MAURY USCG vessel records Sign in
← All vessels

HOS TRADER

HOS TRADER is a 1997 offshore supply vessel. The Coast Guard has recorded 35 inspections since 1997, most recently in July 2012, along with 16 deficiencies and 1 casualty investigation in 2013.

Records from 1997 to 2013. Most recent: casualty investigation, 10 March 2013.

Built
1997
Last inspected
27 July 2012
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8964446 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WDB4535
455622
Flag
UNITED STATES
366899470, 368664000 (licence lapsed)
Maury page id
psix-455622

Inspections, by type

…with no type recorded6
Years with a record 14 calendar years (1997–2012)
The 35 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 14 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Tonnage as PSIX records it358 - Convention (Subpart B), Net Ton
308 - Regulatory (Subpart C or D), Net Ton
1194 - Convention (Subpart B), Gross Ton
454 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WDB4535MMSI 366899470 · cancelled · compulsorily equipped · granted 21 May 2013, cancelled 24 November 2014
WCX7938MMSI 368664000 · expired · compulsorily equipped · granted 29 October 1998, cancelled 15 December 2007 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 35

27 July 2012 Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4392559
2 February 2010 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3674369
25 November 2008 Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3369091
14 November 2007 Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3128787
8 November 2007 Hull Examination · Examination of Repairs · Internal Structural Exam · Cargo Tank Internal
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3095128
27 April 2007 In-Service Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2916973
6 September 2006 Administrative Inspection
Administrative · Marine Safety Center (MSC) · Activity 2770433
1 September 2006 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2765855
3 November 2005 Drydock Extension · Examination of Repairs · COI Inspection · Hull Examination · Administrative Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2527117
18 February 2005 Administrative Inspection
Administrative · Marine Safety Center (MSC) · Activity 2295311
4 February 2005 MTSA Verification · Administrative Inspection · Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2286709
20 April 2004 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2048418
3 March 2004 Administrative Inspection
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2017275
3 February 2004 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1999444
29 December 2003 Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1979410
7 August 2003 Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1869565
6 November 2002 Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1676574
19 November 2001 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1414037
16 February 2001 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 75512
16 February 2001 Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 144211
16 February 2001 Damage Survey · Examination of Repairs
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1058538
18 September 2000 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 721325
4 August 2000 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 821341
31 July 2000 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 166612
20 April 2000 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 767065
13 April 2000 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 208570
8 November 1999 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1415281
9 November 1998 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1455646
8 October 1998 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 806677
17 August 1998 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1130996
10 July 1998 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1128647
16 March 1998 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1108775
19 November 1997 Inclining Experiment · Hull Examination · Initial Certification · Initial Construction-Excluding Oversight
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1442650
22 September 1997 Inclining Experiment
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1113311
14 April 1997 Initial Construction-Excluding Oversight
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1396703

Deficiency record · 16

Communications › Public Address System › Loudspeaker
Issued 25 November 2008 Resolved
Install addtional PA speakers internally to service all normally manned spaces to supplement General Alarm
Due 26 December 2008
Resolved 15 August 2012
Resolution: Tested General Alarm with Public Address system, spaces normally manned determined to meet applicable requirement.
Engineering › Diesel Engine (auxiliary) › Overspeed Device
Issued 25 November 2008 Resolved
Demonstate proper operation of Generator engine overspeeds.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 November 2008
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 25 November 2008 Resolved
Demonstrate proper operation of OWS or provide third party certificate.
Due 26 December 2008
Resolved 15 August 2012
Resolution: Proper operation of the Oily Water Separator was demonstrated.
Lifesaving › Launching Appliances › Davit
Issued 25 November 2008 Resolved
Provide data for vessel weight in comparison to vessel weight to include engine and required equipment. Vessel recently changed out Rescue Boat with different weight.
Due 26 December 2008
Resolved 20 August 2012
Resolution: Data provided with weight test of cable to "B" weight.
Lifesaving › Rescue Boat
Issued 3 February 2004 Resolved
Provide proof of rescue boat davit cable renewal prior to 04 MAR 2004. LEGACY COMPONENT DESC: Cable
Action required: 705 - Other - as specified
Due 4 March 2004
Resolved 12 March 2004
Lifesaving › Lifebuoys
Issued 3 February 2004 Resolved
Renew retro reflective tape on various life rings as discussed prior to sailing. LEGACY COMPONENT DESC: Retro reflective Tape
Action required: 17 - Rectify deficiencies prior to departure
Due 3 March 2004
Resolved 12 March 2004
Documentation › Safety Management System
Issued 3 February 2004 Resolved
Provide proof of automation test results in last twelve months, must match approved test procedures. Fax to [phone withheld] prior to 04 MAR 2004. LEGACY COMPONENT DESC: Conformity Maintenance Procedures
Action required: 705 - Other - as specified
Due 4 March 2004
Resolved 12 March 2004
Engineering › Fuel Oil Service System
Issued 3 February 2004 Resolved
Provide chaffing gear for both main engines as discussed. LEGACY COMPONENT DESC: Hose
Action required: 705 - Other - as specified
Due 3 March 2004
Resolved 12 March 2004
Engineering › Fuel Oil Service System
Issued 3 February 2004 Resolved
Provide chaffing gear for both generators. LEGACY COMPONENT DESC: Hose
Action required: 705 - Other - as specified
Due 3 March 2004
Resolved 12 March 2004
Engineering › Fuel Oil Service System
Issued 3 February 2004 Resolved
Renew RACOR fuel hoses on both generators. LEGACY COMPONENT DESC: Hose
Action required: 705 - Other - as specified
Due 3 March 2004
Resolved 12 March 2004
Pollution Prevention/Response › Prevention Equipment
Issued 3 February 2004 Resolved
Renew sewage gauge. LEGACY COMPONENT DESC: Sewage System Tank
Action required: 705 - Other - as specified
Due 3 March 2004
Resolved 12 March 2004
Engineering › Electric Propulsion System
Issued 3 February 2004 Resolved
Make repairs to electric switchboard grounds. LEGACY COMPONENT DESC: Ground Detection Equipment Circuitry
Action required: 17 - Rectify deficiencies prior to departure
Due 3 March 2004
Resolved 12 March 2004
Engineering › Shafting/Propeller Arrangements
Issued 3 February 2004 Resolved
Make repairs to both shaft packing leaks prior to sailing. LEGACY COMPONENT DESC: Propeller Shaft
Action required: 17 - Rectify deficiencies prior to departure
Due 3 March 2004
Resolved 12 March 2004
Lifesaving
Issued 19 November 1997 Resolved
INSTALL APPROVED RESCUE BOAT DAVIT AND SUBMIT STRUCTURAL DRAWINGS FOR MOUNTING AREA.
Condition: Unknown
Due 19 November 1997
Resolved 19 November 1997
Lifesaving
Issued 19 November 1997 Resolved
INSTALL APPROVED RESCUE BOAT.
Condition: Unknown
Due 19 November 1997
Resolved 19 November 1997
Deck/Cargo
Issued 19 November 1997 Resolved
INSTALL REMOTE OPERATING MECHANISMS FOR THE LIQUID MUD SYSTEM SUCTION PIPING.
Condition: Unknown
Due 19 November 1997
Resolved 19 November 1997

Casualty record · 1

10 March 2013Routine · role: Acknowledged Pollution Source · activity 4547111
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.