Records from 1982 to 1996. Most recent: inspection, 9 August 1996.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 36
9 August 1996
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1087063
12 June 1996
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 877840
13 March 1996
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1425699
22 February 1996
Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1377612
3 March 1995
Examination of Repairs
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1419397
9 January 1995
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 862616
21 December 1994
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1405647
29 September 1994
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 147565
24 February 1994
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1354588
10 May 1993
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 666502
6 May 1993
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 53009
3 May 1993
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1148371
23 March 1993
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1146468
22 March 1993
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1146790
3 February 1993
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1133032
21 December 1992
COI Inspection · Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 828253
20 March 1992
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 954961
26 April 1991
Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1003164
20 March 1991
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 903777
3 August 1990
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 913009
3 May 1990
Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 914588
12 May 1989
COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1205420
15 August 1988
Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1342999
31 May 1988
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1194773
23 April 1988
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1035253
14 April 1988
Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1032628
9 March 1988
Hull Examination
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1029092
3 August 1987
Administrative
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1031638
10 July 1987
Administrative
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1322136
17 April 1987
COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1026213
30 April 1986
Re-Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 986233
2 May 1985
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 983140
29 May 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 973158
9 May 1983
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 965658
25 April 1983
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1273897
30 November 1982
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 971414
Electrical
Issued 13 March 1996
Resolved
PROVE PROPER OPERATION OF LOW L/O SHUT DOWN & ALARM & HIGH JACKET WATER ALARM ON THE EMERGENCY GENERATOR.
Condition: Unknown
Due 20 March 1996
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Electrical
Issued 13 March 1996
Resolved
REPLACE ALL DAMAGED ELECTRICAL WIRING ON MAIN DECK WITH APPROVED ARMORED WIRE.
Condition: Unknown
Due 13 April 1996
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Lifesaving
Issued 13 March 1996
Resolved
INSTALL GENERAL ALARM BELLS OUTSIDE OF MAIN DECK PAINT LOCKER & IN VICINITYOF HELO PAD STRUCTURE TO ENSURE GENERAL ALARM IS AUDIBLE IN THOSE LOCATIONS.
Condition: Unknown
Due 13 April 1996
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Electrical
Issued 13 March 1996
Resolved
PROPERLY SECURE ALL WIRING WITH 5/8 INCH NON CORROSIVE STEEL BANDING MATERIAL ELIMINATING THE EXISTING PLASTIC WIRE TIES, THROUGHOUT THE VESSEL.
Condition: Unknown
Due 13 April 1996
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Electrical
Issued 13 March 1996
Resolved
PROVE PROPER OPERATION OF THE REVERSE POWER TRIP ON THE #4 GENERATOR.
Condition: Unknown
Due 20 March 1996
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Electrical
Issued 13 March 1996
Resolved
PROVE PROPER OPERATION OF THE JACKET WATER TEMP ALARMS ON ALL FOUR GENERATORS WITH ACTUAL TEMPERATURES.
Condition: Unknown
Due 20 March 1996
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Electrical
Issued 13 March 1996
Resolved
REPAIR OIL LEAK ON #1 GEN OIL PAN.
Condition: Unknown
Due 20 March 1996
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Electrical
Issued 13 March 1996
Resolved
RECONNECT TELLTALE LINE (FUEL PUMP) ON #2 GENERATOR.
Condition: Unknown
Due 20 March 1996
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Electrical
Issued 13 March 1996
Resolved
REALIGN COOLING WATER LINE (INLET) TO #4 GENERATOR.
Condition: Unknown
Due 20 March 1996
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Construction/Loadline
Issued 21 December 1994
Resolved
PROVE OPERATION OF OILY WATER SEPERATOR.
Condition: Unknown
Due 21 January 1995
Resolved 13 January 1995
Lifesaving
Issued 21 December 1994
Resolved
INSTALL FLASHING RED LIGHT FOR GENERAL ALARM SYSTEM IN GENERATOR ROOM.
Condition: Unknown
Due 21 January 1995
Resolved 13 January 1995
Accommodation/Occupational Safety
Issued 21 December 1994
Resolved
DEGREASE AND CLEAN ALL SUPPLY AND EXHAUST FAN GUARDS IN MACHINERY SPECES.
Condition: Unknown
Due 21 January 1995
Resolved 13 January 1995
Engineering
Issued 21 December 1994
Resolved
PROVIDE APPROVED TEST PROCEDURES FOR AUXILLIARY BOILER HOT WATER HEATER.
Condition: Unknown
Due 21 March 1995
Resolved 13 January 1995
Construction/Loadline
Issued 21 December 1994
Resolved
REMOVE LOCKING TAB DEVICES FROM ALL WATERTIGHT DOORS THROUGH OUT THE VESSEL.
Condition: Unknown
Due 21 January 1995
Resolved 13 January 1995
Engineering
Issued 21 December 1992
Resolved
PROVIDE SERVICING REPORTS FOR OWS 15 PPM SHUTDOWN. SEND COPY TO NEWMS ALONGWITH COPY OF APPR0VAL LETTER.
