Records from 2006 to 2023. Most recent: inspection, 1 June 2023.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 13 December 2022
Resolved
Conduct satisfactory sea-trial prior to recertification of the vessel to carry passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 February 2023
Resolved 3 April 2023
Resolution: Vessel conducted satisfactory sea trial
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 21 November 2022
Resolved
Propulsion machinery must be suitable type and design and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load. San Diego received report that the vessel had a loss of propulsion while underway.
Vessel is required to demonstrate proper operation of propulsion in the presence of a MI, prior to the carriage of passengers.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 April 2023
Resolution: Vessel demonstrated proper operation of propulsion in the presence of MI.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 21 November 2022
Resolved
Main steering gear must be provided that is of adequate strength and capable of steering the vessel at all service speeds. Sector San Diego received report that the vessel had a loss of steering gear while underway. Vessel is required to demonstrate proper operation of steering gear in the presence of a MI, prior to the carriage of passengers.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 April 2023
Resolution: Vessel demonstrated proper operation of steering gear.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 21 November 2022
Resolved
Except for engine exhaust, each inlet or discharge pipe that penetrates the hull below a line drawn parallel to and at least (6 inches) above the deepest load waterline must have means to prevent water from entering the vessel if the pipe fractures or otherwise fails. Thru-hull inlet below generator was found in the open position with a 3-4 ft hose that was not connected to any piece or machinery allowing for the possibility of the vessel taking on water. Demonstrate thru-hull inlet is completed closed and remains close, remove hose if no longer utilized, recommend that inlet is capped or blanked off.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 March 2023
Resolution: Thru-hull inlet below generator is now capped closed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 21 November 2022
Resolved
Electrical equipment on a vessel must be installed and mainlined so that to minimize accidental personnel contact with energized parts. AC distribution panels #1 and #2, as well as DC distribution panel in wheelhouse missing knockouts posing electrical shock hazard. Provide filler plates over openings or insert spare breaker to fill void.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 April 2023
Resolution: Vessel provided filler plates over openings.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 21 November 2022
Resolved
Paint and flammable liquids locker must be constructed of steel or equivalent material, or wholly lined with steel or equivalent material. Portable gasoline container, 5-gallon paint, and other flammable liquids were found stowed in the compressor compartment. Remove portable gasoline tank and flammable materials from vessel.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 March 2023
Resolution: Portable gasoline container and other flammable liquids have been removed from the compressor room.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 21 November 2022
Resolved
Each life float and buoyant apparatus must be secured to the vessel by a painter and float free link. The float free link must be secured to the painter at one end and secured to the vessel on the other end. Float free link was attached to mast by a yellow line with an unknown breaking strength. Mount weak link/float free link to vessel by means adequate to ensure weak link will not detach from vessel until link is broken.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 March 2023
Resolution: Weak link is now mounted onto vessel, and yellow line has been removed.
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access
Issued 21 November 2022
Resolved
Footholds, handholds, ladders and similar means provided to aid escape, must be suitable for use in emergency conditions, of ridged construction, and permanently fixed in position. Ladder in Engine Room was unbolted and loose. Secure ladder leading down into engine room so its permanently fixed.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 16 March 2023
Resolution: Ladder in engine room is now securely bolted.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 21 November 2022
Resolved
Portable fire extinguishers shall be installed and located to the satisfaction of the Officer in Charge, marine Inspections. Portable CO2 fire extinguisher in Engine Room under stairs is not stowed in an approved bracket/holder and is secured with a bungee cord. Provide an approved mounting bracket for portable CO2 fire extinguisher.
46 CFR 181.30-10(c)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 16 March 2023
Resolution: Portable CO2 fire extinguisher is now stowed in approved bracket/holder.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 21 November 2022
Resolved
All vessels must have navigational lights that are in compliance with the applicable sections of the International and Inland Navigational Rules. The ‘’All-round light” required by rule 30 shall be visible for 2 miles and unbroken for 360 degrees. Increase height of “all-around Light” so that life floats and radar equipment are not blocking the visibility of the white light.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 27 March 2023
Resolution: The height of the all-around light is now above the radar equipment and not blocking the visibility.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 21 November 2022
Resolved
Electrical cooking equipment shall be mounted to prevent dislodgement in heavy seas. Electric toaster oven and single electric range was being utilized in galley for cooking of food and not mounted to vessel. Remove electric cooking equipment if equipment does not meet requirements listed in 46 CFR 183.10-45 or properly mount cooking equipment to the satisfaction of attending Marine Inspector.
