← All vessels
LADY MARIA
Freight Ship · Bulk Carrier class · Built 1980s · USCG East District (CGD-E) · Other hulls named LADY MARIA
LADY MARIA is a 1985 freight ship. The Coast Guard has recorded 12 inspections since 1986, most recently in April 2002, along with 17 deficiencies and 1 operational control.
Records from 1986 to 2002. Most recent: inspection, 28 April 2002.
- Built
- 1985
- Last inspected
- 28 April 2002
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 17 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
8500070 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
Y2JQ
455399
Flag
ANTIGUA AND BARBUDA
—
Maury page id
psix-455399
Inspections, by type
The 12 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 24 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.
Documentation record
Tonnage as PSIX records it3120 - Regulatory (Subpart C or D), Gross Ton
1088 - Regulatory (Subpart C or D), Net Ton
3650 - Dead Weight, Ton
1088 - Regulatory (Subpart C or D), Net Ton
3650 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 12
28 April 2002
Annual Inspection · Ballast Water Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1609316
12 July 2000
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 279833
17 April 2000
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 276864
3 March 2000
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 275443
20 February 1998
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 483688
15 February 1998
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 29390
16 July 1997
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 405867
4 June 1997
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 404326
1 May 1997
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 402956
6 June 1993
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 458659
6 June 1989
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 330811
8 October 1986
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 312150
Deficiency record · 17
Documentation › Certificates/Documents › International Load Line Certificate
Issued 28 April 2002
Resolved
BA01--- HAVE AGENT FAX COPY OF NEW INTERNATIONAL LOAD LINE CERTIFICATE. CLASS SURVEYOR WAS ON BOARD AT TIME OF INSPECTION AND WOULD BE ISSUING A NEW ONE.
Fire Fighting › Means of Escape › Doorways
Issued 28 April 2002
Resolved
ALL FIREDOORS IN STAIRWAYS/HALLWAYS ARE NOT SELF-CLOSING AND HAVE HOLD BACK DEVICES NOT OAW THE FIRE CONTROL PLAN. IAW SOLAS 74(A) CH II-2 REG 46.1 AND 47.2, REMOVE HOLD BACK DEVICES AND INSTALL SELF-CLOSING DEVICES TO THE SATISFACTION OF THE SAFETY CONSTRUCION CERTIFICATE ISSUING AUTHORITY.
Deck/Cargo
Issued 28 April 2002
Resolved
BA03--- MISCELLANEOUS THROUGHPUT STBD SIDE LADDER ACCESS TO BOSN'S HOLE NEEDS REPLACEMENT OF GASKET. REMOVE GARBAGE BAG THAT IS ON TOP- MAKING IN WEATHERTIGHT.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 28 April 2002
Resolved
BA04--- OWS INOPERATIVE. PROVE OPERATION OF SYSTEM TO THE SATISFACTION OF CLASS SOCIETY SURVEYOR.
Fire Fighting › Fire Pumps
Issued 28 April 2002
Resolved
BA05--- BILGE & FIRE PUMPS LEAKING EXCESSIVELY INTO BILGES. REPAIR TO THE SATISFACTION OF COAST GUARD MARINE INSPECTOR.
Engineering
Issued 3 March 2000
Resolved
PROVE PROPER OPERATION OF THE OILY WATER SEPARATOR EQUIPMENT INCLUDING ALARMS IN ACCORDANCE WITH MARPOL 73/78 ANNEX 1/16(7) TO THE SATISFACTION OFTHE CERTIFICATE ISSUEING AUTHORITY BUT NO LATER THAN 03APR00. ALL OILY SLOPS/WASTES TO BE MAINTAINED ON BOARD UNTIL REQUIREMENT SATISFIED.
Documentation
Issued 3 March 2000
Resolved
PROVIDE SHIPBOARD OIL POLLUTION EMERGENCY PLAN IN ACCORDANCE WITH 33 CFR 151.29 PRIOR TO DEPARTURE FROM U.S. WATERS AND TO THE SATISFACTION OF THE CERTIFICATE ISSUEING AUTHORITY.
Lifesaving
Issued 3 March 2000
Resolved
REPAIR WATERLIGHT ON RING BUOY LOCATED ON STARBOARD SIDE AFT ON DECK "A" TOTHE SATISFACTION OF THE CERTIFICATE ISSUEING AUTHORITY BUT NO LATER THAN 03APR00.
Documentation
Issued 3 March 2000
Resolved
PROVIDE MAINTENCE MANUAL FOR LIFESAVING IN ACCORDANCE WITH SOLAS 74 AMENDEDIII/19.3 TO THE SATISFACTION OF THE CERTIFICATE ISSUEING AUTHORITY BUT NO LATER THAN 03APR00.
Navigation
Issued 3 March 2000
Resolved
PROVIDE RUDDER ANGLE INDICATOR AT EMERGENCY STEERING STATION IN ACCORDANCE WITH SOLAS 74 AMENDED II-1/11.2 TO THE SATISFACTION OF THE CLASSIFICATION SOCIETY BUT PRIOR TO DEPARTURE FROM U.S. WATERS.
Navigation
Issued 3 March 2000
Resolved
PROVIDE UPDATED CHARTS IN ACCORDANCE WITH 33 CFR 164.33 PRIOR TO DEPARTURE FROM U.S. WATERS.
Fire Fighting
Issued 3 March 2000
Resolved
PROVE PROPER OPERATION OF EMERGENCY FIRE PUMP PRIOR TO CONDUCTING CARGO OPERATIONS IN ACCORDANCE WITH SOLAS 74 AMENDED II-2/4.
Documentation
Issued 3 March 2000
Resolved
PROVIDE SOLAS TRAINING MANUAL FOR LIFESAVING IN ACCORDANCE WITH SOLAS 74 AMMENDED III/18.2 TO THE SATISFACTION OF THE CERTIFICATE ISSUEING AUTHORITYBUT NO LATER THAN 03APR00.
Lifesaving
Issued 1 May 1997
Resolved
DIMENSIONS & NUMBER OF PERSONS NOT STENCILED ON LIFE BOATS.
Navigation
Issued 1 May 1997
Resolved
EMERGENCY STEERING INSTRUCTIONS MISSING ON BRIDGE.
Construction/Loadline
Issued 1 May 1997
Resolved
NAME OF VESSEL ON STERN IS NOT LEGIBLE.
Documentation
Issued 6 June 1989
Resolved
VESSEL'S HAD NO BUNKER OIL TRANSFER PROCEDURES ON BOARD.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.