Records from 1982 to 2018. Most recent: inspection, 14 November 2018.
Inspection history · 68
14 November 2018
Administrative Inspection · Damage Survey
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6580544
12 March 2018
Annual Inspection · Administrative Inspection · Hull Examination · DAPI Audit
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6368995
29 June 2017
Type not recorded
No type recorded · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6191662
20 March 2017
COI Inspection · Administrative Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6104819
1 February 2017
Hull Examination · Internal Structural Exam · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6078696
16 May 2016
Annual Inspection · DAPI Audit · Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 5876522
3 March 2014
Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 4809348
13 July 2011
Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 4062847
16 March 2010
Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 3694536
18 March 2009
Drydock Exam · Deficiency Check · Internal Structural Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 3432611
4 March 2009
Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 3428707
26 June 2008
Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 3337073
5 May 2008
Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 3196357
19 March 2007
COI Inspection · Hull Examination
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2890450
1 August 2006
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2733034
20 July 2006
In-Service Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2724333
20 July 2006
Type not recorded
No type recorded · USCGC COHO (WPB 87321) · USCG Southeast District (CGD-SE) · Activity 2724366
21 February 2006
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2708087
1 March 2005
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2301200
13 January 2005
Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2274139
28 December 2004
Administrative Inspection
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2265600
25 March 2004
Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2035407
18 March 2004
Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2034213
4 April 2003
Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 1770207
5 March 2003
Hull Examination
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 1752872
19 March 2002
COI Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 1495301
22 April 2001
Type not recorded
No type recorded · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 158054
11 April 2001
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1387129
11 April 2001
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1473446
16 January 2001
Hull Examination
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 1399531
27 August 2000
Type not recorded
No type recorded · USCGC COBIA (WPB 87311) · USCG Heartland District (CGD-H) · Activity 1516040
23 March 2000
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 818697
10 March 1999
COI Inspection · Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1378661
2 December 1998
Plan Review "T" Boat
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1341102
16 September 1998
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1452434
23 May 1998
Type not recorded
No type recorded · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 130616
2 April 1997
Re-Inspection · Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1414783
24 March 1996
Type not recorded
No type recorded · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 90137
6 March 1996
COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1377696
7 September 1995
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1446240
6 March 1995
COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1425560
19 April 1994
Type not recorded
No type recorded · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 60810
15 April 1994
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 857955
16 March 1994
COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 855482
24 February 1994
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1165731
23 June 1993
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1155036
14 May 1993
COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 828022
5 February 1993
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1139558
31 August 1992
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 962653
15 June 1992
COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 947258
27 June 1991
COI Inspection · Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 940696
22 February 1990
COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 904802
24 April 1989
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1341015
17 February 1989
COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1033195
25 March 1988
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 994164
25 February 1988
COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1030150
21 October 1987
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1017069
20 October 1987
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1327086
15 October 1987
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1327198
6 March 1987
Deficiency Check · COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1325453
30 April 1986
Credit Drydock
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 986143
4 March 1986
COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 992617
5 March 1985
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 981102
15 November 1984
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 977066
13 March 1984
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1280199
11 March 1983
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1275552
8 March 1983
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1279234
2 March 1982
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1275472
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 16 May 2016
Resolved
Provide fixed fire system service report.
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 May 2016
Resolved 16 May 2016
Resolution: Vessel provided report.
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 16 May 2016
Resolved
Provide valid alcohol test equipment.
Action required: 705 - Other - as specified
Due 30 May 2016
Resolved 6 June 2016
Resolution: Vessel provided test equipment
Lifesaving › Lifefloat › Painter
Issued 16 May 2016
Resolved
Properly mount lifefloat painter canisters
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 May 2016
Resolved 6 June 2016
Resolution: Vessel properly mounted canister
Lifesaving › Lifefloat › Float-free Link
Issued 16 May 2016
Resolved
Replace lifefloat weaklink with proper size.
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 May 2016
Resolved 6 June 2016
Resolution: Vessel replaced weaklink
Fire Fighting › Fire Pumps › Pressure
Issued 16 May 2016
Resolved
Replace firepump pressure gage.
Action required: 705 - Other - as specified
Due 30 May 2016
Resolved 6 June 2016
Resolution: Vessel replaced gage.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 3 March 2014
Resolved
Increase the size of the access door to the fixed firefighting canisters to allow for manual activation of eth system and mark with operating instructions.
