Records from 2016 to 2022. Most recent: inspection, 25 August 2022.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 4 May 2022
No resolution recorded
Missed hull and internal structures exam due 2022.
Action required: 701 - Prior to carriage of passengers/cargo
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 8 June 2021
Resolved
Port door is broken / wasted away. Repair / replace door.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 June 2021
Resolved 11 June 2021
Resolution: Door replaced in kind, all sat.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 13 July 2020
Resolved
Port side fire damper was found corroded and could not be closed in the event of a fire. Prove operation of vent closer.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 13 July 2020
Resolution: Cover removed, serviced, and tested sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 13 July 2020
Resolved
L/O Supply line to pressure gauge in wheelhouse is hose from the engine and connected to copper pipe. Hose and pipe are unsupported causing the hose and pipe vibrate excessively. Unsupported hose could fracture, causing L/O under pressure to spray in machinery space. Provide support for hose.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 13 July 2020
Resolution: Support provided.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 22 June 2020
Resolved
Make permanent repairs to leaking fire main piping.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 13 July 2020
Resolution: Fitting repaired and tested sat.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 18 September 2019
Resolved
Piping was the wrong type (PVC) and noted to be leaking during testing. Fire pump piping shall meet vital system requirements 182.40-5.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 November 2019
Resolution: Used copper piping and flexible wet exhaust hose SAE J1527.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 18 September 2019
Resolved
Provide a commercial grade garden hose for the fire pump, as per 181.15-10(e).
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 June 2020
Resolution: Provided and tested sat.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 18 September 2019
Resolved
Noted steady stream of water intrusion from the rudder post blocking, make effective repairs.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 June 2020
Resolution: Rudder block removed and renewed. U/W test sat.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 18 September 2019
Resolved
Repair the auto engine shut-down feature on the vesel's Fireboy fire extinguishing system. Shutdown was tested 3 times and did not secure the main engine.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 July 2020
Resolution: Cleaned ground wire to controler. System tested sat.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Ventilators, air pipes, casings
Issued 18 September 2019
Resolved
Repair/replace the plywood structure for the stbd engine room ventilation enclosure, wood rot noted.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 November 2019
Resolution: Replaced.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 18 September 2019
Resolved
Replace 02 handrails on teh Stbd & 1 port; wood rot was noted and hand rails were easily broken.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 June 2020
Resolution: Replaced with new.
09 - Working and Living Conditions › 092 - Working Conditions › Cleanliness of engine room
Issued 18 September 2019
Resolved
Remove excess oil from the engine room bilge.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 June 2020
Resolution: Oil removed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 18 September 2019
Resolved
Replace the supply keel cooler hose with the proper type (SAE J1527 or SAE 1942) type rigid, wire reinforced hose, utlizing double hose clamps. 182.40-5(b).
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 June 2020
Resolution: Replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 18 September 2019
Resolved
Replace the retro reflective tape on the ring buoy.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 November 2019
Resolution: Corrected.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 18 September 2019
Resolved
Repair the VHF radio installation; radio does not show the vsl's position. Connnect to a GPS unit or install a VHF radio with an internal GPS to comply with DSC requirements in 47 CFR 80.905.
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 July 2020
Resolution: New GPS intalled and interfaced with DSC Riado.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 19 September 2018
Resolved
Visual alarm indication for High Water Alarm for fwd. void was found inoperable. Prove proper operation of High Water Alarm visual indication prior to next operating season (spring 2019).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 April 2019
Resolved 18 September 2019
Resolution: Corrected
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 19 September 2018
Resolved
Vessel fire main shall be fitted to provide an effective stream of water from a single hoes. When tested fire hose stream would reach apx 2 feet with low water output. Proved effective water stream from fire hose prior to carrying passengers for hire.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 April 2019
Resolution: Installed new pump and tested sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 19 September 2018
Resolved
A single 12 volt starting battery was located in the passenger compartment unsecured and uncovered creating a hazardous condition from movement and spark for unprotected terminals. Secure and cover battery or remove from vessel prior to next operating season (spring 2019).
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 1 April 2019
Resolved 30 April 2019
Resolution: Battery removed.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 19 September 2018
Resolved
Vessel is fitted with (03) hatches exposed to the weather on the aft main deck. Hatches are required to be watertight to reduce flooding of vessel from down flooding. Hatches were found improperly serviced and not watertight. Prove watertight integrity of hatches prior to next operating season (spring 2019).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 April 2019
Resolved 30 April 2019
Resolution: Gaskets and fastners renewed.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 19 September 2018
Resolved
Fire hose is required to be of good commercial grade to prevent kinking. Fire hose was found warn and kinked. This condition restricts the flow of firefighting water. Provide commercial grade hose prior to next operating season (spring 2019).