46 CFR 183.10-45(b)(2)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 16 March 2023
Resolution: Electric cooking equipment that was not mounted has now been removed off the vessel.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 21 November 2022
Resolved
Each lighting fixture globe, lens, or diffuser must have a guard or made of high strength material. Light in lazarette space is a glass bulb with no protective cover, poses risk to crew members entering the space. Install guard over light bulb or replace fixture with light that is protected from inadvertent contact resulting in electrical shock.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 16 March 2023
Resolution: Guard over light has now been installed.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 21 November 2022
Resolved
Batteries terminals shall be adequately screened or covered by a cage or enclosure to minimize the danger of accidental spark through dropping a metal object across the terminals. Wheelhouse battery had no protective measure for preventing object from dropping on terminals and creating spark/fire. Provide adequate cover/s for terminals to prevent electrical/fire hazard.
46 CFR 183.05-20(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 16 March 2023
Resolution: Wheelhouse battery now has a protective cover.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 21 November 2022
Resolved
Batteries shall be located in an enclosure of suitable construction material so that it is resistant to deteriorating action by the battery electrolyte. Battery under operating station in wheelhouse was unsecured and not secured in an enclosure resistant to battery electrolyte. Provide enclosure for wheelhouse battery.
46 CFR 183.02-20(d)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 16 March 2023
Resolution: Wheelhouse is now in an enclosure.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 21 November 2022
Resolved
Battery terminals shall be of the soldered type and all connections shall be made to the battery terminals with permanent type connections. Battery terminal for wheelhouse battery was secured with a wing nut. Additionally, it is good marine practice to restrict connections to battery terminals to 4 connections, see ABYC standards (E 11.14.4.1.10). Provide connection means of a permanent type and restrict terminal connections to 4 per terminal. If additional power supply is needed a distribution block “bus bar” may need to be installed with adequate over-current protection.
46 CFR 183.05-20(c)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 March 2023
Resolution: Battery terminal in wheelhouse now has less than 4 connections/buss bar has been installed and wingnuts have been removed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 21 November 2022
Resolved
Wiring joints and splices shall be mechanically secured and made in junction boxes. Unless a splice is made by an insulated pressure wire connector listed by UL, it shall be thoroughly soldered, taped first with rubber and with friction tape, or the soldered joint shall be otherwise protected as to provide an insulation the same as that of the conductors joined. Multiple wires joined improperly at various locations throughout the vessel spaces, especially under wheelhouse operating station, engine room, and lazarette space. Re-splice/join conductors properly, taking into account those connections that may be in damp or wet locations.
46 CFR 183.05-50(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 27 March 2023
Resolution: Wires that were observed are now properly joined.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 21 November 2022
Resolved
Junction boxes, connection boxes, and outlet boxes, for use in a damp or wet location shall be watertight construction. AC receptacle at forward operating station exposed to the weather has no protection from water intrusion. Provided a watertight receptacle enclosure to protect receptacle from water intrusion.
46 CFR 183.10-20(k)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 27 March 2023
Resolution: Watertight enclosures for receptacles in wet areas have been installed.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 21 November 2022
Resolved
All electric cooking equipment shall be provided with doors with heavy duty hinges and locking devices to prevent accidental opening in heavy seas and be provided with sea rails with suitable barriers to resist accidental cook pot movement. Electric range installed with no locking devices on doors nor sea rails to prevent accidental injuries to crew. Provide adequate locking devices on doors and install suitable sea rails on range top.
46 CFR 183.10-45 (b)(1)/(3)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 16 March 2023
Resolution: Electric range now has locking device on doors.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 21 November 2022
Resolved
Shore power connection must be located at a convenient location and be a connection box or receptacle permanently installed and a cable connecting this box or receptacle to the main distribution panel. Shore power cable is connected to distribution panel using a pigtail. Provide a permanently installed shore power box or receptacle in a convenient location, means have been made in superstructure to facilitate install.
46 CFR 183.10-50
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 27 March 2023
Resolution: Permanent receptacle for shore power connection has been installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 9 October 2022
Resolved
An exposed hazard, such as gears or rotating machinery, must be properly protected by a cover, guard, or rail.