Action required: 705 - Other - as specified
Due 10 March 2014
Resolved 17 March 2014
Engineering › Diesel Engine (propulsion-electric) › Crankcase
Issued 3 March 2014
Resolved
Troubleshoot/repair exhaust leaks from the valve cover and oil pressure relief valve on the vessels generator.
Action required: 705 - Other - as specified
Due 10 March 2014
Resolved 17 March 2014
Personnel › Training › First Aid/CPR
Issued 3 March 2014
Resolved
Ensure at least 50% of teh crew has current CPR training.
Action required: 705 - Other - as specified
Due 3 April 2014
Resolved 17 March 2014
Communications › Alarms/Indicators › Bilge Alarm
Issued 13 July 2011
Resolved
The bilge alarm light indicator for the forepeak is out. Ensure light for the alarm is working.
Action required: 705 - Other - as specified
Due 27 July 2011
Resolved 12 September 2011
Resolution: Witnessed opertional test with sat results.
Electrical › Lighting (service) › Lighting Fixture
Issued 13 July 2011
Resolved
Ensure light in fwd berthing area IWO frame 18 has a cover.
Action required: 705 - Other - as specified
Due 27 July 2011
Resolved 12 September 2011
Resolution: New cover installed,
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Instructions
Issued 13 July 2011
Resolved
Placard/Label req'd for the CO2 pull at the operating station.
Action required: 705 - Other - as specified
Due 27 July 2011
Resolved 12 September 2011
Resolution: Instructions placard installed.
Electrical › Lighting (service) › Outlet Box
Issued 13 July 2011
Resolved
Electrical outlet box located on cabin top is not waterproof.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 14 July 2011
Resolved 12 September 2011
Resolution: New outlet box installed.
Lifesaving › Lifefloat › Float-free Link
Issued 13 July 2011
Resolved
Weak links had no approval tags.
Action required: 705 - Other - as specified
Due 27 July 2011
Resolved 12 September 2011
Resolution: New weak link with approval tags installed.
Stability › Watertight Integrity › Weathertight Enclosure
Issued 16 March 2010
Resolved
Vessel had 05 cracked windows on the bridge of the vessel that need to be replaced.
Condition: Improper/Lack of Maintenance
Due 16 April 2010
Resolved 30 March 2010
Navigation › Piloting/Steering › US Coast Pilot
Issued 16 March 2010
Resolved
Vessel has out of date Coast Pilot and Light List onboard at the time of the inspection.
Condition: Improper/Lack of Maintenance
Due 16 April 2010
Resolved 30 March 2010
Engineering › Fuel Oil Service System › Piping
Issued 16 March 2010
Resolved
Fuel supply lines and return lines on the main engines were wasted
Condition: Improper/Lack of Maintenance
Due 16 April 2010
Resolved 30 March 2010
Engineering › Fuel Oil Storage/Transfer System › Tank
Issued 16 March 2010
Resolved
Fuel return lines on Diesel Fuel tanks were leaking and need to be repaired.
Condition: Improper/Lack of Maintenance
Due 16 April 2010
Resolved 30 March 2010
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type 1
Issued 16 March 2010
Resolved
Sewage line leaking on stbd side of vessel.
Condition: Improper/Lack of Maintenance
Due 16 April 2010
Resolved 30 March 2010
Accommodation/Occupational Safety › Potable Water System › General
Issued 16 March 2010
Resolved
Potable water line was wasted and leaking in the Portside Engineroom.
Condition: Improper/Lack of Maintenance
Due 16 April 2010
Resolved 30 March 2010
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 16 March 2010
Resolved
Navigation light cables/ wiring was wasted and corroded.
Condition: Improper/Lack of Maintenance
Due 16 April 2010
Resolved 30 March 2010
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 16 March 2010
Resolved
Vessels type 1 lifejackets were becoming unservicable and in need of replacement.
Condition: Improper/Lack of Maintenance
Due 16 April 2010
Resolved 30 March 2010
Operations/Management › Drills/Instruction › Not Conducted
Issued 16 March 2010
Resolved
Emergency drills were not being logged as being conducted onboard the vessel.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 March 2010
Electrical › Electrical Distribution System (service) › Junction Box
Issued 16 March 2010
Resolved
Grease found on wiring leading in to junction box, junction box was not properly sealed.
Condition: Improper/Lack of Maintenance
Due 16 April 2010
Resolved 30 March 2010
Construction/Loadline › Hull › Transverse Frame
Issued 18 March 2009
Resolved
Replace (3) cracked frames located on the port side of bunk room (Frames 14,15 &16).
