Records from 1986 to 2005. Most recent: inspection, 20 April 2005.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 18
20 April 2005
Type not recorded
No type recorded · Station Cape Disappointment · USCG Northwest District (CGD-NW) · Activity 2350028
14 June 1995
Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 877306
19 December 1994
Examination of Repairs
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1367249
3 November 1994
Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1356885
16 June 1994
Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1425471
13 April 1993
COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1385046
23 November 1992
Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1473347
10 November 1992
Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1269476
5 August 1992
Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 948046
16 June 1992
Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 947255
11 June 1991
Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1202330
4 April 1991
Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1243311
30 May 1990
COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1214497
6 June 1989
Excursion Permit · Re-Inspection · Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1350723
21 October 1987
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1017560
5 June 1987
COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1005165
2 June 1986
Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 991160
17 April 1986
Credit Drydock
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1311551
Construction/Loadline
Issued 16 June 1992
Resolved
INSTALL A KEEPING DEVICE FOR THE ENGINE ROOM HATCH.
Condition: Unknown
Due 16 June 1992
Resolved 16 June 1992
Navigation
Issued 16 June 1992
Resolved
PROVIDE A COMPASS DIVIATION TABLE.
Condition: Unknown
Due 16 June 1992
Resolved 16 June 1992
Fire Fighting
Issued 5 June 1987
Resolved
PROVIDE ADDITIONAL B-II FIRE EXTINGUISHER FOR THE GALLEY AREA (A TOTAL OF 3 B-II EXTINGUISHERS ARE REQUIRED).
Condition: Unknown
Due 5 June 1987
Resolved 5 June 1987
Lifesaving
Issued 5 June 1987
Resolved
RENEW GRAB LINES ON BUOYANT APPARATUS.
Condition: Unknown
Due 5 June 1987
Resolved 5 June 1987
Lifesaving
Issued 5 June 1987
Resolved
PROVIDE ADDITIONAL ACCEPTABLE CHILD LIFE PRESERVER (A MINIMUM OF 2 ARE REQUIRED).
Condition: Unknown
Due 5 June 1987
Resolved 5 June 1987
Engineering
Issued 5 June 1987
Resolved
PROVIDE A CHECK VALVE IN THE ELECTRICAL BILGE PUMP DISCHARGE LINE (IN ACCORDANCE WITH 46 CFR 182.25-5(C)).
Condition: Unknown
Due 5 June 1987
Resolved 5 June 1987
Unknown
Issued 5 June 1987
Resolved
PROVIDE DOUBLE CLAMP FOR FISH CLEANING SEA SUCTION LINE (FLEXIBLE LINE) AND PROVIDE REINFORCED FLEXIBLE LINE.
Condition: Unknown
Due 5 June 1987
Resolved 5 June 1987
Electrical
Issued 5 June 1987
Resolved
PROVIDE ADDITIONAL FLASHLIGHT FOR EMERGENCY LIGHTING.
Condition: Unknown
Due 5 June 1987
Resolved 5 June 1987