Ships service diesel generator is missing protective cover around pulley system. Starboard main diesel engine is missing protective cover around pulley system.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 October 2022
Resolved 29 October 2022
Resolution: Operator provided satisfactory proof of belt guards installed in required areas.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 9 October 2022
Resolved
Electrical equipment exposed to the weather must be watertight. Electrical junction box outside on top of pilot house is missing protective cover.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 October 2022
Resolved 29 October 2022
Resolution: Operator provided satisfactory proof of installing missing electrical junction box cover.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 21 July 2022
Resolved
At each initial and subsequent inspection for certification, re-inspection and at every other vessel inspection the marine inspector shall require that all observed unsafe practices and hazardous situations be corrected. Due to the repeated history of compliance concerns with the vessel, it has been placed on a quarterly inspection schedule for the next year. The vessel did not complete required quarterly inspection as per issued CG letter 072-22 dated April 22, 2022. Vessel is not authorized to carry passengers for hire until a satisfactory inspection has been completed by the attending marine inspector. 46 CFR 176.25-50
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 July 2022
Resolution: Vessel satisfactory completed quarterly inspection.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 21 July 2022
Resolved
A vessel must carry either a first-aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions. For equivalent kits, the contents must be stowed in a suitable, watertight container that is marked “First-Aid Kit”. A first-aid kit must be easily visible and readily available to the crew. MI identified missing items from First Aid Kit. However, purchased new USCG approved kit during the course of the exam. Def corrected on the spot.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 21 July 2022
Resolved 21 July 2022
Resolution: First Aid Kit on board and ready for use.
04 - Emergency Systems › N/A - No Subsystem › Muster list
Issued 21 July 2022
Resolved
The master and crew of a vessel will be familiar with the content of and have mounted at the operating station, emergency instructions containing the actions to be taken in the event of fire, heavy weather, or man overboard conditions. Vessel did not have emergency instructions/muster list posted. However, this deficiency was corrected on the spot during the inspection.
Action required: 10 - Deficiency Rectified
Due 21 July 2022
Resolved 21 July 2022
Resolution: The muster list/emergency instruction was posted.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 5 April 2022
Resolved
In the wheel house, electrical panel was missing cover.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 April 2022
Resolved 8 April 2022
Resolution: Def cleared.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 5 April 2022
Resolved
Within the compressor room a light fixture on the overhead was found to be missing the protective globe.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 April 2022
Resolved 8 April 2022
Resolution: Def cleared.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 25 March 2022
Resolved
Each distribution panel or swbd must be totally enclosed
and of the dead end front type. Install blanks totally
enclosing distribution panel.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 April 2022
Resolved 5 April 2022
Resolution: Blanks installed
11 - Life Saving Appliances › N/A - No Subsystem › Operation of Life Saving Appliances
Issued 25 March 2022
Resolved
When stowed in tiers, the separate units must be kept
apart by spacers. Provide spacers for lifefloats.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 April 2022
Resolved 8 April 2022
Resolution: def cleared
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 26 March 2021
Resolved
A vessel must be provided with a satisfactory arrangement for draining any watertight compartment, other than small buoyancy compartments under all practicable conditions. Bilge suction was not operable in the compressor room. Prove proper operation of bilge suction in the compressor prior to carrying passengers.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 26 March 2021
Resolution: Corrected on the spot.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 26 March 2021
Resolved
A penetration in a watertight bulkhead must be as high and as far inboard in the bulkhead as practicable, and made watertight. There are multiple penetrations located on the bulkhead between the air compressor compartment and the engine room that are not water tight. Make penetrations watertight.
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Due 26 March 2021
Resolved 1 April 2021
Resolution: Penetrations were filled with fire stop.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 26 March 2021
Resolved
Provisions shall be made by means of plugs, covers, etc., to prevent the admission of air into the space protected. Vessel does not have vent closure. Submit plan for approval and install vent closures.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 26 March 2021
Resolved 1 April 2021
Resolution: Vessel installed vent closures.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 26 March 2021
Resolved
Doors on a cooking appliance must be provided with hinges and locking devices to prevent accidental opening in heavy seas. Sea rails with suitable barriers to prevent accidental movement of cooking pots, must be installed on a cooking range. The electric range/over does does not have a locking device or sea rails. Provide locking device and sea rails prior to use.