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 1 April 2019
Resolved 30 April 2019
Resolution: Hose replaced.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 3 October 2017
Resolved
(02) Lifejackets were found unserviceable due to deterioration. Replace. Vessel limited to not more than 47 total passengers.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 13 October 2017
Resolution: Provided (02) Type I Lifejackets.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 3 October 2017
Resolved
Battery in ringbuoy light was found expired, replace with non-expired battery.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 October 2017
Resolved 3 October 2017
Resolution: Replaced with new.
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 3 October 2017
Resolved
Retroreflective material on (04) lifejackets was found worn, replace with new.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 October 2017
Resolved 3 October 2017
Documentation › Certificates/Documents › Certificate of Inspection
Issued 3 October 2017
Resolved
Certificate of Inspection is required to be posted for reference for the vessel master and passengers. Post certificate and all pages in area accessible to passengers.
Action required: 705 - Other - as specified
Due 13 October 2017
Resolved 13 October 2017
Resolution: Posted in main cabin.
Documentation › Certificates/Documents › Stability Letter
Issued 3 October 2017
Resolved
Stability Letter is required to be posted for reference for the vessel master [name withheld] Letter and all pages in operating station.
Action required: 705 - Other - as specified
Due 13 October 2017
Resolved 13 October 2017
Resolution: Posted in operating station
Communications › Radio Communications › VHF Radiotelephone
Issued 3 October 2017
Resolved
Vessel is outfitted with a DSC Radio. MMIS Number and GPS interface are not enabled per 47 CFR Part 80. Interface DSC Radio with MMIS Number and GPS.
Condition: Placed in Improper Service
Due 31 October 2017
Resolved 30 April 2018
Pollution Prevention/Response › Prevention Equipment › Sewage System Tank
Issued 3 October 2017
Resolved
Type III MSD Tank was found full and bulging on outboard sides indicating structural failure. Tank was also found to be unsecured from movement. Remove contents of tank and make repairs to original scantling and provide strapping to secure tank from movement.
Condition: Placed in Improper Service
Due 31 October 2017
Resolved 30 April 2018
Engineering › Bilge Water Management System › Piping
Issued 3 October 2017
Resolved
Bilge piping in fwd void is not suitably supported for service. Provide pipe support.
Action required: 705 - Other - as specified
Due 31 October 2017
Resolved 30 April 2018
Construction/Loadline › Penetrations › Pipe Flange
Issued 3 October 2017
Resolved
Cap unused overboard valve in fwd void to prevent inadvertent opening of valve and flooding of compartment.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 30 April 2018
Resolved 20 June 2018
Resolution: Cleared
Engineering › Steering Gear System › Hydraulic Hose
Issued 3 October 2017
Resolved
Steering system hoses in steering void are routed over frames and not protected against chafing. Provide means to prevent chafing of hoses.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 31 October 2017
Resolved 30 April 2018
Electrical › Electrical Distribution System (service) › Cable
Issued 3 October 2017
Resolved
Battery cables from port battery to main engine are routed over frames and not protected against chafing. Provide means to prevent chafing of battery cables.
Action required: 705 - Other - as specified
Due 31 October 2017
Resolved 30 April 2018
Engineering › Fuel Oil Service System › Valve, Control
Issued 3 October 2017
Resolved
Remote assembly for fuel tank shut was found loose. Tighten remote assembly to prevent disconnection.
Action required: 705 - Other - as specified
Due 13 October 2017
Resolved 30 April 2018
Engineering › Diesel Engine (propulsion-reduction gear) › Crankcase
Issued 3 October 2017
Resolved
Engine dipstick was lost and a coat hanger is used to determine engine oil level. Prove proper marking of oil level gauge in accordance with manufactures specifications.
Action required: 705 - Other - as specified
Due 31 October 2017
Resolved 30 April 2018
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 5 July 2016
Resolved
Certificate of Documentatin does not have fishery endorsement. Vessel engages in fishing charters.
Action required: 705 - Other - as specified
Due 5 August 2016
Resolved 14 September 2016
Resolution: Fishery endorsement was added on 8/6/2016.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 5 July 2016
Resolved
Red light was out, lens clarity hazy.
Action required: 705 - Other - as specified
Due 5 August 2016
Resolved 18 August 2016
Resolution: all Nav lights were Sat.
Engineering › Diesel Engine (propulsion-direct drive) › Emergency shutdown
Issued 5 July 2016
Resolved
Engine Shutdown inoperable.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 July 2016
Resolution: Vessel appropriately rewired Fireboy/engine emergency shutdown and demonstrated proper operation.
Construction/Loadline › Structures › Superstructure
Issued 5 July 2016
Resolved
Gunwhale board on starboard side IVO embarkation repair/replace to good wood approximately 8 feet in length
Due 5 August 2016
Resolved 18 August 2016
Resolution: All repairs were SAT.
Construction/Loadline › Hull › Stringer
Issued 5 July 2016
Resolved
Port Aft bilge stringer pulled frame. Complete fastener repair proposal for affected area.
Due 30 November 2016
Resolved 22 November 2016
Resolution: Repair completed to bilge stringer, all sat.