MAURY USCG vessel records Sign in
← All vessels

H.S. TIGER-TAIL

H.S. TIGER-TAIL is a 1966 passenger vessel (inspected). The Coast Guard has recorded 26 inspections since 1985, most recently in July 2002, along with 29 deficiencies.

Records from 1985 to 2002. Most recent: inspection, 15 July 2002.

Built
1966
Last inspected
15 July 2002
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

Flag
UNITED STATES
—
Maury page id
psix-45514

Inspections, by type

…with no type recorded1
Years with a record 14 calendar years (1985–2002)
The 26 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 24 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it26 - Regulatory (Subpart C or D), Net Ton
27 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WAL2102MMSI not assigned · expired · compulsorily equipped · granted 15 May 1995, cancelled 2 July 2005
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 26

15 July 2002 Administrative Inspection
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1643578
25 July 1997 Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 779762
25 March 1997 Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1108786
15 July 1996 Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1092074
12 September 1995 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1191162
29 June 1995 COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1185398
21 July 1994 Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 864432
15 December 1993 Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1160421
22 July 1993 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 844383
2 June 1993 Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1142419
11 December 1992 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1132755
1 July 1992 COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 947284
24 May 1991 Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1241715
18 December 1990 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1219409
25 October 1990 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 917849
18 October 1990 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 899913
9 August 1990 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1229661
6 June 1990 COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 900386
1 August 1989 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1039384
19 June 1989 Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1209435
13 March 1989 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1203050
7 December 1988 Re-Inspection · Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1035080
7 December 1987 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1309518
25 June 1987 COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1323644
2 July 1986 Re-Inspection · Credit Drydock
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1306557
22 July 1985 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 983609

