MAURY USCG vessel records Sign in
← All vessels

TOYTOY

TOYTOY is a 1997 passenger vessel (inspected). The Coast Guard has recorded 32 inspections since 1997, most recently in March 2026, along with 20 deficiencies.

Records from 1997 to 2026. Most recent: inspection, 11 March 2026.

Built
1997
Last inspected
11 March 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

455166
Flag
UNITED STATES
—
Maury page id
psix-455166

Inspections, by type

Years with a record 27 calendar years (1997–2026)
The 32 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)40.0 ft × 15.0 ft × 4.5 ft
Registered tonnagegross 18 / net 14
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderBENTZ BOATS · LEWISTON, ID, UNITED STATES · built 1997
Hull materialAluminum
PropulsionJet Drive
Hull shapeShip
Hull configurationMonohull
Hailing portLEWISTON, ID
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 19 February 2026 · expires 31 March 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it18 - Simplified, Gross Ton
14 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 32

11 March 2026 Deficiency Check · COI Inspection · Hull Examination
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8320152
27 March 2025 Annual Inspection · DAPI Audit · Deficiency Check
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8102701
21 March 2024 Annual Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7890103
30 March 2023 Annual Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7686176
15 March 2022 Annual Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7624591
4 February 2021 Hull Examination · COI Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7142366
17 March 2020 Annual Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6926282
20 March 2019 Annual Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6643435
6 March 2018 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6362030
8 March 2017 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6098578
8 March 2016 Annual Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 5825800
8 March 2016 Plan Review "T" Boat · COI Inspection · Hull Examination
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 5851541
28 March 2014 Administrative Inspection
Administrative · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 4824919
4 March 2014 Annual Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 4804962
3 February 2012 Administrative Inspection
Administrative · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 4237934
16 March 2010 Annual Inspection
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3682406
17 March 2009 Annual Inspection
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3428718
16 April 2008 DAPI Audit
Administrative · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3185824
11 March 2008 Annual Inspection
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3167159
26 March 2007 COI Inspection · Deficiency Check · Hull Examination
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2883483
23 May 2006 Deficiency Check
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2692482
16 March 2006 Annual Inspection
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2599751
31 March 2005 Annual Inspection · Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2290383
31 March 2004 Annual Inspection · Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2020847
26 March 2003 Deficiency Check · Annual Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1756322
27 March 2002 COI Inspection · Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1494154
19 March 2001 Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1470012
21 March 2000 COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 816687
9 April 1999 Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 786985
26 March 1999 Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 780975
16 March 1998 Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 787379
14 May 1997 Plan Review "T" Boat · Hull Examination · Initial Certification · Deficiency Check · Initial Construction-Excluding Oversight
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 781850

