MARINER II is a 1967 passenger vessel (inspected). The Coast Guard has recorded 42 inspections since 1985, most recently in August 2001, along with 92 deficiencies.

Records from 1985 to 2001. Most recent: inspection, 20 August 2001.

Built
1967
Last inspected
20 August 2001
Documentation
Expired · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WSC4638
Flag
UNITED STATES
—
Maury page id
psix-45523

Inspections, by type

…with no type recorded3
Years with a record 17 calendar years (1985–2001)
The 42 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 25 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)57.8 ft × 16.3 ft × 5.7 ft
Registered tonnagegross 59 / net 40
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderPACEMAKER CORPORATION · LOWER BANK NJ, UNITED STATES · built 1967
Hull materialWood
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portSAN FRANCISCO, CA
Trade endorsementsCoastwise, unrestricted
DocumentationExpired · issued 23 February 2000 · expires 28 February 2001
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it40 - Regulatory (Subpart C or D), Net Ton
59 - Regulatory (Subpart C or D), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 42

20 August 2001 Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1070463
3 February 2000 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 816855
13 March 1999 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1125379
3 February 1999 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 790587
23 March 1998 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1124499
23 February 1998 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 780303
10 April 1997 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1093561
20 March 1997 Deficiency Check · Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1402413
6 February 1997 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1103094
29 February 1996 Re-Inspection · Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1367658
25 October 1995 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1185687
27 September 1995 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 881818
1 May 1995 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1219760
4 April 1995 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1394322
16 March 1994 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 859337
10 February 1994 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 852749
12 July 1993 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 844863
12 July 1993 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 847332
12 May 1993 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1144193
2 April 1993 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 836937
17 February 1993 Re-Inspection · Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1144152
23 March 1992 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1254543
20 February 1992 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 954652
13 August 1991 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 942576
9 May 1991 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1235348
19 April 1991 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1234211
26 March 1991 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1213809
13 February 1991 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 908814
4 May 1990 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 906981
5 April 1990 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1229608
22 March 1990 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1223584
21 March 1990 Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 934958
28 February 1989 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1197642
1 February 1989 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1200545
19 February 1988 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1021267
7 July 1987 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1012847
27 February 1987 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1016972
11 February 1987 Re-Inspection · Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1320246
24 February 1986 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1307009
18 February 1986 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1295209
5 March 1985 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 978521
11 February 1985 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 977404

Deficiency record · 92

Lifesaving
Issued 3 February 1999 Resolved
PROVIDE LIFE LINE TO LIFE RING PRIOR TO TAKING ON PASSENGERS.
Condition: Unknown
Due 3 February 1999
Resolved 3 February 1999
Lifesaving
Issued 3 February 1999 Resolved
PROVIDE 3 CHILD SIZE LIFE JACKETS OF TYPE I. LIMITED TO 3 CHILDREN UNTIL LIFE JACKETS PROVIDED.
Condition: Unknown
Due 3 February 1999
Resolved 3 February 1999
Navigation
Issued 23 February 1998 Resolved
UPDATE MAGNETIC COMPASS DEVIATION CARD.
Condition: Unknown
Due 23 February 1998
Resolved 23 February 1998
Electrical
Issued 23 February 1998 Resolved
PROVIDE METALLIC WIRE CLIPS FOR ELECTRIC WIRES IN ENGINE ROOM.
Condition: Unknown
Due 23 February 1998
Resolved 23 February 1998
Construction/Loadline
Issued 23 February 1998 Resolved
TREAT FIRRING IN ENGINE ROOM WHERE NECESSARY.
Condition: Unknown
Due 23 February 1998
Resolved 23 February 1998
Accommodation/Occupational Safety
Issued 23 February 1998 Resolved
REPAIR CRACK IN FORWARD STARBOARD SIDE RAIL.
Condition: Unknown
Due 23 February 1998
Resolved 23 February 1998
Lifesaving
Issued 23 February 1998 Resolved
MAKE SURFACE REPAIRS TO BUOYANT APPARATUS.
Condition: Unknown
Due 23 February 1998
Resolved 23 February 1998
Engineering
Issued 23 February 1998 Resolved
RE-LABEL FUEL SHUTOFF VALVES (INCLUDING DIRECTION ARROWS) AND ATTACH REACH ROD ON DECK ADJACENT TO STARBOARD FUEL SHUTOFF VALVES.
