resolved
REMOVE FURRING WOOD AND TREAT TRANSVERSE DECK FRAME AFT OF FUEL SPACE HATCH PORT SIDE.
Condition: Unknown
Due 3 April 1989
Resolved 3 April 1989
Electrical
Issued 3 April 1989 Resolved
REMOVE OR PROPERLY WIRE BAIT PUMP IN LAZARETTE. DRAWINGS FOR PROPOSED WIRING SHOULD BE SUBMITTED TO THE INSPECTION DEPARTMENT, MSO SFB FOR APPROVAL.
Condition: Unknown
Due 3 April 1989
Resolved 3 April 1989
Electrical
Issued 3 April 1989 Resolved
REPLACE LIGHTING FIXTURE IN BATTERY SPACE WITH A U/L APPROVED OR EQUIVEL- ENT MARINE TYPE LIGHTING FIXTURE.
Condition: Unknown
Due 3 April 1989
Resolved 3 April 1989
Engineering
Issued 21 June 1988 Resolved
PROVIDE ISOLATION VALVES FOR KEEL COOLERS PORT AND STBD.
Condition: Unknown
Due 21 June 1988
Resolved 21 June 1988
Engineering
Issued 21 June 1988 Resolved
RESECURE EXHAUST PIPING ON BOTH MAIN ENGINES.
Condition: Unknown
Due 21 June 1988
Resolved 21 June 1988
Construction/Loadline
Issued 21 June 1988 Resolved
RENEW AS ORIGINAL DRY ROTTED ENGINE COMPARTMENT COMBING PORT, STBD AND AFT, DECK SUPPORT FRAMES 3 PORT 4,5 & 6 PORT AND STBD FROM FWD ENGINEROOM BULKHEAD, AND E.R. HATCH FRAMING.
Condition: Unknown
Due 21 June 1988
Resolved 21 June 1988
Accommodation/Occupational Safety
Issued 21 June 1988 Resolved
RENEW WASTED RAIL SUPPORT AT BOW AND #4 SUPPORT PORT.
Condition: Unknown
Due 21 June 1988
Resolved 21 June 1988
Engineering
Issued 23 March 1988 Resolved
INSTALL SHEILDING DEVICES FOR REMOTE FUEL SHUT-OFF OF FUEL.
Condition: Unknown
Due 23 March 1988
Resolved 23 March 1988
Engineering
Issued 23 March 1988 Resolved
FUEL SCREENS ON FUEL TANK VENTS WERE EXCESSIVELY CORRODED.
Condition: Unknown
Due 23 March 1988
Resolved 23 March 1988
Engineering
Issued 23 March 1988 Resolved
LOOSE MOTOR MOUNTS ON STARBOARD ENGINE.
Condition: Unknown
Due 23 March 1988
Resolved 23 March 1988
Navigation
Issued 22 April 1987 Resolved
REPLACE LUBRICATION FITTINGS ON STEERING SYSTEM (2).
Condition: Unknown
Due 22 April 1987
Resolved 22 April 1987
Fire Fighting
Issued 22 April 1987 Resolved
REPAIR, OR REPLACE PORTABLE FIRE PUMP.
Condition: Unknown
Due 22 April 1987
Resolved 22 April 1987
Accommodation/Occupational Safety
Issued 28 May 1986 Resolved
PROVIDE LOCKING MECHANISM FOR MSD OVERBOARD DISCHARGE VALVES.
Condition: Unknown
Due 28 May 1986
Resolved 28 May 1986
Lifesaving
Issued 28 May 1986 Resolved
PROVIDE (2) ADULT PFD'S FOR A TOTAL NUMBER OF (52). VESSEL RESTRICTED TO CARRYING (50) PERSONS TOTAL, UNTIL CORRECTED.
Condition: Unknown
Due 28 May 1986
Resolved 28 May 1986

Casualty record · 4

3 September 2001Routine · role: Involved in a Marine Casualty · activity 1707828
21 August 2002Routine · role: Involved in a Marine Casualty · activity 1664306
22 January 2005Routine · role: Involved in a Marine Casualty · activity 2286776
21 August 2007Routine · role: Involved in a Marine Casualty · activity 3036411
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.