Records from 1982 to 2014. Most recent: inspection, 8 October 2014.
Inspection history · 79
8 October 2014
Administrative Inspection · Loadline Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5000983
1 June 2012
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4330896
9 November 2010
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3960477
30 December 2009
Hull Examination · Internal Structural Exam
Physical examination · Activities Europe · Activity 3656636
5 November 2008
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3357631
29 October 2008
Administrative Inspection · MTSA/ISPS Verification · Annual Inspection · MARPOL Annex II Examination · Deficiency Check
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3358242
15 February 2008
Underwater Inspection in lieu of Drydock · Drydock Extension · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3148003
13 December 2007
MTSA/ISPS Verification · Deficiency Check · MARPOL Annex II Examination · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3114940
29 January 2007
Examination of Repairs · Deficiency Check · MTSA/ISPS Verification · COI Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2863593
24 January 2006
Construction Oversight · MTSA/ISPS Verification · Re-Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2568039
11 January 2005
Hull Examination · MTSA/ISPS Verification · Internal Structural Exam · Annual Inspection · Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2285825
14 June 2004
In-Service Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2098424
5 January 2004
Re-Inspection · MARPOL Annex I Examination · Examination of Repairs
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1976035
16 December 2003
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1981931
2 June 2003
Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1808113
6 December 2002
Internal Structural Exam · Re-Inspection · MARPOL Annex I Examination · Underwater Inspection in lieu of Drydock
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1714448
20 June 2002
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1633658
12 May 2002
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1616299
21 February 2002
Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1491834
16 January 2002
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1478865
4 April 2001
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1410523
18 October 2000
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1056801
17 October 2000
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 823880
7 October 2000
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 53451
16 June 2000
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1437722
15 March 2000
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 816534
10 February 2000
Inclining Experiment
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1046028
21 January 2000
Hull Examination · COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1401175
21 January 2000
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1405013
27 June 1999
Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1081516
17 March 1999
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1458608
29 November 1998
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 37163
15 June 1998
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1394986
28 May 1997
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1463288
18 April 1997
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1385971
14 August 1996
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1086676
31 July 1996
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1087620
9 June 1996
Hull Examination · Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1360578
10 November 1995
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 165613
5 October 1995
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1184644
7 July 1995
COI Inspection · Examination of Repairs · Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1465809
26 June 1995
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1189388
6 March 1995
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1167523
16 November 1994
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 865150
7 October 1994
Examination of Repairs
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1417720
9 September 1994
Deadweight Survey
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1180085
2 May 1994
Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1405496
8 March 1993
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1370550
13 June 1992
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 180164
5 June 1992
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 170552
28 May 1992
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1269545
8 April 1992
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1391758
24 October 1991
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1246126
11 July 1991
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 939694
18 April 1991
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 934607
14 March 1991
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 996511
26 February 1991
Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 913974
16 March 1990
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 931266
9 September 1989
Deficiency Check · Examination of Repairs
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1206710
1 September 1989
Damage Survey
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 888773
21 March 1989
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1273184
22 November 1988
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1194384
24 August 1988
Examination of Repairs
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1350877
9 August 1988
Hull Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1201833
29 July 1988
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1208573
8 April 1988
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1033251
30 March 1987
COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1004551
29 January 1987
Administrative
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1002391
15 April 1986
Re-Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1298923
17 July 1985
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 979702
2 April 1985
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 977962
28 February 1985
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 977826
30 January 1985
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1285744
5 October 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 975399
28 September 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 975398
16 March 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 973434
9 February 1983
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 965085
8 April 1982
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1277437
16 February 1982
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1271379
Stability › Watertight Integrity › General
Issued 29 October 2008
Resolved
PVC piping into water tanks did not have metallic valves prior to penetrating watertight bulkheads. Install metallic valves in pvc piping.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 31 October 2008
Resolution: Valves installed.
Electrical › Electrical Distribution System (service) › Panelboard
Issued 29 October 2008
Resolved
2 panelboards in A/C room had broken latches. Repair latches.
Due 31 October 2008
Resolved 31 October 2008
Resolution: Panel latches repaired.