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 April 2009
Construction/Loadline › Hull › Transverse Frame
Issued 18 March 2009
Resolved
Replace one rotted frame located in the aft bunk room (Frame 23/port-side).
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 April 2009
Engineering › Bilge Water Management System › Pump
Issued 18 March 2009
Resolved
Secure bilge pump in lazarette to the hull and use pressure connections for associated wiring.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 April 2009
Accommodation/Occupational Safety › Washroom/Toilet › Hot and Cold Running Water
Issued 4 March 2009
Resolved
Properly secure hot water heater in engine room.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 March 2009
Resolution: Water heater removed.
Engineering › Compressed Air System (start air) › Receiver/Bottle
Issued 4 March 2009
Resolved
Remove wasted air start pressure vessel for generator. Noted to be extremely pitted and corroded.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 March 2009
Electrical › Electrical Distribution System (service) › Cable
Issued 4 March 2009
Resolved
Remove large dead end cable under wheel house.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 March 2009
Communications › Radio Communications › EPIRB
Issued 4 March 2009
Resolved
Replace expired EPIRB hydrostatic release.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 March 2009
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 4 March 2009
Resolved
Replace 02 adult and 04 child PFD's removed from service and destroyed this date.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 March 2009
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Condition
Issued 5 May 2008
Resolved
Replace 3 B-II fire extinguishers, and mounts.
Due 7 May 2008
Resolved 8 May 2008
Electrical › Electrical Distribution System (service) › Junction Box
Issued 5 May 2008
Resolved
Seal outlet box for referigerator.
Due 5 June 2008
Resolved 8 May 2008
Accommodation/Occupational Safety › Heating › Catch Pan
Issued 5 May 2008
Resolved
Clean grease from griddle, and surrounding area, and exhaust vent.
Action required: 705 - Other - as specified
Resolved 8 May 2008
Electrical › Electrical Distribution System (service) › Wiring
Issued 5 May 2008
Resolved
Provide proper wire connections for aft bilge pump in lazerette.
Due 5 June 2008
Resolved 8 May 2008
Fire Fighting › Fixed Gas Fire Extinguishing System › Piping
Issued 5 May 2008
Resolved
Install galley hood fire extinguishing system. IAW 46CFR181.400(d) & 181.425
Due 5 June 2008
Resolved 26 June 2008
Construction/Loadline › Hull › Side Shell
Issued 19 March 2007
Resolved
Repair hull planking starboard side below water line to as built specifications.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 April 2007
Resolved 13 April 2007
Construction/Loadline › Structures › Transverse Bulkhead
Issued 19 March 2007
Resolved
Repair forward machinery space bulkhead port side in way of bilge strake to as built specifications.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 April 2007
Resolved 13 April 2007
Construction/Loadline › Hull › Transverse Frame
Issued 19 March 2007
Resolved
Repair/replace gussets on frame 1 through 9, machinery space, port side beginning at forward bulkhead to as built specifications.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 April 2007
Resolved 13 April 2007
Construction/Loadline › Hull › Stringer
Issued 19 March 2007
Resolved
Repair wasted and decayed floors under center propulsion engine to as built specifications.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 April 2007
Resolved 13 April 2007
Construction/Loadline › Hull › Side Shell
Issued 19 March 2007
Resolved
Repair areas of localized sheathing de-lamination on hull planking as marked by marine inspector to as built specifications.
Condition: Unknown
Action required: 705 - Other - as specified
Due 19 April 2007
Resolved 13 April 2007
Construction/Loadline › Hull › Keel
Issued 19 March 2007
Resolved
Repair sheathing in way of garboard strake port side as marked by marine inspector to as built specifications.
Condition: Unknown
Action required: 705 - Other - as specified
Due 19 April 2007
Resolved 13 April 2007
Personnel › Manning/Qualifications › Minimum Safe Manning
Issued 20 July 2006
Resolved
Veseel did not have sufficient crew as required by their COI.
Action required: 17 - Rectify deficiencies prior to departure
Due 20 July 2006
Resolved 20 July 2006
Operations/Management › Drills/Instruction › Not Conducted
Issued 20 July 2006
Resolved
Vessel failed to document crew training as required by 46 CFR 185.