Action required: 705 - Other - as specified
Due 26 March 2021
Resolved 16 March 2023
Resolution: The electric range/oven now has a locking device/sea rail.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 26 March 2021
Resolved
Each overnight accommodation space on a vessel with overnight accommodations for passengers must be fitted with an independent modular smoke detection and alarm unit. Vessel has smoke detectors in the bunk room, but due to the construction of the vessel there is the potential for smoke to accumulate in pockets in the bunk room that are not protected by the already installed smoke alarms. Install additional smoke alarms to ensure adequate coverage prior to using overnight accommodations.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 26 March 2021
Resolved 1 April 2021
Resolution: Vessel installed smoke detectors to ensure coverage of potential smoke accumulation pockets.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 26 March 2021
Resolved
Connections must be made to battery terminals with permanent type connectors. Batteries have wing nuts. Replace all wing nuts with permanent type connectors.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 April 2021
Resolved 1 April 2021
Resolution: Permanent type connectors were installed.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 26 March 2021
Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected. The emergency egress ladder from the bunk room is not adequate. Provide adequate means of egress for emergency egress hatch accessible from bunk room prior to using overnight accommodations.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 26 March 2021
Resolved 16 March 2023
Resolution: Egress ladder is now adequate in bunk room.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 26 March 2021
Resolved
A hatch exposed to the weather must be watertight. The hatch for the space forward of the collision bulkhead was found to have mousing wire and the gasket was found to be damaged. Replace gasket and prove proper operation of the watertight hatch.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 April 2021
Resolved 7 April 2023
Resolution: [name withheld] replaced gasket. Tested gasket with fire hose; all sat.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 26 March 2021
Resolved
Each item of survival craft equipment must be of good quality, and efficient for the purpose it is intended to serve. One of the vessel’s life floats has tears/gouges in the life floats. Properly repair life floats in accordance with manufacturer's instructions or replace.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 April 2021
Resolved 16 March 2023
Resolution: Life float has properly been repaired.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 26 March 2021
Resolved
The name of the vessel must be marked or painted in clearly legible letters on each life float paddle. Vessel name is missing on one set of oars for the life floats. Properly mark the name of the vessel on the life float oars.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 April 2021
Resolved 1 April 2021
Resolution: Oars have vessel's name on them.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 26 March 2021
Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards. MI discovered multiple dead end wire runs in the compressor space. Remove all dead end wiring.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 April 2021
Resolved 1 April 2021
Resolution: All dead end wiring in the compressor room was removed.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 26 March 2021
Resolved
A vessel must comply with structural requirements. MI discovered fracture on the deck frame and broken crew bunk located on the starboard side. Make proper structural repairs to the fractured deck frame.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 April 2021
Resolved 1 April 2021
Resolution: Repairs were made.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 26 March 2021
Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected. Ladder going into compressor room is not secured to the bulkhead. Secure ladder to the bulkhead.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 April 2021
Resolved 1 April 2021
Resolution: Ladder was properly secured.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 11 March 2021
Resolved
A vessel must be operated in accordance with applicable laws and regulations and in such a manner as to afford adequate precaution against hazards that might endanger the vessel and the persons being transported. Deficiencies 2-5 provide objective evidence that the vessel is substandard and not pro-actively managing technical and operational requirements. Vessel must complete a satisfactory Expanded Annual inspection prior to any movement.
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 1 April 2021
Resolution: Vessel completed satisfactory annual inspection.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 11 March 2021
Resolved
An adult life jacket must be provided for each person carried on board a vessel. Vessel was missing 5 required life jackets.
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 26 March 2021
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 11 March 2021
Resolved
A vessel on an oceans, coastwise, limited coastwise, or Great Lakes route must carry six hand red flare distress signals approved in accordance with §160.021 in subchapter Q of this chapter, or other standard specified by the Commandant, including, but not limited to, approval series 160.121. Vessel operates on an oceans route and had six missing/expired required hand red flare distress signals.
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 26 March 2021
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 11 March 2021
Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected and all required guards and protective devices must be in satisfactory condition. Vessel used daisy chained power strips and an extension cord to power vital systems on the bridge including GPS, modem for security, freezer, monitor, cell phone charger, and multi-recharge station for radios.
