SEADOG II

SEADOG II is a 1997 passenger vessel (inspected). The Coast Guard has recorded 72 inspections since 1997, most recently in June 2026, along with 67 deficiencies and 4 casualty investigations between 2007 and 2022.

Records from 1997 to 2026. Most recent: inspection, 11 June 2026.

Built
1997
Last inspected
11 June 2026
Documentation
Case Pending · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDM9325
455441
Flag
UNITED STATES
367329530
Maury page id
psix-455441

Inspections, by type

…with no type recorded9
Years with a record 29 calendar years (1997–2026)
The 72 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)64.7 ft × 18.3 ft × 6.0 ft
Registered tonnagegross 47 / net 37
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderOCEAN ROCKETS INC · TUCKAHOE, NJ, UNITED STATES · built 1997
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portCHICAGO, IL
Trade endorsementsCoastwise, unrestricted
DocumentationCase Pending · issued 16 December 2025 · expires 31 January 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it47 - Simplified, Gross Ton
37 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDM9325MMSI 367329530 · active · compulsorily equipped · granted 21 April 2022, expires 21 April 2032
WDE2777MMSI 367329530 · cancelled · compulsorily equipped · granted 2 December 2017, cancelled 14 April 2022
WCX7083MMSI not assigned · expired · compulsorily equipped · granted 29 August 1997, cancelled 3 November 2007 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

SPIRIT OF CHICAGO Passenger (Inspected) · MISLE 300131 · 1 October 1997 · activity 160156

Inspection history · 72

11 June 2026 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8402838
5 May 2026 Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8367097
16 June 2025 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8160654
9 June 2025 Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8155479
6 May 2025 Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8129387
22 April 2025 In-Service Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8116751
17 March 2025 Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8094867
10 September 2024 In-Service Inspection · Examination of Repairs · Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8000181
5 August 2024 COI Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7969436
16 November 2023 Examination of Repairs · Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7825734
10 April 2023 Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7665692
30 July 2022 Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7520546
30 July 2022 Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7522562
27 June 2022 Damage Survey
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7488569
7 June 2022 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7470865
2 May 2022 Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7442554
3 March 2022 Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7405434
9 December 2021 Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7365496
26 August 2021 Damage Survey
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7296926
29 April 2021 Annual Inspection · Deficiency Check · DAPI Audit · Examination of Repairs
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7185925
10 March 2020 COI Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6923684
3 May 2019 Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6855859
1 November 2018 Drydock Exam · Plan Review "T" Boat · Examination of Repairs · Administrative Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6572825
26 July 2018 Examination of Repairs · Damage Survey
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6491255
19 April 2018 Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6395503
5 May 2017 Plan Review "T" Boat
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6139426
20 April 2017 Damage Survey
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6132400
12 April 2017 Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6122684
1 August 2016 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 5959186
28 April 2016 Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 5864985
22 October 2015 Deficiency Check · Damage Survey
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 5751796
11 October 2014 Damage Survey
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 5005520
11 October 2014 Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 5059702
7 August 2014 In-Service Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4952725
20 June 2014 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4894814
20 May 2012 In-Service Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4318591
28 February 2012 Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4252916
21 July 2011 Damage Survey
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4089729
29 March 2010 COI Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3704545
3 April 2009 Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3444265
27 August 2008 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3310467
7 July 2008 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3271677
11 July 2007 Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2991577
28 June 2007 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2976290
1 June 2007 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2948825
29 May 2007 Damage Survey
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2944830
27 May 2007 Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2977673
21 May 2007 Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2932351
13 April 2006 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2623711
7 April 2005 Deficiency Check
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 2328353
1 April 2005 COI Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 2315499
3 September 2004 Deficiency Check
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 2184249
20 August 2004 Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 2178616
24 May 2004 Deficiency Check · Annual Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 2067473
25 March 2004 Hull Examination
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 2026130
27 May 2003 Deficiency Check
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1803075
15 May 2003 Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1789100
6 May 2002 Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1607654
27 March 2002 Hull Examination
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1493914
11 April 2001 Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1435184
28 March 2001 Hull Examination
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1393635
9 September 2000 Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1459631
3 May 2000 COI Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1403122
10 May 1999 Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1447960
1 April 1999 Hull Examination
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1386474
14 June 1998 Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 79135
27 April 1998 Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1375398
24 April 1998 Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 43541
1 October 1997 Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 160156
9 July 1997 Deficiency Check
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1114978
22 June 1997 Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 28390
29 April 1997 Hull Examination · Plan Review "T" Boat · Initial Certification
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1105850