Condition: Unknown
Due 23 February 1998
Resolved 23 February 1998
Accommodation/Occupational Safety
Issued 6 February 1997 Resolved
REPAIR CRACKED RAILING ON STBD SIDE NEAR BOARDING AREA.
Condition: Unknown
Due 6 February 1997
Resolved 6 February 1997
Electrical
Issued 6 February 1997 Resolved
REPLACE WIRE NUTS UNDER FLYING BRIDGE CONSOLE WITH PROPER CONNECTIONS.
Condition: Unknown
Due 6 February 1997
Resolved 6 February 1997
Lifesaving
Issued 6 February 1997 Resolved
PROVIDE RETRO-REFLECTIVE TAPE FOR RING BUOYS.
Condition: Unknown
Due 6 February 1997
Resolved 6 February 1997
Electrical
Issued 6 February 1997 Resolved
REPAIR/REPLACE HANGER OVER STBD MAIN ENGINE.
Condition: Unknown
Due 6 February 1997
Resolved 6 February 1997
Construction/Loadline
Issued 6 February 1997 Resolved
REPAIR/REPLACE ROTTED WOOD IN WAY OF HATCH COAMINGS IN LAZARETTE AND ON AFTERMOST TRANSVERSE DECK BEAM CENTERLINE.
Condition: Unknown
Due 6 February 1997
Resolved 6 February 1997
Documentation
Issued 29 February 1996 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 31 March 1996
Resolved 1 April 1996
Lifesaving
Issued 29 February 1996 Resolved
REPLACE RETRO PANELS ON TWO CHILD LIFE JACKETS. VESSEL IS LIMITED TO CARRYING 4 CHILDREN.
Condition: Unknown
Due 31 March 1996
Resolved 1 April 1996
Deck/Cargo
Issued 29 February 1996 Resolved
PROVE PROPER OPERATION OF WINDLASS.
Condition: Unknown
Due 31 March 1996
Resolved 1 April 1996
Documentation
Issued 29 February 1996 Resolved
PROVIDE CURRENT STAMP FOR VESSEL DOCUMENT.
Condition: Unknown
Due 31 March 1996
Resolved 1 April 1996
Construction/Loadline
Issued 27 September 1995 Resolved
PERFORM AN UNDERWAY TEST TO CHECK CONDITION OF REPAIRS AND AREAS HARD TO INSPECT DURING DRYDOCK EXAM.
Condition: Unknown
Due 27 September 1995
Resolved 27 September 1995
Construction/Loadline
Issued 27 September 1995 Resolved
COMPLETE INSTALLATION OF SISTER FRAMES INTO THE SHEER CLAMP IN THE ENGINE ROOM.
Condition: Unknown
Due 27 September 1995
Resolved 27 September 1995
Navigation
Issued 4 April 1995 Resolved
PROVIDE LATEST EDITION NAVIGATIONAL CHART OF OPERATING AREA.
Condition: Unknown
Due 4 April 1995
Resolved 4 April 1995
Electrical
Issued 4 April 1995 Resolved
REMOVE OLD ELECTRICAL WIRING DISCONNECTED IN BILGE OUTBOARD OF PORT STERN TUBE.
Condition: Unknown
Due 4 April 1995
Resolved 4 April 1995
Navigation
Issued 4 April 1995 Resolved
SERVICE THE STEERING COMPASS ON THE FLYING BRIDGE SO AS TO REMOVE THE AIR BUBBLE.
Condition: Unknown
Due 4 April 1995
Resolved 4 April 1995
Navigation
Issued 4 April 1995 Resolved
PROVIDE LATEST EDITION OF 46 CFR SUBCHAPTER T.
Condition: Unknown
Due 4 April 1995
Resolved 4 April 1995
Construction/Loadline
Issued 4 April 1995 Resolved
CROP & RENEW SHELF SUPPORTING DECK BEAMS ON STBD SIDE OF LAZARETTE WHER DRYROTTED. RENEWD WOOD MUST EXTEND AT LEAST 3 FRAMES.
Condition: Unknown
Due 4 April 1995
Resolved 4 April 1995
Lifesaving
Issued 4 April 1995 Resolved
PROVIDE HYDROSTATIC RELEASE ON TIE DOWN STRAPS FOR BUOYANT APPARATUS.