Action required: 17 - Rectify deficiencies prior to departure
Due 20 July 2006
Resolved 25 April 2007
Operations/Management › Drills/Instruction › Not Conducted
Issued 20 July 2006
Resolved
Vessel failed to conduct crew training.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 April 2007
Documentation › Manifests/Lists › Emergency Checkoff List
Issued 21 February 2006
Resolved
Post station bill as required by 46 CFR 185.514
Action required: 705 - Other - as specified
Due 21 March 2006
Resolved 20 March 2006
Navigation › Piloting/Steering › Coast Guard Light List
Issued 21 February 2006
Resolved
Provide current copies or excerpts from navigation safety publications required by 46 CFR 184.420
Action required: 705 - Other - as specified
Due 21 March 2006
Resolved 20 March 2006
Communications › Radio Communications › EPIRB
Issued 21 February 2006
Resolved
[name withheld] with battery replacement date. 185.728
Action required: 705 - Other - as specified
Due 21 March 2006
Resolved 20 March 2006
Lifesaving › Lifefloat › Painter
Issued 21 February 2006
Resolved
Replace worn/frayed painters on all lifefloats. 46 CFR 180.137
Action required: 705 - Other - as specified
Due 21 March 2006
Resolved 20 March 2006
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 21 February 2006
Resolved
Service or replace lifefloat electric floating light. 46 CFR 180.137
Action required: 705 - Other - as specified
Due 21 March 2006
Resolved 20 March 2006
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 21 February 2006
Resolved
Provide copy of annual service report for fixed CO2 fire fighting system certifying cylinder full weight. (46 CFR 176.810)
Action required: 705 - Other - as specified
Due 21 March 2006
Resolved 24 February 2006
Engineering › Fuel Oil Service System › Filter
Issued 21 February 2006
Resolved
Replace wasted port fuel filter (racor) bracket. (46 CFR 176.800)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 March 2006
Resolved 20 March 2006
Engineering › Fuel Oil Storage/Transfer System › Tank
Issued 21 February 2006
Resolved
Repair wasted fuel tank bonding straps. (46 CFR 182.440)
Action required: 705 - Other - as specified
Due 21 March 2006
Resolved 20 March 2006
Engineering › Fuel Oil Storage/Transfer System › Hose
Issued 21 February 2006
Resolved
Replace port fuel tank fill hose and clamps. (46 CFR 176.800)
Action required: 705 - Other - as specified
Due 21 March 2006
Resolved 20 March 2006
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 21 February 2006
Resolved
Install suitable guards on generator belt drives, center and port engine flywheels. (46 CFR 176.960)
Action required: 705 - Other - as specified
Due 21 March 2006
Resolved 20 March 2006
Electrical › Electrical Distribution System (service) › Conductor
Issued 21 February 2006
Resolved
Found excessive splices in 12 volt bilge pump conductor. Replace with properly sized conductor and secure butt splices to a suitable junction box. (46 CFR 183.430)
Action required: 705 - Other - as specified
Due 21 March 2006
Resolved 20 March 2006
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 21 February 2006
Resolved
Secure open MSD drain lines with suitable caps. (46 CFR 176.800)
Action required: 705 - Other - as specified
Due 21 March 2006
Resolved 20 March 2006
Communications › Alarms/Indicators › Bilge Alarm
Issued 1 March 2005
Resolved
Provide visual indication on Bilge Alarm Panel to indicate the visual alarm for fwd bunk room and lazarette.
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 March 2005
Resolved 7 March 2005
Electrical › Lighting (emergency) › Lighting Fixture
Issued 1 March 2005
Resolved
Make proper repairs to emergency lighting for main deck and aft.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 March 2005
Resolved 7 March 2005
Communications › Radio Communications › Radiotelephone Transceiver (2-4 MHz)
Issued 1 March 2005
Resolved
Prove proper operation of SSB Radio.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 March 2005
Resolved 7 March 2005
Navigation › Piloting/Steering › Marine Charts
Issued 1 March 2005
Resolved
Provide corrected/updated navigation chart for the area navigated.
Action required: 705 - Other - as specified
Due 15 March 2005
Resolved 7 March 2005
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 1 March 2005
Resolved
Prove proper operation of water light on life float & life ring lights.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 March 2005
Resolved 7 March 2005
Lifesaving › Lifejacket/PFD (Type III) › Condition
Issued 1 March 2005
Resolved
Provide 17 adult and 2 child lifejackets. Replace and perform maintenance (i.e. buckles and retro) on remaining life jackets.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 March 2005
Resolved 7 March 2005
Construction/Loadline › Hull › Transverse Frame
Issued 13 January 2005
Resolved
Repair as original port transverse frames 5-9.
Action required: 705 - Other - as specified
Due 1 March 2005
Resolved 1 March 2005
Construction/Loadline › Hull › Transverse Frame
Issued 13 January 2005
Resolved
Repair as original port 5 & aft frames located in 2nd Bunk Room.