Stability › Watertight Integrity › General
Issued 13 December 2007
Resolved
Vessel has several PVC pipes going through watertight bulkheads. The vessel shall install metallic valves on both sides of bulkhead or single valve to be remotely actuated.
Due 19 December 2007
Resolved 14 December 2007
Resolution: Valves installed correctly.
Lifesaving › Inflatable Liferafts › Hydrostatic Release Unit
Issued 29 January 2007
Resolved
Hydro releases connected incorrectly.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 January 2007
Engineering › Electric Propulsion System › Wiring
Issued 21 February 2005
Resolved
Provide ABS approval for new D.P. system.
Due 21 March 2005
Resolved 17 February 2006
Engineering › Electric Propulsion System › Wiring
Issued 21 February 2005
Resolved
Provide ABS approval for installation of new D.P. system.
Due 21 March 2005
Resolved 17 February 2006
Lifesaving › Rescue Boat › Construction
Issued 21 February 2005
Resolved
Provide Coast Guard approved plans for the installation and location of the new rescue boat and davit.
Due 21 March 2005
Resolved 2 May 2005
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 21 February 2005
Resolved
Provide Coast Guard approved Fire Control Plan for the vessel.
Due 21 March 2005
Resolved 17 February 2006
Electrical › Electric Generation Source (service) › Generator
Issued 21 February 2005
Resolved
Prove machinery safeties (low lube oil, over speed, reverse power relay) on ALCO generators, with ABS surveyor in attendance.
Due 21 March 2005
Resolved 3 March 2005
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 21 February 2005
Resolved
Prove aft anchor light provides 360 degree visibility, as per navigational rules (rule 30, lights and shapes).
Due 21 March 2005
Resolved 3 March 2005
Lifesaving › Rescue Boat › Hull (rigid)
Issued 21 February 2005
Resolved
Prove proper operation of new rescue boat davit (including quick release, nitrogen bottle charge and proper securing straps) with ABS or Coast Guard Inspector in attendance.
Due 21 March 2005
Resolved 3 March 2005
Engineering › Bilge Water Management System › Piping
Issued 11 January 2005
Resolved
Provide ABS approval for installation of Tank Level Indicator System.
Due 21 March 2005
Resolved 3 March 2005
Electrical › Lighting (service)
Issued 5 January 2004
Resolved
Numerous bunk lights missing bulbs throughout accomadation spaces. LEGACY COMPONENT DESC: Lighting Fixture
Condition: Improper/Lack of Maintenance
Due 6 January 2004
Resolved 6 January 2004
Resolution: bulbs replaced.
Accommodation/Occupational Safety › Occupational Safety
Issued 5 January 2004
Resolved
Numerous smoke detectors in accomodation spaces were inoperable. Instructed vsl rep to repair/replace them. LEGACY COMPONENT DESC: Smoking
Condition: Improper/Lack of Maintenance
Due 6 January 2004
Resolved 6 January 2004
Resolution: Replaced batteries in smoke detectors.
Lifesaving › Lifebuoys
Issued 5 January 2004
Resolved
Retro was in need of repair.
Condition: Improper/Lack of Maintenance
Due 6 January 2004
Resolved 6 January 2004
Resolution: Retro replaced.
Lifesaving › Inflatable Liferafts › Hydrostatic Release Unit
Issued 5 January 2004
Resolved
Hydro. release was installed upside down.
Condition: Improper Installation
Due 6 January 2004
Resolved 6 January 2004
Resolution: Installed properly.
Fire Fighting › Nozzles › Condition
Issued 5 January 2004
Resolved
Nozzle chains missing on three nozzles.
Condition: Improper/Lack of Maintenance
Due 6 January 2004
Resolved 6 January 2004
Resolution: Provided chains.
Engineering › Compressed Air System (control) › Valve
Issued 5 January 2004
Resolved
Hand lift device missing on relief valve.
Condition: Improper/Lack of Maintenance
Due 6 January 2004
Resolved 6 January 2004
Resolution: Provided lifting device.
Accommodation/Occupational Safety › Refrigeration (air conditioning)
Issued 5 January 2004
Resolved
Repair soft patch in A/C room.
