MAURY USCG vessel records Sign in
← All vessels

THE UNCLE OSCAR

THE UNCLE OSCAR is a 1996 passenger vessel (inspected). The Coast Guard has recorded 37 inspections since 1997, most recently in March 2026, along with 41 deficiencies.

Records from 1997 to 2026. Most recent: inspection, 16 March 2026.

Built
1996
Last inspected
16 March 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WCX5004
455189
Flag
UNITED STATES
367172510, 368011610
Maury page id
psix-455189

Inspections, by type

Years with a record 24 calendar years (1997–2026)
The 37 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)56.0 ft × 16.0 ft × 7.5 ft
Registered tonnagegross 45 / net 36
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderBEAVER SHIP WORKS CORP · ARUNDEL, ME, UNITED STATES · built 1996
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portRYE, NH
Trade endorsementsCoastwise, unrestricted, Fishery
DocumentationValid · issued 13 August 2026 · expires 30 September 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it45 - Simplified, Gross Ton
36 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDJ7944MMSI 368011610 · active · compulsorily equipped · granted 1 November 2017, expires 1 November 2027
WCX5004MMSI 367172510 · active · compulsorily equipped · granted 30 March 2017, expires 22 May 2027 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 37

16 March 2026 Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8327284
15 December 2025 Administrative Inspection · Hull Examination · Internal Structural Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8283414
30 September 2025 Annual Inspection
Physical examination · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 8244138
25 September 2024 Annual Inspection
Physical examination · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 8008976
17 November 2023 Hull Examination · Internal Structural Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7824487
18 September 2023 Annual Inspection
Physical examination · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 7793587
30 September 2022 Annual Inspection
Physical examination · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 7568741
10 November 2021 Plan Review "T" Boat · Drydock Exam · Deficiency Check · Internal Structural Exam · Administrative Inspection · Construction Oversight · In-Service Inspection
Physical examination · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 7356657
16 September 2021 COI Inspection
Physical examination · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 7294496
1 June 2020 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 7279029
17 December 2019 Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 6875635
31 May 2019 Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 6699224
28 November 2017 Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 6313883
28 November 2017 Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6314100
31 October 2017 Deficiency Check · Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 6298242
24 October 2016 COI Inspection · Administrative Inspection · DAPI Audit
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6028714
21 April 2016 Drydock Exam · Internal Structural Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 5859598
5 August 2011 Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 4145807
2 November 2010 Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3885109
1 December 2008 Annual Inspection · DAPI Audit
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3371760
6 December 2007 Annual Inspection · Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3111184
6 April 2006 Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2618780
1 December 2005 Periodic Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2546647
18 November 2004 Periodic Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2243853
19 April 2004 Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2047827
20 November 2003 Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1951636
30 April 2003 Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1783653
9 December 2002 Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1716533
19 November 2001 COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1437985
16 April 2001 Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1397623
14 April 2000 Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1421853
20 December 1999 Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1406614
15 April 1999 Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 795278
16 November 1998 COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 805822
4 May 1998 Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1123927
13 April 1998 Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1124201
30 April 1997 Initial Certification · Plan Review "T" Boat · Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1460133