Deficiency record · 29

Electrical
Issued 29 June 1995 Resolved
Fuse power leads close to batteries that supply breaker and switches at steering consol.
Condition: Unknown
Due 29 June 1995
Resolved 29 June 1995
Electrical
Issued 29 June 1995 Resolved
Replace bilge pump wiring with approved wire.
Condition: Unknown
Due 29 June 1995
Resolved 29 June 1995
Electrical
Issued 29 June 1995 Resolved
Replace red wire to port engine tilt/trim relay.
Condition: Unknown
Due 29 June 1995
Resolved 29 June 1995
Lifesaving
Issued 21 July 1994 Resolved
Replace battery in waterlight.
Condition: Unknown
Due 22 July 1994
Resolved 22 July 1994
Navigation
Issued 21 July 1994 Resolved
Repair anchor light.
Condition: Unknown
Due 22 July 1994
Resolved 22 July 1994
Engineering
Issued 21 July 1994 Resolved
Replace cracked fuel hose.
Condition: Unknown
Due 22 July 1994
Resolved 22 July 1994
Construction/Loadline
Issued 2 June 1993 Resolved
Restencil vessels name on bow.
Condition: Unknown
Due 2 June 1993
Resolved 2 June 1993
Electrical
Issued 2 June 1993 Resolved
Provide covers for interior over head lights.
Condition: Unknown
Due 2 June 1993
Resolved 2 June 1993
Accommodation/Occupational Safety
Issued 2 June 1993 Resolved
Secure aft starboard deck plate.
Condition: Unknown
Due 2 June 1993
Resolved 2 June 1993
Lifesaving
Issued 1 July 1992 Resolved
Renew reflective tape on child pfd's.
Condition: Unknown
Due 1 July 1992
Resolved 1 July 1992
Engineering
Issued 1 July 1992 Resolved
Label emergency fuel shut-off.
Condition: Unknown
Due 1 July 1992
Resolved 1 July 1992
Fire Fighting
Issued 1 July 1992 Resolved
Provide suitable bracket for fire extinguisher.
Condition: Unknown
Due 1 July 1992
Resolved 1 July 1992
Navigation
Issued 6 June 1990 Resolved
RENEW STEERING CONNECTION ROD BETWEEN OUTBOARD ENGINES.
Condition: Unknown
Due 6 June 1990
Resolved 6 June 1990
Fire Fighting
Issued 6 June 1990 Resolved
PROVIDE MARINE BRACKETS FOR BOTH PORTABLE FIRE EXTINGUISHERS.
Condition: Unknown
Due 6 June 1990
Resolved 6 June 1990
Engineering
Issued 6 June 1990 Resolved
STENCIL VESSEL NAME AND HOME PORT ON VESSEL'S STERN.
Condition: Unknown
Due 6 June 1990
Resolved 6 June 1990
Engineering
Issued 6 June 1990 Resolved
DOUBLE CLAMP ALL FUEL HOSES.
Condition: Unknown
Due 6 June 1990
Resolved 6 June 1990
Lifesaving
Issued 6 June 1990 Resolved
REMOVE NAME OF OTHER VESSEL (GATOR) FROM ALL PFD'S
Condition: Unknown
Due 6 June 1990
Resolved 6 June 1990
Engineering
Issued 6 June 1990 Resolved
RELOCATE INDEPENDENT FUEL TANK TO A LOCATION OUTSIDE THE PASSENGERS CABIN.
Condition: Unknown
Due 6 June 1990
Resolved 6 June 1990
Engineering
Issued 6 June 1990 Resolved
REMOVE OR GAS FREE AND PERMANANTLY DISCONNECT THE FIXED FUEL TANK OR INSTALL FIXED CO2 SYSYTEM WHICH MEETS THE REQUIREMENTS OF 46 CFR 181.20 ANDVENTILATION SYSTEM WHICH MEETS 46 CFR 182.15-45.
Condition: Unknown
Due 6 June 1990
Resolved 6 June 1990
Documentation
Issued 19 June 1989 Resolved
PROVIDE EVIDENCE OF DOCUMENTATION CERTIFICATE.
Condition: Unknown
Due 19 June 1989
Resolved 19 June 1989
Fire Fighting
Issued 19 June 1989 Resolved
INSTALL BRACKET FOR PORTABLE FIRE EXTINGUISHER.
Condition: Unknown
Due 19 June 1989
Resolved 19 June 1989
Documentation
Issued 19 June 1989 Resolved
POST EMERGENCY CHECK-OFF LIST.
Condition: Unknown
Due 19 June 1989
Resolved 19 June 1989
Engineering
Issued 7 December 1988 Resolved
RENEW FUEL HOSE FROM FILTER TO OUTBOARDS WITH USCG TYPE A1
Condition: Unknown
Due 7 December 1988
Resolved 7 December 1988
Engineering
Issued 25 June 1987 Resolved
RUN COPPER FUEL LINE TO FUEL FILTER.
Condition: Unknown
Due 25 June 1987
Resolved 25 June 1987
Engineering
Issued 25 June 1987 Resolved
PROPERLY GROUND PORT FUEL FILL CONNECTION.
Condition: Unknown
Due 25 June 1987
Resolved 25 June 1987
Deck/Cargo
Issued 25 June 1987 Resolved
INSTALL AND MOUNT NEW SWITCH FOR BILGE PUMP
Condition: Unknown
Due 25 June 1987
Resolved 25 June 1987
Engineering
Issued 25 June 1987 Resolved
RELOCATE FUEL FILTER FOR PORT ENGINE TO INSIDE MACHINERY BOY.
Condition: Unknown
Due 25 June 1987
Resolved 25 June 1987
Lifesaving
Issued 22 July 1985 Resolved
MISSING OR DEFECTIVE RETRO-REFLECTIVE TAPE ON LIFE JACKETS.
Condition: Unknown
Due 22 July 1985
Resolved 22 July 1985
Navigation
Issued 22 July 1985 Resolved
RUNNING LIGHT SCREENS
Condition: Unknown
Due 22 July 1985
Resolved 22 July 1985

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.