Condition: Improper/Lack of Maintenance
Due 6 January 2004
Resolved 6 January 2004
Resolution: repaired soft patch.
Accommodation/Occupational Safety › Potable Water System
Issued 5 January 2004
Resolved
Soft patch on hot water system.
Condition: Improper/Lack of Maintenance
Due 6 January 2004
Resolved 6 January 2004
Resolution: Removed asbestos from line, and replaced line.
Fire Fighting › Means of Escape › Corridors
Issued 5 January 2004
Resolved
Obstruction to scr escape hatch.
Condition: Improper/Lack of Maintenance
Due 6 January 2004
Resolved 6 January 2004
Resolution: Removed obstructions.
Engineering › Fuel Oil Service System › Filter
Issued 5 January 2004
Resolved
No plugs were installed in petcocks for fuel filters.
Condition: Improper Installation
Due 6 January 2004
Resolved 6 January 2004
Resolution: Installed plugs.
Stability › Watertight Integrity
Issued 5 January 2004
Resolved
WTD gasket needs to be replaced.
Condition: Improper/Lack of Maintenance
Due 6 January 2004
Resolved 6 January 2004
Resolution: Replaced gasket.
Engineering › Pressure Vessel
Issued 16 January 2002
Resolved
air receivers, as listed on COI, to have relief valves tested and/or adjusted and installed. LEGACY COMPONENT DESC: Relief Valve
Due 25 February 2002
Resolved 21 February 2002
Resolution: All pressure vessel relief valves tested and/or adjusted to relieve at proper settings and installed on air receivers listed on COI. Valves tested by New Aquatrol, Inc., and certificate presented to attending marine inspector''s satisfaction.
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 16 January 2002
Resolved
provide proof of satisfactory test of 20 second time delay for generator room system LEGACY COMPONENT DESC: Operating Controls
Due 25 February 2002
Resolved 21 February 2002
Resolution: A copy of Fire Protection Services function test of the generator room CO2 system conducted on 08 Feb confirms satisfactory performance of time delay. Copy of report provided to marine inspector''s satisfaction.
Fire Fighting › Fixed Deck Foam System
Issued 16 January 2002
Resolved
provide foam analysis report
Due 25 February 2002
Resolved 21 February 2002
Resolution: A copy of the foam analysis for foam samples taken from the engine room and helideck foam systems were provided to the marine inspector, and the report confirms that the foam is within specifications.
Accommodation/Occupational Safety › Ventilation
Issued 16 January 2002
Resolved
make satsfactory permanent repair to laundry dryer vent with metallic components.
Due 25 February 2002
Resolved 21 February 2002
Resolution: Metallic flex exhaust tubing was installed, and photographs of the installation were provided to the marine inspector''s satisfaction.
Unknown
Issued 21 January 2000
Resolved
PRIOR TO MANNED OPERATIONS, PROPERLY DEMONSTRATE THE FOLLOWING DRILLS TO CGINSPECTORS:_x001C_ RESCUE BOAT LAUNCHING AND RECOVERY (MAN OVERBOARD), FIRE FIGHTING, AND ABANDON SHIP._x001C_
Condition: Unknown
Due 21 January 2000
Resolved 21 January 2000
Unknown
Issued 21 January 2000
Resolved
PROPERLY DEMONSTRATE THE REVERSE POWER RELAY ON #2 GENERATOR._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 21 January 2000
Resolved 21 January 2000
Unknown
Issued 21 January 2000
Resolved
PROVIDE THE FOLLOWING VALID DOCUMENTATION:_x001C_ NEW ABS LOADLINE CERTIFICATE AND STABILITY LETTER._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 21 January 2000
Resolved 21 January 2000
Unknown
Issued 21 January 2000
Resolved
CLEARLY MARK THE DIRECTIONS TO EMERGENCY ESCAPE ROUTES INTERNALLY THROUGHOUT THE VESSEL.
Condition: Unknown
Due 21 January 2000
Resolved 21 January 2000
Lifesaving
Issued 18 April 1997
Resolved
CONNECT GENERAL ALARM BELLS IN ALCO MACHINERY ROOM.