Condition: Unknown
Due 4 April 1995
Resolved 4 April 1995
Lifesaving
Issued 4 April 1995 Resolved
STENCIL VESSEL NAME ON RINGBUOY.
Condition: Unknown
Due 4 April 1995
Resolved 4 April 1995
Lifesaving
Issued 4 April 1995 Resolved
MODIFY PLACARD FOR ADULT LIFEJACKET STOWAGE TO INCLUDE THE WORDS "UNDER SEATS".
Condition: Unknown
Due 4 April 1995
Resolved 4 April 1995
Electrical
Issued 4 April 1995 Resolved
PROPERLY TERMINATE IN A JUNCTION BOX THE LOOSE DISCONNECTED ELECTRICAL WIRING IN THE FORWARD STORAGE LOCKER PORTSIDE.
Condition: Unknown
Due 4 April 1995
Resolved 4 April 1995
Engineering
Issued 10 February 1994 Resolved
OVERHAUL BOTH SHAFT LOGS.
Condition: Unknown
Due 10 March 1994
Resolved 16 March 1994
Engineering
Issued 10 February 1994 Resolved
DRAW BOTH SHAFTS FOR EXAMINATION.
Condition: Unknown
Due 10 March 1994
Resolved 16 March 1994
Engineering
Issued 10 February 1994 Resolved
CORRECT EXCESSIVE PRT & STB SHAFT VIBRATIONS.
Condition: Unknown
Due 10 March 1994
Resolved 16 March 1994
Construction/Loadline
Issued 10 February 1994 Resolved
PROPERLY SECURE TO PLANKS THE RIBS IN LAZ SPACE (PRT SIDE; 2ND FROM STERN AND STB; 2,3,4,5,6,7 & 8 FORM STERN).
Condition: Unknown
Due 10 March 1994
Resolved 16 March 1994
Electrical
Issued 10 February 1994 Resolved
PROPERLY SECURE 110 WIRING NOW IN CONTACT W/PRT WET EXHAUST MANIFOLD IN FWDHEAD.
Condition: Unknown
Due 10 March 1994
Resolved 16 March 1994
Accommodation/Occupational Safety
Issued 10 February 1994 Resolved
PROPERLY MARK EXTERIOR OF ESCAPE HATCH TO KEEP CLEAR.
Condition: Unknown
Due 10 March 1994
Resolved 16 March 1994
Electrical
Issued 10 February 1994 Resolved
SECURE GENERATOR BATTERIES IN E/R.
Condition: Unknown
Due 10 March 1994
Resolved 16 March 1994
Lifesaving
Issued 10 February 1994 Resolved
PROVIDE 3 ADD'L ADULT PFD'S. VSL RESTRICTED TO 48 PERSONS ON BOARD UNTIL PFD'S ARE PROVIDED.
Condition: Unknown
Due 10 March 1994
Resolved 16 March 1994
Navigation
Issued 10 February 1994 Resolved
PROVIDE ANCHOR LIGHT.
Condition: Unknown
Due 10 March 1994
Resolved 16 March 1994
Construction/Loadline
Issued 10 February 1994 Resolved
MAKE VSL AVAILABLE FOR CG DDX TO EXAMINE HULL INTEGRITY (INCL. ACCESS TO AFT STATE RM HULL).
Condition: Unknown
Due 10 March 1994
Resolved 16 March 1994
Construction/Loadline
Issued 10 February 1994 Resolved
DURING DD, REPAIR THE ROTTED RIB LOCATED AT THE FWD BLKH IN E/R ON STB SIDE.
Condition: Unknown
Due 10 March 1994
Resolved 16 March 1994
Construction/Loadline
Issued 10 February 1994 Resolved
DURING DD, PULL AT LEAST 8 REPRESENTATIVE FASTENERS TO BE IDENTIFIED BY THECG INSPECTOR.
Condition: Unknown
Due 10 March 1994
Resolved 16 March 1994
Accommodation/Occupational Safety
Issued 12 May 1993 Resolved
STRENGTHEN HAND RAILS IN ACCORDANCE WITH PLANS RECEIVED BY MSO S.F. 30APR92AND HAVE WORK INSPECTED BY A CG MARINE INSPECTOR.
Condition: Unknown
Due 12 May 1993
Resolved 12 May 1993
Accommodation/Occupational Safety
Issued 2 April 1993 Resolved
PROVIDE PLANS FOR APPROVAL FOR STRENGTHENING WHEELHOUSE DECK HAND RAILS.