46 CFR 176.830(a)
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 26 March 2021
Resolution: Daisy chained power strips and extension cords were removed.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 11 March 2021
Resolved
The owner, managing operator, or a qualified servicing facility as applicable must conduct the following inspections and tests: Portable and semi-portable extinguishers must be inspected and maintained in accordance with NFPA 10. For fixed-gas fire extinguishing systems, the owner or managing operator must provide satisfactory evidence of the required servicing to the marine inspector. Annual portable extinguishers and fixed-gas fire extinguishing system inspection had lapsed by four months. Last servicing inspection was completed on 14OCT19.
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 26 March 2021
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 11 March 2021
Resolved
Any vessel of at least five net tons which engages in the fisheries on the navigable waters of the United States or in the Exclusive Economic Zone, or coastwise trade, unless exempt under §67.9(c), must have a Certificate of Documentation bearing a valid endorsement appropriate for the activity in which engaged. Vessel COD had expired on September, 30th 2020 and vessel openly acknowledged that the COD was not renewed and had been knowingly operating without a valid COD. Vessel restricted from coastwise trade until COD is valid.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 March 2021
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 11 March 2021
Resolved
Vessel owners shall advise NOAA in writing upon change of vessel or EPIRB ownership, transfer of EPIRB to another vessel, or any other change in registration information. NOAA will provide registrants with proof of
registration and change of registration postcards. EPIRB was not registered. Cite: 47 CFR 80.1061(f)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 March 2021
Resolved 18 March 2021
Resolution: Vessel rep provided EPIRB registration update receipt.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 11 March 2021
Resolved
The EPIRB test required by paragraph (a) (monthly) shall be logged or otherwise documented, as applicable. EPIRB Monthly tests were not logged appropriately.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 March 2021
Resolved 26 March 2021
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 11 March 2021
Resolved
Each child size life jacket must be stowed in a location that is appropriately marked and separated from adult life jackets so the child size life jackets are not mistaken for adult life jackets. Child size life jackets were not appropriately marked from adult life jackets.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 March 2021
Resolved 18 March 2021
Resolution: Vessel crew appropriately marked the stowage location and number of child life jackets.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 11 March 2021
Resolved
Placards containing instructions for the donning and use of the life jackets aboard the vessel must be posted in conspicuous places that are regularly accessible and visible to the crew and passengers. Vessel is missing donning instruction placard for life jackets.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 March 2021
Resolved 26 March 2021
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 11 March 2021
Resolved
Each item of lifesaving equipment determined by the marine inspector to not be in serviceable condition must be repaired or replaced. Two locking pins for the waterlight attached to the life float were missing, replace waterlight casing to original.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 March 2021
Resolved 3 April 2023
Resolution: Vessel replaced waterlight.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 11 March 2021
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date charts, U.S. Coast Pilot [name withheld] List, tide table, and current tables.
Vessel paper chart was uncorrected from 2003, and Coast
Pilot, light list, and tide/current tables were missing.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 March 2021
Resolved 18 March 2021
Resolution: Vessel rep provided updated copies of charts, U.S. Coast Pilot, light list, and tide/current tables.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 11 March 2021
Resolved
All vessels must have navigation lights that are in compliance with the applicable sections of the International and Inland Navigation Rules. STBD navigation light was found inoperable when tested. Vessel crew tapped on casing which was loose fitting
and light illuminated. STBD navigation light electrical to be properly inspected and casing properly repaired.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 March 2021
Resolved 18 March 2021
Resolution: Vessels crew properly repaired electrical wiring and casing to the STBD navigation light.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 11 March 2021
Resolved
The manufacturer's instructions for onboard maintenance of survival craft, rescue boats, and launching appliances, manufactured on or after March 11, 1996, must be onboard a vessel of more than 19.8 meters (65 feet) in length and readily available for a vessel of not more than 19.8 meters (65 feet) in length. The inspection and maintenance of the equipment listed in paragraph (a) of this section shall be logged or otherwise documented for review by the Coast Guard upon request. Vessel crew was not logging survival craft maintenance.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 March 2021
Resolved 26 March 2021
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 1 March 2021
Resolved
A vessel that is exposed to salt water more than three months in any 12 month period since the last examination must undergo a drydock examination and an internal structural at least once every two years. Vessel exceeded two year interval on 01MAR2020. Vessel required to undergo satisfactory drydock examination prior to departure from port or carrying passengers.