Condition: Unknown
Due 18 April 1997
Resolved 18 April 1997
Engineering
Issued 14 August 1996
Resolved
01. USE OF BOILER NOT AUTHORIZED UNTIL COMPLETION OF TUBE REPAIRS TO THE SATISFACTION OF ATTENDING CG MARINE INSPECTOR.
Condition: Unknown
Due 14 August 1996
Resolved 14 August 1996
Engineering
Issued 9 June 1996
Resolved
REPAIR LOOSE/CRACKED REFRACTORY AROUND BOTH BURNER CANS/ACCESS DOORS OF BOILER.
Condition: Unknown
Due 9 June 1996
Resolved 9 June 1996
Engineering
Issued 9 June 1996
Resolved
REPAIR LEAKING FIRE TUBE IN BOILER. CONDUCT ANNUAL HYDRO TEST IN PRESENCE OF C.G. INSPECTOR.
Condition: Unknown
Due 9 June 1996
Resolved 9 June 1996
Construction/Loadline
Issued 9 June 1996
Resolved
RENEW/REINSTALL BILGE SUCTION STRAINER IN FOLLOWING VOIDS: 1A, 1C, 2E, 3A, 4A,13A.
Condition: Unknown
Due 9 June 1996
Resolved 9 June 1996
Accommodation/Occupational Safety
Issued 9 June 1996
Resolved
PROVIDE APPROVED DRAWINGS OR REMOVE PIPING FROM MSD DISCHARGE TO VOID 6D.
Condition: Unknown
Due 9 June 1996
Resolved 9 June 1996
Documentation
Issued 9 June 1996
Resolved
PROVIDE APPROVED DRAWINGS FOR 1) FUEL OIL PURIFIER PIPING TO P&S FUEL_x001C_ TANKS. 2) NEW SALTWATER SERVICE PUMP IN FWD PUMP ROOM. 3) ADDITION TO MAINDECK ABOVE S/W BALLAST TANKS 10K,11F,12G.
Condition: Unknown
Due 9 June 1996
Resolved 9 June 1996
Fire Fighting
Issued 9 June 1996
Resolved
PROVIDE CURRENT FIREFIGHTING FOAM ANALYSIS REPORT.
Condition: Unknown
Due 9 June 1996
Resolved 9 June 1996
Electrical
Issued 9 June 1996
Resolved
PROVE PROPER OPERATION OF REVERSE CURRENT RELAY FOR GENERATOR #2.
Condition: Unknown
Due 9 June 1996
Resolved 9 June 1996
Engineering
Issued 9 June 1996
Resolved
PROVE PROPER OPERATION OF BOILER CONTROLS AND SAFETIES IN PRESENCE OF C.G. INSPECTOR.
Condition: Unknown
Due 9 June 1996
Resolved 9 June 1996
Documentation
Issued 9 June 1996
Resolved
PROVIDE 5YR/POST DISMASTING EXAMINATION/TEST REPORT FOR VESSELS DERRICK BY RECONIZED ORIGANIZATION OR ASSOCIATION.
Condition: Unknown
Due 9 June 1996
Resolved 9 June 1996
Accommodation/Occupational Safety
Issued 9 June 1996
Resolved
CROP+RENEW WASTED HELO DECK SAFETY NET FRAMING. TEST COMPLETED REPAIRS
Condition: Unknown
Due 9 June 1996
Resolved 9 June 1996
Electrical
Issued 9 June 1996
Resolved
RENEW EMERGENCY BATTERY INSTALLATION IN ACCORDANCE WITH 46 CFR 111.15.
Condition: Unknown
Due 9 June 1996
Resolved 9 June 1996
Fire Fighting
Issued 9 June 1996
Resolved
PROVIDE APPROVED FIRE AND SAFETY PLAN REFLECTING CURRENT VESSEL/EQUIPMENT CONFIGURATION ONBOARD.
Condition: Unknown
Due 9 June 1996
Resolved 9 June 1996
Fire Fighting
Issued 9 June 1996
Resolved
PROVIDE PROPER NON CONDUCTIVE GLOVES FOR BOTH FIREMANS OUTFITS ONBOARD.