Deficiency record · 41

01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 23 December 2025 Resolved
A vessel that is exposed to salt water more than three months in any 12 month period since the last examination must undergo a drydock examination and an internal structural at least once every two years. Vessel did not complete a drydock or internal structure examination within 24 months of the previous exam. Complete credit hull inspection prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 March 2026
Resolution: Operator was issued credit hull inspection.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 17 November 2022 Resolved
Rails or equivalent protection must be installed near the periphery of all decks of a vessel accessible to passengers or crew. Rails on passenger decks of a ferry or vessel engaged in excursion trips including but not limited to sightseeing trips, dinner and party cruises, and overnight cruises, must be at least 1,000 millimeters (39.5 inches) high. Rail courses or the equivalent must be installed between a top rail and the deck so that no open space exists that is more than 305 millimeters (12 inches) high except: (1) On passenger decks of a ferry or of a vessel on an excursion trip the following must be installed: (i) Bulwarks; (ii) Chain link fencing or wire mesh that has openings of not more than 4 inches in diameter; or (iii) Bars, slats, rail courses, or an equivalent spaced at intervals of not more than 100 millimeters (4 inches). Vessel was previously engaged in head boat/fishing service and now is engaged in excursion service. Vessel is fitted with 36 inch rails.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 20 September 2023
Resolution: Rails have been modified to meet minimum height requirements.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 17 November 2022 Resolved
The Certificate of Inspection and any SOLAS Certificates must be posted under glass or other suitable transparent material, such that all pages are visible, in a conspicuous place on the vessel where observation by passengers is likely. Vessel COI is not posted.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 7 December 2022
Resolution: COI posted with all pages visible in place likely to be observed by passengers.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 17 November 2022 Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date: Charts of large enough scale to make safe navigation possible. Vessel has electronic charts and was unable to demonstrate latest update/correction.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 7 December 2022
Resolution: Vessel master demonstrated use of smart phone application that allows wireless chart updates to plotter.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 16 September 2021 Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspections of machinery, fuel, and piping systems. On THE UNCLE OSCAR, the Main Diesel Engine (MDE)is currently inoperable due to a blown piston. Owner/operator shall repair and/or renew MDE such that vessel is restored to full operational capability and make available for all necessary tests and inspections required by attending MI, including tests of related systems and appurtenances. Proper CG oversight is required on any repairs/re-powering projects, and owner/operator shall ensure CG approval prior to initiating.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 June 2022
Operations/Management › Drills/Instruction › Not Conducted
Issued 2 November 2017 Resolved
Conduct drills
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 May 2018
Fire Fighting › Fixed Gas Fire Extinguishing System › Tanks
Issued 2 November 2017 Resolved
Tank out of hydrostatic test date requirement.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 May 2018
Lifesaving › Lifefloat › Markings
Issued 31 October 2017 Resolved
Label life floats with new vessel name.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 May 2018
Resolved 21 May 2018
Lifesaving › Lifefloat › Float Free
Issued 31 October 2017 Resolved
Mount new life float in float free arrangement
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 May 2018
Resolved 21 May 2018
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 31 October 2017 Resolved
Provide new/mounted water lights for life floats
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 May 2018
Resolved 21 May 2018
Fire Fighting › Remote Fuel Shutoff › General
Issued 31 October 2017 Resolved
Label remote fuel off location.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 May 2018
Resolved 21 May 2018
Lifesaving › Lifefloat › Paddle
Issued 31 October 2017 Resolved
Provide paddles
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 May 2018
Resolved 21 May 2018
Engineering › Sea-water System (primary cooling) › Piping
Issued 6 December 2007 Resolved
Repair/replace MDE heat exchanger flange piece. Component has wasted through due to galvanic action and leaks excessive amounts of seawater to the bilge.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 April 2008
Resolution: Vessel owner repaired heat exchanger to satisfaction of marine inspector. All leakage has been repaired and conducted operational test satisfactory.