Condition: Unknown
Due 2 April 1993
Resolved 2 April 1993
Lifesaving
Issued 17 February 1993 Resolved
RENEW B/A LIGHT LINE.
Condition: Unknown
Due 12 July 1993
Resolved 12 July 1993
Lifesaving
Issued 17 February 1993 Resolved
PROVIDE 3 ADDITIONAL RED FLARES.
Condition: Unknown
Due 5 April 1993
Resolved 5 April 1993
Engineering
Issued 17 February 1993 Resolved
PROVIDE INSULATION FOR OUTBOARD, STB EXHAUST AND RENEW WIRING IN WAY OF SAME.
Condition: Unknown
Due 5 April 1993
Resolved 5 April 1993
Lifesaving
Issued 17 February 1993 Resolved
PROVIDE 2 ADD'L PFD'S, VESSEL RESTRICTED TO 49 PERSON'S ON BOARD, UNTIL ADD'L PFD'S PROVIDED.
Condition: Unknown
Due 5 April 1993
Resolved 5 April 1993
Electrical
Issued 17 February 1993 Resolved
PROPERLY BRACE BATERIES IN FWD BATTERY BOX.
Condition: Unknown
Due 5 April 1993
Resolved 5 April 1993
Lifesaving
Issued 17 February 1993 Resolved
STENSILE NAME OF VESSEL AND CAPACITY ON B/A.
Condition: Unknown
Due 12 July 1993
Resolved 12 July 1993
Documentation
Issued 20 February 1992 Resolved
PROVIDE PROOF OF RANDOM DRUG TESTING PROGRAM.
Condition: Unknown
Due 24 March 1992
Resolved 24 March 1992
Electrical
Issued 20 February 1992 Resolved
REPAIR ELECTRICAL BONDING IN WAY OF PORT RUDDER POST.
Condition: Unknown
Due 24 March 1992
Resolved 24 March 1992
Engineering
Issued 20 February 1992 Resolved
PROPERLY MARK PORT AFT FUEL SHUT OFF VALVE.
Condition: Unknown
Due 24 March 1992
Resolved 24 March 1992
Electrical
Issued 20 February 1992 Resolved
SECURE OR REMOVE EXCESS WIRE ON OUTSIDE OF STBD FUEL TANK.
Condition: Unknown
Due 24 March 1992
Resolved 24 March 1992
Lifesaving
Issued 20 February 1992 Resolved
PROVIDE ADDITIONAL PFD'S, 1C AND 4A. VSL IS LIMITED TO FOUR 7A & 5C UNTIL COMPLETED.
Condition: Unknown
Due 24 March 1992
Resolved 24 March 1992
Documentation
Issued 20 February 1992 Resolved
PROVIDE A COPY OF NAV RULES OF THE ROAD.
Condition: Unknown
Due 24 March 1992
Resolved 24 March 1992
Lifesaving
Issued 20 February 1992 Resolved
REPLACE LINE CONNECTING WATERLIGHT TO BUOYANT APPARATUS. ITEM SHALL BE COMPLETED PRIOR TO GOING GREATER THAN 1 MILE OFF SHORE.
Condition: Unknown
Due 24 March 1992
Resolved 24 March 1992
Accommodation/Occupational Safety
Issued 13 February 1991 Resolved
MAKE TIGHT ALL RAILINGS ON MAIN DECK. MOST BRACKET SUPPORTS AT DECK AREA ARE LOOSE. BOLTS/SCREWS NEED TO BE TIGHTENED OR ANOTHER FASTENING SYSTEM INTALLED. ALSO TIGHTEN LAZZERETTE RAILING IN AREA STARBOARD SIDE AFTER MOST BRACKET.
Condition: Unknown
Due 13 February 1991
Resolved 13 February 1991
Lifesaving
Issued 13 February 1991 Resolved
REPLACE 6 ORANGE SMOKE SIGNALS WHICH EXPIRE MARCH 1991.
Condition: Unknown
Due 13 February 1991
Resolved 13 February 1991
Lifesaving
Issued 13 February 1991 Resolved
REPLACE LINE AND BATTERY TO FLOATING STROBE LIGHT ON RING BUOYS, MUST BE ACCOMPLISHED PRIOR TO CARRYING PASSENERS.