Condition: Unknown
Due 9 June 1996
Resolved 9 June 1996
Lifesaving
Issued 7 July 1995
Resolved
SUBMIT TO [name withheld] FOR APPROVAL OF RESCUE BOAT MEETING THEINTENT OF SOLAS CHAPT III, REG 47.1. DEPLOYMENT AND RECOVERY SHALL BE DEMONSTRATED TO SATISFACTION OF ATTENDING COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 18 July 1995
Resolved 18 July 1995
Engineering
Issued 16 November 1994
Resolved
INSPECTION, REPAIR, TESTING, INSTALLATION OF REPLACEMENT BOILER TO THE SATISFACTION OF ASME AUTHORIZED INSPECTOR AND ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 16 November 1994
Resolved 16 November 1994
Engineering
Issued 7 October 1994
Resolved
MAKE PERMANENT REPAIRS TO AUX FIRE TUBE BOILER S-4056 AT BOTTOM OF FRONT_x001C_ TUBE SHEET TO THE SATISFACTION OF THE COGNIZANT OCMI.
Condition: Unknown
Due 22 November 1994
Resolved 22 November 1994
Fire Fighting
Issued 8 April 1992
Resolved
Install proper brackets at fire extinguisher stations 1, 30,& 32 to the satisfaction of the attending Coast Guard marine inspector.
Condition: Unknown
Due 8 April 1992
Resolved 8 April 1992
Engineering
Issued 8 April 1992
Resolved
Prior to placing in service, prove proper operation of auxiliary boiler safety valves, safety shutdowns, & limit switches to the satisfaction of the attending Coast Guard marine inspector.
Condition: Unknown
Due 8 April 1992
Resolved 8 April 1992
Electrical
Issued 8 April 1992
Resolved
Renew stuffing tubes to explosion-proof lights in paint locker with type suitable for Class 1 Div.1 space to the satisfaction of the attending CoastGuard marine inspector. (Circuit to remain secured/tagged pending correction.)
Condition: Unknown
Due 8 April 1992
Resolved 8 April 1992
Lifesaving
Issued 14 March 1991
Resolved
COMPLETE WORKLIST ITEMS ISSUED BY MSO MORGAN CITY ON 14 MARCH 1991
Condition: Unknown
Due 1 May 1991
Resolved 31 July 1991
Engineering
Issued 14 March 1991
Resolved
PERFORM FIRETUBE BOILER AUTOMATION FUNCTION TESTS AND SET SAFETY RELIEF VALVES IN PRESENCE OF USCG MARINE INSPECTOR. BOILER NOT TO BE FIRED PENDING THIS INSPECTION.
Condition: Unknown
Due 1 May 1991
Resolved 31 July 1991
Unknown
Issued 1 September 1989
Resolved
MAKE REPAIR IN WAY OF VOID NO. 2B ALL DAMAGES; 3 LONG FRAMES, ONE VERTICALFRAME, CROP OUT DAMAGE FORWARD WTBD, REPAIR AND NDT, AND CROP AND REPAIR APPROXIMATELY 20' X 30' SHELL PLATES AND NDT SAME.
Condition: Unknown
Due 1 September 1989
Resolved 1 September 1989
Unknown
Issued 1 September 1989
Resolved
MAKE REPAIR IN WAY OF VOID NO. 1A ALL DAMAGES: 3 LONG FRAMES AND CROP OUT APPROXIMATELY 20' OF FIRST TRANSVERSE FRAME. NOTE: SHELL PLATES ON ITEM NO. 1 EXTEND TO THIS COMPARTMENT.
Condition: Unknown
Due 1 September 1989
Resolved 1 September 1989
Engineering
Issued 24 August 1988
Resolved
MAKE VESSEL AVAILABLE FOR FOLLOW-UP EXAM OF AUXILIARY BOILER DUE TO FRACTURE REPAIRS IN WAY OF LOWER SHELL AND HEADER AT FORWARD END. ADDITIONAL NON-DESTRUCTURE TESTING WILL BE REQUIRED DURING THIS EXAM.