Deficiency record · 20

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 27 March 2025 Resolved
46 CFR 182.520(a):...Individual power pumps used for separate spaces are to be controlled from a central control point and must have a light or other visual means at the control point to indicate operation. MI identified broken indicating light for automatic bilge pump. Owner directed to replace the light, which owner replaced while the rest of the inspection was conducted.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 April 2025
Resolved 21 April 2025
Resolution: Electrician fixed wiring to show when pump is operating.
Engineering › Fuel Oil Service System › Filter
Issued 6 March 2018 Resolved
Install fuel drip pan/trays under fuel filters/strainers; provide tight-fitting flame screens to both drip pans/trays.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 6 April 2018
Resolved 2 April 2018
Resolution: Vessel's owner installed new drip pans/trays w/ flame screens under both fuel filters/strainers.
Operations/Management › Pollution › Control of Discharge of Oil
Issued 8 March 2017 Resolved
No oil pollution prevention placard onboard the vessel. Post an oil pollution prevention placard in accordance with 33CFR155.450 to the satisfaction of the attending marine inspector.
Condition: Improper/Lack of Maintenance
Due 7 April 2017
Resolved 25 March 2017
Resolution: Received email from vessel representative [name withheld] stating an oil pollution placard had been placed on vessel TOY TOY. This statement was accompanied with a picture.
Communications › Alarms/Indicators › Bilge Alarm
Issued 26 March 2007 Resolved
Provide and install visual indication of the Bilge High Level Alarm IAW 46 CFR 182.530.
Action required: 705 - Other - as specified
Due 26 April 2007
Resolved 26 March 2007
Construction/Loadline › Hull › Weld
Issued 16 March 2006 Resolved
Vee and Weld cracked welds IWO emergency exits.
Due 30 March 2006
Resolved 23 May 2006
Resolution: Received letter dated 23 May 06 stating racks were vee and welded from vessel rep.
Lifesaving › Lifebuoys › Serviceable
Issued 31 March 2005 Resolved
Replace ring buoy with approved type. 46 CFR 180.70(a)(2), prior to carrying passenger.
Condition: Unknown
Due 1 May 2005
Resolved 17 May 2005
Resolution: Replaced ring buoy and stenciled with name
Lifesaving › Visual Distress Signals (General) › Not on Board
Issued 31 March 2005 Resolved
Provide floating waterlight prior to operating with passengers at night. 46 CFR 180.70(d)
Due 1 May 2005
Resolved 17 May 2005
Resolution: Completed
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 31 March 2005 Resolved
Provide two portable lights 46 CFR 183.430
Due 1 May 2005
Resolved 17 May 2005
Resolution: Corrected
Lifesaving › Lifebuoys
Issued 31 March 2004 Resolved
Provide three (3) foot lanyard for life buoy light. LEGACY COMPONENT DESC: Self-igniting Lights
Due 1 May 2004
Resolved 6 May 2004
Engineering › Gasoline Engine (propulsion)
Issued 31 March 2004 Resolved
Clean flame screens installed in drip pans.
Due 1 May 2004
Resolved 6 May 2004
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 31 March 2004 Resolved
Ensure Fireboy can shutdown ventilation and engine, prior to carrying passengers.
Due 1 May 2004
Resolved 6 May 2004
Engineering › Gasoline Engine (auxiliary)
Issued 26 March 2003 Resolved
Replace the O-Ring on the port engine jet pump shift tube. Current O-Ring is leaking water into the engine compartment. 46 CFR 176.800
Condition: Improper/Lack of Maintenance
Due 26 April 2003
Resolved 9 May 2003
Engineering › Fuel Oil Service System
Issued 26 March 2003 Resolved
Replace or clean all fuel drip-pan flame screens. 46 CFR 182.455 LEGACY COMPONENT DESC: Fuel Filter Drip Pans
Condition: Improper/Lack of Maintenance
Due 26 April 2003
Resolved 9 May 2003
Fire Fighting › Fixed Gas Fire Extinguishing System
Issued 26 March 2003 Resolved
Rewire/repair the fixed (FIREBOY) firefighting system, so when the bottle discharges the engines and ventilation blowers shut down. 46 CFR 181.420 LEGACY COMPONENT DESC: Engine & Ventilation Shutdowns
Condition: Improper Installation
Due 26 April 2003
Resolved 9 May 2003
Engineering › Fuel Oil Service System
Issued 26 March 2003 Resolved
Replace all fuel hoses over 30" in length with SAE J-1942 hose or install fire sleeves over current hoses IAW manufactures installation instructions. 46 CFR 182.720 LEGACY COMPONENT DESC: Hose
Condition: Improper Installation
Due 26 April 2003
Resolved 9 May 2003
Construction/Loadline › Hull › Longitudinal Frame
Issued 27 March 2002 Resolved
Make/provide repair proposal for stress fractures and cracks to the side-shell brackets, welds, and transverse frames, on both port and stbd sides of the vessel. After proposal is submitted, wait for approval before making repairs. Repairs to be completed prior to 27Apr02. 46 CFR 176.700
Condition: Damaged By Earlier Event
Due 27 April 2002
Resolved 5 April 2002
Fire Fighting
Issued 19 March 2001 Resolved
PROVIDE AUDIBLE ALARM FOR FIXED FIRE FIGHTING SYSTEM AS REQUIRED BY 46 CFR 181.420(b)2
Condition: Unknown
Due 19 April 2001
Resolved 19 April 2001
Lifesaving
Issued 19 March 2001 Resolved
PROVIDE RETRO TAPE ON RING BUOY 46 CFR 160.050
Condition: Unknown
Due 19 April 2001
Resolved 19 April 2001
Unknown
Issued 26 March 1999 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 26 March 1999
Resolved 26 March 1999
Documentation
Issued 14 May 1997 Resolved
POST ORIGINAL CERTIFICATE OF DOCUMENTATION ON BOARD UPON RECEIPT. FAX COPYOF DOCUMENT TO THIS OFFICE.
Condition: Unknown
Due 25 July 1997
Resolved 25 July 1997

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.