Deficiency record · 67

03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 5 May 2026 Resolved
Flexible non-metallic hose may be used in non-vital water systems subject to the requirements of 46 CFR 182.720(d)(1)(4). (i) Each penetration must be accomplished using a metallic through deck/bulkhead fitting that is welded or otherwise attached by an accepted method. (ii) One or more metallic valves must be installed adjacent to the fitting. One if operable from above the bulkhead deck. Two (one fitted on either side) if not. The water hoses in way of the toliet and sink, main deck, port penetrate the deck without the required fittings.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 June 2026
Resolved 11 June 2026
Resolution: Received photographic evidence of installation of valves at through deck/bulkhead penetrations.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 22 April 2025 Resolved
A seat must be constructed to prevent injury. Repair 6 seats on the starboard side with fractured welds and 4 seats on the port side and tighten all loose/backed out bolts.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 May 2025
Resolved 10 June 2025
Resolution: Weld pick up repairs have been made.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 27 June 2022 Resolved
Vessels master experienced vibration on the starboard propulsion while underway with passengers on June 25th. The Marine Casualty was not reported to the Coast Guard until June 26th via email vice notification to the Command Center at time of Occurrence. Investigate cause of vibration and effect repairs and conduct sea trials.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 July 2022
Resolved 30 June 2022
Resolution: Witnessed repair to shaft strut, engine mount bracket, and sheared mounting bolt.
09 - Working and Living Conditions › 092 - Working Conditions › Gangway, accommodation-ladder
Issued 2 May 2022 Resolved
2" x 2" x 42" embarkation ramp stanchions on port and starboard side need to be cropped and renewed. Weld repairs continue to break. Make repair in kind and notify OCMI for inspection.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 June 2022
Resolved 7 June 2022
Resolution: Both embarkation ramp stanchions have been cropped and renewed.
09 - Working and Living Conditions › 092 - Working Conditions › Gangway, accommodation-ladder
Issued 31 August 2021 Resolved
Vessel has cracked welds around corners of swim platform and embarkation platform stanchions. Submit repair plan for approval to make permanent repairs to the structural deficiencies to the satisfaction of local OCMI.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 September 2021
Resolved 2 May 2022
Resolution: Vessel has made repairs to swim platform and embarkation platform.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 26 August 2021 Resolved
Vessel has a sheared rudder/post assembly. Vessel shall make repairs and conduct sea trials/testing to the satisfaction of attending Marine Inspector prior to the carriage of passengers.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 23 September 2021
Resolved 31 August 2021
Resolution: Vessel port rudder system has been repaired and tested.
09 - Working and Living Conditions › 092 - Working Conditions › Gangway, accommodation-ladder
Issued 26 August 2021 Resolved
Vessel has cracked welds around corners of swim platform and embarkation platform stanchions. Submit repair plan approval for liste4d structural deficiencies to local OCMI prior to executing. Repairs shall be made to the satisfaction of local OCMI and prior to carriage of passengers.
Action required: 705 - Other - as specified
Due 24 September 2021
Resolved 31 August 2021
Resolution: Temporary repairs are in place to allow passengers until permanent fix/modification is applied.
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access Shore - Ship
Issued 13 May 2021 Resolved
Stanchions repaired but still have pickups. Temp bracket installed on stanchion. New CG-835 issued for repair, 14 days, no passenger restricitions.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 May 2021