Condition: Unknown
Due 13 February 1991
Resolved 13 February 1991
Navigation
Issued 13 February 1991 Resolved
REPLACE WASTED WOOD SHIMS IN WAY OF PORT AND STARBOARD RUDDER POST TRANSVERSE SUPPORT BRACKETS.
Condition: Unknown
Due 13 February 1991
Resolved 13 February 1991
Lifesaving
Issued 13 February 1991 Resolved
REPLACE 1 ADULT PFD, TAPE 1 CHILD PFD. VESSEL IS RESTRICTED TO 50 PERSONS UNTIL COMPLETED.
Condition: Unknown
Due 13 February 1991
Resolved 13 February 1991
Construction/Loadline
Issued 13 February 1991 Resolved
PROVIDE CHAIN AND LOCKING DEVICE FOR BOTH LAZZERETTE HATCH COVERS AS PER 46CFR, SUBCHAPTER T, 171.124.
Condition: Unknown
Due 13 February 1991
Resolved 13 February 1991
Construction/Loadline
Issued 13 February 1991 Resolved
REPAIR DEPTH INDICATOR.
Condition: Unknown
Due 13 February 1991
Resolved 13 February 1991
Electrical
Issued 13 February 1991 Resolved
ENGINE ROOM ELECTRICAL PLUG BOXES MUST BE REPLACED WITH 3-PRONG GROUNDED TYPE, RECEPTICALS ALSO NEED COVERS.
Condition: Unknown
Due 13 February 1991
Resolved 13 February 1991
Electrical
Issued 13 February 1991 Resolved
PROVIDE COVERS FOR BACK OF BILGE PUMP SWITCHES, BARE WIRING IS EXPOSED.
Condition: Unknown
Due 13 February 1991
Resolved 13 February 1991
Lifesaving
Issued 5 April 1990 Resolved
1 PROVIDE 3 ADULT LIFE PRESERVERS. VESSEL IS RESTRICTED TO A TOTAL OF 48 PERSONS UNTIL LIFE PRESERVERS ARE ABOARD.
Condition: Unknown
Due 5 April 1990
Resolved 5 April 1990
Engineering
Issued 5 April 1990 Resolved
7 STENCIL BOTH FORWARD EMERGENCY FUEL SHUT-OFFS.
Condition: Unknown
Due 5 April 1990
Resolved 5 April 1990
Fire Fighting
Issued 5 April 1990 Resolved
2 PROVIDE SUCTION HOSE APPROXIMATELY 10 FOOT IN LENGTH FOR HAND PUMP.
Condition: Unknown
Due 5 April 1990
Resolved 5 April 1990
Electrical
Issued 5 April 1990 Resolved
4 PROVIDE 2 ADDITIONAL FLASHLIGHTS FOR A TOTAL OF 3.
Condition: Unknown
Due 5 April 1990
Resolved 5 April 1990
Documentation
Issued 5 April 1990 Resolved
5 OBTAIN FCC OPERATORS PERMIT FOR OPERATOR.
Condition: Unknown
Due 5 April 1990
Resolved 5 April 1990
Navigation
Issued 5 April 1990 Resolved
6 PROVIDE COMPASS DEVIATION CHART.
Condition: Unknown
Due 5 April 1990
Resolved 5 April 1990
Construction/Loadline
Issued 28 February 1989 Resolved
PROVIDE DECK RAILS AROUND STERN DECK WELL THAT MEEETS THE REQUIREMENTS OF 46 CFR 177.35.
Condition: Unknown
Due 28 February 1989
Resolved 28 February 1989
Electrical
Issued 28 February 1989 Resolved
REMOVE LOOSE, UNUSED WIRING FROM RUDDER COMPT.
Condition: Unknown
Due 28 February 1989
Resolved 28 February 1989
Lifesaving
Issued 28 February 1989 Resolved
PROVIDE ONE ADDITIONAL ADULT LIFE PRESERVER, VESSELS PASSENGERS CAPACITY REDUCED TO 48, UNTILL ONEMORE PFD IS PROVIDED.
Condition: Unknown
Due 28 February 1989
Resolved 28 February 1989
Construction/Loadline
Issued 28 February 1989 Resolved
REPAIR AND RE-SECURE STARBOARD DECK RAILS.