Action required: 705 - Other - as specified
Resolved 1 March 2005
Construction/Loadline › Hull › Transverse Frame
Issued 13 January 2005
Resolved
Repair as original stbd aft frame in 2nd bunk room.
Action required: 705 - Other - as specified
Resolved 1 March 2005
Construction/Loadline › Hull › Transverse Frame
Issued 13 January 2005
Resolved
Make proper repairs to cracked frame below center main engine.
Action required: 705 - Other - as specified
Due 13 January 2006
Resolved 13 April 2007
Construction/Loadline › Hull › Transverse Frame
Issued 13 January 2005
Resolved
Properly address rotted frames in engine room.
Action required: 705 - Other - as specified
Due 13 January 2006
Resolved 13 April 2007
Construction/Loadline › Hull › Transverse Frame
Issued 10 January 2005
Resolved
Repair as original Stbd frames 5-7 in first berthing area.
Action required: 705 - Other - as specified
Resolved 1 March 2005
Lifesaving › Rigid Liferafts
Issued 18 March 2004
Resolved
Renew retroreflective tape on 5 life floats. LEGACY COMPONENT DESC: Retro tape
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 March 2004
Resolution: Owner renewed retroreflective tape on 5 life floats.
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 18 March 2004
Resolved
Repair fuel leak in E/R aft bulkhead. LEGACY COMPONENT DESC: Fuel Leak
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 April 2004
Resolved 25 March 2004
Resolution: Owner repaired fuel leak in E/R aft bulkhead.
Lifesaving › Rigid Liferafts
Issued 18 March 2004
Resolved
Replace nylon line on all life float water lights LEGACY COMPONENT DESC: Lamp (outside)
Action required: 705 - Other - as specified
Due 18 April 2004
Resolved 25 March 2004
Resolution: Owner replaced nylon line on all life float waterlights.
Lifesaving › Lifejacket/PFD (Type I)
Issued 18 March 2004
Resolved
Renew retro tape on child lifejackets LEGACY COMPONENT DESC: Retroreflective Material
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 April 2004
Resolved 25 March 2004
Resolution: Owner renewed retrotape on child lifejackets.
Construction/Loadline › Hull
Issued 5 March 2003
Resolved
Renew 4 throughbolts identified by CG inspector. LEGACY COMPONENT DESC: Longitudinal Frame
Action required: 705 - Other - as specified
Due 5 April 2003
Resolved 5 March 2003
Resolution: Owner renewed 4 throughbolts.
Engineering
Issued 14 May 1993
Resolved
PROPERLY MARK FUEL OIL SHUTOFF VALVE TO PORT FUEL OIL TANK.
Condition: Unknown
Due 14 May 1993
Resolved 14 May 1993
Electrical
Issued 14 May 1993
Resolved
RENEW DETERIORATED 110VAC ARMORED ELECTRICAL CABLE TO STERN DECK LIGHTING.
Condition: Unknown
Due 14 May 1993
Resolved 14 May 1993
Accommodation/Occupational Safety
Issued 14 May 1993
Resolved
REPAIR DRAIN LINE AT FLEXIBLE COUPLING ABOVE CENTER MAIN DIESEL ENGINE.
Condition: Unknown
Due 14 May 1993
Resolved 14 May 1993
Accommodation/Occupational Safety
Issued 14 May 1993
Resolved
PROVE OPERATION LADIES BATHROOM VENT FAN MOTOR.
Condition: Unknown
Due 14 May 1993
Resolved 14 May 1993
Accommodation/Occupational Safety
Issued 14 May 1993
Resolved
PROVE OPERATION OF HOT WATER HEATER PRESSURE RELIEF VALVE.
Condition: Unknown
Due 14 May 1993
Resolved 14 May 1993
Lifesaving
Issued 14 May 1993
Resolved
PROVIDE -2- CHILD LIFE PRESERVERS.
Condition: Unknown
Due 14 May 1993
Resolved 14 May 1993
Engineering
Issued 15 June 1992
Resolved
REPAIR LEAK TO PORT FUEL OIL TANK WHERE FUEL OIL RETURN LINE ATTACHES TO FUEL OIL TANK.
Condition: Unknown
Due 15 June 1992
Resolved 15 June 1992
Electrical
Issued 25 February 1988
Resolved
PROVE PROPER OPERATION OF ELECTIC REEL RECEPTICLE INSTALLATION PRIOR TO USEBY PASSENGERS.
Condition: Unknown
Due 25 February 1988
Resolved 25 February 1988