Resolved 1 June 2021
Resolution: Pick up welds completed.
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access Shore - Ship
Issued 29 April 2021 Resolved
Embarkation/Debarkation ramp stanchions on vessel are failing. Starboard stanchion is broken and port stanchion has cracks in welds. Port and starboard swim platform aft most corners have cracks in their welds. Repair all above structural conditions to the satisfaction of Marine Inspectors prior to carriage of passengers and movement.
Condition: Damaged By Earlier Event
Action required: 60 - Rectify deficiencies prior to movement
Resolved 13 May 2021
Resolution: Stanchions repaired but still have pickups. Temp bracket installed on stanchion. New CG-835 issued for repair, 14 days, no passenger restricitions.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 29 April 2021 Resolved
Provide firefighting certificate reports for vessel installed CO2 system and portable fire extinguishers showing annual maintenance conducted.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 May 2021
Resolved 13 May 2021
Resolution: Docs provided for CO2 system and portable extinguishers were serviced for 2021 Annual.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 29 April 2021 Resolved
Provide battery operated portable lighting for the operation station and the propulsion space to the satisfaction of attending Marine Inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 May 2021
Resolved 13 May 2021
Resolution: Portable battery operated lights provided for operating station and propulsion space.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 29 April 2021 Resolved
The fire main junction directly after fire pump discharge side is leaking. Repair fire main leak to the satisfaction of attending Marine Inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 May 2021
Resolved 13 May 2021
Resolution: Firemain leak was repaired and system tested SAT.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 10 March 2020 Resolved
Complete required machinery testing of both port and starboard MDE alarms IAW CG-CVC Policy Letter 17-08 and CG-CVC Policy Letter 17-07
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 May 2021
Resolution: Received tech report for overhaul and alarm testing of port engine. Power trials were completed.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 10 March 2020 Resolved
Prior to carrying passengers, vessel much complete drills, testing of firepump, bilge pump, nav systems and verify all lifesaving equipment is on board.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 May 2021
Resolution: Satisfactory Annual/DAPI Inspections / Underway Drills completed. All systems compliance for passenger carriage was found SAT.
Construction/Loadline › Hull › Side Shell
Issued 20 April 2017 Resolved
Fiber glass damage on stern next to the center two vertical frames and on the bottom transverse frame center of two vertical frames.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 20 May 2017
Resolved 25 May 2017
Resolution: Completed Repair work
Engineering › Diesel Engine (propulsion-direct drive) › Block
Issued 28 April 2016 Resolved
Portside engine bed bolts not properly mounted with washers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 April 2016
Resolution: New washers of same size and type as starboard engine installed prior to operating vessel during inspection.
Engineering › Diesel Engine (propulsion-reduction gear) › Emergency shutdown
Issued 22 October 2015 Resolved
Starboard engine shutdown unexpectantly during operation with passengers. Prior to carrying passengers repair vessel to satisfaction of OCMI.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 October 2015
Resolution: Marine Inspector attended vessel, approved repairs and conducted underway test of vessel.
Engineering › Freshwater System (jacketwater cooling) › Pump
Issued 15 October 2014 Resolved
Port MDE shutdown while underway carrying passengers. Make permanent repairs to the satisfaction of attending Marine Inspector prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 October 2014