Action required: 17 - Rectify deficiencies prior to departure
Due 1 March 2021
Resolved 9 April 2021
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 18 February 2021
Resolved
A vessel to which this sub-chapter applies may not be operated without having on board a valid U.S. Coast Guard Certificate of Inspection. Vessel is over due for a COI Annual Inspection. Vessel is requires to undergo a COI Annual inspection prior to departure from port or carrying passengers.
Action required: 17 - Rectify deficiencies prior to departure
Due 18 February 2021
Resolved 1 April 2021
Resolution: Vessel completed satisfactory annual inspection.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 14 August 2020
Resolved
An EAP training progarm must be conducted for the employers, crew members and supervisory personnel. The training program must include documentation of training given to crew members and employers supervisory personnel. Supervisory personnel must recieve at least 60 minutes of training. Provide proper documentation of all crew and supervisory training.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 August 2020
Resolved 28 August 2020
Resolution: Recieved electronic documentation for training being conducted and recorded.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 1 August 2020
Resolved
Over-current protection shall be provided for each conductor for the purpose of opening the electric circuit if the current reaches a value which will cause an excessive or dangerous temperature in the conductor or conductor insulation. Provide appropriate over-current protection.
Old T 46 CFR 183.10-35(a)
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 August 2020
Resolved 12 August 2020
Resolution: Replaced 2 breakers, corrected alignment issues, secured panel faceplaces--tested under load. All satisfactory.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 1 August 2020
Resolved
Employers chemical testing program shall be in compliance with the provisions of this part. Prove proper compliance with DAPI program via USCG DAPI Audit.
46 CFR 16
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 August 2020
Resolved 14 August 2020
Resolution: Completed DAPI Audit, missing crew and supervisor training--wrote additional 835 to provide training and cleared this def and operational control.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 1 August 2020
Resolved
On a vessel on which the number of passengers permitted on upper decks is limited by stability criteria, the maximum number of passengers allowed on the upper deck must be indicated by marking. Provide proper signage for maximum passengers on top deck.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 August 2020
Resolved 12 August 2020
Resolution: Placcard posted and number of passengers verfied against stability letter.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 1 August 2020
Resolved
Cooking and heating equipment must be suitable for marine use. Prove proper approval of cooking equipment on board (grill on deck) or remove from vessel.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 August 2020
Resolved 12 August 2020
Resolution: Grill removed from vessel.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 1 August 2020
Resolved
Licenses of radios are required to have current station documents as indicated in regulation. Provide valid FCC Safety Certificate. 47 CFR 80.401
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 September 2020
Resolved 16 November 2020
Resolution: Vessel provided satisfactory documentation of approved and updated FCC Safety Certificate.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 10 November 2019
Resolved
All Machinery must be installed and maintained in such a manner as to afford protection from causing fire, explosion, machinery failure and personnel injury. Vessel suffered a loss of propulsion while underway with passenger on board. Demonstrate proper operation of main diesel engine(s) prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 November 2019
Resolution: Vessel proved proper operation of the port MDE.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 11 October 2019
Resolved
A vessel must be operated IAW applicable laws and regulations and in such a manner as to afford adequate precaution against hazards that might endanger the vessel and the persons being transported.
Vessel does not have crew as per TCOI enrolled in DAPI.
Documents to new owner have not all been xfered.
No records of training.
No fire servicing records.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 October 2019
Resolution: Vessel completed COI inspection.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 25 June 2019
Resolved
Wheelhouse fire extinguisher gauge shows depleted pressure. Fire extinguishers were serviced 24JUN19. Provide fire extinguisher showing full charge / pressure.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 July 2019
Resolved 19 July 2019
Resolution: Vessel provided replacement fire extinguisher.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 25 June 2019
Resolved
First aid kit contained multiple expired items. Provide complete and current first aid kit.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 July 2019
Resolved 19 July 2019
Resolution: Vessel provided new first aid kit.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 25 June 2019
Resolved
Provide current coast pilot, light list, tides/currents, and charts.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 July 2019
Resolved 19 July 2019
Resolution: Vessel provided publications.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 25 June 2019
Resolved
Provide additional retroreflective tape on lifejackets.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 July 2019
Resolved 19 July 2019
Resolution: Vessel provided additional retrofelctive tape.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 25 June 2019
Resolved
EPIRB testing not logged.
