MAURY USCG vessel records
← All vessels

CALUSA STAR

CALUSA STAR is a 1997 passenger vessel (inspected). The Coast Guard has recorded 13 inspections since 2016, most recently in June 2026, along with 12 deficiencies — 2 with no resolution recorded —.

Records from 2016 to 2026. Most recent: inspection, 1 June 2026.

Built
1997
Last inspected
1 June 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Everything above is free. The detail below — the inspection history, the deficiency record and the documentation record — is Professional, $39 a month. Sign in.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 1 June 2026
…past their stated due date1
Operational controls None recorded without a removal date
Years with a record 8 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDL3649
455176
Flag
UNITED STATES
Maury page id
psix-455176

Documentation record

Tonnage as PSIX records it4 - Regulatory (Subpart C or D), Gross Ton
4 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
Detail on this page

13 inspections, each with its date, unit and type; 12 deficiencies with the resolution recorded against each; the documentation record, as PSIX holds it. The counts in the summary above are the same counts, and they are free.

$39 a month or $299 a year, every vessel page, cancel any time. Founding rate $19.99 a month for life, for the first 200 subscribers. Plans Sign in

Maury does not score, rate or grade vessels, at any price.

Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 13

1 June 2026 Administrative Inspection
Administrative · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 8385521
25 October 2022 Damage Survey
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7587941
26 August 2021 Administrative Inspection · In-Service Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7295957
1 March 2021 Administrative Inspection · DAPI Audit · COI Inspection · Deficiency Check
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7146009
2 June 2020 Administrative Inspection · Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6974642
19 November 2019 Administrative Inspection
Administrative · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6858603
1 August 2019 Drydock Exam · Internal Structural Exam · Administrative Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6767054
1 May 2019 Annual Inspection · Administrative Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6673170
23 May 2018 Annual Inspection · Administrative Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6421511
2 March 2018 Administrative Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6366147
27 February 2017 Annual Inspection · Administrative Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6095574
2 March 2016 Administrative Inspection
Administrative · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 5820088
7 January 2016 In-Service Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 5792926

Deficiency record · 12

02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 2 November 2022 No resolution recorded
Vessel was identified as having potential damage from Hurricane IAN. Prior to conducting repairs, contact the local USCG Marine Inspections office and submit a repair proposal for approval. Vessel is not permitted to return to commercial service until cleared by a USCG Marine Inspector.
Condition: Damaged By Earlier Event
Action required: 60 - Rectify deficiencies prior to movement
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 10 September 2021 No resolution recorded
Vessel was due for a scheduled dry dock NLT 31AUG2021. Vessel was not ready for inspection and did not receive a credit dry dock before that date. Prior to carrying passengers, complete a credit dry dock to the satisfaction of a Marine Inspector. 46 CFR 176.600(c)(2)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 September 2021 — due date passed with no resolution recorded
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Radio (including exemption)
Issued 1 March 2021 Resolved
Renew FCC Safety Radio Certificate. Vessel is restricted to 1,000 feet from shore until rectified.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 March 2021
Resolved 16 March 2021
Resolution: Received copy of FCC Safety Radio Certificate. Updated certificate in MISLE details.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 1 March 2021 Resolved
Install a drip pan or install steel filter cap under the gasoline fuel filter in the fuel supply line for propulsion engines.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 March 2021
Resolved 16 March 2021
Resolution: Received photo of newly installed fuel filters.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 1 March 2021 Resolved
Provide 06 flares that meet the appropriate Subchapter Q specs IAW 46 CFR 180 for a Lakes, Bays, and Sounds route.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 March 2021
Resolved 16 March 2021
Resolution: Received photo of new red hand flares onboard.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 2 March 2018 Resolved
Vessel has gone past hull exam due date on its COI, do not carry passengers until a satisfactory hull exam has been completed. (46CFr176.800)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 March 2018
Resolution: Completed hull exam.
Construction/Loadline › Markings › Vessel Name/Home Port
Issued 2 March 2016 Resolved
VESSEL DOES NOT HAVE THE NAME POSTED ON PORT AND STARBOARD BOW. POST NAME ON THE PORT AND STARBOARD BOW. 46 CFR 67.123(c)
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 1 April 2016
Resolution: O/O POSTED NAME ON BOTH PORT AND STARBOARD BOWS. SAT
Construction/Loadline › Hull › Hull Plating
Issued 25 January 2016 Resolved
VESSELS MAIN DECK WOOD IS ANGEL HAIRING UNDERNEATH APPROXIMATELY HALF WAY BACK GOING ALL THE WAY FORWARD. REMOVE ANGEL HAIRING AND COAT WITH SOME TYPE OF PRESERVATIVE 46 CFR 176.600
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 18 February 2016
Resolution: VESSEL REMOVED ANGEL HAIRING AND APPLIED PRESERVATIVE TO AFFECTED AREA. SAT
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 25 January 2016 Resolved
LIFE JACKET COMPARTMENTS ARE NOT LABELED. LABEL ALL LIFE JACKET COMPARTMENTS. 46 CFR 180.78
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 2 March 2016
Resolution: O/O LABELED ALL LIFE JACKET COMPARTMENTS. SAT
Lifesaving › Lifejacket/PFD (Type I) › Marking
Issued 25 January 2016 Resolved
LIFE JACKETS ARE NOT LABELED PROPERLY. LABEL ALL LIFE JACKETS PROPERSLY 46 CFR 180.71
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 2 March 2016
Resolution: O/O LABELED ALL LIFE JACKETS PROPERLY. SAT
Engineering › Engine Controls (Electric/Electronic) › Linkage
Issued 25 January 2016 Resolved
WHILE U/W VESSELS ENGINE TRIMMED UP AUTOMATICALLY WITHOUT BEING ENGAGED. IDENTIFY PROBLEM WITH STARBOARD ENGINE TRIM/TILT MOTOR. REPAIR OR REPLACE MOTOR AND CONTROLS. 46 CFR 182.200
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 2 March 2016
Resolution: O/O REPLACED THROTTLE CONTROLS WITH NEW. CONDUCTED TEST, SAT
Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 25 January 2016 Resolved
VESSEL WAS MISSING ONE FLASHLIGHT. PROVIDE ADDITIONAL FLASHLIGHT 46 CFR 183.430
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 2 March 2016
Resolution: O/O PROVIDED ADDITIONAL FLASHLIGHT.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.