Resolution: Impeller replaced and tested sat.
Electrical › Electric Generation Source (service) › Switch
Issued 21 July 2011 Resolved
MSU Chicago received report from SLM CC of a loss of propulsion from Entertainment Cruises vsl M/V SEA DOG 2. The SEA DOG 2 was dockside at Navy Pier with 50 POB getting ready to get U/W, when the Captain tried to start the engine and the STBD engine would not start; starter failed. The company took proactive steps by unloading passengers & taking the vsl out of service. NO SAIL 835 was issued.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 July 2011
Resolution: attended vessel and witnessed proper operation of starter. tested several times. all sat
Fire Fighting › Fire Pumps › Pressure
Issued 29 March 2010 Resolved
Required O/O to install pressure gauge on the discharge side of the firepump IAW 46 CFR 181.300.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 April 2010
Resolved 19 July 2010
Navigation › Piloting/Steering › Compass Deviation Table
Issued 29 March 2010 Resolved
Provide updated deviation table for magnetic compass at operating station IAW 46 CFR 184.402
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 April 2010
Resolved 29 March 2010
Engineering › Freshwater System (intermediary cooling) › Piping
Issued 7 July 2008 Resolved
Provide double hose clamp on port mde exhaust r/w piping iaw 46 CFR 182.410(d)(4).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 August 2008
Resolved 14 July 2008
Resolution: Hose clamp installed.
Engineering › Diesel Engine (propulsion-reduction gear) › Crankshaft
Issued 7 July 2008 Resolved
Provide working rpm gauge for port mde iaw 46 CFR 182.410(b).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 August 2008
Resolved 14 July 2008
Resolution: New RPM gauge installed.
Engineering › Diesel Engine (propulsion-reduction gear) › Crankcase
Issued 7 July 2008 Resolved
Provide working oil pressure gauge for stbd mde iaw 46 CFR 182.410(b).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 August 2008
Resolved 14 July 2008
Resolution: New oil pressure gauge installed.
Fire Fighting › Emergency Fire Pumps › Arrangement
Issued 7 July 2008 Resolved
Ensure fire pump operates properly iaw 46 CFR 181.300.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 July 2008
Resolution: Fire pump fixed and operates properly.
Engineering › Bilge Water Management System › Pump
Issued 7 July 2008 Resolved
Demonstrate proper operation of bilge pump iaw 46 CFR 182.520.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 July 2008
Resolution: Bilge pump operates properly.
Operations/Management › Drills/Instruction › Not Conducted
Issued 7 July 2008 Resolved
Conduct drills iaw 46 CFR 185.520, .524
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 July 2008
Resolution: Drills conducted all sat.
Engineering › Reduction Gearing/Clutches › Gear
Issued 29 May 2007 Resolved
Provide proof that the port reduction gear is properly operating.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 June 2007
Resolution: Repairs completed, witnessed sea trials.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 21 May 2007 Resolved
Replenish First Aid IAW 46 CFR 184.710
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 June 2007
Resolved 22 June 2007
Resolution: First aid kit was replenished with new eye wash, ammonia swabs and asprin.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 21 May 2007 Resolved
Provide ringbuoy with new lifeline IAW 46 CFR 180.70
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 June 2007
Resolved 1 June 2007
Resolution: New ringbuoy installed.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 21 May 2007 Resolved
Replace 47 adult lifejackets IAW 46 CFR 180.71. Route restricted to 83 Adults until requirement is met.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 June 2007
Resolved 1 June 2007
Resolution: 47 adult lifejackets put in service.
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 13 April 2006 Resolved
Vessel is restricted to carry 127 persons until correct amount of life jackets are placed on board.