Condition: Unknown
Due 28 February 1989
Resolved 28 February 1989
Lifesaving
Issued 28 February 1989 Resolved
REPLACE BOYANT APPARATUS BREAKABLE LINK.
Condition: Unknown
Due 28 February 1989
Resolved 28 February 1989
Accommodation/Occupational Safety
Issued 19 February 1988 Resolved
PROVIDE DECK RAILS WHICH COMPLY WITH 46 CFR 177.35 AND IN ACCORDANCE WITH APPROVED PLANS BY 19 FEBRUARY 1989.
Condition: Unknown
Due 19 February 1988
Resolved 19 February 1988
Documentation
Issued 11 February 1987 Resolved
DISPLAY COPY OF VESSEL'S STABILITY LETTER.
Condition: Unknown
Due 11 February 1987
Resolved 11 February 1987
Accommodation/Occupational Safety
Issued 11 February 1987 Resolved
INSTALL VENT DUCTING ON E.R. EXHAUST BLOWER LEADING INTO BILGE.
Condition: Unknown
Due 11 February 1987
Resolved 11 February 1987
Engineering
Issued 11 February 1987 Resolved
REPAIR STBD. L.O. PRESSURE GAUGE IN MAIN CABIN AND ON FLYING BRIDGE.
Condition: Unknown
Due 11 February 1987
Resolved 11 February 1987
Engineering
Issued 11 February 1987 Resolved
REPAIR PORT TACHOMETER ON FLYING BRIDGE.
Condition: Unknown
Due 11 February 1987
Resolved 11 February 1987
Lifesaving
Issued 11 February 1987 Resolved
PROVIDE 10 ADULT AND 1 CHILD PFD'S TO BRING THE TOTALS TO 51 ADULTS AND 6 CHILDRENS.
Condition: Unknown
Due 11 February 1987
Resolved 11 February 1987
Documentation
Issued 18 February 1986 Resolved
PROVIDE EVIDENCE OF VALID FCC STATION AND OPERATOR LICENSE.
Condition: Unknown
Due 18 February 1986
Resolved 18 February 1986
Fire Fighting
Issued 18 February 1986 Resolved
LABEL PORT, STARBOARD, AND STERN EMERGENCY FUEL SHUT OFF LOCATIONS PROPERLY
Condition: Unknown
Due 18 February 1986
Resolved 18 February 1986
Lifesaving
Issued 18 February 1986 Resolved
REPLACE FRAYED LINE ON BUOYANT APPARATUS.
Condition: Unknown
Due 18 February 1986
Resolved 18 February 1986
Lifesaving
Issued 18 February 1986 Resolved
PROVIDE ONE ADULT PFD
Condition: Unknown
Due 18 February 1986
Resolved 18 February 1986
Documentation
Issued 11 February 1985 Resolved
PROVIDE AND POST ON BOARD VESSEL STABILITY LETTER.
Condition: Unknown
Due 11 February 1985
Resolved 11 February 1985
Accommodation/Occupational Safety
Issued 11 February 1985 Resolved
INSTALL CABLES IN SAFETY RAIL PORT AND STARBOARD AT BOARDING POSITIONS.
Condition: Unknown
Due 11 February 1985
Resolved 11 February 1985
Documentation
Issued 11 February 1985 Resolved
PROVIDE AND POST ON BOARD VESSEL'S F.C.C LICENSE.
Condition: Unknown
Due 11 February 1985
Resolved 11 February 1985
Lifesaving
Issued 11 February 1985 Resolved
PROVIDE AND INSTALL PROPER BREAK-LINK FOR BUOYANT APPARATUS (20 MAN SIZE)
Condition: Unknown
Due 11 February 1985
Resolved 11 February 1985
Engineering
Issued 11 February 1985 Resolved
INSTALL REMOTE REACH ROD ON STERN FUEL SHUT-OFF VALVE.
Condition: Unknown
Due 11 February 1985
Resolved 11 February 1985
Engineering
Issued 11 February 1985 Resolved
MARK STORAGE OF REMOTE FUEL SHUT-OFF ACCESS TOOLS
Condition: Unknown
Due 11 February 1985
Resolved 11 February 1985
Engineering
Issued 11 February 1985 Resolved
LABEL EMERGENCY FUEL SHUT-OFF FOR STERN FUEL TANK.
Condition: Unknown
Due 11 February 1985
Resolved 11 February 1985

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.