Condition: Unknown
Due 24 August 1988
Resolved 24 August 1988
Engineering
Issued 24 August 1988
Resolved
PROVIDE RESULTS OF AUXILIARY BOILER PLATE ANALYSIS TO DETERMINE EXTENT OF HARDENING AND POTENTIAL FOR DEVELOPING ADDITIONAL FRACTURES. PURPOSE CORRECTIVE MEASURES, IF FOUND NECESSARY.
Condition: Unknown
Due 24 August 1988
Resolved 24 August 1988
Documentation
Issued 24 August 1988
Resolved
INSURE THAT REPAIR CONTRACTOR (GULF ENGINEERING CO., INC) PROVIDES COPIES OF APPROVED WELDING PROCEDURES AND WELDER QUALIFICATION RECORDS APPLICABLE TO AUXILIARY BOILER REPAIR PERFORMED 23AUG88.
Condition: Unknown
Due 24 August 1988
Resolved 24 August 1988
Documentation
Issued 29 July 1988
Resolved
OBTAIN APPR FROM THE MSC FOR INSTALL. DWGS OF REPL. BOILER INCL. PIPING ARRGMT/COMPONENTS; ELEC'L CKTS AND CONN. MADE ON VSL; FIELD MOD TO UPGRADE CONTROL/MONITOR/ALARM CKTS. PREV. APPR DWGS SHOULD BE REF FOR EQUIP NOT CHANGED.
Condition: Unknown
Due 29 July 1988
Resolved 29 July 1988
Accommodation/Occupational Safety
Issued 28 February 1985
Resolved
TANK 9E: REPLACE LADDER SUPPORT.
Condition: Unknown
Due 28 February 1985
Resolved 28 February 1985
Construction/Loadline
Issued 28 February 1985
Resolved
TANK 5A: PICK UP FIVE (5) WELDS (MARKED).
Condition: Unknown
Due 28 February 1985
Resolved 28 February 1985
Construction/Loadline
Issued 28 February 1985
Resolved
TANK 12A: (A) REPLACE #2,#3, AND #5 BRACKETS ON SIDE SHELL. (B) GAUGE AND WELD #2 STBD TRANSOM VERTICAL AT BUTT JOINT. (C) REPLACE GUSSETS #4, #5, AND #6 ON PORT SIDE OF TANK AFT OF LADDER.
Condition: Unknown
Due 28 February 1985
Resolved 28 February 1985
Construction/Loadline
Issued 28 February 1985
Resolved
TANK 2E: (A) REPLACE DISTORTED BRACKETS AND GUSSETS (2 EACH). (B) REPLACE 4 FT OF #1 AND #2 SIDE LONGS.
Condition: Unknown
Due 28 February 1985
Resolved 28 February 1985
Construction/Loadline
Issued 28 February 1985
Resolved
TANK 3D: REPLACE #1 DIAGONAL BRACKET.
Condition: Unknown
Due 28 February 1985
Resolved 28 February 1985
Construction/Loadline
Issued 28 February 1985
Resolved
TANK 8A: PICK UP FIVE (5) WELDS (MARKED).
Condition: Unknown
Due 28 February 1985
Resolved 28 February 1985
Construction/Loadline
Issued 28 February 1985
Resolved
TNAK 10K: (A) REPLACE 40 FT OF #5 SIDE LONG. (B) REPLACE 100 SQ FT OF RAMP DECK WHICH IS WASTED.
Condition: Unknown
Due 28 February 1985
Resolved 28 February 1985
Construction/Loadline
Issued 28 February 1985
Resolved
TNAK 11F: UPPER SECTION-(A) REPLACE #2 TRANSOM VERTICAL AND HORIZONTAL SUPPORT. (B) REPLACE 15 FT OF #1 SIDE LONG AND ATTACHED CORNER BRACKET.
Condition: Unknown
Due 28 February 1985
Resolved 28 February 1985
Construction/Loadline
Issued 28 February 1985
Resolved
TANK 12G: UPPER SECTION-(A) REPLACE #2 VERTICAL FLANGE STIFFENER AND TRIPPING BRACKET. (B) REPLACE 5 FT OF #1 AND #2 SIDE LONGS.