Action required: 705 - Other - as specified
Due 12 May 2006
Resolved 12 May 2006
Engineering › Lubricating Oil Service System › Gauge
Issued 13 April 2006 Resolved
prove proper operation of engine gauges for oil pressure and raw water.
Action required: 705 - Other - as specified
Due 12 May 2006
Resolved 12 May 2006
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 1 April 2005 Resolved
Provide proof of compliance with DAPI annual drug and alcohol program, in accordance with 46 CFR part 16.
Due 2 May 2005
Resolved 4 April 2005
Communications › Alarms/Indicators › Bilge Alarm
Issued 1 April 2005 Resolved
Provide operation of bilge high level alarm in accordance with 46 CFR 182.530 prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 April 2005
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 1 April 2005 Resolved
Mount stbd side deck rail, rail found loosely mounted to side rail.
Due 2 May 2005
Resolved 6 April 2005
Operations/Management › Equipment Service/Testing › EPIRB
Issued 1 April 2005 Resolved
Start monthly testing and logging of EPIRB in accordance with 46 CFR 185.728.
Due 2 May 2005
Resolved 6 April 2005
Navigation › Collision/Grounding Avoidance › Radar
Issued 1 April 2005 Resolved
Provide operation of radar in accordance with 46 CFR 184.404.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 April 2005
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 1 April 2005 Resolved
Replace waterlight on ring lifebuoy in accordance with 46 CFR 185.516.
Due 2 May 2005
Resolved 4 April 2005
Electrical › Electric Supply System (service) › Cable
Issued 1 April 2005 Resolved
Remove dead end wiring from both main diesel engines.
Due 2 May 2005
Resolved 6 April 2005
Fire Fighting › Fire Main › Condition
Issued 20 August 2004 Resolved
Discoved Fireman clogged during in-service inspection.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 August 2004
Resolved 20 August 2004
Resolution: Rep removed valve at fire plug, removed impeller piece and proved proper operation. Sighted this date [name withheld]
Communications › Alarms/Indicators › Bilge Alarm
Issued 20 August 2004 Resolved
Prove proper operation of Bilge high level alarm.
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 August 2004
Resolved 20 August 2004
Resolution: Rep discovered broken connector on back of alarm at helm. Sighted proper operation this date. [name withheld]
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 20 August 2004 Resolved
Repair broken port aft handrail.
Condition: Unknown
Due 27 August 2004
Resolved 3 September 2004
Resolution: Bolted down the rail
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 24 May 2004 Resolved
Provide proper contents of first aid kit.
Action required: 705 - Other - as specified
Due 24 June 2004
Resolved 27 May 2004
Fire Fighting › Combustible Materials › Furniture/Furnishings
Issued 24 May 2004 Resolved
Ensure all waste recepticles are noncombustable.
Action required: 705 - Other - as specified
Due 24 June 2004
Resolved 27 May 2004
Resolution: New UL approved garbage cans.
Engineering › Diesel Engine (propulsion-reduction gear) › Governor
Issued 24 May 2004 Resolved
Ensure proper shutdown of stbd eng normal and emergency scenarios prior to carrying passengers.
Action required: 705 - Other - as specified
Due 25 June 2004
Resolved 25 May 2004
Documentation › Logs/Records › Logbook (official)
Issued 24 May 2004 Resolved
Provide proper training log.
Action required: 705 - Other - as specified
Due 24 June 2004
Resolved 24 May 2004
Communications › Radio Communications
Issued 15 May 2003 Resolved
Replace out-of-date hydrostatic release unit for EPIRB
Due 23 May 2003
Resolved 30 May 2003
Documentation
Issued 9 September 2000 Resolved
PROVIDED PROOF OF CAPTAIN'S CURRENT FCC RADIO OPERATOR'S LICENSE TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 15 September 2000
Resolved 29 September 2000
Engineering
Issued 9 September 2000 Resolved
PROVIDE AND INSTALL FUEL OIL CUT OUT VALVES AT ENGINE SIDE OF FUEL LINES FOR BOTH MAIN DIESEL ENGINES, IN ACCORDANCE WITH 46 CFR 182.455(b)(4) TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR & COGNIZANT OCMI.
