Records from 1997 to 2017. Most recent: inspection, 27 April 2017.
Inspection history · 24
27 April 2017
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6133994
9 October 2014
Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5002302
15 August 2011
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4134087
10 August 2011
Deficiency Check
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 4111669
26 July 2011
COI Inspection · MTSA Verification
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 4094834
27 October 2010
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3879246
28 October 2008
Administrative Inspection · Ballast Water Examination · Re-Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3352307
23 July 2007
Hull Examination · MTSA Verification · Internal Structural Exam · Ballast Water Examination · Examination of Repairs · Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3005267
11 May 2007
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2933135
31 July 2006
COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2731331
5 August 2005
Re-Inspection · Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2452139
28 October 2004
MTSA Verification · Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2229899
30 January 2004
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1998565
6 October 2003
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1922132
7 November 2002
Damage Survey
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1702164
6 November 2002
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1704942
12 July 2002
Hull Examination · Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1645104
30 July 2001
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1459732
10 August 2000
Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1418753
29 July 1999
COI Inspection · Damage Survey
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1463518
7 January 1999
Type not recorded
No type recorded · USCG Heartland District (dp) · USCG Heartland District (CGD-H) · Activity 730153
6 January 1999
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 810598
13 July 1998
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1364784
1 August 1997
Inclining Experiment · Initial Construction-Excluding Oversight · Initial Certification
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1441284
Engineering › Fuel Oil Service System › Piping
Issued 9 October 2014
Resolved
Several sections of non-metallic fuel piping were in excess of 30" 46 CFR 56.60-25 (b) (4)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 9 November 2014
Resolved 10 October 2014
Resolution: All excessive lengths of non-metallic hose were replaced with metallic piping.
Engineering › Fuel Oil Service System › Filter
Issued 9 October 2014
Resolved
Both outboard Main Propulsion engine fuel filter mounts were loose causing excessive movement of the fuel filters.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 October 2014
Resolution: Fuel filter mounting brackets were properly secured.
Accommodation/Occupational Safety › Potable Water System › General
Issued 9 October 2014
Resolved
The electric water heater is badly corroded and secured with a single piece of manila line.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 November 2014
Resolved 10 October 2014
Resolution: A new electric water heater was installed.
Construction/Loadline › Penetrations › Pipe Flange
Issued 26 July 2011
Resolved
Replace/repair overboard discharge line IAW 46 CFR 56.50-95.
Action required: 705 - Other - as specified
Due 11 August 2011
Resolved 10 August 2011
Resolution: Received photgraph of repairs, cleared deficiency.
Deck/Cargo › Towing › Towline
Issued 26 July 2011
Resolved
Provide messenger line for shoulder line throwing gun IAW 46 CFR 160.031.
Action required: 705 - Other - as specified
Due 11 August 2011
Resolved 10 August 2011
Resolution: Received photo of new messenger, cleared deficiency.
Electrical › Electric Generation Source (service) › Generator
Issued 28 October 2008
Resolved
Provide 3rd party report for servicing of both generators and overspeed
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 October 2008
Lifesaving › Buoyant Apparatus › Approval
Issued 28 October 2008
Resolved
Replace both life floats due to excessive wear in lines
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 October 2008
Lifesaving › Buoyant Apparatus › Float-free Link
Issued 28 October 2008
Resolved
Properly install float free weak link
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 October 2008
Communications › Radio Communications › EPIRB
Issued 28 October 2008
Resolved
Install hydrostatic release for EPIRB
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 October 2008
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 28 October 2004
Resolved
Provide an updated Fire Control Plan for CG approval.
Action required: 705 - Other - as specified
Due 28 November 2004
Resolved 6 December 2004
Engineering › Bilge Water Management System
Issued 6 October 2003
Resolved
Bilge alarms on pilothouse panel for need to be split into two separate visual alarms. LEGACY COMPONENT DESC: Alarms
Action required: 705 - Other - as specified
Due 6 November 2003
Resolved 13 October 2003
Navigation › Piloting/Steering
Issued 6 October 2003
Resolved
Provide updated Coast Pilot prior to sailing. LEGACY COMPONENT DESC: US Coast Pilot
Action required: 17 - Rectify deficiencies prior to departure
Due 6 November 2003
Resolved 6 October 2003
Navigation › Piloting/Steering
Issued 6 October 2003
Resolved
Provide Local Notice to Mariners prior to sailing. LEGACY COMPONENT DESC: Local Notices to Mariners
Action required: 17 - Rectify deficiencies prior to departure
Due 6 November 2003
Resolved 6 October 2003
Navigation › Piloting/Steering
Issued 6 October 2003
Resolved
Provide updated local charts prior to sailing. LEGACY COMPONENT DESC: Marine Charts
Action required: 17 - Rectify deficiencies prior to departure
Due 6 November 2003
Resolved 6 October 2003
Engineering › Shafting/Propeller Arrangements
Issued 6 October 2003
Resolved
Repair center engine shaft tachometer. LEGACY COMPONENT DESC: Propeller Shaft
Action required: 705 - Other - as specified
Due 6 November 2003
Resolved 13 October 2003
Engineering › Diesel Engine (propulsion-direct drive)
Issued 6 October 2003
Resolved
Repair all engine tachometers. LEGACY COMPONENT DESC: Engine Tachometer
Action required: 705 - Other - as specified
Due 6 November 2003
Resolved 13 October 2003
Engineering › Steering Gear System
Issued 6 October 2003
Resolved
Repair steering pump power available light. LEGACY COMPONENT DESC: Power Light
Action required: 705 - Other - as specified
Due 6 November 2003
Resolved 13 October 2003
Lifesaving › Line-Throwing Appliances › Lines
Issued 6 October 2003
Resolved
Provide messenger line for line throwing gun. Five-hundred feet with nine thousand pound breaking strength.
Action required: 705 - Other - as specified
Due 6 November 2003
Resolved 6 October 2003
Deck/Cargo › Holds/Tanks
Issued 6 October 2003
Resolved
Demonstrate proper operation of liquid mud pump shut downs (remote stops). LEGACY COMPONENT DESC: Shut off Device
Action required: 705 - Other - as specified
Due 6 November 2003
Resolved 13 October 2003
Engineering › Fuel Oil Service System › Hose
Issued 6 October 2003
Resolved
Renew three fuel lines on all main engines not meeting J-1942 hose standards prior to 06 NOV 2003.
Action required: 705 - Other - as specified
Due 6 November 2003
Resolved 6 October 2003
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 12 July 2002
Resolved
RENEW ONE WORN FUEL OIL FLEXIBLE HOSE ON CENTER MAIN ENGINE. LEGACY COMPONENT DESC: FLEXIBLE HOSE
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 15 August 2002
Resolved 15 July 2002
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 12 July 2002
Resolved
RENEW ONE WORN LUBE OIL FLEXIBLE HOSE ON CENTER MAIN ENGINE. LEGACY COMPONENT DESC: FLEXIBLE HOSE
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 15 August 2002
Resolved 15 July 2002
Construction/Loadline › Structures
Issued 12 July 2002
Resolved
RENEW FLAME SCREENS IN ALL LIQUID MUD VENTS. LEGACY COMPONENT DESC: Air Pipe
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 August 2002
Resolved 15 July 2002
Construction/Loadline
Issued 10 August 2000
Resolved
REPAIR 02 BUCKLED SWASH BULKHEADS IWO SIDE SHELL IN NUMBER 4 PORT BALLAST TANK, TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 10 August 2000
Resolved 10 August 2000