Operations/Management › Drug and Alcohol Testing › Testing, Serious Marine Incident
Issued 6 December 2007 Resolved
Provide proof of 2 hour alcohol testing procedures in the event of a SMI or purchase alco testing kits.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 April 2008
Resolution: Vessel owner placed 02 alcohol test kits on-board vessel
Lifesaving › Lifefloat › Float-free Link
Issued 6 December 2007 Resolved
Purchase and install a new CG approved weak link for lifefloat to comply with 46CFR 180.130(a)(1).
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 April 2008
Resolution: Vessel owner placed CG approved weak link on life float
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 1 December 2005 Resolved
Replace First Aid kit with USCG approved kit or re-supply iaw 46 CFR 160.041.
Action required: 705 - Other - as specified
Due 15 December 2005
Resolved 9 January 2006
Lifesaving › Buoyant Apparatus
Issued 20 November 2003 Resolved
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 February 2004
Lifesaving › Buoyant Apparatus
Issued 20 November 2003 Resolved
Lable paddles for Bouyant apparatus
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 February 2004
Lifesaving › Buoyant Apparatus
Issued 20 November 2003 Resolved
Repair damaged area on bouyant apparatus
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 February 2004
Lifesaving › Buoyant Apparatus
Issued 20 November 2003 Resolved
Provide longer line for the 2nd apparatus painter.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 February 2004
Engineering › Fuel Oil Service System
Issued 20 November 2003 Resolved
Provide shut off valve on engine side of main engine fuel supply line. LEGACY COMPONENT DESC: Valve
Condition: Improper Installation
Due 19 December 2003
Resolved 24 February 2004
Engineering › Fuel Oil Service System
Issued 20 November 2003 Resolved
Mark location of Emergency fuel shut off valves on main deck at the valve location. LEGACY COMPONENT DESC: Valve
Due 19 December 2003
Resolved 24 February 2004
Electrical
Issued 20 November 2003 Resolved
Lable breakers in wheelhouse breaker pannel. LEGACY COMPONENT DESC: Breaker pannel
Due 19 December 2003
Resolved 24 February 2004
Pollution Prevention/Response › Prevention Equipment
Issued 20 November 2003 Resolved
Provide lock on over board discharge valve to prevent accidental discharge. LEGACY COMPONENT DESC: Marine Sanitation Device, Type III
Due 19 December 2003
Resolved 24 February 2004
Documentation › Certificates/Documents › FCC SSL
Issued 9 December 2002 Resolved
PROVIDE VALID FCC SAFETY CERTIFICATE.
Action required: 705 - Other - as specified
Due 4 January 2003
Resolved 20 August 2004
Communications › Alarms/Indicators › Bilge Alarm
Issued 9 December 2002 Resolved
LABEL BOTH BILGE HIGH WATER ALARMS AT THE OPERATING STATION.
Action required: 705 - Other - as specified
Due 4 January 2003
Resolved 20 August 2004
Lifesaving › Buoyant Apparatus › Pendant
Issued 9 December 2002 Resolved
REPLACE GRAB LINES ON BOTH LIFE FLOATS DUE TO DETERIORATION.
Action required: 705 - Other - as specified
Due 4 January 2003
Resolved 20 August 2004
Documentation
Issued 19 November 2001 Resolved
PROVIDE PROOF OF ENROLLMENT IN DRUG TESTING PROGRAM.
Condition: Unknown
Due 28 November 2001
Resolved 3 December 2001
Documentation
Issued 20 December 1999 Resolved
Post stability letter.
Condition: Unknown
Due 20 December 1999
Resolved 20 December 1999
Fire Fighting
Issued 20 December 1999 Resolved
Install two B2 fire extinguishers.
Condition: Unknown
Due 20 January 2000
Resolved 11 January 2000
Navigation
Issued 20 December 1999 Resolved
Provide bell.
Condition: Unknown
Due 20 December 1999
Resolved 20 December 1999
Documentation
Issued 20 December 1999 Resolved
Provide drug monitoring program information.
Condition: Unknown
Due 20 January 2000
Resolved 29 December 1999
Engineering
Issued 15 April 1999 Resolved
REPLACE CUTLESS BEARING ON SHAFT.
Condition: Unknown
Due 20 May 1999
Resolved 12 May 1999
Documentation
Issued 16 November 1998 Resolved
ENSURE CERTIFICATE OF DOCUMENTATION IS PROPERLY ENDORSED WITH "COASTWISE" ENDORSEMENT.
Condition: Unknown
Due 16 November 1998
Resolved 16 November 1998
Lifesaving
Issued 16 November 1998 Resolved
RENEW PFD DONNING PLACARD.
Condition: Unknown
Due 16 November 1998
Resolved 16 November 1998
Engineering
Issued 13 April 1998 Resolved
PROVIDE PROPER MARKINGS FOR EMERGENCY FUEL SHUTOFFS.
Condition: Unknown
Due 13 April 1998
Resolved 13 April 1998
Engineering
Issued 13 April 1998 Resolved
FPROVIDE USCG APPROVED HOSE FOR FUEL VENT.
Condition: Unknown
Due 13 April 1998
Resolved 13 April 1998
Lifesaving
Issued 13 April 1998 Resolved
PROVIDE 2 PADDLES FOR EACH LIFE FLOAT.
Condition: Unknown
Due 13 April 1998
Resolved 13 April 1998
Navigation
Issued 13 April 1998 Resolved
PROVIDE UP-TO-DATE CHART.
Condition: Unknown
Due 13 April 1998
Resolved 13 April 1998
Lifesaving
Issued 13 April 1998 Resolved
PROVIDE 1 ADDITIONAL CHILD PFD.
Condition: Unknown
Due 13 April 1998
Resolved 13 April 1998
Engineering
Issued 13 April 1998 Resolved
PROVIDE GROUND BETWEEN FUEL FILL AND FUEL TANK.
Condition: Unknown
Due 13 April 1998
Resolved 13 April 1998

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.