Action required: 10 - Deficiency Rectified
Due 25 June 2019
Resolved 25 June 2019
Resolution: Vessel representative tested EPIRB and completed log during inspection.
07 - Fire Safety › N/A - No Subsystem › Evaluation of crew performance (fire drills)
Issued 25 June 2019
Resolved
Fire and Man Overboard drills not logged.
Action required: 10 - Deficiency Rectified
Due 25 June 2019
Resolved 25 June 2019
Resolution: Vessel conducted and logged firefighting and man overbaord drills during inspection.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 17 July 2018
Resolved
Renew life ring light, restricted to daylight only until corrected.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 July 2018
Resolved 7 August 2018
Resolution: Installed new light.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 17 July 2018
Resolved
Renew weak link to life floats.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 July 2018
Resolved 7 August 2018
Resolution: Installed new weak link.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 17 July 2018
Resolved
Provide a copy of American Maritime Renewal document and MIS report.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 August 2018
Resolved 24 July 2018
Resolution: Documents provided
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 17 July 2018
Resolved
Renew alcohol swabs.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 August 2018
Resolved 24 July 2018
Resolution: Swabs renewed.
Fire Fighting › Fixed Gas Fire Extinguishing System › Quantity of Gas
Issued 20 July 2017
Resolved
Re-charge fixed fire extinguishing agent in E/R prior to operating with passengers.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 July 2017
Resolved 1 August 2017
Resolution: Service report received and inspected sat.
Operations/Management › Vessel Activity › Underway
Issued 20 July 2017
Resolved
Make vessel available for underway machinery & steering inspection.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 20 August 2017
Resolved 31 July 2017
Resolution: Underway machinery and steering inspected sat.
Lifesaving › Lifejacket/PFD (Type I) › Lights
Issued 20 July 2017
Resolved
Provide (02) PMLs for L/Js
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 August 2017
Resolved 31 July 2017
Resolution: Lifejacket lights provided.
Documentation › Markings/Placards › Warning Signs
Issued 20 July 2017
Resolved
Stencil emergency fuel shut-off locations.
Condition: Invalid
Action required: 705 - Other - as specified
Due 20 August 2017
Resolved 17 August 2017
Engineering › Bilge Water Management System › Pump
Issued 20 July 2017
Resolved
Secure Rule bilge pump in laz.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 20 August 2017
Resolved 31 July 2017
Resolution: Bilge pump secured.
Communications › Radio Communications › VHF Radiotelephone
Issued 20 July 2017
Resolved
Provide VHF-DSC radio.
Condition: Invalid
Action required: 705 - Other - as specified
Due 20 August 2017
Resolved 17 August 2017
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 1 March 2017
Resolved
Properly mount portable fire extinguishers.
Action required: 705 - Other - as specified
Due 1 April 2017
Resolved 11 April 2017
Resolution: Extinguishers are properly mounted.
Lifesaving › Hand Flares › Expired
Issued 10 May 2016
Resolved
Prior to operating with passengers, provide 04 red hand-held flares.
Condition: Invalid
Action required: 705 - Other - as specified
Due 10 May 2016
Resolved 10 May 2016
Resolution: Corrected while on board.
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 10 May 2016
Resolved
Replace reflective tape on 06 lifejackets
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 June 2016
Resolved 17 June 2016
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 10 May 2016
Resolved
Renew drug testing contract NLT 31MAY16 or provide proof of enrollment with alternate company.
Condition: Invalid
Action required: 705 - Other - as specified
Due 31 May 2016
Resolved 31 May 2016
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 10 May 2016
Resolved
Provide proof of fixed gas firefighting system servicing NLT 27JUL16
Condition: Invalid
Action required: 705 - Other - as specified
Due 27 July 2016
Resolved 7 July 2016
Lifesaving › Lifejacket/PFD (Type I) › Lights
Issued 10 May 2016
Resolved
Prove proper operation of two lifejacket marker lights.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 May 2016
Resolved 10 May 2016
Resolution: Corrected on-the-spot
Communications › Radio Communications › EPIRB
Issued 10 May 2016
Resolved
[name withheld] with vessel name or current registration decal.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 10 May 2016
Resolved 10 May 2016
Resolution: Corrected on-the-spot