MAURY USCG vessel records Sign in
← All vessels

CAPE SPENCER

CAPE SPENCER is a 1997 freight ship. The Coast Guard has recorded 26 inspections since 1997, most recently in August 2015, along with 11 deficiencies and 4 operational controls.

Records from 1997 to 2015. Most recent: inspection, 20 August 2015.

Built
1997
Last inspected
20 August 2015
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9159725 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
455209
Flag
HONG KONG
—
Maury page id
psix-455209

Inspections, by type

…with no type recorded15
Years with a record 14 calendar years (1997–2015)
The 26 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 11 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it17377 - Regulatory (Subpart C or D), Gross Ton
17377 - Convention (Subpart B), Gross Ton
10133 - Regulatory (Subpart C or D), Net Ton
10133 - Convention (Subpart B), Net Ton
34813 - Displacement, Ton
28799 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 26

20 August 2015 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5220991
9 November 2010 COE-Dockside
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3888542
5 July 2008 NPV Safety Exam
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3257903
25 November 2007 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3104096
2 July 2007 Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2981066
18 April 2007 Type not recorded
No type recorded · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2910422
14 February 2006 Type not recorded
No type recorded · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2585266
25 October 2005 Type not recorded
No type recorded · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2522171
24 October 2005 Ballast Water Examination · ISPS II Exam · PII Safety Exam · MARPOL Annex I Examination
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2518802
29 October 2004 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2232756
20 September 2004 NPV Safety Exam
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2200181
6 August 2004 ISPS II Exam
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2151218
5 April 2004 MARPOL Annex V Examination · MARPOL Annex I Examination · Annual Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2037700
27 August 2003 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1889792
4 March 2003 Annual Inspection · MARPOL Annex I Examination · Ballast Water Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1749538
15 April 2002 MARPOL Annex I Examination · Passenger/Freight Vessel Examination · Annual Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1605018
13 June 2001 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 290887
25 January 2001 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 286216
13 June 2000 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 278755
27 December 1999 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 436052
25 May 1999 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 428775
1 March 1999 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 425889
13 January 1999 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 424326
11 June 1998 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 416868
5 May 1998 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 415323
30 April 1997 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 403030

Deficiency record · 11

Lifesaving › Lifeboat › Propulsion Engine
Issued 20 August 2015 Resolved
0615; Before ship leaves port, and at all times during the voyage, all life saving appliances shall be in working order and ready for immediate use. The rescue boat fuel tank has been patched. There is no documentation stating when or who installed the patch. In addition, batteries in both life boats were not mounted and handles were not ready for immediate release. 74SOLAS (83 cons) III/19.2.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 24 August 2015
Resolved 25 August 2015
Resolution: Addressed and corrected to the satisfaction of the attending Classification Representative.
Accommodation/Occupational Safety › Ventilation › General
Issued 20 August 2015 Resolved
0320; The ventilation systems of cargo ships shall be in compliance with the provisions of regulation 16. Ship's ducting in A/C room is wasted. 74 SOLAS (83 cons) II-2/48, 17A/C.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 24 August 2015
Resolved 25 August 2015
Resolution: Addressed and corrected to the satisfaction of the attending Classification Representative.
Construction/Loadline › Structures › Air Pipe
Issued 20 August 2015 Resolved
1275; Where required by regulation 19, weather tight closing appliances for all ventilators in position 1 and 2 are to be of steel and other equivalent materials. Plastic caps were found on starboard water ballast tank #2, forepeak tank, and two bilge tanks. ICLL 66 19.4, 17A/C.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 24 August 2015
Resolved 25 August 2015
Resolution: Addressed and corrected to the satisfaction of the attending Classification Representative.
Fire Fighting › Ventilation Systems › Grouping
Issued 20 August 2015 Resolved
0745; In addition to complying with the specific provisions for the integrity of bulkheads and decks mentioned elsewhere in this part, the minimum fire integrity of bulkheads and decks shall be as prescribed in tables 44.1 and 44.2. Natural air vents around the accommodation house, mast houses, and forward Bos’n store are not closing properly. 74 SOLAS (83 cons) II-2/44, 17A/C.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 24 August 2015
Resolved 25 August 2015
Resolution: Addressed and corrected to the satisfaction of the attending Classification Representative.
Fire Fighting › Fire Main › Condition
Issued 20 August 2015 Resolved
2510; The machinery, boilers and other pressure vessels, associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended. Fire main by #4 topside tank is patched and hydraulic line by #2 topside tank is patched. 74 SOLAS (83 cons) II-1/26, 17A/C.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 24 August 2015
Resolved 25 August 2015
Resolution: Addressed and corrected to the satisfaction of the attending Classification Representative.
Documentation › Logs/Records › Ballast Water Logs/Records
Issued 20 August 2015 Resolved
2510; Vessels must maintain a Ballast Water Management Plan that has been developed specifically for the vessel. Vessel has a Ballast and Bio-fouling plans but the crew is not following the procedure for documenting maintenance, 33CFR1512050(g), IMO Resolution 207(62).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 August 2015
Resolved 20 August 2015
Resolution: Spoke with Captain, [name withheld], Chief Office and Chief Engineer about the requirements for documentation as per their plans.
Navigation › Collision/Grounding Avoidance › Transponder
Issued 5 July 2008 Resolved
Inoperable AIS. Vessel was issued an LOD. Fix prior to departure.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 July 2008
Resolution: Technician replaced AIS transponder unit and certified normal transmission. LOD removed.
Fire Fighting › Miscellaneous Items › A Class Division Penetrations
Issued 25 November 2007 Resolved
Several doors in the main stairwell and leading to the engine room were not self closing posing undue risk to the crew and ship. SOLAS 1997 Ch II-2 Reg 47.1 10c
Due 4 December 2007
Resolved 4 December 2007
Resolution: Corrected on the spot to the satisfaction of the Coast Guard
Fire Fighting
Issued 13 June 2001 Resolved
Conduct a satisfactory fire drill in the presence of Coast Guard boarding officers prior to departing from this port. SOLAS 74 amd III/18
Condition: Unknown
Due 14 June 2001
Resolved 14 June 2001
Accommodation/Occupational Safety
Issued 13 January 1999 Resolved
Vessel does not have a Waste Management Plan in accordance with Marpol 73/78 Annex V, Regulation 9(ii).
Condition: Unknown
Due 2 March 1999
Resolved 2 March 1999
Documentation
Issued 5 May 1998 Resolved
Vessel's SOPEP found missing the necessary list of Coastal States Contact numbers in USA for the Seattle/Tacoma region.
Condition: Unknown
Due 23 June 1998
Resolved 23 June 1998

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.