Condition: Unknown
Due 21 December 1992
Resolved 21 December 1992
Engineering
Issued 21 December 1992
Resolved
TEST OVERSPEED TRIPS ON ALL THREE JET PUMPS AND RECORD IN THE MASTERS LOG. SEND TESTING DATA TO NEWMS.
Condition: Unknown
Due 21 December 1992
Resolved 21 December 1992
Documentation
Issued 20 March 1991
Resolved
OBTAIN CERTIFICATE OF FINANCIAL RESPONSIBILITY FOR VESSEL AND SHOW SAME TO COGNIZANT OCMI._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 20 March 1991
Resolved 20 March 1991
Fire Fighting
Issued 3 May 1990
Resolved
BRING VESSEL,S GENERATOR ROOM AND AUXILLARY MACHINERY SPACE INTO COMPLIANCEWITH 46 CFR PART 95-15. GENERATOR SPACE FAS INSUFFICIENT CO2. AUX MACHINERY SPACE HAS NONE.
Condition: Unknown
Due 3 May 1990
Resolved 3 May 1990
Electrical
Issued 12 May 1989
Resolved
DEMONSTRATE OPERATION OF AND CAPABILITY TO TRANSMIT AND RECEIVE ON 2182 MHZ, HF MARINE RADIO.
Condition: Unknown
Due 12 May 1989
Resolved 12 May 1989
Unknown
Issued 14 April 1988
Resolved
REPAIR #2 BILGE PUMP AND DEMONSTRATE OPERATION TO A COAST GUARD MARINE INSPECTOR PRIOR TO THE VESSEL GETTING UNDERWAY.
Condition: Unknown
Due 14 April 1988
Resolved 14 April 1988
Deck/Cargo
Issued 14 April 1988
Resolved
DEMONSTRATE OPERATION OF THE FOUR ANCHOR WINCH PRIME MOVERS' PNEUMATIC CONTROLS AND SHUTDOWNS TO A COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 14 April 1988
Resolved 14 April 1988
Engineering
Issued 14 April 1988
Resolved
CONDUCT AN OPERATIONAL TEST OF THE OILY WATER SEPARATOR WITH AN OIL SOLUTION IN THE PRESENCE OF A COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 14 April 1988
Resolved 14 April 1988
Fire Fighting
Issued 14 April 1988
Resolved
UPDATE ALL FIRE CONTROL PLANS ON VESSEL TO SHOW THE PROPER LOCATION AND SIZE OF PORTABLE EXTINGUISHERS.
Condition: Unknown
Due 14 April 1988
Resolved 14 April 1988
Documentation
Issued 14 April 1988
Resolved
PROVIDE A COPY OF A VALID LOADLINE CERTIFICATE TO MARINE SAFETY OFFICE, PORT ARTHUR, TEXAS, PRIOR TO GETTING THE VESSEL UNDERWAY.
Condition: Unknown
Due 14 April 1988
Resolved 14 April 1988
Engineering
Issued 14 April 1988
Resolved
RE-LABEL ALL REMOTE FUEL OIL SHUT-OFF VALVE HAND WHEELS.
Condition: Unknown
Due 14 April 1988
Resolved 14 April 1988
Fire Fighting
Issued 14 April 1988
Resolved
REPAIR FIREMAIN IN ACCORDANCE WITH 46CFR56.70-15 (CLASS II PIPING) PRIOR TO GETTING THE VESSEL UNDERWAY.
Condition: Unknown
Due 14 April 1988
Resolved 14 April 1988
Documentation
Issued 14 April 1988
Resolved
PROVIDE AND POST BY THE FUEL OIL TRANSFER PUMPS A FUEL OIL TRANSFER PROCEDURE AND SCHEMATIC DRAWING OF THE FUEL OIL TRANSFER SYSTEM.
Condition: Unknown
Due 14 April 1988
Resolved 14 April 1988
Fire Fighting
Issued 14 April 1988
Resolved
CONDUCT A HYDROSTATIC TEST ON THE ENTIRE FIREMAIN TO 1.5 X MAXIMUM ALLOW- ABLE WORKING PRESSURE OR TO 220 PSI, WHICHEVER IS LEAST, IN THE PRESENCE OFA COAST GUARD MARINE INSPECTOR PRIOR TO GETTING THE VESSEL UNDERWAY.
Condition: Unknown
Due 14 April 1988
Resolved 14 April 1988
Accommodation/Occupational Safety
Issued 14 April 1988
Resolved
INSTALL A PRESSURE RELIEF VALVE OF AT LEAST ONE INCH DIAMETER SET AT OR BELOW 200 PSI FOR THE POTABLE WATER SURGE TANK.
Condition: Unknown
Due 14 April 1988
Resolved 14 April 1988
Construction/Loadline
Issued 9 March 1988
Resolved
COMPLETE THE FOLLOWING TO THE SATISFACTION OF THE COGNIZANT OCMI: (1) CLEANAND RE-COAT B2, B5, B6 AND D4; (2) RENEW TWISTED SIDE SHELL STIFFNER (4TH FROM DECK BETWEEN 1ST CHORD TO BAFFLE BULKHEAD, AS MARKED) IN TANK C2.
Condition: Unknown
Due 9 March 1988
Resolved 9 March 1988