Condition: Unknown
Due 15 September 2000
Resolved 13 September 2000
Fire Fighting
Issued 9 September 2000 Resolved
PROVIDE PROOF OF PORTABLE FIRE EXTINGUISHER SERVICING TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 15 September 2000
Resolved 13 September 2000
Documentation
Issued 9 September 2000 Resolved
PROVIDE COPY OF CURRENT TRAINING LOGS FOR VESSEL'S CREW TO THE SATISFACTIONOF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 15 September 2000
Resolved 29 September 2000
Engineering
Issued 9 September 2000 Resolved
PROPERLY MOUNT/SUPPORT ENGINE ROOM FUEL OIL PIPING LOCATED IN BILGES RUN- ING FROM FUEL TANK TO BOTH MAIN DIESEL ENGINES AND TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 15 September 2000
Resolved 13 September 2000
Engineering
Issued 9 September 2000 Resolved
PROVIDE AND INSTALL FLAME SHIELDING FOR FUEL OIL EMERGENCY SHUT OFF VALVES,LOCATED AT FUEL OIL TANK, IN ACCORDANCE WITH 46 CFR 182.455(b)(4) OR PRO- VIDE AN ACCEPTABLE ALTERNATIVE FOR THE SAME TO THE SATISFACTION OF THE AT- TENDING MARINE INSPECTOR AND THE COGNIZANT OCMI.
Condition: Unknown
Due 15 September 2000
Resolved 13 September 2000
Construction/Loadline
Issued 1 April 1999 Resolved
Prior to carrying passengers, make all watertight bulkheads watertight to the satisfaction of an attending CG marine inspector.
Condition: Unknown
Due 29 April 1999
Resolved 29 April 1999
Construction/Loadline
Issued 1 April 1999 Resolved
Prior to carrying passengers, make permanent repairs to all holes and penetrations to the satisfaction of an attending CG marine inspector.
Condition: Unknown
Due 29 April 1999
Resolved 29 April 1999
Construction/Loadline
Issued 1 April 1999 Resolved
Prior to carrying passengers, make permanent repairs to all wire penetrations in all watertight bulkheads to the satifaction of an attendingCG marine inspector.
Condition: Unknown
Due 29 April 1999
Resolved 29 April 1999
Construction/Loadline
Issued 27 April 1998 Resolved
PRIOR TO CARRIAGE OF PASSENGERS, MAKE REPAIRS TO TRANSVERSE FRAMING 30FT. AFT OF STEM AT CHINE LINE TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 14 June 1998
Resolved 26 May 1998
Lifesaving
Issued 29 April 1997 Resolved
MAKE VESSEL AVAILABLE FOR UNDERWAY DRILLS (FIRE & MAN OVERBOARD) IN THE PRESENCE OF A USCG MARINE INSPECTOR.
Condition: Unknown
Due 29 April 1997
Resolved 29 April 1997
Documentation
Issued 29 April 1997 Resolved
PROVIDE A LICENSED CAPTAIN.
Condition: Unknown
Due 29 April 1997
Resolved 29 April 1997
Engineering
Issued 29 April 1997 Resolved
PROVE PROPER OPERATION OF FUEL SYSTEM. THE SYSTEM NEEDS TO BE OPERATIONALLY TESTED WITH A FULL TANK OF FUEL.
Condition: Unknown
Due 29 April 1997
Resolved 29 April 1997
Navigation
Issued 29 April 1997 Resolved
PROVE PROPER OPERATION OF ALL REQUIRED ELECTRONIC EQUIPMENT.
Condition: Unknown
Due 29 April 1997
Resolved 29 April 1997
Documentation
Issued 29 April 1997 Resolved
PROVIDE PROOF OF ENROLLMENT IN APPROVED CHEMICAL TESTING PROGRAM.
Condition: Unknown
Due 29 April 1997
Resolved 29 April 1997
Lifesaving
Issued 29 April 1997 Resolved
PROVIDE POSTED COPY OF EMERGENCY CHECKOFF LIST
Condition: Unknown
Due 29 April 1997
Resolved 29 April 1997
Construction/Loadline
Issued 29 April 1997 Resolved
PROVIDE PROPER MARKING ON VESSEL HULL.
Condition: Unknown
Due 29 April 1997
Resolved 29 April 1997
Documentation
Issued 29 April 1997 Resolved
PROVIDE ALL FCC DOCUMENTS.
Condition: Unknown
Due 29 April 1997
Resolved 29 April 1997
Navigation
Issued 29 April 1997 Resolved
PROVIDE CHARTS OF ENTIRE OPERATING AREA AND ALL REQUIRED PUBLICATIONS.
Condition: Unknown
Due 29 April 1997
Resolved 29 April 1997

Casualty record · 4

27 May 2007Routine · role: Involved in a Marine Casualty · activity 2977673
28 June 2013Routine · role: Involved in a Marine Casualty · activity 4797617
11 October 2014Routine · role: Involved in a Marine Casualty · activity 5059702
30 July 2022Routine · role: Involved in a Marine Casualty · activity 7522562
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

SEA DOG II (2007). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.