Records from 1997 to 1999. Most recent: inspection, 25 August 1999.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 6
25 August 1999
Hull Examination · COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1450343
25 September 1998
Administrative
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1102704
30 March 1998
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 786730
20 August 1997
Administrative
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 784418
25 July 1997
Hull Examination · Initial Certification · Inclining Experiment
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1117312
15 May 1997
Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1113984
Documentation
Issued 25 July 1997
Resolved
PROVIDE ON BOARD A VALID COPY OF FCC RADIO STATION LICENSE AND SAFETY CERTIFICATE.
Condition: Unknown
Due 25 July 1997
Resolved 25 July 1997
Navigation
Issued 25 July 1997
Resolved
DEMONSTRATE PROPER OPERATION OF NAVIGATION EQUIPMENT INCLUDING VHF RADIO.
Condition: Unknown
Due 8 August 1997
Resolved 8 August 1997
Electrical
Issued 25 July 1997
Resolved
PROVIDE ELECTRICAL LINE DIAGRAM W/ LOAD ANALYSIS.
Condition: Unknown
Due 8 August 1997
Resolved 8 August 1997
Electrical
Issued 25 July 1997
Resolved
DEMONSTRATE OPERATION OF S/S GENERATOR.
Condition: Unknown
Due 8 August 1997
Resolved 8 August 1997
Electrical
Issued 25 July 1997
Resolved
PROPERLY INSTALL BATTRIES AND BATTERY BOXES.
Condition: Unknown
Due 8 August 1997
Resolved 8 August 1997
Electrical
Issued 25 July 1997
Resolved
PROVIDE TWO HAND HELD EMERGENCY LIGHTS
Condition: Unknown
Due 8 August 1997
Resolved 8 August 1997
Lifesaving
Issued 25 July 1997
Resolved
PROVIDE 2 ADDITIONAL ORANGE HAND HELD FLARES.
Condition: Unknown
Due 8 August 1997
Resolved 8 August 1997
Documentation
Issued 25 July 1997
Resolved
PROVIDE PROOF OF RANDOM DRUG TESTING ENROLLMENT
Condition: Unknown
Due 8 August 1997
Resolved 8 August 1997
Fire Fighting
Issued 25 July 1997
Resolved
PRIOR TO 30SEP97,INSTALL STRUCTURAL FIRE PROTECTION FOR MACHINERY SPACE IN ACCORDANCE WITH 46CFR180 AND 46CFR160.009
Condition: Unknown
Due 25 July 1997
Resolved 25 July 1997
Documentation
Issued 25 July 1997
Resolved
PROVIDE PROOF OF USER FEE PAYMENT.
Condition: Unknown
Due 25 July 1997
Resolved 25 July 1997
Lifesaving
Issued 25 July 1997
Resolved
PROVIDE ON BOARD A LIFE JACKET INSTRUCTION PLACARD.
Condition: Unknown
Due 8 August 1997
Resolved 8 August 1997
Electrical
Issued 25 July 1997
Resolved
COMPLETE INSTALLATION OF ELECTRICAL SYSTEM.
Condition: Unknown
Due 8 August 1997
Resolved 8 August 1997
Lifesaving
Issued 25 July 1997
Resolved
PROVIDE RETRO-REFLECTIVE TAPE ON RING BOUY.
Condition: Unknown
Due 8 August 1997
Resolved 8 August 1997
Fire Fighting
Issued 25 July 1997
Resolved
PROVIDE ONBOARD 2 ADDITIONAL BII FIRE EXTINGUISHERS.
Condition: Unknown
Due 8 August 1997
Resolved 8 August 1997
Fire Fighting
Issued 25 July 1997
Resolved
COMPLETE INTALLATION OF FIXED HALON SYSTEM CONTROLS.
Condition: Unknown
Due 8 August 1997
Resolved 8 August 1997
Construction/Loadline
Issued 25 July 1997
Resolved
DEMONSTRATE OPERATION OF BILGE PUMPS AND BILGE HIGH LEVEL ALARMS.
Condition: Unknown
Due 8 August 1997
Resolved 8 August 1997