Condition: Unknown
Due 28 February 1985
Resolved 28 February 1985
Construction/Loadline
Issued 28 February 1985
Resolved
TANK 12G: LOWER SECTION-(A) REPLACE 16 FT OF #2,#3, AND #4 SIDE LONGS. (B) REPLACE 10'X6"X16' SECTION OF SIDE SHELL IN WAY OF #2,#3, AND #4 SIDE LONGS.
Condition: Unknown
Due 28 February 1985
Resolved 28 February 1985
Unknown
Issued 30 January 1985
Resolved
THE FOLLOWING DEFICIENCY PERTAINS TO MCDERMOTT DERRICK BARGE NO.16,
Condition: Unknown
Due 30 January 1985
Resolved 30 January 1985
Unknown
Issued 30 January 1985
Resolved
TEST AND SET SAFETIES AND HYDRO BOILERS.
Condition: Unknown
Due 30 January 1985
Resolved 30 January 1985
Electrical
Issued 28 September 1984
Resolved
PROPERLY SECURE AND LABEL ALL NEW ELECTRICAL WIRE INSTALLATIONS.
Condition: Unknown
Due 28 September 1984
Resolved 28 September 1984
Electrical
Issued 28 September 1984
Resolved
ADJUST THE OVERSPEED TRIP ON THE EMERGENCY GENERATOR BETWEEN 10% AND 15% THE RATED RPM.
Condition: Unknown
Due 28 September 1984
Resolved 28 September 1984
Lifesaving
Issued 28 September 1984
Resolved
PROPERLY STENCIL THE DAY TANK EMERGENCY FUEL SHUT OFF AND PROPERALY STENCILALL NEW EMERGENCY LIGHTS.
Condition: Unknown
Due 28 September 1984
Resolved 28 September 1984
Unknown
Issued 8 April 1982
Resolved
Unknown Component - Unknown Cause/Condition
Condition: Unknown
Due 8 April 1982
Resolved 8 April 1982
Unknown
Issued 8 April 1982
Resolved
Unknown Component - Unknown Cause/Condition
Condition: Unknown
Due 8 April 1982
Resolved 8 April 1982
Unknown
Issued 8 April 1982
Resolved
Unknown Component - Unknown Cause/Condition
Condition: Unknown
Due 8 April 1982
Resolved 8 April 1982
Unknown
Issued 8 April 1982
Resolved
Unknown Component - Unknown Cause/Condition
Condition: Unknown
Due 8 April 1982
Resolved 8 April 1982
Lifesaving
Issued 16 February 1982
Resolved
PRIOR TO DEPARTURE FROM MARGAN CITY, LOUISIANA FOR COASTWISE SAILING, PRO- EPIRB AND DEMONSTRATED OPERATION TO LOGNIZANT OCMI.
Condition: Unknown
Due 16 February 1982
Resolved 16 February 1982
Engineering
Issued 16 February 1982
Resolved
VESSEL BOILER (USED FOR STEAM HAMMER OPERATIONS) IS NOT TO BE OPERATED UN- TIL SUCH TIME AS THE OPERATION OF THE BOILER LOW WATER CUT-OUT IS PROVEN.
Condition: Unknown
Due 16 February 1982
Resolved 16 February 1982
Electrical
Issued 16 February 1982
Resolved
MAKE PERMANENT REPAIRS TO #1 (FORWARD) SHIPPS SERVICE GENERATOR WITHIN 14 DAYS. REPAIRS ARE T0 BE COMPLETED TO SATISFACTION
Condition: Unknown
Due 16 February 1982
Resolved 16 February 1982
Lifesaving
Issued 16 February 1982
Resolved
VESSEL WILL BE LIMITED TO A TOTAL OF 175 PEOPLE ALLOWED ON BOARD UNTIL SUCHTIME AS ONE (1) ADD. UNFLATIBLE LIFERAFT IS PROVIDED AND INSTALLATION
Condition: Unknown
Due 16 February 1982
Resolved 16 February 1982